XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO SEPTEMBER 2008 REV. 1.0.0 GENERAL DESCRIPTION The XR16M5801 (M580) is an enhanced Universal Asynchronous Receiver and Transmitter (UART) with 16 bytes of transmit and receive FIFOs, selectable transmit and receive FIFO trigger levels, automatic hardware and software flow control, and data rates of up to 16 Mbps at 3.3V, 12.5 Mbps at 2.5V and 7.5 Mbps at 1.8V with 4X data sampling rate. The Auto RS-485 Half-Duplex Direction control feature simplifies both the hardware and software for half-duplex RS-485 applications. In addition, the Multidrop mode with Auto Address detection increases the performance by simplifying the software routines. The Independent TX/RX Baud Rate Generator feature allows the transmitter and receiver to operate at different baud rates. Power consumption of the M580 can be minimized by enabling the sleep mode and PowerSave mode. The M580 has a 16550 compatible register set that provide users with operating status and control, receiver error indications, and modem serial interface controls. An internal loopback capability allows onboard diagnostics. The M580 is available in 32-pin QFN, 48-pin TQFP and 25-pin BGA packages. All three packages offer both the 16 mode (Intel bus) interface and the 68 mode (Motorola bus) interface which allows easy integration with Motorola processors. NOTE: 1 Covered by U.S. Patent #5,649,122. FEATURES * Pin-to-pin compatible with XR16L580 in 32-QFN and 48-TQFP packages * Intel or Motorola Bus Interface select * 16Mbps maximum data rate * Selectable TX/RX trigger levels * TX/RX FIFO Level Counters * Independent TX/RX Baud Rate Generator * Fractional Baud Rate Generator * Auto RTS/CTS Hardware Flow Control * Auto XON/XOFF Software Flow Control * Auto RS-485 Half-Duplex Direction Control * Multidrop mode w/ Auto Address Detect * Sleep Mode with Automatic Wake-up * PowerSave mode * Infrared (IrDA 1.0 and 1.1) mode * 1.62V to 3.63V supply operation * Crystal oscillator or external clock input APPLICATIONS * Personal Digital Assistants (PDA) * Cellular Phones/Data Devices * Battery-Operated Devices * Global Positioning System (GPS) * Bluetooth FIGURE 1. XR16M580 BLOCK DIAGRAM VCC (1.62 to 3.63 V) Pw rSave A2:A0 G ND D7:D0 IOR# UART IOW # (R/W #) UART CS# INT (IRQ#) RESET (RESET#) 16/68# Regs Intel or M otorola Data Bus Interface BRG 16 Byte TX FIFO TX & RX IR ENDEC TX, RX, RTS#, CTS#, DTR#, DSR#, RI#, CD# 16 Byte RX FIFO Crystal Osc/Buffer XTAL1 XTAL2 Exar Corporation 48720 Kato Road, Fremont CA, 94538 * (510) 668-7000 * FAX (510) 668-7017 * www.exar.com XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 DSR# CD# RI# VCC D0 D1 D2 D3 CTS# RESET DTR# RTS# INT A0 A1 A2 CTS# RESET# DTR# RTS# IRQ# A0 A1 A2 FIGURE 2. PIN OUT ASSIGNMENT FOR 32-PIN QFN AND 48-PIN TQFP PACKAGES IN 16 AND 68 MODE 24 23 22 21 20 19 18 17 24 23 22 21 20 19 18 17 25 26 27 28 29 30 31 32 16 15 14 13 12 11 10 9 32- pin QFN in Intel Bus Mode NC NC IOR # GND IOW # XTAL 2 XTAL 1 PwrSave DSR# CD# RI# VCC D0 D1 D2 D3 25 26 27 28 29 30 31 32 32-pin QFN in Motorola Bus Mode VCC D4 16/68# D5 D6 D7 RX TX CS# D4 16/68# D5 D6 D7 RX TX CS GND NC RESET NC DTR# RTS# NC INT NC A0 A1 A2 NC NC RESET# NC DTR# RTS# NC IRQ# NC A0 A1 A2 NC VCC 36 35 34 33 32 31 30 29 28 27 26 25 24 37 38 23 39 22 40 21 41 20 48-TQFP in Intel Bus Mode 42 43 19 18 44 17 45 16 46 15 47 14 3 4 5 6 7 8 13 9 10 11 12 NC NC NC NC NC IOR# GND NC IOW# XTAL2 XTAL1 PwrSave NC CTS# DSR# CD# RI# VCC D0 D1 D2 D3 D4 NC 36 35 34 33 32 31 30 29 28 27 26 25 37 24 38 23 39 22 40 21 41 42 43 48-TQFP in Motorola Bus Mode 20 19 18 44 17 45 16 46 15 47 48 1 2 14 3 4 5 6 7 8 13 9 10 11 12 16/68# D5 D6 D7 NC NC RX TX NC NC CS# NC 16/68# D5 D6 D7 NC NC RX TX NC NC CS# NC 48 1 2 NC NC IOR# GND R/W# XTAL 2 XTAL 1 PwrSave 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 NC CTS# DSR# CD# RI# VCC D0 D1 D2 D3 D4 NC 16 15 14 13 12 11 10 9 GND VCC 2 NC NC NC NC NC IOR# GND VCC NC R/W# XTAL2 XTAL1 PwrSave XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 3. PIN OUT ASSIGNMENT FOR 25-PIN BGA PACKAGE A1 Corner 1 2 3 4 5 A B C D E Transparent Top View CTS# VCC RESET 16/68# INT RTS# A1 A0 A2 IOR# D0 D3 D6 D1 D7 TX PwrSave CS# IOW# XTAL1 D4 D2 D5 RX GND ORDERING INFORMATION PART NUMBER PACKAGE OPERATING TEMPERATURE RANGE DEVICE STATUS XR16M580IL32 32-PinQFN -40C to +85C Active XR16M580IM48 48-Lead TQFP -40C to +85C Active XR16M580IB25 25-Pin BGA -40C to +85C Active 3 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 PIN DESCRIPTIONS Pin Description NAME 32-QFN 48-TQFP 25-BGA PIN# PIN# PIN# TYPE DESCRIPTION Address lines [2:0]. These 3 address lines select the internal registers in UART channel during a data bus transaction. DATA BUS INTERFACE A2 A1 A0 17 18 19 26 27 28 A5 A4 B4 I D7 D6 D5 D4 D3 D2 D1 D0 5 4 3 1 32 31 30 29 4 3 2 47 46 45 44 43 C3 C2 E3 E1 D1 E2 D2 C1 I/O IOR# 14 19 B5 I When 16/68# pin is at logic 1, the Intel bus interface is selected and this input becomes read strobe (active low). The falling edge instigates an internal read cycle and retrieves the data byte from an internal register pointed by the address lines [A2:A0], puts the data byte on the data bus to allow the host processor to read it on the rising edge. When 16/68# pin is at logic 0, the Motorola bus interface is selected and this input should be connected to VCC. IOW# (R/W#) 12 16 C5 I When 16/68# pin is at logic 1, it selects Intel bus interface and this input becomes write strobe (active low). The falling edge instigates the internal write cycle and the rising edge transfers the data byte on the data bus to an internal register pointed by the address lines. When 16/68# pin is at logic 0, the Motorola bus interface is selected and this input becomes read (logic 1) and write (logic 0) signal. CS# 8 11 D4 I This input is chip select (active low) to enable the device. INT (IRQ#) 20 30 A3 Data bus lines [7:0] (bidirectional). O When 16/68# pin is at logic 1 for Intel bus interface, this output (OD) become the active high device interrupt output. The output state is defined by the user through the software setting of MCR[3]. INT is set to the active mode when MCR[3] is set to a logic 1. INT is set to the three state mode when MCR[3] is set to a logic 0. See MCR[3]. When 16/68# pin is at logic 0 for Motorola bus interface, this output becomes the active low device interrupt output (open drain). An external pull-up resistor is required for proper operation. MODEM OR SERIAL I/O INTERFACE TX 7 8 D3 O UART Transmit Data or infrared encoder data. Standard transmit and receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be a logic 1 during reset or idle (no data). Infrared IrDA transmit and receive interface is enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the Infrared encoder/decoder interface is a logic 0. If it is not used, leave it unconnected. 4 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 Pin Description NAME 32-QFN 48-TQFP 25-BGA PIN# PIN# PIN# DESCRIPTION TYPE RX 6 7 E4 I UART Receive Data or infrared receive data. Normal receive data input must idle at logic 1 condition. The infrared receiver idles at logic 0. This input should be connected to VCC when not used. RTS# 21 32 B3 O UART Request-to-Send (active low) or general purpose output. This output must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1] and IER[6]. CTS# 24 38 A1 I UART Clear-to-Send (active low) or general purpose input. It can be used for auto CTS flow control, see EFR[7], MSR[4] and IER[7]. This input should be connected to VCC when not used. DTR# 22 33 - O UART Data-Terminal-Ready (active low) or general purpose output. DSR# 25 39 - I UART Data-Set-Ready (active low) or general purpose input. This input should be connected to VCC when not used. CD# 26 40 - I UART Carrier-Detect (active low) or general purpose input. This input should be connected to VCC when not used. RI# 27 41 - I UART Ring-Indicator (active low) or general purpose input. This input should be connected to VCC when not used. ANCILLARY SIGNALS XTAL1 10 14 D5 I Crystal or external clock input. XTAL2 11 15 - O Crystal or buffered clock output. PwrSave 9 13 C4 I Power-Save (active high). This feature isolates the M580's data bus interface from the host preventing other bus activities that cause higher power drain during sleep mode. See Sleep Mode with Auto Wake-up and Power-Save Feature section for details. This pin does not have an internal pull-down resistor. This input should be connected to GND when not used. 16/68# 2 1 B2 I Intel or Motorola Bus Select. When 16/68# pin is at logic 1, 16 or Intel Mode, the device will operate in the Intel bus type of interface. When 16/68# pin is at logic 0, 68 or Motorola mode, the device will operate in the Motorola bus type of interface. This pin does not have an internal pull-up or pull-down resistor. RESET (RESET#) 23 35 A2 I When 16/68# pin is at logic 1 for Intel bus interface, this input becomes RESET (active high). When 16/68# pin is at logic 0 for Motorola bus interface, this input becomes RESET# (active low). A 40 ns minimum active pulse on this pin will reset the internal registers and all outputs of the UART. The UART transmitter output will be held at logic 1, the receiver input will be ignored and outputs are reset during reset period (see UART Reset Conditions). VCC 28 42 B1 Pwr 1.62V to 3.63V power supply. GND 13 18 E5 Pwr Power supply common, ground. GND Center Pad - - Pwr The center pad on the backside of the QFN package is metallic and should be connected to GND on the PCB. The thermal pad size on the PCB should be the approximate size of this center pad and should be solder mask defined. The solder mask opening should be at least 0.0025" inwards from the edge of the PCB thermal pad. 5 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 Pin Description NAME NC 32-QFN 48-TQFP 25-BGA PIN# PIN# PIN# 15, 16 5, 6, 9, 10, 12, 17, 2025, 29, 31, 34, 36, 37, 48 DESCRIPTION TYPE - No Connects. - Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain. 1.0 PRODUCT DESCRIPTION The XR16M580 (M580) is a high performance single channel UART. The configuration registers set is 16550 UART compatible for control, status and data transfer. Additionally, the M580 channel has 16 bytes of transmit and receive FIFOs, Automatic RTS/CTS Hardware Flow Control, Automatic Xon/Xoff and Special Character Software Flow Control, infrared encoder and decoder (IrDA ver 1.0 and 1.1), programmable fractional baud rate generator with a prescaler of divide by 1 or 4, and data rate up to 16 Mbps. The XR16M580 can operate from 1.62 to 3.63 volts. The M580 is fabricated with an advanced CMOS process. Data Rate The M580 is capable of operation up to 16 Mbps at 3.3V with 4X internal sampling clock rate. The device can operate at 3.3V with a 24 MHz crystal on pins XTAL1 and XTAL2, or external clock source of 32 MHz on XTAL1 pin. With a typical crystal of 14.7456 MHz and through a software option, the user can set the prescaler bit and sampling rate for data rates of up to 3.68 Mbps. Enhanced Features The rich feature set of the M580 is available through the internal registers. Automatic hardware/software flow control, selectable transmit and receive FIFO trigger levels, selectable baud rates, infrared encoder/decoder, modem interface controls, and a sleep mode are all standard features. MCR bit-5 provides a facility for turning off (Xon) software flow control with any incoming (RX) character. The M580 includes new features such as 9-bit (Multidrop) mode, auto RS-485 half-duplex direction control, different baud rate for TX and RX, fast IR mode and fractional baud rate generator. 6 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 2.0 FUNCTIONAL DESCRIPTIONS 2.1 CPU Interface The CPU interface is 8 data bits wide with 3 address lines and control signals to execute data bus read and write transactions. The M580 data interface supports the Intel and motorola compatible types of CPUs. No clock (oscillator nor external clock) is required for a data bus transaction. Each bus cycle is asynchronous using CS#, IOR# and IOW# or R/W# inputs. A typical data bus interconnection for Intel and Motorola mode is shown in Figure 4. FIGURE 4. XR16M580 TYPICAL INTEL/MOTOROLA DATA BUS INTERCONNECTIONS D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A0 A1 A2 IOR# IOR# IOW# IOW# VCC 16/68# VCC TX RX DTR# RTS# CTS# Serial Transceivers of RS-232 RS-485 RS-422 Or Infrared DSR# CD# CS# UART_CS# UART_INT INT POWERSAVE PwrSave UART_RESET RESET RI# GND Intel Data Bus Interconnections D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 VCC A0 A1 A2 A0 A1 DTR# A2 TX RX RTS# IOR# CTS# R/W# IOW# DSR# UART_CS# CS# CD# NC vcc RI# UART_IRQ# INT POWERSAVE PwrSave UART_RESET# RESET 16/68# GND Motorola Data Bus Interconnections 7 VCC Serial Transceivers of RS-232 RS-485 RS-422 Or Infrared XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 2.2 REV. 1.0.0 Serial Interface The M580 is typically used with RS-232, RS-485 and IR transceivers. The following figure shows typical connections from the UART to the different transceivers. For more information on RS-232 and RS-485/422 transceivers, go to www.exar.com or send an e-mail to uarttechsupport@exar.com. FIGURE 5. XR16M580 TYPICAL SERIAL INTERFACE CONNECTIONS VCC UART VCC R S -2 3 2 T r a n s c e iv e r TX T 1 IN RX R1OUT DTR# T 2 IN RTS# T 3 IN CTS# R2O UT DSR# R 3O U T CD# R 4O U T R I# R 5O UT GND GND R S - 2 3 2 F u ll -M o d e m S e r ia l In te r fa c e VCC VCC TX DI RO RX UART RS-485 Transceiver Full-duplex RTS# NC DTR# NC TX+ TX- VCC VCC RX+ DE CTS# RXRE# DSR# CD# RI # GND RS-485 Full-Duplex Serial Interface 8 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 6. XR16M580 TYPICAL SERIAL INTERFACE CONNECTIONS VCC VCC TX DI RX RO Y Z DE RTS# UART RS-485 Transceiver Half-duplex VCC NC DTR# A RE# CTS# B DSR# CD# RI # GND RS-485 Half-Duplex Serial Interface VCC UART IR T ransceiver VCC TX TXD RX RXD DTR# NC RTS# NC VCC CTS# D SR # CD# R I# GND Infrared C on nection 9 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 2.3 REV. 1.0.0 Device Reset The RESET input resets the internal registers and the serial interface outputs to their default state (see Table 16). An active high pulse of longer than 40 ns duration will be required to activate the reset function in the device. Following a power-on reset or an external reset, the M580 is software compatible with previous generation of UARTs, XR16L580 and ST16C550. 2.4 Internal Registers The M580 has a set of 16550 compatible registers for controlling, monitoring and data loading and unloading. These registers function as data holding registers (THR/RHR), interrupt status and control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/LCR), modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/DLM/DLD), and a user accessible scratchpad register (SPR). Beyond the general 16C550 features and capabilities, the M580 offers enhanced feature registers (EFR, Xon1/ Xoff 1, Xon2/Xoff 2, DLD, FCTR, EMSR and FC) that provide automatic RTS and CTS hardware flow control, automatic Xon/Xoff software flow control, 9-bit (Multidrop) mode, auto RS-485 half duplex control, different baud rate for TX and RX and fractional baud rate generator. All the register functions are discussed in full detail later in "Section 3.0, UART INTERNAL REGISTERS" on page 24. 2.5 INT Ouput The interrupt outputs change according to the operating mode and enhanced features setup. Table 1 and 2 summarize the operating behavior for the transmitter and receiver. Also see Figure 22 through 25. NOTE: The IRQ# pin requires a pull-up resistor for proper operation. TABLE 1: INT PIN OPERATION FOR TRANSMITTER FCR BIT-0 = 0 (FIFO DISABLED) FCR BIT-0 = 1 (FIFO ENABLED) INT Pin (16/68# = 1) LOW = One byte in THR HIGH = THR empty LOW = FIFO above trigger level HIGH = FIFO below trigger level or FIFO empty IRQ# Pin (16/68# = 0) HIGH = One byte in THR LOW = THR empty HIGH = FIFO above trigger level LOW = FIFO below trigger level or FIFO empty TABLE 2: INT PIN OPERATION FOR RECEIVER FCR BIT-0 = 0 (FIFO DISABLED) FCR BIT-0 = 1 (FIFO ENABLED) INT Pin (16/68# = 1) HIGH = One byte in RHR LOW = RHR empty LOW = FIFO below trigger level HIGH = FIFO above trigger level or RX Data Timeout IRQ# Pin (16/68# = 0) LOW = One byte in RHR HIGH = RHR empty HIGH = FIFO below trigger level LOW = FIFO above trigger level or RX Data Timeout 10 XR16M580 REV. 1.0.0 2.6 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO Crystal Oscillator or External Clock Input The M580 includes an on-chip oscillator to produce a clock for the baud rate generators in the device when a crystal is connected between XTAL1 and XTAL2 as show below. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a system clock to the Baud Rate Generators (BRGs) in the UART. XTAL1 is the input to the oscillator or external clock buffer input with XTAL2 pin being the output. For programming details, see "Section 2.7, Programmable Baud Rate Generator with Fractional Divisor" on page 12. FIGURE 7. TYPICAL CRYSTAL CONNECTIONS XTAL1 XTAL2 R2 500K - 1M Y1 C1 22-47pF R1 0-120 (Optional) 1.8432 MHz to 24 MHz C2 22-47pF The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant, fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100ppm frequency tolerance) connected externally between the XTAL1 and XTAL2 pins. Typical oscillator connections are shown in Figure 7. Alternatively, an external clock can be connected to the XTAL1 pin to clock the internal baud rate generator for standard or custom rates. The BGA package has XTAL1 only, the external clock is required. For further reading on oscillator circuit, see application note DAN108 on EXAR's web site. 11 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 2.7 REV. 1.0.0 Programmable Baud Rate Generator with Fractional Divisor The M580 has independent Baud Rate Generators (BRGs) with prescalers for the transmitter and receiver. The prescaler is controlled by a software bit in the MCR register. The MCR register bit-7 sets the prescaler to divide the input crystal or external clock by 1 or 4. The output of the prescaler clocks to the BRG. The BRG further divides this clock by a programmable divisor between 1 and (216 - 0.0625) in increments of 0.0625 (1/ 16) to obtain a 16X or 8X or 4X sampling clock of the serial data rate. The sampling clock is used by the transmitter for data bit shifting and receiver for data sampling. For transmitter and receiver, the M580 provides respective BRG divisors. The BRG divisor (DLL, DLM, and DLD registers) defaults to the value of '1' (DLL = 0x01, DLM = 0x00 and DLD = 0x00) upon reset. Therefore, the BRG must be programmed during initialization to the operating data rate. The DLL and DLM registers provide the integer part of the divisor and the DLD registers provides the fractional part of the divisor. The four lower bits of the DLD are used to select a value from 0 (for setting 0000) to 0.9375 or 15/16 (for setting 1111). Programming the Baud Rate Generator Registers DLL, DLM and DLD provides the capability for selecting the operating data rate. Table 3 shows the standard data rates available with a 24MHz crystal or external clock at 16X clock rate. If the pre-scaler is used (MCR bit-7 = 1), the output data rate will be 4 times less than that shown in Table 3. At 8X sampling rate, these data rates would double. And at 4X sampling rate, they would quadruple. Also, when using 8X sampling mode, please note that the bit-time will have a jitter (+/- 1/16) whenever the DLD is non-zero and is an odd number. When using a non-standard data rate crystal or external clock, the divisor value can be calculated with the following equation(s): Required Divisor (decimal)=(XTAL1 clock frequency / prescaler) /(serial data rate x 16), with 16X mode, DLD[5:4]='00' Required Divisor (decimal)= (XTAL1 clock frequency / prescaler / (serial data rate x 8), with 8X mode, DLD[5:4] = '01' Required Divisor (decimal)= (XTAL1 clock frequency / prescaler / (serial data rate x 4), with 4X mode, DLD[5:4] = '10' The closest divisor that is obtainable in the M580 can be calculated using the following formula: ROUND( (Required Divisor - TRUNC(Required Divisor) )*16)/16 + TRUNC(Required Divisor), where DLM = TRUNC(Required Divisor) >> 8 DLL = TRUNC(Required Divisor) & 0xFF DLD = ROUND( (Required Divisor-TRUNC(Required Divisor) )*16) In the formulas above, please note that: TRUNC (N) = Integer Part of N. For example, TRUNC (5.6) = 5. ROUND (N) = N rounded towards the closest integer. For example, ROUND (7.3) = 7 and ROUND (9.9) = 10. A >> B indicates right shifting the value 'A' by 'B' number of bits. For example, 0x78A3 >> 8 = 0x0078. 2.7.1 Independent TX/RX BRG The XR16M580 has two independent sets of TX and RX baud rate generator. Please see the Figure 8. TX and RX can work in different baud rate by setting DLD, DLL and DLM register. For example, TX can transmit data to the remote UART at 9600 bps while RX receives data from remote UART at 921.6 Kbps. For the baud rate setting, please See "Section 4.13, Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write" on page 38.. 12 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 8. BAUD RATE GENERATOR DLD[7]=0 Prescaler Divide by 1 XTAL1 XTAL2 Crystal Osc / Buffer MCR Bit -7= 0 (default) 16X or 8X or 4X Sampling Rate Clock to Transmitter DLL DLM DLD[5:0] 0 Prescaler Divide by 4 MCR Bit -7=1 DLD[7]=1 DLL DLM DLD[5:0] 16X or 8X or 4X Sampling Rate Clock to Receiver 1 DLD[6] TABLE 3: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING Required Output Data Rate DIVISOR FOR 16x Clock (Decimal) DIVISOR OBTAINABLE IN M580 DLM PROGRAM VALUE (HEX) DLL PROGRAM VALUE (HEX) DLD PROGRAM VALUE (HEX) DATA ERROR RATE (%) 400 3750 3750 E A6 0 0 2400 625 625 2 71 0 0 4800 312.5 312 8/16 1 38 8 0 9600 156.25 156 4/16 0 9C 4 0 10000 150 150 0 96 0 0 19200 78.125 78 2/16 0 4E 2 0 25000 60 60 0 3C 0 0 28800 52.0833 52 1/16 0 34 1 0.04 38400 39.0625 39 1/16 0 27 1 0 50000 30 30 0 1E 0 0 57600 26.0417 26 1/16 0 1A 1 0.08 75000 20 20 0 14 0 0 100000 15 15 0 F 0 0 115200 13.0208 13 0 D 0 0.16 153600 9.7656 9 12/16 0 9 C 0.16 200000 7.5 7 8/16 0 7 8 0 225000 6.6667 6 11/16 0 6 B 0.31 230400 6.5104 6 8/16 0 6 8 0.16 250000 6 6 0 6 0 0 300000 5 5 0 5 0 0 400000 3.75 3 12/16 0 3 C 0 460800 3.2552 3 4/16 0 3 4 0.16 500000 3 3 0 3 0 0 750000 2 2 0 2 0 0 921600 1.6276 1 10/16 0 1 A 0.16 1000000 1.5 1 8/16 0 1 8 0 13 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 2.8 REV. 1.0.0 Transmitter The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 16 bytes of FIFO which includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X/8X/4X internal clock. A bit time is 16/8/4 clock periods. The transmitter sends the start-bit followed by the number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The status of the FIFO and TSR are reported in the Line Status Register (LSR bit-5 and bit-6). 2.8.1 Transmit Holding Register (THR) - Write Only The transmit holding register is an 8-bit register providing a data interface to the host processor. The host writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits, parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input register to the transmit FIFO of 16 bytes when FIFO operation is enabled by FCR bit-0. Every time a write operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data location. 2.8.2 Transmitter Operation in non-FIFO Mode The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty. FIGURE 9. TRANSMITTER OPERATION IN NON-FIFO MODE Data Byte 16X or 8X or 4X Clock ( DLD[5:4] ) Transmit Holding Register (THR) THR Interrupt (ISR bit-1) Enabled by IER bit-1 Transmit Shift Register (TSR) M S B L S B TXNOFIFO1 14 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 2.8.3 Transmitter Operation in FIFO Mode The host may fill the transmit FIFO with up to 16 bytes of transmit data. The THR empty flag (LSR bit-5) is set whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the FIFO becomes empty. The transmit empty interrupt is enabled by IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty. FIGURE 10. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE Transmit Data Byte Transmit FIFO THR Interrupt (ISR bit-1) falls below the programmed Trigger Level and then when becomes empty. FIFO is Enabled by FCR bit-0=1 Auto CTS Flow Control (CTS# pin) Flow Control Characters (Xoff1/2 and Xon1/2 Reg.) Auto Software Flow Control 16X or 8X or 4X Clock (DLD[5:4]) Transmit Data Shift Register (TSR) TXFIFO1 2.9 Receiver The receiver section contains an 8-bit Receive Shift Register (RSR) and 16 bytes of FIFO which includes a byte-wide Receive Holding Register (RHR). The RSR uses the 16X/8X/4X clock (DLD[5:4]) for timing. It verifies and validates every bit on the incoming character in the middle of each data bit. On the falling edge of a start or false start bit, an internal receiver counter starts counting at the 16X/8X/4X clock rate. After 8 clocks (or 4 if 8X or 2 if 4X) the start bit period should be at the center of the start bit. At this time the start bit is sampled and if it is still a logic 0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character. The rest of the data bits and stop bits are sampled and validated in this same manner to prevent false framing. If there were any error(s), they are reported in the LSR register bits 2-4. Upon unloading the receive data byte from RHR, the receive FIFO pointer is bumped and the error tags are immediately updated to reflect the status of the data byte in RHR register. RHR can generate a receive data ready interrupt upon receiving a character or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a receive data ready time-out interrupt when data is not received for 4 word lengths as defined by LCR[1:0] plus 12 bits time. This is equivalent to 3.7-4.6 character times. The RHR interrupt is enabled by IER bit-0. See Figure 11 and Figure 12 below. 2.9.1 Receive Holding Register (RHR) - Read-Only The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift Register. It provides the receive data interface to the host processor. The RHR register is part of the receive FIFO of 16 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data byte are immediately updated in the LSR bits 2-4. 15 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 11. RECEIVER OPERATION IN NON-FIFO MODE 16X or 8X or 4X Clock ( DLD[5:4] ) Receive Data Shift Register (RSR) Error Tags in LSR bits 4:2 Receive Data Byte and Errors Receive Data Holding Register (RHR) Data Bit Validation Receive Data Characters RHR Interrupt (ISR bit-2) RXFIFO1 FIGURE 12. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE 16X or 8X or 4X C lock ( D LD [5:4] ) R eceive D ata Shift R egister (R SR ) D ata Bit V alidation 16 bytes by 11-bit w ide FIFO Error Tags (16-sets) D ata falls to 4 R eceive D ata FIFO FIFO Trigger=8 Error Tags in LSR bits 4:2 D ata fills to 14 R eceive D ata Byte and Errors R eceive D ata C haracters E xam ple : - R X FIFO trigger level selected at 8 bytes (See N ote Below ) R TS# re-asserts w hen data falls below the flow control trigger level to restart rem ote transm itter. Enable by EFR bit-6=1, M C R bit-1. R H R Interrupt (IS R bit-2) program m ed for desired FIFO trigger level. FIFO is Enabled by F C R bit-0=1 R TS# de-asserts w hen data fills above the flow control trigger level to suspend rem ote transm itter. Enable by EFR bit-6=1, M C R bit-1. R eceive D ata R X FIFO 1 16 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 2.10 Auto RTS (Hardware) Flow Control Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS# output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control features is enabled to fit specific application requirement (see Figure 13): * Enable auto RTS flow control using EFR bit-6. * The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled). If using the Auto RTS interrupt: * Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1. 2.11 Auto RTS Hysteresis With the Auto RTS function enabled, an interrupt is generated when the receive FIFO reaches the selected RX trigger level. The RTS# pin will not be forced HIGH (RTS off) until the receive FIFO reaches one trigger level above the selected trigger level in the trigger table (Table 9). The RTS# pin will return LOW after the RX FIFO is unloaded to one level below the selected trigger level. Under the above described conditions, the M580 will continue to accept data until the receive FIFO gets full. The Auto RTS function is initiated when the RTS# output pin is asserted LOW (RTS On). TABLE 4: AUTO RTS (HARDWARE) FLOW CONTROL 2.12 RX TRIGGER LEVEL INT PIN ACTIVATION RTS# DE-ASSERTED (HIGH) (CHARACTERS IN RX FIFO) RTS# ASSERTED (LOW) (CHARACTERS IN RX FIFO) 1 1 4 0 4 4 8 1 8 8 14 8 14 14 14 14 Auto CTS Flow Control Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific application requirement (see Figure 13): * Enable auto CTS flow control using EFR bit-7. If needed, the CTS interrupt can be enabled through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the CTS# pin is de-asserted (HIGH): ISR bit-5 will be set to 1, and UART will suspend 17 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 transmission as soon as the stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is re-asserted (LOW), indicating more data may be sent. FIGURE 13. AUTO RTS AND CTS FLOW CONTROL OPERATION Local UART UARTA Remote UART UARTB Receiver FIFO Trigger Reached RXA TXB Auto RTS Trigger Level RTSA# CTSB# Auto CTS Monitor RXB Receiver FIFO Trigger Reached TXA Transmitter CTSA# Auto CTS Monitor RTSA# RTSB# Assert RTS# to Begin Transmission 1 ON Auto RTS Trigger Level 10 OFF ON 7 2 ON CTSB# Transmitter 3 8 OFF 6 Suspend 11 ON TXB Data Starts Restart 9 4 RXA FIFO INTA (RXA FIFO Interrupt) Receive Data RX FIFO Trigger Level 5 RTS High Threshold RTS Low Threshold 12 RX FIFO Trigger Level RTSCTS1 The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO (4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and continues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows (7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its transmit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9), UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB with RTSB# and CTSA# controlling the data flow. 18 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 2.13 Auto Xon/Xoff (Software) Flow Control When software flow control is enabled (See Table 15), the M580 compares one or two sequential receive data characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the programmed values, the M580 will halt transmission (TX) as soon as the current character has completed transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output pin will be activated. Following a suspension due to a match of the Xoff character, the M580 will monitor the receive data stream for a match to the Xon-1,2 character. If a match is found, the M580 will resume operation and clear the flags (ISR bit-4). Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/ Xoff characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are selected, the M580 compares two consecutive receive characters with two software flow control 8-bit values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO. In the event that the receive buffer is overfilling and flow control needs to be executed, the M580 automatically sends an Xoff message (when enabled) via the serial TX output to the remote modem. The M580 sends the Xoff-1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate) after the receive FIFO crosses the selected trigger level. To clear this condition, the M580 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger level below the selected trigger level. Table 5 below explains this. TABLE 5: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL RX TRIGGER LEVEL INT PIN ACTIVATION XOFF CHARACTER(S) SENT (CHARACTERS IN RX FIFO) XON CHARACTER(S) SENT (CHARACTERS IN RX FIFO) 1 1 1* 0 4 4 4* 1 8 8 8* 4 14 14 14* 8 * After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2 characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting. 2.14 Special Character Detect A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal incoming RX data. The M580 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will be transferred to the RX FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff Registers corresponds with the LSB bit for the receive character. 2.15 Normal Multidrop Mode Normal multidrop mode is enabled when MSR[6] = 1 (requires EFR[4] = 1) and EFR[5] = 0 (Special Character Detect disabled). The receiver is set to Force Parity 0 (LCR[5:3] = '111') in order to detect address bytes. With the receiver initially disabled, it ignores all the data bytes (parity bit = 0) until an address byte is received (parity bit = 1). This address byte will cause the UART to set the parity error. The UART will generate an LSR 19 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 interrupt and place the address byte in the RX FIFO. The software then examines the byte and enables the receiver if the address matches its slave address, otherwise, it does not enable the receiver. If the receiver has been enabled, the receiver will receive the subsequent data. If an address byte is received, it will generate an LSR interrupt. The software again examines the byte and if the address matches its slave address, it does not have to do anything. If the address does not match its slave address, then the receiver should be disabled. 2.15.1 Auto Address Detection Auto address detection mode is enabled when MSR[6] = 1 (requires EFR[4] = 1) and EFR bit-5 = 1. The desired slave address will need to be written into the XOFF2 register. The receiver will try to detect an address byte that matches the porgrammed character in the XOFF2 register. If the received byte is a data byte or an address byte that does not match the programmed character in the XOFF2 register, the receiver will discard these data. Upon receiving an address byte that matches the XOFF2 character, the receiver will be automatically enabled if not already enabled, and the address character is pushed into the RX FIFO along with the parity bit (in place of the parity error bit). The receiver also generates an LSR interrupt. The receiver will then receive the subsequent data. If another address byte is received and this address does not match the programmed XOFF2 character, then the receiver will automatically be disabled and the address byte is ignored. If the address byte matches XOFF2, the receiver will put this byte in the RX FIFO along with the parity bit in the parity error bit. 2.16 Infrared Mode The M580 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data Association) version 1.0 and 1.1. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit wide HIGH-pulse for each "0" bit in the transmit data stream with a data rate up to 115.2 Kbps. For the IrDA 1.1 standard, the infrared encoder sends out a 1/4 of a bit time wide HIGH-pulse for each "0" bit in the transmit data stream with a data rate up to 1.152 Mbps. This signal encoding reduces the on-time of the infrared LED, hence reduces the power consumption. See Figure 14 below. The infrared encoder and decoder are enabled by setting MCR register bit-6 to a `1'. With this bit enabled, the infrared encoder and decoder is compatible to the IrDA 1.0 standard. For the infrared encoder and decoder to be compatible to the IrDA 1.1 standard, MSR bit-7 will also need to be set to a '1' when EFR bit-4 is set to '1'. Likewise, the RX input assumes an idle level of logic zero from a reset and power up, see Figure 14. Typically, the wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin. Each time it senses a light pulse, it returns a logic 1 to the data bit stream. 20 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 14. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING TX Data 0 Stop Start Character Data Bits 1 1 0 0 1 0 1 1 0 Transmit IR Pulse (TX Pin) Bit Time 1/2 Bit Time 3/16 or 1/4 Bit Time IrEncoder-1 Receive IR Pulse (RX pin) Bit Time 1/16 Clock Delay 1 0 1 0 0 1 1 0 Data Bits 1 Stop 0 Start RX Data Character IRdecoder-1 2.17 Sleep Mode with Auto Wake-Up and Power-Save feature The M580 supports low voltage system designs, hence, a sleep mode with auto wake-up and power-save feature is included to reduce its power consumption when the chip is not actively used. 2.17.1 Sleep mode All of these conditions must be satisfied for the M580 to enter sleep mode: no interrupts pending (ISR bit-0 = 1) sleep mode is enabled (IER bit-4 = 1) modem inputs are not toggling (MSR bits 0-3 = 0) RX input pin is idling HIGH in normal mode or LOW in infrared mode divisor is non-zero TX and RX FIFOs are empty The M580 stops its crystal oscillator to conserve power in the sleep mode. User can check the XTAL2 pin for no clock output as an indication that the device has entered the sleep mode. The M580 resumes normal operation by any of the following: a receive data start bit transition (HIGH to LOW) a data byte is loaded to the transmitter, THR or FIFO a change of logic state on any of the modem or general purpose serial inputs: CTS#, DSR#, CD#, RI# If the M580 is awakened by any one of the above conditions, it will return to the sleep mode automatically after all interrupting conditions have been serviced and cleared. If the M580 is awakened by the modem inputs, a read to the MSR is required to reset the modem inputs. In any case, the sleep mode will not be entered while 21 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 an interrupt is pending from any channel. The M580 will stay in the sleep mode of operation until it is disabled by setting IER bit-4 to a logic 0. A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the first few receive characters may be lost. Also, make sure the RX pin is idling HIGH or "marking" condition during sleep mode. This may not occur when the external interface transceivers (RS-232, RS-485 or another type) are also put to sleep mode and cannot maintain the "marking" condition. To avoid this, the system design engineer can use a 47k ohm pull-up resistor on each of the RX input. 2.17.2 Power-Save Feature If the address lines, data bus lines, IOW#, IOR#, CS# and modem input lines remain steady when the M580 is in sleep mode, the maximum current will be in the microamp range as specified in the DC Electrical Characteristics on page 43. If the input lines are floating or are toggling while the M580 is in sleep mode, the current can be up to 100 times more. If not using the Power-Save feature, an external buffer would be required to keep the address and data bus lines from toggling or floating to achieve the low current. But if the PowerSave feature is enabled (PwrSave pin connected to VCC), this will eliminate the need for an external buffer by internally isolating the address, data and control signals (see Figure 1 on page 1) from other bus activities that could cause wasteful power drain. The M580 enters Power-Save mode when this pin is connected to VCC and the M580 is in sleep mode (see Sleep Mode section above). Since Power-Save mode isolates the address, data and control signals, the device will wake-up only by: a receive data start bit transition (HIGH to LOW) at the RX input or a change of logic state on the modem or general purpose serial input CTS#, DSR#, CD#, RI# The M580 will return to the Power-Save mode automatically after a read to the MSR (to reset the modem input CTS#) and all interrupting conditions have been serviced and cleared. The M580 will stay in the Power-Save mode of operation until it is disabled by setting IER bit-4 to a logic 0 and/or the Power-Save pin is connected to GND. 2.17.3 Wake-up Interrupt The M580 has the wake up interrupt. By setting the FCR bit-3, wake up interrupt is enabled or disabled. The default status of wake up interrupt is disabled. Please See "Section 4.5, FIFO Control Register (FCR) Write-Only" on page 30. 22 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 2.18 Internal Loopback The M580 UART provides an internal loopback capability for system diagnostic purposes. The internal loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally. Figure 15 shows how the modem port signals are re-configured. Transmit data from the transmit shift register output is internally routed to the receive shift register input allowing the system to receive the same data that it was sending. The TX pin is held HIGH or mark condition while RTS# and DTR# are de-asserted, and CTS#, DSR# CD# and RI# inputs are ignored. Caution: the RX input must be held HIGH during loopback test else upon exiting the loopback test the UART may detect and report a false "break" signal. FIGURE 15. INTERNAL LOOPBACK VCC TX T ra n s m it S h ift R e g is te r (T H R /F IF O ) R e c e iv e S h ift R e g is te r (R H R /F IF O ) RX VCC RTS# RTS# Modem / General Purpose Control Logic Internal Data Bus Lines and Control Signals M C R b it-4 = 1 CTS# CTS# VCC DTR# DTR# DSR# DSR# OP1# R I# R I# OP2# CD# CD# 23 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 3.0 UART INTERNAL REGISTERS The complete register set for the M580 is shown in Table 6 and Table 7. TABLE 6: UART INTERNAL REGISTERS A2 A1 A0 ADDRESSES REGISTER READ/WRITE COMMENTS 16C550 COMPATIBLE REGISTERS 0 0 0 DREV - Device Revision Read-only 0 0 1 DVID - Device Identification Register Read-only 0 0 0 DLL - Divisor LSB Register Read/Write 0 0 1 DLM - Divisor MSB Register Read/Write 0 1 0 DLD - Divisor Fractional Register Read/Write 0 0 0 RHR - Receive Holding Register THR - Transmit Holding Register Read-only Write-only LCR[7] = 1, LCR 0xBF, DLL = 0x00, DLM = 0x00 LCR[7] = 1, LCR 0xBF See DLD[7:6] LCR[7] = 1, LCR 0xBF, EFR[4] = 1 LCR[7] = 0 0 0 1 IER - Interrupt Enable Register Read/Write 0 1 0 ISR - Interrupt Status Register FCR - FIFO Control Register Read-only Write-only 0 1 1 LCR - Line Control Register Read/Write 1 0 0 MCR - Modem Control Register Read/Write 1 0 1 LSR - Line Status Register Read-only 1 1 0 MSR - Modem Status Register Read-only 1 1 0 MSR - Modem Status Register Write-only LCR 0xBF EFR[4] = 1 1 1 1 SPR - Scratch Pad Register Read/Write LCR 0xBF, FCTR[6] = 0 1 1 1 EMSR - Enhanced Mode Select Register Write-only 1 1 1 FC - RX/TX FIFO Level Counter Register Read-only LCR[7] = 0 if EFR[4] = 1 or LCR 0xBF if EFR[4] = 0 LCR 0xBF LCR 0xBF, FCTR[6] = 1 ENHANCED REGISTERS 0 0 0 FC - RX/TX FIFO Level Counter Register Read-only 0 0 1 FCTR - Feature Control Register Read/Write 0 1 0 EFR - Enhanced Function Reg Read/Write 1 0 0 Xon-1 - Xon Character 1 Read/Write 1 0 1 Xon-2 - Xon Character 2 Read/Write 1 1 0 Xoff-1 - Xoff Character 1 Read/Write 1 1 1 Xoff-2 - Xoff Character 2 Read/Write 24 LCR = 0xBF XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 TABLE 7: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ADDRESS A2-A0 REG NAME READ/ WRITE BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 COMMENT 16C550 Compatible Registers 000 RHR RD Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 000 THR WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 001 IER RD/WR 0/ 0/ 0/ 0/ CTS# Int. Enable RTS# Int. Enable Xoff Int. Enable Sleep Mode Enable 0/ 0/ INT Source Bit-3 FIFOs FIFOs Enabled Enabled Modem RX Line TX RX LCR[7] = 0 Stat. Int. Stat. Empty Data Enable Int. Int Int. Enable Enable Enable 010 ISR RD INT INT INT Source Source Source LCR[7] = 0 RTS Xoff Bit-2 Bit-1 Bit-0 if EFR[4]=1 CTS Interrupt or Interrupt LCR0xBF RX FIFO RX FIFO TX FIFO TX FIFO Wake up TX RX FIFOs if EFR[4]=0 Trigger Trigger Trigger Trigger Int Enable FIFO FIFO Enable Reset Reset 010 FCR WR 011 LCR RD/WR Divisor Enable Set TX Break Set Parity Even Parity Parity Enable Stop Bits Word Word Length Length Bit-1 Bit-0 100 MCR RD/WR 0/ 0/ 0/ Internal Lopback Enable INT Output Enable (OP2#) OP1# RTS# DTR# Output Output Control Control RX Break RX Framing Error RX Parity Error BRG Prescaler 101 110 LSR MSR RD RX FIFO Global Error IR Mode XonAny ENable THR & TSR Empty THR Empty RX Overrun Error RX Data Ready LCR0xBF RD CD# Input RI# Input DSR# Input CTS# Input Delta CD# Delta RI# Delta DSR# Delta CTS# WR Fast IR Enable 9-bit mode Disable RX Disable TX 0 0 0 0 Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 0 0 Invert RTS in RS485 mode Send TX immediate Bit-5 Bit-4 Bit-3 Bit-2 111 SPR RD/WR 111 EMSR WR 111 FC RD Xoff LSR interrupt interrupt mode mode select select Bit-7 Bit-6 25 LCR0xBF FCTR[6]=0 FIFO FIFO count count control control LCR0xBF bit-1 bit-0 FCTR[6]=1 Bit-1 Bit-0 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 TABLE 7: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ADDRESS A2-A0 REG NAME READ/ WRITE BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 COMMENT LCR[7] = 1 LCR0xBF DLL= 0x00 DLM= 0x00 Baud Rate Generator Divisor 000 DREV RD Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 001 DVID RD 0 0 0 0 0 0 0 1 000 DLL RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 001 DLM RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 010 DLD RD/WR BRG select Bit-3 Bit-2 Bit-1 Bit-0 Enable 4X Mode 8X Mode Independent BRG LCR[7] = 1 LCR0xBF DLD[7:6] LCR[7] = 1 LCR0xBF EFR[4] = 1 Enhanced Registers 000 001 010 FC RD FCTR RD/WR EFR RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 RX/TX select Swap SCR 0 0 RS485 interrupt mode invert RX IR 0 0 Auto CTS# Enable Auto RTS# Enable Special Char Select Enable IER [7:4], ISR [5:4], FCR[5:3], MCR[7:5], DLD Software Flow Cntl Bit-3 Software Flow Cntl Bit-2 Software Flow Cntl Bit-1 Software Flow Cntl Bit-0 100 XON1 RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 101 XON2 RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 110 XOFF1 RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 111 XOFF2 RD/WR Bit-7 Bit-6 Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 LCR=0XBF 4.0 INTERNAL REGISTER DESCRIPTIONS 4.1 Receive Holding Register (RHR) - Read- Only SEE"RECEIVER" ON PAGE 15. 4.2 Transmit Holding Register (THR) - Write-Only SEE"TRANSMITTER" ON PAGE 14. 4.3 Interrupt Enable Register (IER) - Read/Write The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR). 26 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 4.3.1 IER versus Receive FIFO Interrupt Mode Operation When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts (see ISR bits 2 and 3) status will reflect the following: A. The receive data available interrupts are issued to the host when the FIFO has reached the selected trigger level. It will be cleared when the FIFO drops below the selected trigger level. B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register status bit and the interrupt will be cleared when the FIFO drops below the trigger level. C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to the receive FIFO. It is reset when the FIFO is empty. 4.3.2 IER versus Receive/Transmit FIFO Polled Mode Operation When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16M580 in the FIFO polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can be used in the polled mode by selecting respective transmit or receive control bit(s). A. LSR BIT-0 indicates there is data in RHR or RX FIFO. B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid. C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any. D. LSR BIT-5 indicates THR is empty. E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty. F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO. IER[0]: RHR Interrupt Enable The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when the receive FIFO has reached the selected trigger level in the FIFO mode. Logic 0 = Disable the receive data ready interrupt (default). Logic 1 = Enable the receiver data ready interrupt. IER[1]: THR Interrupt Enable This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the nonFIFO mode or when data in the FIFO falls below the selected trigger level in the FIFO mode. If the THR is empty when this bit is enabled, an interrupt will be generated. Logic 0 = Disable Transmit Ready interrupt (default). Logic 1 = Enable Transmit Ready interrupt. IER[2]: Receive Line Status Interrupt Enable If any of the LSR register bits 1, 2, 3 or 4 is a logic 1, it will generate an interrupt to inform the host controller about the error status of the current data byte in FIFO. LSR bit-1 generates an interrupt immediately when an overrun occurs. LSR bits 2-4 generate an interrupt when the character in the RHR has an error. However, when EMSR bit-6 changes to 1 (default is 0), LSR bit 2-4 generate an interrupt when the character is received in the RX FIFO. See "Section 4.12, Enhanced Mode Select Register (EMSR) - Write-only" on page 37. * Logic 0 = Disable the receiver line status interrupt (default). * Logic 1 = Enable the receiver line status interrupt. IER[3]: Modem Status Interrupt Enable * Logic 0 = Disable the modem status register interrupt (default). * Logic 1 = Enable the modem status register interrupt. 27 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 IER[4]: Sleep Mode Enable (requires EFR[4] = 1) * Logic 0 = Disable Sleep Mode (default). * Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details. IER[5]: Xoff Interrupt Enable (requires EFR[4]=1) * Logic 0 = Disable the software flow control, receive Xoff interrupt. (default) * Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for details. IER[6]: RTS# Output Interrupt Enable (requires EFR[4]=1) * Logic 0 = Disable the RTS# interrupt (default). * Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition from LOW to HIGH (if enabled by EFR bit-6). IER[7]: CTS# Input Interrupt Enable (requires EFR[4]=1) * Logic 0 = Disable the CTS# interrupt (default). * Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from LOW to HIGH (if enabled by EFR bit-7). 4.4 Interrupt Status Register (ISR) - Read-Only The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt Source Table, Table 8, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources associated with each of these interrupt levels. 4.4.1 Interrupt Generation: * LSR is by any of the LSR bits 1, 2, 3 and 4. * RXRDY is by RX trigger level. * RXRDY Time-out is by a 4-char plus 12 bits delay timer. * TXRDY is by TX trigger level or TX FIFO empty. * MSR is by any of the MSR bits 0, 1, 2 and 3. * Receive Xon/Xoff/Special character is by detection of a Xon, Xoff or Special character. * CTS# is when the remote transmitter toggles the input pin (from LOW to HIGH) during auto CTS flow control. * RTS# is when its receiver toggles the output pin (from LOW to HIGH) during auto RTS flow control. * Wakeup interrupt is generated when the M580 wakes up from the sleep mode. 4.4.2 Interrupt Clearing: * LSR interrupt is cleared by a read to the LSR register. * RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level. * RXRDY Time-out interrupt is cleared by reading RHR. * TXRDY interrupt is cleared by a read to the ISR register or writing to THR. * MSR interrupt is cleared by a read to the MSR register. * Xon or Xoff interrupt is cleared by a read to the ISR register. See EMSR[7]. 28 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 * Special character interrupt is cleared by a read to ISR register or after next character is received. See EMSR[7]. * RTS# and CTS# flow control interrupts are cleared by a read to the MSR register. * Wakeup interrupt is cleared by a read to ISR register. ] TABLE 8: INTERRUPT SOURCE AND PRIORITY LEVEL PRIORITY ISR REGISTER STATUS BITS SOURCE OF INTERRUPT LEVEL BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0 1 0 0 0 1 1 0 LSR (Receiver Line Status Register) 2 0 0 1 1 0 0 RXRDY (Receive Data Time-out) 3 0 0 0 1 0 0 RXRDY (Received Data Ready) 4 0 0 0 0 1 0 TXRDY (Transmit Ready) 5 0 0 0 0 0 0 MSR (Modem Status Register) 6 0 1 0 0 0 0 RXRDY (Received Xon, Xoff or Special character) 7 1 0 0 0 0 0 CTS#, RTS# change of state - 0 0 0 0 0 1 None (default) or Wakeup interrupt ISR[0]: Interrupt Status * Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt service routine. * Logic 1 = No interrupt pending (default condition). ISR[3:1]: Interrupt Status These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source Table 8). ISR[4]: Interrupt Status (requires EFR bit-4 = 1) This bit is enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that the receiver detected a data match of the Xoff, Xon or special character(s). ISR[5]: Interrupt Status (requires EFR bit-4 = 1) ISR bit-5 indicates that CTS# or RTS# has changed state from LOW to HIGH. ISR[7:6]: FIFO Enable Status These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are enabled. 29 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 4.5 REV. 1.0.0 FIFO Control Register (FCR) - Write-Only This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and enable the wake up interrupt. They are defined as follows: FCR[0]: TX and RX FIFO Enable * Logic 0 = Disable the transmit and receive FIFO (default). * Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are written or they will not be programmed. FCR[1]: RX FIFO Reset This bit is only active when FCR bit-0 is a `1'. * Logic 0 = No receive FIFO reset (default) * Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not cleared or altered). This bit will return to a logic 0 after resetting the FIFO. FCR[2]: TX FIFO Reset This bit is only active when FCR bit-0 is a `1'. * Logic 0 = No transmit FIFO reset (default). * Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not cleared or altered). This bit will return to a logic 0 after resetting the FIFO. FCR[3]: Enable wake up interrupt (requires EFR bit-4 = 1) * Logic 0 = Disable the wake up interrupt (default). * Logic 1 = Enable the wake up interrupt. Please refer to "Section 2.17.3, Wake-up Interrupt" on page 22. FCR[5:4]: Transmit FIFO Trigger Select (requires EFR bit-4 = 1) These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the number of characters in the FIFO falls below the selected trigger level, or when it gets empty in case that the FIFO did not get filled over the trigger level on last re-load. Table 9 below shows the selections. Note that the receiver and the transmitter cannot use different trigger tables. Whichever selection is made last applies to both the RX and TX side. FCR[7:6]: Receive FIFO Trigger Select These 2 bits are used to set the trigger level for the receive FIFO. The UART will issue a receive interrupt when the number of the characters in the FIFO crosses the trigger level. Table 9 shows the complete selections. Note that the receiver and the transmitter cannot use different trigger tables. Whichever selection is made last applies to both the RX and TX side. 30 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 TABLE 9: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION FCR BIT-7 0 0 1 1 4.6 FCR BIT-6 FCR BIT-5 FCR BIT-4 0 0 1 1 0 1 0 1 RECEIVE TRIGGER LEVEL TRANSMIT TRIGGER LEVEL 1(default) 4 8 14 0 1 0 1 COMPATIBILITY 16L580 1(default) 4 8 14 Line Control Register (LCR) - Read/Write The Line Control Register is used to specify the asynchronous data communication format. The word or character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this register. LCR[1:0]: TX and RX Word Length Select These two bits specify the word length to be transmitted or received. BIT-1 BIT-0 WORD LENGTH 0 0 5 (default) 0 1 6 1 0 7 1 1 8 LCR[2]: TX and RX Stop-bit Length Select The length of stop bit is specified by this bit in conjunction with the programmed word length. LENGTH STOP BIT LENGTH (BIT TIME(S)) 0 5,6,7,8 1 (default) 1 5 1-1/2 1 6,7,8 2 BIT-2 WORD LCR[3]: TX and RX Parity Select Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data integrity check. See Table 10 for parity selection summary below. * Logic 0 = No parity. * Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the data character received. 31 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 LCR[4]: TX and RX Parity Select If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR BIT-4 selects the even or odd parity format. * Logic 0 = ODD Parity is generated by forcing an odd number of logic 1's in the transmitted character. The receiver must be programmed to check the same format (default). * Logic 1 = EVEN Parity is generated by forcing an even number of logic 1's in the transmitted character. The receiver must be programmed to check the same format. LCR[5]: TX and RX Parity Select If the parity bit is enabled, LCR BIT-5 selects the forced parity format. * LCR BIT-5 = logic 0, parity is not forced (default). * LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive data. * LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive data. TABLE 10: PARITY SELECTION LCR BIT-5 LCR BIT-4 LCR BIT-3 PARITY SELECTION X X 0 No parity 0 0 1 Odd parity 0 1 1 Even parity 1 0 1 Force parity to mark, HIGH 1 1 1 Forced parity to space, LOW LCR[6]: Transmit Break Enable When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a "space', logic 0, state). This condition remains, until disabled by setting LCR bit-6 to a logic 0. * Logic 0 = No TX break condition. (default) * Logic 1 = Forces the transmitter output (TX) to a "space", logic 0, for alerting the remote receiver of a line break condition. LCR[7]: Baud Rate Divisors Enable Baud rate generator divisor (DLL/DLM/DLD) enable. * Logic 0 = Data registers are selected. (default) * Logic 1 = Divisor latch registers are selected. 4.7 Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs. MCR[0]: DTR# Output The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a general purpose output. * Logic 0 = Force DTR# output HIGH (default). * Logic 1 = Force DTR# output LOW. 32 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 MCR[1]: RTS# Output The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by EFR bit-6. If the modem interface is not used, this output may be used as a general purpose output. * Logic 0 = Force RTS# output HIGH (default). * Logic 1 = Force RTS# output LOW. It is required to start Auto RTS Flow Control. MCR[2]: Reserved OP1# is not available as an output pin on the M580. But it is available for use during Internal Loopback Mode. In the Loopback Mode, this bit is used to write the state of the modem RI# interface signal. MCR[3]: INT Output Enable Enable or disable INT outputs to become active or in three-state. This bit is also used to control the OP2# signal during internal loopback mode. * Logic 0 = INT output disabled (three state) in the 16 mode (default). During internal loopback mode, OP2# is HIGH. * Logic 1 = INT output enabled (active) in the 16 mode. During internal loopback mode, OP2# is LOW. TABLE 11: INT OUTPUT MODES MCR BIT-3 INT OUTPUT IN 16 MODE 0 Three-State 1 Active MCR[4]: Internal Loopback Enable * Logic 0 = Disable loopback mode (default). * Logic 1 = Enable local loopback mode, see loopback section and Figure 15. MCR[5]: Xon-Any Enable (requires EFR bit-4 = 1) * Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default). * Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation. The RX character will be loaded into the RX FIFO , unless the RX character is an Xon or Xoff character and the M580 is programmed to use the Xon/Xoff flow control. MCR[6]: Infrared Encoder/Decoder Enable (requires EFR bit-4 = 1) * Logic 0 = Enable the standard modem receive and transmit input/output interface. (Default) * Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface requirement. The RX FIFO may need to be flushed upon enable. While in this mode, the infrared TX output will be LOW during idle data conditions. MCR[7]: Clock Prescaler Select (requires EFR bit-4 = 1) * Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable Baud Rate Generator without further modification, i.e., divide by one (default). * Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth. 33 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 4.8 REV. 1.0.0 Line Status Register (LSR) - Read Only This register provides the status of data transfers between the UART and the host. If IER bit-2 is enabled, LSR bit 1 will generate an interrupt immediately and LSR bits 2-4 will generate an interrupt when a character with an error is in the RHR. LSR[0]: Receive Data Ready Indicator * Logic 0 = No data in receive holding register or FIFO (default). * Logic 1 = Data has been received and is saved in the receive holding register or FIFO. LSR[1]: Receiver Overrun Flag * Logic 0 = No overrun error (default). * Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into the FIFO, therefore the data in the FIFO is not corrupted by the error. LSR[2]: Receive Data Parity Error Tag * Logic 0 = No parity error (default). * Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect. This error is associated with the character available for reading in RHR. LSR[3]: Receive Data Framing Error Tag * Logic 0 = No framing error (default). * Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with the character available for reading in RHR. LSR[4]: Receive Break Tag * Logic 0 = No break condition (default). * Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX input returns to the idle condition, "mark" or HIGH. LSR[5]: Transmit Holding Register Empty Flag This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0 concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte. LSR[6]: THR and TSR Empty Flag This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and transmit shift register are both empty. LSR[7]: Receive FIFO Data Error Flag * Logic 0 = No FIFO error (default). * Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the RX FIFO. 34 XR16M580 REV. 1.0.0 4.9 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO Modem Status Register (MSR) - Read Only This register provides the current state of the modem interface input signals. Lower four bits of this register are used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem changes state. These bits may be used for general purpose inputs when they are not used with modem signals. Reading the higher four bits shows the status of the modem signals. MSR[0]: Delta CTS# Input Flag * Logic 0 = No change on CTS# input (default). * Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[1]: Delta DSR# Input Flag * Logic 0 = No change on DSR# input (default). * Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[2]: Delta RI# Input Flag * Logic 0 = No change on RI# input (default). * Logic 1 = The RI# input has changed from LOW to HIGH, ending of the ringing signal. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[3]: Delta CD# Input Flag * Logic 0 = No change on CD# input (default). * Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem status interrupt will be generated if MSR interrupt is enabled (IER bit-3). MSR[4]: CTS Input Status CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto CTS (EFR bit-7). Auto CTS Flow Control allows starting and stopping of local data transmissions based on the modem CTS# signal. A HIGH on the CTS# pin will stop UART transmitter as soon as the current character has finished transmission, and a LOW will resume data transmission. Normally MSR bit-4 bit is the complement of the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR register. The CTS# input may be used as a general purpose input when the modem interface is not used. MSR[5]: DSR Input Status Normally this bit is the complement of the DSR# input. In the loopback mode, this bit is equivalent to the DTR# bit in the MCR register. The DSR# input may be used as a general purpose input when the modem interface is not used. MSR[6]: RI Input Status Normally this bit is the complement of the RI# input. In the loopback mode this bit is equivalent to bit-2 in the MCR register. The RI# input may be used as a general purpose input when the modem interface is not used. MSR[7]: CD Input Status Normally this bit is the complement of the CD# input. In the loopback mode this bit is equivalent to bit-3 in the MCR register. The CD# input may be used as a general purpose input when the modem interface is not used. 35 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 4.10 REV. 1.0.0 Modem Status Register (MSR) - Write Only This register provides the advanced features of XR16M580. Lower four bits of this register are reserved. Writing to the higher four bits enables additional functions. MSR[3:0]: Reserved MSR[4]: Enable/Disable Transmitter (Requires EFR[4] = 1) * Logic 0 = Enable Transmitter (default). * Logic 1 = Disable Transmitter. MSR[5]: Enable/Disable Receiver (Requires EFR[4] = 1) * Logic 0 = Enable Receiver (default). * Logic 1 = Disable Receiver. MSR[6]: Enable/Disable 9-bit mode (Requires EFR[4] = 1) For the 9-bit mode information, See "Section 2.15, Normal Multidrop Mode" on page 19. * Logic 0 = Normal 8-bit mode (default). * Logic 1 = Enable 9-bit or Multidrop mode. MSR[7]: Enable/Disable fast IR mode (Requires EFR[4] = 1) The M580 supports the new fast IR transmission with data rate up to 1.152 Mbps. * Logic 0 = IrDA version 1.0, 3/16 pulse ratio, data rate up to 115.2 Kbps (default). * Logic 1 = IrDA version 1.1, 1/4 pulse ratio, data rate up to 1.152 Mbps. For more IR mode information, please See "Section 2.16, Infrared Mode" on page 20. 4.11 Scratch Pad Register (SPR) - Read/Write This is a 8-bit general purpose register for the user to store temporary data. The content of this register is preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle. 36 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 4.12 Enhanced Mode Select Register (EMSR) - Write-only This register replaces SPR (during a Write) and is accessible only when FCTR[6] = 1. EMSR[1:0]: Receive/Transmit FIFO Level Count When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is operating in. TABLE 12: SCRATCHPAD SWAP SELECTION FCTR[6] EMSR[1] EMSR[0] Scratchpad is 0 X X Scratchpad 1 X 0 RX FIFO Level Counter Mode 1 0 1 TX FIFO Level Counter Mode 1 1 1 Alternate RX/TX FIFO Counter Mode During Alternate RX/TX FIFO Level Counter Mode, the first value read after EMSR bits 1-0 have been asserted will always be the RX FIFO Level Counter. The second value read will correspond with the TX FIFO Level Counter. The next value will be the RX FIFO Level Counter again, then the TX FIFO Level Counter and so on and so forth. EMSR[2]: Send TX Immediately * Logic 0 = Do not send TX immediately (default). * Logic 1 = Send TX immediately. When FIFO is enabled and this bit is set, the next data will be written to the TX shift register. Thus, the data will be sent out immediately instead of queuing in the FIFO. Every time, only 1 byte will be send out. Once this byte has been sent out, the EMSR[2] will go back to 0 automatically. If more than 1 byte will be sent out, EMSR[2] needs to be set to 1 for each byte. EMSR[3]: Invert RTS in RS485 mode * Logic 0 = RTS# output is a logic 0 during TX and a logic 1 during RX (default). * Logic 1 = RTS# output is a logic 1 during TX and a logic 0 during RX. EMSR[5:4]: Reserved EMSR[6]: LSR Interrupt Mode * Logic 0 = LSR Interrupt Delayed (default). LSR bits 2, 3, and 4 will generate an interrupt when the character with the error is in the RHR. * Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is received into the FIFO. EMSR[7]: Xoff/Special character Interrupt Mode Select This bit selects how the Xoff and Special character interrupt is cleared. The XON interrupt can only be cleared by reading the ISR register. * Logic 0 = Xoff interrupt is cleared by either reading ISR register or when an XON character is received. Special character interrupt is cleared by either reading ISR register or when next character is received. (default). * Logic 1 = Xoff/Special character interrupt can only be cleared by reading the ISR register. 37 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 4.13 REV. 1.0.0 Baud Rate Generator Registers (DLL, DLM and DLD) - Read/Write These registers make-up the value of the baud rate divisor. The M580 has different DLL, DLM and DLD for transmitter and receiver. It provides more convenience for the transmitter and receiver to transmit data with different rate. The M580 uses DLD[7:6] to select TX or RX. Then it provides DLD[5:0] to select the sampling frequency and fractional baud rate divisor. The concatenation of the contents of DLM and DLL gives the 16-bit divisor value. The value is added to DLD[3:0]/16 to achieve the fractional baud rate divisor. DLD must be enabled via EFR bit-4 before it can be accessed. See Table 13 below and See "Section 2.7, Programmable Baud Rate Generator with Fractional Divisor" on page 12. DLD[5:4]: Sampling Rate Select These bits select the data sampling rate. By default, the data sampling rate is 16X. The maximum data rate will double if the 8X mode is selected and will quadruple if the 4X mode is selected. See Table 13 below. TABLE 13: SAMPLING RATE SELECT DLD[5] DLD[4] SAMPLING RATE 0 0 16X 0 1 8X 1 X 4X DLD[6]: Independent BRG enable * Logic 0 = The Transmitter and Receiver uses the same Baud Rate Generator. (default). * Logic 1 = The Transmitter and Receiver uses different Baud Rate Generators. Use DLD[7] for selecting which baud rate generator to configure. DLD[7]: BRG select When DLD[6] = 1, this bit selects whether the values written to DLL, DLM and DLD[5:0] will be for the Transmit Baud Rate Generator or the Receive Baud Rate Generator. When DLD[6] = 0 (same Baud Rate Generator used for both TX and RX), this bit must be a logic 0 to properly write to the appropriate DLL, DLM and DLD[5:0]. . TABLE 14: BRG SELECT DLD[7] DLD[6] BRG 0 0 Transmitter and Receiver uses same BRG. Writing to DLL, DLM and DLD[5:0] configures the BRG for both the TX and RX. 0 1 Transmitter and Receiver uses different BRGs. Writing to DLL, DLM and DLD[5:0] configures the BRG for TX. 1 1 Transmitter and Receiver uses different BRGs. Writing to DLL, DLM and DLD[5:0] configures the BRG for RX. 1 0 Transmitter and Receiver uses same BRG. Writing to DLL, DLM and DLD[5:0] has no effect on BRG used by the TX and RX. 38 XR16M580 REV. 1.0.0 4.14 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO RX/TX FIFO Level Count Register (FC) - Read-Only This register replaces SPR (during a read) and is accessible when FCTR[6] = 1. This register is also accessible when LCR = 0xBF. It is suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1. See Table 12. FC[7:0]: RX/TX FIFO Level Count Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter FIFO (FCTR[7] = 1) can be read via this register. Reading this register is not recommended when transmitting or receiving data. 4.15 Feature Control Register (FCTR) - Read/Write FCTR[1:0]: Reserved FCTR[2]: IrDa RX Inversion * Logic 0 = Select RX input as encoded IrDa data (Idle state will be LOW). * Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be HIGH). FCTR[3]: Auto RS-485 Direction Control * Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register becomes empty and transmit shift register is shifting data out. * Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its output logic state from LOW to HIGH one bit time after the last stop bit of the last character is shifted out. Also, the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The RTS# output pin will automatically return to a LOW when a data byte is loaded into the TX FIFO. However, RTS# behavior can be inverted by setting EMSR[3] = 1. FCTR[5:4]: Reserved FCTR[6]: Scratchpad Swap * Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode. * Logic 1 = FIFO Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced Mode Select Register is selected when it is written into. FCTR[7]: Programmable Trigger Register Select * Logic 0 = Register FC selected for RX. * Logic 1 = Register FC selected for TX. 39 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO 4.16 REV. 1.0.0 Enhanced Feature Register (EFR) - Read/Write Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive character software flow control selection (see Table 15). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before programming a new setting. EFR[3:0]: Software Flow Control Select Single character and dual sequential characters software flow control is supported. Combinations of software flow control can be selected by programming these bits. TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS EFR BIT-3 CONT-3 EFR BIT-2 CONT-2 EFR BIT-1 CONT-1 EFR BIT-0 CONT-0 0 0 0 0 No TX and RX flow control (default and reset) 0 0 X X No transmit flow control 1 0 X X Transmit Xon1, Xoff1 0 1 X X Transmit Xon2, Xoff2 1 1 X X Transmit Xon1 and Xon2, Xoff1 and Xoff2 X X 0 0 No receive flow control X X 1 0 Receiver compares Xon1, Xoff1 X X 0 1 Receiver compares Xon2, Xoff2 1 0 1 1 Transmit Xon1, Xoff1 Receiver compares Xon1 or Xon2, Xoff1 or Xoff2 0 1 1 1 Transmit Xon2, Xoff2 Receiver compares Xon1 or Xon2, Xoff1 or Xoff2 1 1 1 1 Transmit Xon1 and Xon2, Xoff1 and Xoff2, Receiver compares Xon1 and Xon2, Xoff1 and Xoff2 0 0 1 1 No transmit flow control, Receiver compares Xon1 and Xon2, Xoff1 and Xoff2 TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL EFR[4]: Enhanced Function Bits Enable Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 3-5, MCR bits 5-7, and DLD to be modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the new values. This feature prevents legacy software from altering or overwriting the enhanced functions once set. Normally, it is recommended to leave it enabled, logic 1. * Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 3-5, MCR bits 57, and DLD are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 3-5, and MCR bits 5-7, and DLD are set to a logic 0 to be compatible with ST16C550 mode (default). * Logic 1 = Enables the EFR[3:0] register bits to be modified by the user. 40 XR16M580 REV. 1.0.0 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO EFR[5]: Special Character Detect Enable * Logic 0 = Special Character Detect Disabled (default). * Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= `10') then flow control and special character work normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= `01') then flow control works normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character interrupt, if enabled via IER bit-5. EFR[6]: Auto RTS Flow Control Enable RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is selected, an interrupt will be generated when the receive FIFO is filled to the selected trigger level and RTS deasserts HIGH at the next upper trigger level/hysteresis level. RTS# will return LOW when FIFO data falls below the next lower trigger level/hysteresis level. The RTS# output must be asserted (LOW) before the auto RTS can take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled. * Logic 0 = Automatic RTS flow control is disabled (default). * Logic 1 = Enable Automatic RTS flow control. EFR[7]: Auto CTS Flow Control Enable Automatic CTS Flow Control. * Logic 0 = Automatic CTS flow control is disabled (default). * Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic 1. Data transmission resumes when CTS# returns to a logic 0. 4.17 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2. For more details, see Table 5. The xoff2 is also used as auto address detect register when the auto 9-bit mode enabled. See "Section 2.15.1, Auto Address Detection" on page 20. 41 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO TABLE 16: UART RESET CONDITIONS REGISTERS RESET STATE DLM, DLL DLM = 0x00 and DLL = 0x01. Only resets to these val(Both TX and RX) ues during a power up. They do not reset when the Reset Pin is asserted. DLD Bits 7-0 = 0x00 RHR Bits 7-0 = 0xXX THR Bits 7-0 = 0xXX IER Bits 7-0 = 0x00 FCR Bits 7-0 = 0x00 ISR Bits 7-0 = 0x01 LCR Bits 7-0 = 0x00 MCR Bits 7-0 = 0x00 LSR Bits 7-0 = 0x60 MSR Bits 7-0 =0xX0 (Read-only) Bits 7-4 = 0000 (Write-only) SPR Bits 7-0 = 0xFF EMSR Bits 7-0 = 0x00 FC Bits 7-0 = 0x00 FCTR Bits 7-0 = 0x00 EFR Bits 7-0 = 0x00 XON1 Bits 7-0 = 0x00 XON2 Bits 7-0 = 0x00 XOFF1 Bits 7-0 = 0x00 XOFF2 Bits 7-0 = 0x00 I/O SIGNALS RESET STATE TX HIGH RTS# HIGH DTR# HIGH INT (16 Mode) Three-State Condition IRQ# (68 Mode) HIGH 42 REV. 1.0.0 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 ABSOLUTE MAXIMUM RATINGS Power Supply Range 3.6 Volts Voltage at Any Pin GND-0.3 V to 3.6 V Operating Temperature -40o to +85oC Storage Temperature -65o to +150oC Package Dissipation 500 mW TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%) Thermal Resistance (32-QFN) theta-ja = 28oC/W, theta-jc = 10.5oC/W Thermal Resistance (48-TQFP) theta-ja = 49oC/W, theta-jc = 10oC/W Thermal Resistance (25-BGA) theta-ja = 166oC/W, theta-jc = 98.2oC/W ELECTRICAL CHARACTERISTICS DC ELECTRICAL CHARACTERISTICS UNLESS OTHERWISE NOTED: TA = -40O TO +85OC, VCC IS 1.62 TO 3.63V SYMBOL PARAMETER LIMITS 1.8V MIN MAX LIMITS 2.5V MIN MAX LIMITS 3.3V MIN MAX UNITS CONDITIONS VILCK Clock Input Low Level -0.3 0.3 -0.3 0.4 -0.3 0.6 V VIHCK Clock Input High Level 1.4 VCC 2.0 VCC 2.4 VCC V VIL Input Low Voltage -0.3 0.2 -0.3 0.5 -0.3 0.7 V VIH Input High Voltage 1.4 VCC 1.8 VCC 2.0 VCC V VOL Output Low Voltage 0.4 V V V IOL = 6 mA V V IOH = -4 mA 0.4 0.4 VOH Output High Voltage 2.0 1.8 1.4 IOL = 4 mA IOL = 1.5 mA IOH = -2 mA IOH = -200 uA IIL Input Low Leakage Current 15 15 15 uA IIH Input High Leakage Current 15 15 15 uA CIN Input Pin Capacitance 5 5 5 pF ICC Power Supply Current 1.5 2 2.5 mA Ext Clk = 5MHz 3 6 15 uA See Test 1 ISLEEP/ IPWRSV Sleep / Power Save Current (16 and 68 modes) Test 1: The following inputs remain steady at VCC or GND state to minimize Sleep current: A0-A2, D0-D7, IOR#, IOW#, CS#. Also, RX input must idle at HIGH while asleep. For Power-Save, the UART internally isolates all of these inputs (except the modem inputs, 16/68# and Reset pins) therefore eliminating any unnecessary external buffers to keep the inputs steady. SEE"POWER-SAVE FEATURE" ON 43 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 PAGE 22. To achieve minimum power drain, the voltage at any of the inputs of the M580M580 should NOT be lower than its VCC supply. AC ELECTRICAL CHARACTERISTICS TA = -40O TO +85OC, VCC IS 1.62 TO 3.6V, 70 PF LOAD WHERE APPLICABLE LIMITS 1.8V 10% MIN MAX LIMITS 2.5V 10% MIN MAX LIMITS 3.3V 10% MIN MAX SYMBOL PARAMETER XTAL1 UART Crystal Frequency 24 24 24 MHz ECLK External Clock Frequency 30 50 64 MHz TECLK External Clock Time Period 15 9 7 ns TAS Address Setup Time (16 Mode) 0 0 0 ns TAH Address Hold Time (16 Mode) 0 0 0 ns TCS Chip Select Width (16 Mode) 90 60 35 ns TRD IOR# Strobe Width (16 Mode) 90 60 35 ns TDY Read Cycle Delay (16 Mode) 90 60 35 ns TRDV Data Access Time (16 Mode) 85 55 30 ns TDD Data Disable Time (16 Mode) 25 10 5 ns TWR IOW# Strobe Width (16 Mode) 90 60 35 ns TDY Write Cycle Delay (16 Mode) 90 60 35 ns TDS Data Setup Time (16 Mode) 30 15 10 ns TDH Data Hold Time (16 Mode) 3 3 3 ns TADS Address Setup (68 Mode) 5 0 0 ns TADH Address Hold (68 Mode) 0 0 0 ns TRWS R/W# Setup to CS# (68 Mode) 0 0 0 ns TRDA Data Access Time (68 mode) 85 55 30 ns TRDH Data Disable Time (68 mode) 15 15 15 ns TWDS Write Data Setup (68 mode) 15 10 10 ns TWDH Write Data Hold (68 Mode) 3 3 3 ns TRWH CS# De-asserted to R/W# Deasserted (68 Mode) 3 3 3 ns TCSL CS# Strobe Width (68 Mode) 90 60 35 ns TCSD CS# Cycle Delay (68 Mode) 90 60 35 ns TWDO Delay From IOW# To Output 50 44 50 50 UNIT ns XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 AC ELECTRICAL CHARACTERISTICS TA = -40O TO +85OC, VCC IS 1.62 TO 3.6V, 70 PF LOAD WHERE APPLICABLE LIMITS 1.8V 10% MIN MAX LIMITS 2.5V 10% MIN MAX LIMITS 3.3V 10% MIN MAX SYMBOL PARAMETER TMOD Delay To Set Interrupt From MODEM Input 50 50 50 ns TRSI Delay To Reset Interrupt From IOR# 50 50 50 ns TSSI Delay From Stop To Set Interrupt 1 1 1 Bclk TRRI Delay From IOR# To Reset Interrupt 45 45 45 ns TSI Delay From Start To Interrupt 45 45 45 ns TINT Delay From Initial INT Reset To Transmit Start 24 Bclk TWRI Delay From IOW# To Reset Interrupt 45 45 45 ns TSSR Delay From Stop To Set RXRDY# 1 1 1 Bclk TRR Delay From IOR# To Reset RXRDY# 45 45 45 ns TWT Delay From IOW# To Set TXRDY# 45 45 45 ns TSRT Delay From Center of Start To Reset TXRDY# 8 8 8 Bclk TRST Reset Pulse Width Bclk Baud Clock 8 24 40 8 24 40 16X or 8X or 4X of data rate FIGURE 16. CLOCK TIMING CLK CLK EXTERNAL CLOCK OSC 45 8 40 UNIT ns Hz XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 17. MODEM INPUT/OUTPUT TIMING IO W # IO W A c t iv e TW RTS# DTR# C h a n g e o f s ta te DO C h a n g e o f s ta te CD# CTS# DSR# C h a n g e o f s ta te C h a n g e o f s ta te TMOD TMOD IN T A c t iv e A c t iv e A c t iv e T RSI IO R # A c t iv e A c t iv e A c t iv e TMOD C h a n g e o f s ta te R I# FIGURE 18. 16 MODE (INTEL) DATA BUS READ TIMING A0-A2 Valid Address TAS TCS Valid Address TAS TAH TAH TCS CS# TDY TRD TRD IOR# TDD TRDV D0-D7 Valid Data TDD TRDV Valid Data RDTm 46 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 19. 16 MODE (INTEL) DATA BUS WRITE TIMING A0-A2 Valid Address Valid Address TAS TAS TAH TCS TAH TCS CS# TDY TWR TWR IOW# TDH TDS D0-D7 TDH TDS Valid Data Valid Data 16Write FIGURE 20. 68 MODE (MOTOROLA) DATA BUS READ TIMING A0-A2 Valid Address TADS TCSL Valid Address TADH CS# TCSD TRWS TRWH R/W# TRDH TRDA D0-D7 Valid Data Valid Data 68Read 47 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 21. 68 MODE (MOTOROLA) DATA BUS WRITE TIMING A0-A2 Valid Address TADS TCSL Valid Address TADH CS# TCSD TRWS TRWH R/W# TWDS D0-D7 T WDH Valid Data Valid Data 68Write FIGURE 22. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] RX INT RXRDY# Start Bit D0:D7 Stop Bit D0:D7 D0:D7 TSSR TSSR TSSR 1 Byte in RHR 1 Byte in RHR 1 Byte in RHR TSSR TSSR Active Data Ready Active Data Ready TRR TRR TSSR Active Data Ready TRR IOR# (Reading data out of RHR) RXNFM 48 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] TX Start Bit (Unloading) IER[1] enabled Stop Bit D0:D7 D0:D7 ISR is read D0:D7 ISR is read ISR is read INT* TWRI TWRI TWRI TSRT TSRT TSRT TXRDY# TWT TWT TWT IOW# (Loading data into THR) *INT is cleared when the ISR is read or when data is loaded into the THR. TXNonFIFO FIGURE 24. RECEIVE READY & INTERRUPT TIMING [FIFO MODE] Start Bit RX S D0:D7 S D0:D7 T Stop Bit D0:D7 S D0:D7 T S D0:D7 T S D0:D7 T S D0:D7 T RX FIFO drops below RX Trigger Level TSSI INT FIFO Empties TSSR RX FIFO fills up to RX Trigger Level or RX Data Timeout RXRDY# First Byte is Received in RX FIFO TRRI TRR IOR# (Reading data out of RX FIFO) RXINTDMA# 49 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 FIGURE 25. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE] TX FIFO Empty TX Start Bit Stop Bit S D0:D7 T (Unloading) IER[1] enabled Last Data Byte Transmitted T S D0:D7 T S D0:D7 T S D0:D7 T S D0:D7 T TSI ISR is read S D0:D7 T ISR is read TSRT INT* TX FIFO fills up to trigger level TXRDY# Data in TX FIFO TX FIFO Empty TWRI TX FIFO drops below trigger level TWT IOW# (Loading data into FIFO) *INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level. 50 TXDMA# XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 PACKAGE DIMENSIONS (32 PIN QFN - 5 X 5 X 0.9 mm) Note: the actual center pad is metallic and the size (D2) is device-dependent with a typical tolerance of 0.3mm Note: The control dimension is in millimeter. INCHES MILLIMETERS SYMBOL MIN MAX MIN MAX A 0.031 0.039 0.80 1.00 A1 0.000 0.002 0.00 0.05 A3 0.006 0.010 0.15 0.25 D 0.193 0.201 4.90 5.10 D2 0.138 0.150 3.50 3.80 b 0.007 0.012 0.18 0.30 e 0.0197 BSC 0.50 BSC L 0.012 0.020 0.35 0.45 k 0.008 - 0.20 - 51 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm) D D1 36 25 24 37 D1 13 48 1 2 1 B e A2 C A Seating Plane A1 L Note: The control dimension is the millimeter column INCHES MILLIMETERS SYMBOL MIN MAX MIN MAX A 0.039 0.047 1.00 1.20 A1 0.002 0.006 0.05 0.15 A2 0.037 0.041 0.95 1.05 B 0.007 0.011 0.17 0.27 C 0.004 0.008 0.09 0.20 D 0.346 0.362 8.80 9.20 D1 0.272 0.280 6.90 7.10 e 0.020 BSC 0.50 BSC L 0.018 0.030 0.45 0.75 a 0x 7x 0x 7x 52 D XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 PACKAGE DIMENSIONS (25 PIN BGA - 3 X 3 X 0.8 mm) 5 4 3 2 1 A1 corner A B D C D1 D E D1 D (A1 corner feature is mfger option) Seating Plane A A1 b A2 e Note: The control dimension is the millimeter column INCHES MILLIMETERS SYMBOL MIN MAX MIN MAX A 0.028 0.031 0.70 0.80 A1 0.005 0.007 0.13 0.19 A2 0.022 0.024 0.57 0.61 D 0.114 0.122 2.90 3.10 D1 b e 0.079 BSC 0.008 2.00 BSC 0.012 0.020 BSC 0.20 0.30 0.50 BSC 53 XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 REVISION HISTORY DATE REVISION September 2008 Rev 1.0.0 DESCRIPTION Final Datasheet. NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user's specific application. While the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances. Copyright 2008 EXAR Corporation Datasheet September 2008. Send your UART technical inquiry with technical details to hotline: uarttechsupport@exar.com. Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited. 54 XR16M580 REV. 1.0.0 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO GENERAL DESCRIPTION................................................................................................ 1 FEATURES .................................................................................................................................................... 1 APPLICATIONS .............................................................................................................................................. 1 FIGURE 1. XR16M580 BLOCK DIAGRAM .......................................................................................................................................... 1 FIGURE 2. PIN OUT ASSIGNMENT FOR 32-PIN QFN AND 48-PIN TQFP PACKAGES IN 16 AND 68 MODE............................................. 2 FIGURE 3. PIN OUT ASSIGNMENT FOR 25-PIN BGA PACKAGE........................................................................................................... 3 ORDERING INFORMATION ............................................................................................................................... 3 PIN DESCRIPTIONS ........................................................................................................ 4 1.0 PRODUCT DESCRIPTION ...................................................................................................................... 6 2.0 FUNCTIONAL DESCRIPTIONS .............................................................................................................. 7 2.1 CPU INTERFACE ................................................................................................................................................ 7 FIGURE 4. XR16M580 TYPICAL INTEL/MOTOROLA DATA BUS INTERCONNECTIONS ............................................................................ 7 2.2 SERIAL INTERFACE........................................................................................................................................... 8 FIGURE 5. XR16M580 TYPICAL SERIAL INTERFACE CONNECTIONS ................................................................................................... 8 FIGURE 6. XR16M580 TYPICAL SERIAL INTERFACE CONNECTIONS ................................................................................................... 9 2.3 DEVICE RESET ................................................................................................................................................. 10 2.4 INTERNAL REGISTERS.................................................................................................................................... 10 2.5 INT OUPUT ........................................................................................................................................................ 10 TABLE 1: INT PIN OPERATION FOR TRANSMITTER ........................................................................................................................... 10 TABLE 2: INT PIN OPERATION FOR RECEIVER ................................................................................................................................ 10 2.6 CRYSTAL OSCILLATOR OR EXTERNAL CLOCK INPUT.............................................................................. 11 FIGURE 7. TYPICAL CRYSTAL CONNECTIONS .................................................................................................................................. 11 2.7 PROGRAMMABLE BAUD RATE GENERATOR WITH FRACTIONAL DIVISOR ........................................... 12 2.7.1 INDEPENDENT TX/RX BRG......................................................................................................................................... 12 FIGURE 8. BAUD RATE GENERATOR ............................................................................................................................................... 13 TABLE 3: TYPICAL DATA RATES WITH A 24 MHZ CRYSTAL OR EXTERNAL CLOCK AT 16X SAMPLING ................................................... 13 2.8 TRANSMITTER.................................................................................................................................................. 14 2.8.1 TRANSMIT HOLDING REGISTER (THR) - WRITE ONLY........................................................................................... 2.8.2 TRANSMITTER OPERATION IN NON-FIFO MODE .................................................................................................... FIGURE 9. TRANSMITTER OPERATION IN NON-FIFO MODE .............................................................................................................. 2.8.3 TRANSMITTER OPERATION IN FIFO MODE ............................................................................................................. FIGURE 10. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE ................................................................................... 14 14 14 15 15 2.9 RECEIVER ......................................................................................................................................................... 15 2.9.1 RECEIVE HOLDING REGISTER (RHR) - READ-ONLY .............................................................................................. 15 FIGURE 11. RECEIVER OPERATION IN NON-FIFO MODE .................................................................................................................. 16 FIGURE 12. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE ....................................................................... 16 2.10 AUTO RTS (HARDWARE) FLOW CONTROL ................................................................................................ 17 2.11 AUTO RTS HYSTERESIS ............................................................................................................................... 17 TABLE 4: AUTO RTS (HARDWARE) FLOW CONTROL ........................................................................................................................ 17 2.12 AUTO CTS FLOW CONTROL......................................................................................................................... 17 FIGURE 13. AUTO RTS AND CTS FLOW CONTROL OPERATION ....................................................................................................... 18 2.13 AUTO XON/XOFF (SOFTWARE) FLOW CONTROL...................................................................................... 19 TABLE 5: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ............................................................................................................... 19 2.14 SPECIAL CHARACTER DETECT.................................................................................................................. 19 2.15 NORMAL MULTIDROP MODE........................................................................................................................ 19 2.15.1 AUTO ADDRESS DETECTION .................................................................................................................................. 20 2.16 INFRARED MODE ........................................................................................................................................... 20 FIGURE 14. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING .......................................................................... 21 2.17 SLEEP MODE WITH AUTO WAKE-UP AND POWER-SAVE FEATURE ...................................................... 21 2.17.1 SLEEP MODE ............................................................................................................................................................. 21 2.17.2 POWER-SAVE FEATURE .......................................................................................................................................... 22 2.17.3 WAKE-UP INTERRUPT .............................................................................................................................................. 22 2.18 INTERNAL LOOPBACK................................................................................................................................. 23 FIGURE 15. INTERNAL LOOPBACK ................................................................................................................................................... 23 3.0 UART INTERNAL REGISTERS............................................................................................................. 24 TABLE 6: UART INTERNAL REGISTERS .................................................................................................................................. 24 TABLE 7: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ......................................... 25 4.0 INTERNAL REGISTER DESCRIPTIONS .............................................................................................. 26 4.1 RECEIVE HOLDING REGISTER (RHR) - READ- ONLY .................................................................................. 26 4.2 TRANSMIT HOLDING REGISTER (THR) - WRITE-ONLY ............................................................................... 26 4.3 INTERRUPT ENABLE REGISTER (IER) - READ/WRITE ................................................................................ 26 4.3.1 IER VERSUS RECEIVE FIFO INTERRUPT MODE OPERATION ............................................................................... 27 I XR16M580 1.62V TO 3.63V HIGH PERFORMANCE UART WITH 16-BYTE FIFO REV. 1.0.0 4.3.2 IER VERSUS RECEIVE/TRANSMIT FIFO POLLED MODE OPERATION .................................................................. 27 4.4 INTERRUPT STATUS REGISTER (ISR) - READ-ONLY .................................................................................. 28 4.4.1 INTERRUPT GENERATION: ........................................................................................................................................ 28 4.4.2 INTERRUPT CLEARING: ............................................................................................................................................. 28 TABLE 8: INTERRUPT SOURCE AND PRIORITY LEVEL ....................................................................................................................... 29 4.5 FIFO CONTROL REGISTER (FCR) - WRITE-ONLY......................................................................................... 30 TABLE 9: TRANSMIT AND RECEIVE FIFO TRIGGER TABLE AND LEVEL SELECTION ............................................................................ 31 4.6 LINE CONTROL REGISTER (LCR) - READ/WRITE......................................................................................... 31 TABLE 10: PARITY SELECTION ........................................................................................................................................................ 32 4.7 MODEM CONTROL REGISTER (MCR) OR GENERAL PURPOSE OUTPUTS CONTROL - READ/WRITE.. 32 TABLE 11: INT OUTPUT MODES ..................................................................................................................................................... 33 4.8 LINE STATUS REGISTER (LSR) - READ ONLY.............................................................................................. 4.9 MODEM STATUS REGISTER (MSR) - READ ONLY ....................................................................................... 4.10 MODEM STATUS REGISTER (MSR) - WRITE ONLY .................................................................................... 4.11 SCRATCH PAD REGISTER (SPR) - READ/WRITE ....................................................................................... 4.12 ENHANCED MODE SELECT REGISTER (EMSR) - WRITE-ONLY ............................................................... 34 35 36 36 37 TABLE 12: SCRATCHPAD SWAP SELECTION .................................................................................................................................... 37 4.13 BAUD RATE GENERATOR REGISTERS (DLL, DLM AND DLD) - READ/WRITE ....................................... 38 TABLE 13: SAMPLING RATE SELECT ............................................................................................................................................... 38 TABLE 14: BRG SELECT ................................................................................................................................................................ 38 4.14 RX/TX FIFO LEVEL COUNT REGISTER (FC) - READ-ONLY ....................................................................... 39 4.15 FEATURE CONTROL REGISTER (FCTR) - READ/WRITE............................................................................ 39 4.16 ENHANCED FEATURE REGISTER (EFR) - READ/WRITE ........................................................................... 40 TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS ........................................................................................................................ 40 4.17 SOFTWARE FLOW CONTROL REGISTERS (XOFF1, XOFF2, XON1, XON2) - READ/WRITE................... 41 TABLE 16: UART RESET CONDITIONS ...................................................................................................................................... 42 ABSOLUTE MAXIMUM RATINGS.................................................................................. 43 TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%) 43 ELECTRICAL CHARACTERISTICS ............................................................................... 43 DC ELECTRICAL CHARACTERISTICS ............................................................................................................. 43 AC ELECTRICAL CHARACTERISTICS ............................................................................................................. 44 TA = -40O TO +85OC, VCC IS 1.62 TO 3.6V, 70 PF LOAD WHERE APPLICABLE ............................................. 44 FIGURE 16. CLOCK TIMING ............................................................................................................................................................. FIGURE 17. MODEM INPUT/OUTPUT TIMING .................................................................................................................................... FIGURE 18. 16 MODE (INTEL) DATA BUS READ TIMING ................................................................................................................... FIGURE 19. 16 MODE (INTEL) DATA BUS WRITE TIMING.................................................................................................................. FIGURE 20. 68 MODE (MOTOROLA) DATA BUS READ TIMING .......................................................................................................... FIGURE 22. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] ............................................................................................ FIGURE 21. 68 MODE (MOTOROLA) DATA BUS WRITE TIMING ......................................................................................................... FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] .......................................................................................... FIGURE 24. RECEIVE READY & INTERRUPT TIMING [FIFO MODE] .................................................................................................... FIGURE 25. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE] .................................................................................................. 45 46 46 47 47 48 48 49 49 50 PACKAGE DIMENSIONS (32 PIN QFN - 5 X 5 X 0.9 mm) .............................................. 51 PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm) ............................................... 52 PACKAGE DIMENSIONS (25 PIN BGA - 3 X 3 X 0.8 mm).............................................. 53 REVISION HISTORY...................................................................................................................................... 54 II