Data Sheet ACD-15 TRMS-PRO 2000A Clamp-on Multimeter Wide range of measuring features built into one, professional meter. The TRMS version with backlight display, improves performance and reliability. True RMS Auto Backlight Low Measurements: Data AC/DC Voltage up to 600V, AC Current up to 2000A Resistance, Frequency and Capacitance Non-contact Voltage Level Detection Audible continuity Auto-check feature automatically selects DCV, ACV or Resistance (W) power off battery indication hold Large, easy to read LCD display Accommodates conductors up to 45mm (1.77") in diameter Carrying case, test leads, batteries (installed) and manual included Voltage overload protection for all functions up to 600V AC/DC No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: $500 MSLP limit) 600V Amprobe(R) Test Tools www.Amprobe.com Data Sheet ACD-15 TRMS-PRO 2000A Digital Clamp-on Multimeters Electrical Specifications Accuracy is (% reading digits + number of digits) or otherwise specified, at 23 5 & less than 75% R.H. True RMS Model ACD-15 TRMS-PRO ACV & ACA clamp-on accuracies are specified from 5% to 100% of range or otherwise specified. Maximum Crest Factor are as specified below, and with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms. Function Range Accuracy DC Voltage 6.000V 0.5% + 3d 60.00V 1.0% + 5d 600.0V 2.0% + 5d NMRR : >30dB @ 50/60Hz CMRR : >100dB @ DC, 50/60Hz, Rs=1kW Hi-Z DCV Input Impedance: 5MW, 90pF nominal AutoCheckTM Lo-Z DCV input impedance: Initially 1.6kW, 90pF nominal; Impedance increases significantly as display voltage increases from 50V (typical). Typical impedances vs display voltages for reference are: 15kW @ 100V; 100kW @ 300V; 210kW @ 600V AutoCheckTM DCV Threshold: > +1.5VDC or < -1.0VDC nominal AC Voltage 50Hz / 60Hz 6.000V, 60.00V 1.5% + 5d 600.0V 2.0% + 5d 50Hz ~ 500Hz 6.000V, 60.00V 2.0% + 5d 600.0V 2.5% + 5d CMRR: >60dB @ DC to 60Hz, Rs=1kW Hi-Z ACV Input Impedance: 5MW, 90pF nominal AutoCheckTM Lo-Z ACV input impedance: Initially 1.6kW, 90pF nominal; Impedance increases significantly as display voltage increases from 50V (typical). Typical impedances vs display voltages for reference are: 5kW @ 100V; 100kW @ 300V; 210kW @ 600V AutoCheckTM ACV Threshold: > 2VAC (50/60Hz) nominal. True RMS model ACD-15 TRMS-PRO Crest < 1.6 : 1 at full scale & < 3.3 : 1 at half scale Resistance 6.000kW 2) 1.2% + 6d 1) 3) 60.00kW, 600.0kW 1.0% + 4d 6.000MW 2.0% + 4d 1) Cool down interval 2 minutes after over 50V measurements in Auto-VW position Open Circuit Voltage: 0.4VDC typical 2) Beeper on while reading < 0.025kW 3) Add 40d to specified accuracy while reading is 600W with Continuity Beeper 600.0W 2.0%+8d 1) Continuity Beeper Response: < 100s Open Circuit Voltage: 0.4VDC typical Audible Threshold: between 10W and 300W 1) Add 40d to specified accuracy while reading is below 20% of range Frequency Range Sensitivity (Sine RMS) Voltage Range 10Hz ~ 30kHz 4V 6.000V 0Hz ~ 1kHz 30V 1 60.00V 10Hz ~ 1kHz 60V 600.0V Accuracy: 0.5%+4d Max display: 9999 counts Amprobe(R) Test Tools www.Amprobe.com ACD-15 TRMS-PRO 2000A Digital Clamp-on Multimeters Function Range Data Sheet Accuracy Diode Tester Open Circuit Voltage Test Current < 1.6 VDC 0.4mA (typical) Audible Threshold: between 0.015V & 0.080V Capacitance 100.0nF 2), 1000nF, 3.5%+5d 1) 3) 10.00F, 100.0F, 2000F 1) Accuracies with film capacitor or better 2) Accuracy below 50nF is not specified 3) Specified with battery voltage above 2.8V (approxmately half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V Non-Contact EF-Detection Typical Voltage Bar Graph Indication 15V TO 85V 40V TO 130V - 60V TO 210V -- 90V TO 300V --- ABOVE 120V ---- Indication: Bar graph segments & audible beep tones proportional to the field strength Detection Frequency: 50/60Hz Detection Antenna: Top side of the stationary jaw Probe-Contact EF-Detection: For more precise indication of live wires, use the Red (+) probe for direct contact measurements AC Current (Clamp-on) 50Hz / 60Hz 400.0A, 2000A 1.5% + 5d 1) 2) 3) True RMS model ACD-15 TRMS PRO Crest Factor: < 2.0 : 1 at full scale & < 4.0 : 1 at half scale 1) Add 8d to specified accuracy while reading is below 10% of range 2) Induced error from adjacent current-carrying conductor: < 0.06A/A 3) Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% to specified accuracy for measurements made within jaw marking lines (away from jaw opening) Add 4% to specified accuracy for measurements made beyond jaw marking lines (toward jaws opening) www.Amprobe.com ACD-15 TRMS-PRO 2000A Digital Clamp-on Multimeters Data Sheet General Specifications Display: Update Rate: Polarity: Low Battery: Operating Temperature: Relative Humidity: Altitude: Storage Temperature: Temperature Coefficient: Sensing: Safety: Transient Protection: Pollution Degree: E.M.C.: In an RF field of 3V/m: Overload Protections: Power Supply: Power Consumption: APO Timing: APO Consumption: Dimension: Weight: Jaw opening & Conductor Diameter: 3-5/6 digits 6000 counts LCD display 5 per second nominal Automatic Below approx. 2.4V 0C to 40C Maximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C Operating below 2000m -20 to 60, < 80% R.H. (with battery removed) nominal 0.15 x (specified accuracy)/ @(0 -18 or 28 -40), or otherwise specified Average sensing Meets EN61010-1:2001; IEC61010-2-032(1994), EN61010-2-032(1995), UL3111-2-032(1999). Category III 600 Volts AC & DC 6.5kV (1.2/50s surge) for all models 2 Meets EN61326-1 Capacitance function is not specified. Total Accuracy = Specified Accuracy + 45 digits Performance above 3V/m is not specified ACA Clamp-on jaws: AC 2000A rms continuous + & COM terminals (all functions): 600VDC/VAC RMS standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2 2.8mA typical Idle for 3 minutes 40A typical on all model functions voltage & current functions L224mm X W78mm X H40mm 220 gm approx 45mm max Included Accessories Test leads, carrying case and users manual Optional Accessories ELS2A Line splitter (Energizer) ACF-3000AK 3000A AC Flexible Clamp-On Attachment TMA-K Temperature Adapter TL36A Industry Test Leads with Threaded Alligator Clips Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2007 Amprobe Test Tools. All rights reserved. 9/2007 3128821 Rev A Amprobe(R) Test Tools www.Amprobe.com