CSM_G2R-_-S_DS_E_3_4
1
General-purpose Relay
G2R-@-S
Slim and Space-saving Power Plug-in Relay
Lockable test button models now available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
High switching power (1-pole: 10 A).
Environment-friendly (Cd, Pb free).
Wide range of Sockets also available.
Model Number Structure
Model Number Legend
1. Relay Function
Blank: General-purpose
2. Number of Poles
1: 1 pole
2: 2 poles
3. Contact Form
Blank: SPDT
4. Contact Type
Blank: Single
5. Terminals
S: Plug-in
6. Classification
Blank: General-purpose
N: LED indicator
D: Diode
ND: LED indicator and diode
NI: LED indicator with test button
NDI: LED indicator and diode with test button
7. Rated Coil Voltage
Ordering Information
List of Models
Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina-
tions with the P2RF-E and P2RF-S. The Relays bear the CE Marking.
2. Refer to Connecting Sockets, below, for applicable Socket models.
3.
LR
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
G2R - -
1234 56 7
Whenyourorder,specifytheratedvoltage.
Classification Enclosure
rating Coil ratings Contact form
SPDT DPDT
Plug-in terminal
General-purpose
Unsealed
AC/DC
G2R-1-S G2R-2-S
LED indicator G2R-1-SN G2R-2-SN
LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S)
Diode
DC
G2R-1-SD G2R-2-SD
LED indicator and diode G2R-1-SND G2R-2-SND
LED indicator and diode with test button G2R-1-SNDI (S) G2R-2-SNDI (S)
When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
Example: G2R-1-S 12 VDC (S) New model
Rated coil voltage
2
G2R-@-S
Accessories (Order Separately)
Connecting Sockets
Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Accessories for Screwless Clamp Terminal Socket (Option)
Mounting Tracks
* Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
* The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
Applicable Relay model Track/surface-mounting Socket Back-mounting Socket
Screwless clamp terminal Screw terminal Terminals Model
1 pole
G2R-1-S(N)(D)(ND)(NI)(NDI)
P2RF-05S (See note.)
+
(P2CM-S (option))
P2RF-05-E
P2RF-05
PCB terminals P2R-05P, P2R-057P
Solder terminals P2R-05A
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
P2RF-08S (See note.)
+
(P2CM-S (option))
P2RF-08-E
P2RF-08
PCB terminals P2R-08P, P2R-087P
Solder terminals P2R-08A
Name Model
Clip & Release Lever P2CM-S
Nameplate R99-11 Nameplate for MY
Socket Bridge
P2RM-SR (for AC), P2RM-SB (for DC)
Applicable Socket Description Model
Track-connecting Socket
Mounting track
50 cm (l) x 7.3 mm (t): PFP-50N
1 m (l) x 7.3 mm (t): PFP-100N
1 m (l) x 16 mm (t): PFP-100N2
End plate PFP-M
Spacer PFP-S
Back-connecting Socket Mounting plate P2R-P*
Rated voltage
Rated current* Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage Power
consumption
(approx.)
50 Hz 60 Hz Armature
OFF
Armature
ON % of rated voltage
AC
24 V 43.5 mA 37.4 mA 253 Ω0.81 1.55
80% max. 30% max. 110% 0.9 VA at 60 Hz
110 V 9.5 mA 8.2 mA 5,566 Ω13.33 26.83
120 V 8.6 mA 7.5 mA 7,286 Ω16.13 32.46
230 V 4.4 mA 3.8 mA 27,172 Ω72.68 143.90
240 V 3.7 mA 3.2 mA 30,360 Ω90.58 182.34
Rated voltage Rated current* Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage Power
consumption
(approx.)
Armature
OFF
Armature
ON % of rated voltage
DC
6 V 87.0 mA 69 Ω0.25 0.48
70% max. 15% min. 110% 0.53 W
12 V 43.2 mA 278 Ω0.98 2.35
24 V 21.6 mA 1,113 Ω3.60 8.25
48 V 11.4 mA 4,220 Ω15.2 29.82
G2R-@-S
3
Contact Ratings
Note: P level: λ60 = 0.1 x 10-6/operation
Characteristics
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted.
Approved Standards
UL 508 (File No. E41643)
CSA 22.2 No.0, No.14
(File No. LR31928)
IEC/VDE (EN61810)
LR
Number of poles 1 pole 2 poles
Load Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Rated load 10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current 10 A 5 A
Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 10 A 5 A
Max. switching power 2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Failure rate (reference value) 100 mA at 5 VDC 10 mA at 5 VDC
Item 1 pole 2 poles
Contact resistance 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Endurance
Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Ambient temperature Operating: –40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 21 g
Model Coil ratings Contact
form Contact ratings Oper-
ations
G2R-1-S
5 to 110 VDC
6 to 240 VAC
SPDT
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
G2R-2-S DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Model Coil ratings Contact
form Contact ratings Oper-
ations
G2R-1-S
5 to 110 VDC
6 to 240 VAC
SPDT
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
G2R-2-S DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Contact
form Coil ratings Contact ratings Operations
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 x 103
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms) 100 x 103
Number
of poles Coil ratings Contact ratings Operations
1 pole 5 to 110 VDC
6 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
100 x 103
2 poles 5 to 110 VDC
6 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 x 103
4
G2R-@-S
Engineering Data
Maximum Switching Power
Plug-in Relays
Endurance
Plug-in Relays
Ambient Temperature vs Maximum Coil Voltage
100
10
1
0.1 1 10 100 1000
100
10
1
0.11 10 100 1000
G2R-1-S
Switching current (A)
Switching voltage (V)
G2R-2-S
Switching voltage (V)
Switching current (A)
AC inductive load
(cosφ = 0.4) AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
AC inductive load
(cosφ = 0.4) AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
5,000
1,000
500
100
50
5,000
1,000
500
100
50
10,000
G2R-1-S
Endurance (x103 operations)
Switchin
g
current (A)
G2R-2-S
Switchin
g
current (A)
30-VDC inductive load (L/R = 7ms)
30-VDC inductive load (L/R = 7ms)
Endurance (x103 operations)
250-VAC/30-VDC
resistive load
250-VAC inductive load
(cosφ = 0.4)
250-VAC/30-VDC
resistive load
250-VAC
inductive load
(cosφ = 0.4)
Ambient temperature (°C)
Note: The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Maximum voltage (%)
DC coil
AC coil
G2R-@-S
5
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Relays with Plug-in Terminals
SPDT Relays
DPDT Relays
G2R-1-S, G2R-1-SN, G2R-1-SNI (S)
G2R-1-SD, G2R-1-SND, G2R-1-SNDI (S) Terminal Arrangement/Internal Connections
(Bottom View)
1
234
5
DC24V
201
0.5 4.75
7.5
17.5
5.25.2
35.5 max.
29 max. 13 max.
5
G2R-1-SND, G2R-1-SNDI (DC)
G2R-1-S G2R-1-SD (DC)
G2R-1-SN, G2R-1-SNI (AC) G2R-1-SN, G2R-1-SNI (DC)
1
23
4
524
5
1
3
24
5
1
3
1
23
4
5
G2R-2-S, G2R-2-SN, G2R-2-SNI (S)
G2R-2-SD, G2R-2-SND, G2R-2-SNDI (S) Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-SND, G2R-2-SNDI (DC)
G2R-2-S G2R-2-SD (DC)
G2R-2-SN, G2R-2-SNI (AC) G2R-2-SN, G2R-2-SNI (DC)
20
0.5
55
2.5
2.4
19.4
29 max.
35.5 max.
13 max.
6.2
7.4
8.9
1
8
234
765
234
567
1
8
234
765
1
8
234
765
1
8
1
8
234
765
6
G2R-@-S
Track/Surface Mounting Sockets
Accessories for P2RF-@-S
Socket Bridge Clip and Release Lever
32.6
27.6
22.6
24.5
35.4
28.5
32.6
(5.3)
92.0 max.
18.0 max.
38.2 max.
36.5 max.
Standard model Option (with ejector and
label attached)
P2RF-05-S Terminal Arrangement
(Top View)
11
14
12
A1 A2
32.6
27.6
22.6
24.5
35.4
(3.4)
28.6
32.6
(5.3)
92.0 max.
18.0 max.
38.2 max.
36.5 max.
Standard model Option (with ejector
and label attached)
P2RF-08-S
Terminal Arrangement
(Top View)
11
14
12
A1 A2
21
24
22
L
914
Insulating coating
1.2 dia. conductor (See note 1.) 16.8 40.35
36
G2R-@-S
7
39.5±0.1
P2RF-05
P2RF-08
7
4
2
35.5
19.5
30±0.05
7
4
2
35.5
19.5
30±0.05
P2RF-05-E
39.5
35.5
11.5
(11)
(12)
(14)
(A1)
(A2) 1
2
3
4
5
39.5±0.1
21.5
5
2
3
39.5
35.5
11.5
P2RF-08-E
8
6 3
72
54
(A1)
(A2)
(21)
(22)
(24)
(11)
(12)
(14)
1
2
3.2-dia.
hole
P2RF-05
P2RF-08
Five, M3.5 x 8
19.5 max.
4-dia. holes
30 max.
54 max.
4.2-dia. hole
71.5 max.
19.5 max.
Eight, M3.5 x 8
4-dia. holes
30 max.
54 max.
4.2-dia. hole
P2RF-05-E
3.2-dia.
hole
Five, M3.5×7
85.5 max.
16.0 max.
48 max.
Note: Pin numbers in parentheses apply to DIN standard.
61 max.
Eight, M3×8
3.5-dia. hole
16.0 max.
48.0 max.
61.0
max.
P2RF-08-E
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
M3 or
3.5-dia.
hole
M3 or
3.5-dia.
hole
3.5-dia.
hole
85.5
max.
M3 or 3.2-dia.
hole
M3 or 3.2-dia.
hole
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
71.5 max.
8
G2R-@-S
Mounting Height of Relay with Track/Surface Mounting Sockets
Back-connecting Sockets
P2RF-@P2RF-@-E
67.0 70.5
66.5 62.0
28.6
65.0
(5.30)
P2RF-@-S
72.0
147
6
4.5
15
4
3.5
1.2
1.5
74
4
6
4.5
15
4
7
47
0.3
5
5
20
1
2.8
1.5
7.5
7.5
5
5
20
(4.3)
(5)
P2R-05P (1-pole) 14.5 max.
35.5 max.
Tolerance: ±0.1
Mounting Holes
P2R-08P (2-pole)
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
Eight, 1.3-dia. holes
Terminal Arrangement
(Bottom View)
Mounting HolesTerminal Arrangement
(Bottom View)
Five,
1.6-dia.
holes
36.5 max.
G2R-@-S
9
Mounting Height of Relay with Back-connecting Sockets
7
5
1.2
0.3
6.7
3.8
16.7 5
6
7
1.2
0.3
5
7
5
20
2.8
2.6
7.5
13.6±0.1
30.5±0.2
1.5
P2R-05A (1-pole)
Panel Cutout
P2R-08A (2-pole)
Five, 3 x 1.8-dia. holes
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
Eight, 3 x 1.2-dia. holes
Terminal Arrangement
(Bottom View)
Recommended thickness of
the panel is 1.6 to 2.0 mm
P2R-057P
P2R-087P
4.5±0.1 15±0.1
4±0.1
5
4±0.1
6±0.1
7±0.1
7.5
5
5
20
(8.1)
29.6
0.7
8.9
8.7
8.7
16.4
10.4
1
7.4
29.1
7.5
16.4
110.4
7.4
14 max.
37 max.
41 max.
14 max.
37 max.
41 max.
Mounting HolesTerminal Arrangement
(Bottom View)
Mounting HolesTerminal Arrangement
(Bottom View) Eight,
1.3-dia.
holes
Five,
1.6-dia.
holes
44.5
38.0
G2R-@7P
G2R Relay
P2R-_P
Socket P2R-_A
Socket
G2R Relay
G2R-@P G2R-@A
47.5
10
G2R-@-S
Mounting Tracks
End Plate Spacer
Precautions
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay cir-
cuits.
If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
Precautions for P2RF-@-S Connection
Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
PFP-100N, PFP-50N PFP-100N2
4.5
15 25 25 25 25
10 10
1,000 (500)
7.3±0.15
35±0.3 27±0.15
1
4.5
15 25 25 25 25 15
10 10
1,000
35±0.3 27 24
16
29.
2
1 1.5
15 (5)
It is recommended to use a panel 1.6 to 2.0 mm thick.
PFP-M PFP-S
50
11.5
10
6.2 1.8
1
35.5 35.3
1.8
1.3
4.8
5
16
12
44.3 34.8
10
16.5
M4 x 8 pan
head screw
Cation
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.