EUL/EUH AC/DC voltage control EUL Part number 84872024
Voltage monitoring
2 relays to cover 6 ranges of measurement : 0.2V to 600V
Automatic recognition AC/DC
Frequency up to 500 Hz
Part numbers
Specifications
Type
Measurement range
Supply voltage
84 872 024
EUL
0,2→60V
230 V AC
24 V, 120 V, 230 V, 50/60 Hz (galvanic isolation via transformer)
24 V (no galvanic isolation). In this case, the product power supply and measuring circuit power supply must be electrically isolated.
0,85 1,15 Un
3 VA
/ 1 W
40 500 Hz
Adjustment from 10 to 100 % of the measurement range
Adjustment from 5 to 50 % of the displayed threshold
±
10 % of the full scale
0,1 3 s
±
10 %
1 AgNi changeover, 8 A
max
-
20→+60
-
30→+70
E1
-
M
E2
-
M
E3
-
M
E1
-
M : 0,2 to 2V
E2
-
M : 1 to 10V
E3
-
M : 6 to 60V
E1
-
M : 2k
Ω
E2
-
M : 10k
Ω
E3
-
M : 60k
Ω
Principles
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
When the value of the controlled voltage, AC or DC, reaches the treshold Ue displayed on the front face, the output relay changes state at the end of a time delay T1, which can be set on the front
face at between 0.1 and 3s.
Once the voltage drops below 5 to 50 % of the treshold (hysteresis), the output relay changes state again instantly. Changing the hysteresis onthe front face does not therefore modify the value of
the preset treshold.
When the value of the controlled voltage, AC or DC, reaches the treshold Ue displayed on the front face, the output relay changes state at the end of a time delay T1, which can be set on the front
face at between 0.1 and 3s and remains latched in this position.
N
o
Legend
Treshold Ue
Hysteresis
UPPER function
UNDER function
Unit power-up
Controlled voltage
Principles
N
o
Legend
Treshold Ue
Hysteresis
UPPER function
UNDER function
Unit power-up
Controlled voltage
*** TRADUCTION MANQUANTE ***
Dimensions (mm)
EUL / EUH
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
Connections
EUL
Legend
A1 - A2 : Supply voltage
Connections
EUL / EUH
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
N
o
Legend
Supply voltage to be monitored
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Crouzet:
84872024