110531/7 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice. www.lem.com
Page 1/3
IPN = 3 .. 50 A
Features
Galvanic isolation between
primary and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range (3 x
IPN)
Isolated plastic case recognized
according to UL 94-V0.
Special features
Single supply from +12V to + 15V
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Application domain
Industrial.
Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal Primary current Primary conductor Type
current rms measuring range1) diameter x turns
IPN (A) IPM (A) (mm)
3 ± 9 0.6d x 20T HX 03-P/SP2
5 ± 15 0.8d x 12T HX 05-P/SP2
10 ± 30 1.1d x 6T HX 10-P/SP2
15 ± 45 1.4d x 4T HX 15-P/SP2
20 ± 60 1.6d x 3T HX 20-P/SP2
25 ± 75 1.6d x 2T HX 25-P/SP2
50 ± 150 1.2 x 6.3 x 1T HX 50-P/SP2
VOUT Output voltage (Anarog) @ ± IPN, RL = 2 kW, TA = 25 °C VCE ± 0.625 V
ROUT Output internal resistance < 50 W
RL Load resistance ≥ 2 kW
VC Supply voltage (± 5 %) + 12 .. 15 V
VC Current consumption < 15 mA
X Accuracy @ IPN , TA = 25°C (xcluding offset) < ± 1 % of IPN
Accuracy - Dynamic performance data
εL Linearity error (0 .. ± IPN) < ± 1 % of IPN
VOE Electorical offset voltage @ IP = 0, TA = 25°C
+ 2.5V ± 50
m V
VOH Hysteresis offset voltage @ IP = 0
after an excursion of 1 x IPN < ± 10 mV
TCVOE Temperature coefcient of VOE < ± 1.5 mV/K
TCVOH Temerature coefcient of VOUT (% of reading) ± 0.1 %/K
tr Response time to 90% of IPN step 3 µs
BW Frequency bandwidth (- 3 dB) 2) 50 kHz
TA Ambient operating temperature - 25 .. + 85 °C
General data
TS Ambient storage temperature - 25 .. + 85 °C
m Mass ... 8 g
Standards EN 50178: 1997
Note: 1) With R L=2kW
2) Small signal only to avoid excssive heating of the magnetic cores.
All data are given with RL = 2 kW
110531/7 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice. www.lem.com
Page 2/3
Current Transducer HX 03..50-P/SP2
Isolation characteristics
Vd Rms voltage for AC isolation test, 50 Hz, 1 min > 3 kV
Ve Partial discharge extinction voltage rms @ 10 pC ≥ 1 kV
Vw Impulse withstand voltage 1.2/50 µs ≥ 6 kV
dCp Creepage distance ≥ 5.5 mm
dCI Clearance distance ≥ 5.5 mm
CTI Comparative Tracking Index (group I) ≥ 600
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
Over voltage category OV 3
Pollution degree PD2
Non-uniform eld
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturers operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
EN 50178 IEC 61010-1
dCp, dCI, Rated insulation voltage Nominal voltage
Basic insulation 600 V 600 V
Reinforced insulation 300 V 150 V
Vw
110531/7 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice. www.lem.com
Page 3/3
Dimensions HX 03..50-P/SP2 (in mm. 1 mm = 0.0394 inch)
Mechanical characteristics
General tolerance ± 0.5 mm
3
19 Max.
0.5
20Max.
3-P=2.54
1
2
3
4
+V
OUT 65
8.8 5.4
1.3
5
-V or 0
0
3.5
3
HX 50-P
3 8.8 5.4
1.2
3
19 Max.
0.5
20Max.
3-P=2.54
1
2
3
4
+V
OUT
5
-V or 0
0
3.5
3
10.85
3.5
d
10.85
6
6
15.4 Max.
15.4 Max.
Top view
Lot No.
HX 05-P
41123
HX 03...25-P
Terminal Pin Identification
1 ..... -15 V
2 ..... 0 V
3 ..... +15 V
4 ..... Output
5 ..... Primary input Current (+)
6 ..... Primary input Current (-)
Primary conductor diameter
Secondary pins dimension
0.5 x 0.25
HX 03..25-P
HX 50-P
HX 03-P 05-P 10-P 15-P
d0.6 0.8 1.1 1.4
HX 20-P 25-P 50-P
d1.6 1.6 1.2 x 6.3
410123
CN2
HX 05-P/SP2
HX 50-P/SP2HX 50-P/SP2
HX 03 .. 25-P/SP2HX 03 .. 25-P/SP2
03-P
/SP2
05-P
/SP2
10-P
/SP2
15-P
/SP2
20-P
/SP2
25-P
/SP2
50-P
/SP2
0 V