VS2 Series Convergent Mode Sensors
Miniature self-contained sensors
Printed in USA 10/00 P/N 65411L0A
VS2 Series Convergent Mode Sensor Features
Extremely low profile self-contained miniature sensors
10 to 30V dc operation
Visible red sensing beam
Choose models with 15 mm or 30 mm convergent point
Choose dark or light operate models
Choose models with NPN (sinking) or PNP (sourcing) output
3-wire hookup; output load capacity to 50 mA
Choice of integral cable or quick-disconnect connector
Models* Range Cable Supply
Voltage Output
Type Excess Gain Beam Pattern
VS2AN5CV15
VS2AN5CV15Q
15 mm
(0.6")
±5 mm
2 m (6.5')
3-Pin Pico QD
10 to
30V dc
NPN
Light
Operate
1
10
100
10 mm
0.4 in 100 mm
4 in 1000 mm
40 in
1 mm
0.04 in
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
VS2CV15
Convergent Mode
100 mm
4.0 in
80 mm
3.2 in
60 mm
2.4 in
40 mm
1.6 in
20 mm
.8 in
0
0
2 mm
4 mm
6 mm
2 mm
4 mm
6 mm
0
0.08 in
0.16 in
0.24 in
0.08 in
0.16 in
0.24 in
DISTANCE
VS2CV15
Convergent Mode
VS2 Series Over view
VS2 Series miniature self-contained sensors are designed for precision sensing in small areas previously accessible only to remote
or fiber optic models. Typical applications include mounting inside vibrating feeders and electronic component
handling equipment, where larger sensors will not fit.
Visible red, 660 nm
VS2 Series Convergent-Mode Sensors
VS2RN5CV15
VS2RN5CV15Q 2 m (6.5')
3-Pin Pico QD
NPN
Dark
Operate
VS2AP5CV15
VS2AP5CV15Q 2 m (6.5')
3-Pin Pico QD
PNP
Light
Operate
VS2RP5CV15
VS2RP5CV15Q 2 m (6.5')
3-Pin Pico QD
PNP
Dark
Operate
VS2AN5CV30
VS2AN5CV30Q
30 mm
(1.2")
±10 mm
2 m (6.5')
3-Pin Pico QD
NPN
Light
Operate
1
10
100
10 mm
0.4 in 100 mm
4 in 1000 mm
40 in
1 mm
0.04 in
E
X
C
E
S
S
G
A
I
N
DISTANCE
1000
VS2CV30
Convergent Mode
200 mm
8.0 in
160 mm
6.4 in
120 mm
4.8 in
80 mm
3.2 in
40 mm
1.6 in
0
0
3 mm
6 mm
9 mm
3 mm
6 mm
9 mm
0
0.12 in
0.24 in
0.36 in
0.12 in
0.24 in
0.36 in
DISTANCE
VS2CV30
Convergent Mode
VS2RN5CV30
VS2RN5CV30Q 2 m (6.5')
3-Pin Pico QD
NPN
Dark
Operate
VS2AP5CV30
VS2AP5CV30Q 2 m (6.5')
3-Pin Pico QD
PNP
Light
Operate
VS2RP5CV30
VS2RP5CV30Q 2 m (6.5')
3-Pin Pico QD
PNP
Dark
Operate
See Safety Use Warning on Back Page.
VS2 Series Convergent Mode
page 2Banner Engineering Corp. Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
VS2 Series Specifications
Supply Voltage and Current
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Configuration SPST solid-state switch
Choose NPN (current sinking) or PNP (current sourcing) models
Choose light operate (N.O.) or dark operate (N.C.) models
Output Rating 50 mA maximum
Off-state leakage current: < 1 microamp at 24V dc
On-state saturation voltage: < 0.25V at 10 mA dc; < 0.5V at 50 mA dc
Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short circuit of outputs
Overload trip point 100 mA
Output Response Time 1 millisecond ON and OFF
(NOTE: 150 millisecond delay maximum on power-up: output does not conduct during this time)
Indicators Two LEDs: Green and Yellow
GREEN ON steadily = power to sensor is ON
GREEN flashing = output overload
YELLOW ON steadily = light is sensed
Repeatability 160 microseconds
Construction Black ABS housing with acrylic lens
Environmental Rating IEC IP67; NEMA 6
Connections 2 m (6.5') attached cable: three #28 ga stranded conductors with PE insulation; PVC outer cable jacket;
or 3-pin Pico-style pigtail quick-disconnect fitting. QD cables are ordered separately.
Operating Conditions Temperature: -20° to +55°C (-4° to +131°F)
Maximum Relative Humidity: 80% at 50°C (non-condensing)
Vibration and
Mechanical Shock Vibration: All models meet IEC 60068-2-6, IEC 60947-5-2, UL491 Section 40, MIL-STD-202F Method 201A;
10 to 60 Hz, 0.5 mm peak to peak
Shock: All models meet IEC 60068-2-27, IEC 60947-5-2; 30g peak acceleration, 11 millisecond pulse
duration, half-sine wave pulse shape
10 to 30V dc (10% maximum ripple) at less than 25 mA (exclusive of load)
Certifications
Application Notes M2 stainless steel mounting hardware included. Optional mounting brackets are available (page 4).
VS2 Series Sensor Hookups
10-30V dc
+
bu
bn
bk Load
10-30V dc
+
bn
bu
bk Load
10-30V dc
+
bu
bn
bk Load
10-30V dc
+
bn
bu
bk Load
Sensors with NPN Outputs
Cabled hookup
Quick-Disconnect hookup Quick-Disconnect hookup
Sensors with PNP Outputs
Cabled hookup
VS2 Series Convergent Mode
page 3
Banner Engineering Corp. Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
VS2 Series Convergent Mode Sensor Dimensions
C
L
2x ø2.2 mm
(0.09")
3.6 mm
(0.14")
4.7 mm
(0.19")
2.0 mm
(0.08")
8.0 mm
(0.31")
Green Power
Indicator
Yellow
Signal Indicator
(Receiver only)
12.0 mm
(0.47")
4.8 mm
(0.19")
25.1 mm
(0.99")
VS2CV30
21.2 mm
(0.84")
VS2CV15
20.6 mm
(0.81") 10.9 mm
(0.43")
150 mm (6") Pigtail
Accessories
Quick-Disconnect (QD) Cables
Style Models Length For Use With Dimensions Pinout
3-pin Pico Style
Straight
PKG3M-2
PKG3M-9
2 m (6.5')
9 m (30')
All VS2 Series sensors
with model suffix “Q”.
34.7 mm
(1.37")
9.6 mm
(0.38")
M8 x 1 Black Wire
Blue Wire Brown Wire
VS2 Series Mounting Brackets
SMBVS2RA Right-angle bracket
300 series stainless steel
5.5 mm
(0.22")
7.0 mm
(0.28")
2x 3.2 mm
(0.13")
0.9 mm
(0.04")
3.0 mm
(0.12")
3.0 mm
(0.12")
14.0 mm
(0.55")
4 x ø2.3 mm
(0.09")
8.0 mm
(0.32")
8.0 mm
(0.32")
8.0 mm
(0.32")
9.0 mm
(0.35")
20.0 mm
(0.79")
20.0 mm
(0.79")
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • Fax: 763.544.3213 • E-mail: sensors@baneng.com
VS2 Series Convergent Mode
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any
other warranty either expressed or implied.
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current
Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
!