110531/7 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice. www.lem.com
Page 1/3
IPN = 3 .. 50 A
Features
● Galvanic isolation between
primary and secondary circuit
● Hall effect measuring principle
● Isolation voltage 3000V
● Low power consumption
● Extended measuring range (3 x
IPN)
● Isolated plastic case recognized
according to UL 94-V0.
Special features
● Single supply from +12V to + 15V
Advantages
● Low insertion losses
● Easy to mount with automatic
handling system
● Small size and space saving
● Only one design for wide current
ratings range
● High immunity to external
interference
Applications
● Switched Mode Power Supplies
(SMPS)
● AC variable speed drives
● Uninterruptible Power Supplies
(UPS)
● Electrical appliances
● Battery supplied applications
●DC motor drives
Application domain
● Industrial.
Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal Primary current Primary conductor Type
current rms measuring range1) diameter x turns
IPN (A) IPM (A) (mm)
3 ± 9 0.6d x 20T HX 03-P/SP2
5 ± 15 0.8d x 12T HX 05-P/SP2
10 ± 30 1.1d x 6T HX 10-P/SP2
15 ± 45 1.4d x 4T HX 15-P/SP2
20 ± 60 1.6d x 3T HX 20-P/SP2
25 ± 75 1.6d x 2T HX 25-P/SP2
50 ± 150 1.2 x 6.3 x 1T HX 50-P/SP2
VOUT Output voltage (Anarog) @ ± IPN, RL = 2 kW, TA = 25 °C VCE ± 0.625 V
ROUT Output internal resistance < 50 W
RL Load resistance ≥ 2 kW
VC Supply voltage (± 5 %) + 12 .. 15 V
VC Current consumption < 15 mA
X Accuracy @ IPN , TA = 25°C (xcluding offset) < ± 1 % of IPN
Accuracy - Dynamic performance data
εL Linearity error (0 .. ± IPN) < ± 1 % of IPN
VOE Electorical offset voltage @ IP = 0, TA = 25°C
+ 2.5V ± 50
m V
VOH Hysteresis offset voltage @ IP = 0
after an excursion of 1 x IPN < ± 10 mV
TCVOE Temperature coefcient of VOE < ± 1.5 mV/K
TCVOH Temerature coefcient of VOUT (% of reading) ± 0.1 %/K
tr Response time to 90% of IPN step ≤ 3 µs
BW Frequency bandwidth (- 3 dB) 2) 50 kHz
TA Ambient operating temperature - 25 .. + 85 °C
General data
TS Ambient storage temperature - 25 .. + 85 °C
m Mass ... 8 g
Standards EN 50178: 1997
Note: 1) With R L=2kW
2) Small signal only to avoid excssive heating of the magnetic cores.
All data are given with RL = 2 kW