Modular DIN-rail design with color-coding & rejection
feature makes it easy to identify, install & maintain.
Built-in overcurrent protection eliminates the need for
any additional fuse installation and wiring.
easyID™ Visual indication and optional remote
contact signaling make status monitoring simple.
Patented, fast-acting Short-Circuit Interrupting (SCI)
technology responds efficiently to overvoltage conditions.
The Only, True UL 1449 3rd Edition
Recognized SPD to Protect Your
PV Investment from Damaging
Surges and Overvoltages
Surge Protection Made Simple
Photovoltaic Applications
See data sheet #2055 • www.cooperbussmann.com/surge
©2010 Cooper Bussmann
www.cooperbussmann.com
Reorder # 3164 1010 5M Printed in USA
The Need for Surge Protection
The unique nature of PV installations make them
vulnerable to overvolatges and surges from lightning
strikes and static discharges.
These surges need to be intercepted before they take
down the entire system by damaging the PV arrays,
charge controller/inverter and combiner boxes.
In any PV system, it is vital that surge suppressor
elements that are subject to wear, are easily monitored
for performance.
The Cooper Bussmann PV Surge Suppression systems
provide standard easyID™ visual indication and remote
contact signaling to keep system maintainers apprised
of the protection level being delivered.
Safe and Simple
IP20 Finger-safe construction and suppressor
rejection feature make it easy to know the suppressor
system is installed and properly operating to protect
your PV system investment.
Simply specify the system voltage and whether the
remote contact signaling is desired.
Five year limited warranty.*
Complete Line of Surge Protection Solutions
Cooper Bussmann offers surge protection products for
UL, IEC, wind power and telecom applications.
PV Wind Telecom UL IEC
Ordering Information
Maximum continuous operating voltage for PV applications [UCPV] 600Vdc 1000Vdc 1200Vdc
Catalog Numbers: Without Remote Signaling BSPH3600YPV BSPH31000YPV BSPH31200YPV
(Base + Modules) With Remote Signaling BSPH3600YPVR BSPH31000YPVR BSPH31200YPVR
Replacement Modules: Outer (2) BPH300YPV BPH500YPV BPH600YPV
Center (1) BPM300YPV BPM500YPV BPM600YPV
Typical Application Schematics
Equipment
Grounding
Conductor
Common
Equipment
Grounding
Conductor
Common
Application A
600, 1000 & 1200Vdc systems
Application B
600Vdc systems only
Base & Module Number System
BSP H3600 YPV R
Product Series
Technology
- H = Hybrid
Number of Poles
System DC Voltage
- 600 = up to 600Vdc
- 1000 = up to 1000Vdc
- 1200 = up to 1200Vdc
System Type
- YPV = PV System in “Y” configuration
Optional Remote Contact Signaling
- R = Includes remote switch option
- Blank = No remote switch option
Replacement Module Number System
BP H300 YPV
Product Series
Technology
- M = MOV
- H = Hybrid
MCOV
- 300 = 300Vdc (for 600V systems)
- 500 = 500Vdc (for 1000V systems)
- 600 = 600Vdc (for 1200V systems)
System Type
- YPV = PV System in “Y” configuration
* See Cooper Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Eaton:
BPH300YPV BPH500YPV BPM300YPV BPM500YPV BPM600YPV