Industrial Power Supplies * * * * * * * * * * TIB 480 Series, 480 Watt Slim profile, for DIN-rail mounting Alternative side-mounting for flat panels High power factor by active power correction Very high efficiency up to 95% Back power immunity 150% peak current for 4 sec. Operating temperature range: -40C to +70C max. Adjustable output voltage DC-OK indicator Short circuit and overload protection CB Scheme UL508 UL60950-1 This generation of DIN-rail power supplies combines the most efficient circuit topology with optimized cost/performance ratio for industrial environments and for electrical control cabinets. They have a very high efficiency of up to 95.0% which allows a very slim package design. The output voltage is adjustable from -2% to +17%. The case offers the potentially useful feature to fix the DIN-rail clip to the side wall for the mounting inside flat panels. Over a period of minimum 4 seconds they can operate with a boost power of 150%. The boost power facilitates the activation of stepper motors, solenoids or actuators. The units operate with a high power factor of up to 99% by active power factor correction which also keeps the input inrush current low. The TIB series are also available with lower nominal power of 80, 120 or 240 Watt (+50% boost power). They come with the safety standard approvals for IEC/EN 60950-1, UL 60950-1 and UL 508. Other output power of same series: www.tracopower.com/overview/tib Models Order Code Output Power (max.) Output Voltage nom. (adjustable) Output Current (max.) Efficiency (typ.) TIB 480-124 480 W 24 VDC (23.5-28.0) 20 A 95.0 % TIB 480-148 480 W 48 VDC (47.0-56.0) 10 A 95.0 % www.tracopower.com Page 1 of 6 TIB 480 Series, 480 Watt Input Specifications Input voltage - nominal ranges 100 - 240 VAC - effective ranges 85 - 264 VAC (below 90 VAC a derating of 3%/V is required) Input voltage frequency 45 - 65 Hz Standby power cunsumption 4.8/3.8 W (115/230 VAC) Power Factor Correction (PFC) 0.99/0.97 (115/230 VAC) Harmonic limits - acc. EN 61000-3-2 class A, D Inrush current 15/30 A max. (115/230 VAC) Output Specifications Output voltage adjustment 1) 24 Vout models: 23.5 - 28.0 V 48 Vout models: 47.0 - 56.0 V Regulation - Input variation 0.1 % max. - Load variation (10-90 %) 0.5 % max. Temperature coefficient 0.02 %/K Hold-up time 20 ms min. Start-up time 2 s max. Ripple and Noise (20MHz bandwidth) 24 Vout models: 100 mVp-p max. 48 Vout models: 200 mVp-p max. Output overvoltage protection (OVP) 2) 24 Vout models: 32 - 35 V 48 Vout models: 56 - 60 V Power back immunity 3) Operation Duty cycle 4) (for peak and cc mode) < OVP level - Nominal operation 100 % of Iout nom. - Peak power operation 105 - 150 % of Iout nom. - Constant current (cc) > 155 % of Iout nom. - Threshold - CC or peak opeartion timer - normal operation / off period > 105 % 4 s max. (switch off) 10 s typ. (automatic restart after switch off or peak and cc operation timer reset) Short circuit Switch off after 4s delay, automatic restart DC OK signal - Threshold for Vout 24 Vout models: on: > 22.5 V typ., off: < 21.5 V typ. 48 Vout models: on: > 45 V typ., off: < 43 V typ. - DC ON relay contact closed, 1 A max., < 100 mOhm (also indicated by green LEDs: front and side) - DC OFF relay contact open, 30 V max. 1) Output voltage can be adjusted as indicated. However, output power has to be maintained at nominal value. This means the output nominal current has to be reduced in accordance with the increase of output voltage. 2) In case of an internal error a second voltage regulation loop keeps the output voltage at a save level, the power supply turns off and restarts after typ. 10 seconds. 3) When external voltage is supplied above set output voltage and below OVP threshold, the power supply will function normally without switch off or destruction, even if external voltage is applied continuously. 4) In case of overload or short circuit, the unit switches the output voltage off after 4 seconds and tries to restart every typ. 10 seconds. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 6 TIB 480 Series, 480 Watt General Specifications Operating temperature range -40C to +70C max. Derating 24 Vout models: 2 %/K above +60C 48 Vout models: 1.4 %/K above +55C Cooling convection cooling, no internal fan Overtemperature protection switch off at overtemperature Humidity (non condensing) 5-95 % rel. H max. Altitude during operation 2000 m max. Isolation Voltage - Input/Ouput 4250 VDC - Input/Chassis 1500 VDC - Ouput/Chassis 750 VDC Creapage Clearance - Input/Ouput 8 mm - Input/Chassis 4 mm - Output/Chassis 1.5 mm MTBF (acc. to IEC 61709 at 25C) > 1`000`000 h Safety standards - Information technology equipment IEC/EN 60950-1, UL 60950-1 CSA 22.2 No 60950-1-03 - Safety low voltage switchgear and controlgear UL 508 - Certification documents www.tracopower.com/overview/tib Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 - Conducted emission input EN 55032, EN 55011 class B - Radiated RI emission EN 55032, EN 55011 class B Electromagnetic compatibility (EMC), Immunity - Railway applications signalling apparatus - Railway applications rolling stock apparatus - Electrostatic discharge (ESD) - Radiated RF field immunity - Electrical fast transient / burst immunity - Surge immunity - Immunity to conducted RF disturbances - Power frequency field immunity - Mains voltage dips and interruptions - Voltage sag immunity EN 61000-6-2, EN 61204-3 EN 50121-4 EN 50121-3-2 IEC/EN 61000-4-2 4 kV/8 kV IEC/EN 61000-4-3 10 V/m IEC/EN 61000-4-4 2 kV IEC/EN 61000-4-5 1 kV/2 kV IEC/EN 61000-4-6 10 V IEC/EN 61000-4-8 30 A/m IEC/EN 61000-4-11 SEMI F47 (230 VAC) Environment - Railway applications shock and vibration only fulfilled with optional DIN Rail Clip TIB-RMK01 - Vibration acc. IEC 60068-2-6-3 - Shock acc. IEC 60068-2-27 according EN 61373 www.tracopower.com/products/tib-rmk01.pdf 3 axis, 2 g sine sweep, 10-55 Hz, 11 okt/min 3 axis, 25 g half sine, 11 ms Enclosure material - Chassis / Cover aluminium / stainless steel Mounting - DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 criteria A criteria A criteria B criteria B criteria A criteria A criteria B/C criteria A Environmental compliance - Reach www.tracopower.com/info/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU Connection screw terminals Remote On/Off - contact rating - signal assignement The unit can be controlled by external relay contact or open collector signal. open: 15 V; leakage current max 100 A close: 0.3 V; max drop at 15 mA Normal operation 1 2 www.tracopower.com 3 1 2 3 ON = open OFF = closed Reversed operation ON = closed OFF = open Page 3 of 6 TIB 480 Series, 480 Watt Function Specification Output Characteristic Characteristic: Output voltage vs output current for overload conditions until switch off after 4 s at nominal input voltages www.tracopower.com Page 4 of 6 TIB 480 Series, 480 Watt Output Characteristic (continued) Derating: max load vs input voltage Derating: Load vs ambient temperature www.tracopower.com Page 5 of 6 TIB 480 Series, 480 Watt Outline Dimensions * Measurement from front panel to DIN-Rail 118,6 1* 114,2 1 82 1 M3 Combi Head 6,35 24 VDC/20 A DC ON 124,2 1 V adj. Industrial Power Supply 480 W Model TIB 480-124 DC OK Remote ON/OFF GND 3,5 DIN-Rail Hook 100-240 VAC, 50-60 Hz 2.89-1.27 A L N 9,5 M3 M2 Combi Head Combi Head Weight: 1018g (35.91 oz) Alternative side mounting: 24 VDC/20 A DC ON DC ON V adj. Industrial Power Supply 480 W Model TIB 480-124 DC OK Remote ON/OFF GND 100-240 VAC, 50-60 Hz 2.89-1.27 A L N (c) Copyright 2019 Traco Electronic AG Specifications can be changed without notice! Rev. March 13, 2019 www.tracopower.com Page 6 of 6