1
Thermal-magnetic (TM and AS-line) AS168XDC3
www.schurter.com/PG17_20
Circuit Breakers
Circuit Breaker for Equipment thermal-magnetic, 3 poles
Description
- Thermal-magnetic circuit breaker
- High short circuit performance
- Availability of AC and DC in the same frame size
- DIN-Rail Mounting
Standards
- Approval Reference Type: AS168X
- VDE Certificate Number: IEC 60934
- UL File Number: UL 1077
- CSA File Number: CSA C22.2
Applications
- Industrial appliances
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
Technical Data
General data
Rated Voltage DC IEC 360 V
UL/CSA 360 V
Rated current 0.5 - 50 A , see approbations
Conditional short circuit capa-
city IEC 60934
Icn: DC 360 V: 4.5 kA (no fuse)
Conditional short circuit capa-
city UL 1077
Icn: DC 360 V: 10 kA (no fuse)
Degree of Protection from front side IP 40 acc. to IEC 60529
Dielectric Strength 50 Hz: > 2 kV
Impulse 1.2/50 μs
Vibration Resistance ± 0.75 mm @ 5 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
Insulation Resistance 250/440 VAC > 5 MΩ
Shock Resistance 30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Ambient temperature -10 °C to 55 °C
Weight 100 - 130 g
Tripping Type
Positively trip free
Actuation type Manual ON/OFF
Permissible wire cross section 1.5 - 25 mm² / 16 - 4 AWG
Switched neutral
Rated Voltage AC 277 V
Rated current AC/DC 65 A
Function The switched neutral closes with ma-
nual closure of the poles and opens
automatically with thermal magnetic
tripping of the poles.
Add-on modules
Add-on modules Technical data for the additional module
see separate data sheet
2
Thermal-magnetic (TM and AS-line)
AS168XDC3 www.schurter.com/PG17_20
Circuit Breakers
Dimension
AS168X 3 pole
45
35
90
1.9
44.4
61.6
68.4
5.1
A)
26.6
52.5
B)
A) 35 mm DIN rail EN 50022
B) Max. torque
Wire crosssection Max. torque
1.5 ... 10 mm2 2.5 Nm
16 ... 25 mm2 3.1 Nm
AWG #16 ... 8 20 ... 22 lb –in
AWG #6 ... 4 26 ... 28 lb –in
AS168X 3 pole and switched neutral pole
45
35
90
1.9
44.4
61.6
68.4
5.1
26.6
70
A)
B)
A) 35 mm DIN rail EN 50022
B) Max. torque
Wire crosssection Max. torque
1.5 ... 10 mm2 2.5 Nm
16 ... 25 mm2 3.1 Nm
AWG #16 ... 8 20 ... 22 lb –in
AWG #6 ... 4 26 ... 28 lb –in
3
Thermal-magnetic (TM and AS-line) AS168XDC3
www.schurter.com/PG17_20
Circuit Breakers
Diagrams
AS168X-CB1... AS168X-CB1...N
AS168X-CB1... / AS168X-ACBH1 AS168X-CB1... / AS168X-ACBH2
AS168X-CB1... / AS168X-ACBS1 AS168X-CB1... / AS168X-ACBS2
AS168X-CB1... / AS168X-ACBA
4
Thermal-magnetic (TM and AS-line)
AS168XDC3 www.schurter.com/PG17_20
Circuit Breakers
Approvals
Symbol Standard Rated current Rated voltage DC Conditional short circuit capacity Icn
UL 508
CSA C22.2 no. 14
---
UL 1077 0.5 - 40 A 360 V 10 kA
CSA C22.2 no. 235 - - -
EN 60934 0.5 - 50 A 360 V 4.5 kA
GB 17701 - - -
Effect of ambient temperature
AC-breaker are calibrated for an ambient temperature of +40°C, DC-breakers for +23°C. To determine the rated current for a lower or
higher ambient temperature, use a correction factor from the table below:
Ambient temperature [°C] Correction factor AC version Correction factor DC version
-20 0.78 0.80
-5 0.82 0.87
0 0.83 0.90
+10 0.87 0.95
+23 0.91 1.00
+30 0.95 1.05
+40 1.00 1.10
+50 1.05 1.20
+60 1.11 1.30
Example DC version: Rated current = 10 A; Environmental temperature = 50 °C; --> Correction factor = 1.2; Resulting current = 12 A
Time-Current-Curves
Version DF / Magnetic 4.5-8 xln
Time in Seconds
110 100 1000 x I
n
0,1ms
1ms
10ms
0,1s
1s
10s
100s
1000s
1hr
Multiple of Rated Current In
Reference Temperature +23°
Version DG / Magnetic 9-16 xln
Time in Seconds
110 100 1000 x I
n
0,1ms
1ms
10ms
0,1s
1s
10s
100s
1000s
1hr
Multiple of Rated Current In
Reference Temperature +23°
5
Thermal-magnetic (TM and AS-line) AS168XDC3
www.schurter.com/PG17_20
Circuit Breakers
Version DH / Magnetic 18-32 xln
Time in Seconds
110 100 1000 x I
n
0,1ms
1ms
10ms
0,1s
1s
10s
100s
1000s
1hr
Multiple of Rated Current In
Reference Temperature +23°
Config. Code
AS168X-CB|1|DG|200|N|
The characters are placeholders for the correspondingly keys of selections from the key tables.
AS168X-CB| 1 |DG|200|N| = Number ofPoles
Number of Poles Configuration
key
3 3
AS168X-CB|1| DG |200|N| = Tripping characteristics
Tripping characteristics Configuration
key
1.05-1.35xIn / 4.5-8xIn / 0.5-50 A DF
1.05-1.35xIn / 9-16xIn / 0.5-50 A DG
1.05-1.35xIn / 18-32xIn / 6.0-50 A DH
AS168X-CB|1|DG| 200 |N| = Rated current
Rated current Configuration
key
0.05 A 005
1.0 A 010
1.5 A 015
2.0 A 020
3.0 A 030
4.0 A 040
5.0 A 050
6.0 A 060
7.0 A 070
Other rated currents on request
Rated current Configuration
key
8.0 A 080
9.0 A 090
10.0 A 100
12.0 A 120
15.0 A 150
16.0 A 160
18.0 A 180
20.0 A 200
23.0 A 230
25.0 A 250
27.0 A 270
30.0 A 300
32.0 A 320
35.0 A 350
40.0 A 400
45.0 A 450
50.0 A 500
Other rated currents on request
AS168X-CB|1|DG|200| N | = Switched neutral
Switched neutral Configuration
key
Switched neutral pole N
6
Thermal-magnetic (TM and AS-line)
AS168XDC3 www.schurter.com/PG17_20
Circuit Breakers
Variants
Tripping characteristics Rated current Switched neutral Config. Code Order Number
1.05-1.35xIn / 9-16xIn / 0.5-50 A 2.0 A AS168X-CB3DG020 4420.0607
1.05-1.35xIn / 9-16xIn / 0.5-50 A 20.0 A AS168X-CB3DG200 4420.0940
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging Unit 1 Pcs
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
09.11.2015
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schurter:
4420.0607 4420.0808 4420.0859