Unrestrained Storage and Connection Data storage no longer be bound by transmission wires Be mt SP Sd tH fy ed GE MAH comp INTEXT USB STO HE , 820060 at GDM-8300 Series 50000 Counts Dual Measurement Multimeter e 50000 Counts Vacuum Fluorescent Display with Two Colors e Dual Measurement e Fast Measurement Rate Up to 40 readings/s for DCV e 0.02% DCV Basic Accuracy e Auto/Manual Ranging e True RMS (AC, AC+DC) e 11 Measurement Functions e Max./Min.,REL,MX+B,1/X,Ref %,Compare,Hold,dB,dBm e Standard USB device for communicating to PC e Temperature Measurement (GDM-8342 only) e USB Storage for Data Collection (GDM-8342 only) e Optional GPIB (factory install for GDM-8342 only) www.gwinstek.com GW INSTEK Simply Reliable D ARA A ne. i DC VOLTAGE True RMS AC (or AC+DC AC Coupled) Voltage (576) Range(*3) Resolution Input Resistance | Accuracy 1 Year (23C+5C) Range(*3) Resolution | Frequency Accuracy 1 Year (23C+5C) 500.00mV 10pV 10MQ or >10GQ 0.02 +4 500.00mV 10pV 30Hz ~ 50Hz 1.00 + 40 5.0000V 100pV 10MQ or >10GQ 0.02 + 4 50Hz ~ 10kHz 0.50 + 40 50.000V mV 11.1MQ 0.02 +4 10kHz ~ 30kHz 2.00 + 60 500.00V 10mvV 0.02 +4 eee We 3.00 + 120 Sacnol ee TOTNES ebb 5.0000V 100pV 30Hz ~ 50Hz 1.00 + 20 m 1oMQ et 50Hz ~ 10kHz 0.35 +15 RESISTANCE se = aoa 1.00 + 20 Range(*3) Resolution _| Test Current Accuracy 1 Year (23C5C) TT on 504 z a z 3.00 + 50 m Zo z 00 + 500.009 10mQ. 0.83mA 0.10 + 5 (*4) 50Hz ~ 10kHz 0.35 +15 5.0000kQ 100mQ 0.83mA 0.10 + 3 (*4) 10kHz ~ 30kHz 1.00 + 20 50.000kQ 10 83pA 0.10 +3 30kHz ~ 100kHz 3.00 + 50 500.00kQ 100 8.3pA 0.10+3 500.00V 10mV 30Hz ~ 50Hz 050 15 5,0000MQ 100 830nA 0.10 +3 pohz ~ 10K 1.00 4.20 a 1k 560nA//10MQ 0.30+3 Obras ee Ma 50.000M nA// : 30kHz ~ 100kHz 3.00 + 50 DC CURRENT 750.0V 100mv 30Hz ~ 50Hz Range(*3) Resolution Burden Voltage | Accuracy 1 Year (23C+5C) S0Hz ~1 OkH iz 0.50+15 Z~ Zz no 500.00pA 10nA 0.06Vmax. 0.05 +5 30kHz ~ 100kHz 5.0000mA 100nA 0.6Vmax. 0.05 +4 True RMS AC (or AC+DC AC Coupled) Current (*5*6) 50.000mA pA 0.14Vmax. 0.05 + 4 Range(*3) Resolution | Frequency Accuracy 1 Year (23C+5C) 500.00mA 10pA 1.4Vmax. 0.10+4 500.00pA 10nA 30Hz ~ 50Hz 1.50 + 50 5.0000A 100pA 0.5Vmax. 0.25+5 50Hz ~ 2kHz 0.50 +40 10.000A ImA 0.8Vmax. 0.254+5 2kHz ~ SkHz 1.50+ 50 CONTINUITY 5kHz ~ 20kHz 3.00 + 75 Range(*3) Resolution Test Current Accuracy 1 Year (23C+5C) 5.0000mA 100nA 30Hz ~ 50Hz 1.50 +40 5OHz ~ 2kHz 0.50 + 20 5000.0Q 100mQ. 0.83mA 0.10+5 2kHz ~ 5kHz 150 +40 DIODE TEST (*7) 5kHz ~ 20kHz 3.00 + 60 Range(*3) Resolution Test Current Accuracy 1 Year (23C+5C) 50.000mA pA 30Hz ~ 50Hz 1.50 + 40 5.0000V 100pV 0.83mA 0.05 +5 ae ~ ac eh + 7 Ze Z: i + CAPACITANCE _ 5kHz ~ 20kHz 3.00 + 60 Range(*3) Resolution Test Current Accuracy 1 Year (23C+5C) 500.00mA 10pA 30Hz ~ 50Hz 1.50 + 40 5.000nF :0.5~InF | 0.001nF 8.3pA 2.00 + 20 50Hz ~ 2kHz 0.50 + 20 5.000nF:1~SnF =| 0.001nF 8.3pA 2.00 + 10 2kHz ~ 5kHz 1.50 + 40 50.00nF:5~10nF | 0.01nF 8.3pA 2.00 + 30 SkHz ~ 20kHz 3.00 + 60 50.00nF : 10~50nF | 0.01nF 8.3pA 2.00 + 10 5.0000A 100pA 30Hz ~ 50Hz 2.00 + 40 500.0nF 0.1nF 83pA 2.00 + 4 50Hz ~ 2kHz 0.50 + 30 5.000pF InF 0.56mA 2.00 +4 10.000A 1mA 30 z ~ 50Hz 2.00 + 40 50.00pF 10nF 0.83mA 2.00 + 4 50Hz ~ 2kHz 0.50 + 30 FREQUENCY AND PERIOD CHARACTERISTICS wave) ARA FREQUENCY / PERIOD THERMOCOUPLES Range Accuracy 1 Year (23C+5C) Type Range Resolution Accuracy (*7)1 Year (23C+5C) 10Hz ~ 500Hz 0.01+5 J/T/K -200 C ~ +300 C 0.1 C 2C 500Hz ~ 500kHz 0.01 +3 500kHz ~ IMHz 0.01 +5 Note: The specifications apply when the DMM is warmed up for at least 30 minutes and operates in slow rate. Display VED, Two Colors Display 2, Boewaey + (% of reading + digits) oe Interface USB device, USB Host (GDM-8342 only) 3.2% overrange on all ranges, except 10A.is 20% overrange. Power Source AC 100 V / 120 V / 220 V / 240 V +10%, 50-60Hz 4.REL function ison. 7 Power Consumption Max. 15VA 5. The accuracy of AC+DC is equal to AC with My more digits added. Dimensions & Weight 265 (W) x 107(H) x 302(D) mm, approx. 2.9kg 6. AC Characteristics are for sinewave input > 5% of range. 7. Specifications do not include probe accuracy. Specifications subject to change without notice. DM-8300GD1DH ORDERING INFORMATION OPTION GDM-8342with GPIB 50000 counts Dual Measurement Multimeter with USB Host/Device and opt.01 GPIB Stel eere Inia GDM-8342 50000 counts Dual Measurement Multimeter with USB Host/Device OPTIONAL ASSESSORIES GDM-8341 50000 counts Dual Measurement Multimeter with USB Device GTL-205 Temperature probe adaptor with thermocouple ACCESSORIES (K-type), Approx. 1000mm Safety Instruction Sheet x 1, Power cord x 1, Test lead GTL-207 x 1, CD x 1 GTL-246 USB Cable, A-B type, Approx. 1200mm (including complete user manual, USB driver and PC software) GTL-251 GPIB-USB-HS (high Speed) Global Headquarters GOOD WILL INSTRUMENT CO., LTD. No.7-1, Jhongsing Road, Tucheng Dist., New Taipei City 236, Taiwan T +886-2-2268-0389 F +886-2-2268-0639 E-mail: marketing @ goodwill.com.tw China Subsidiary GOOD WILL INSTRUMENT (SUZ No. 521, Zhujiang Road, Snd, Suzhou Jiangsu 215011 China T +86-512-6661-7177 F +86-512-6661-7277 E-mail: marketing@instek.com.cn Malaysia Subsidiary GOOD WILL INSTRUMENT (M) SDN. BHD. 27, Persiaran Mahsuri 1/1, Sunway Tu 11900 Bayan Lepas, Penang, Malaysia T +604-6309988 F +604-6309989 E-mail: sales@goodwill.com.my U.S.A. Subsidiary INSTEK AMERICA CORP. 3661 Walnut Avenue Chino, CA 91710, U.S.A. T +1-909-5918358 F +1-909-5912280 E-mail: sales@instekamerica.com Japan Subsidiary HOU) CO., LTD. T +81-45-476-5650 F +81-45-476-5653 E-mail: info@instek.co.jp Korea Subsidiary nas, INSTEK JAPAN CORPORATION 2F DSM Shin-Yokohama Bldg, 2-6-3, Shin Yokohama, Kouhoku-ku, Yokohama, Kanagawa 222-0033 Japan GOOD WILL INSTRUMENT KOREA CO., LTD. #1406, Ace Hightech-City B/D 1Dong, Mullae-Dong 3Ga 55-20, Yeongduengpo-Gu, Seoul, Korea T +82-2-3439-2205 F +82-2-3439-2207 E-mail : gwinstek@gwinstek.co.kr GW INSTEK Simply Reliable www.gwinstek.com