MICROCIRCUIT DATA SHEET
MNLM6142AM-X REV 4A1
Revision History
Rev ECN # Rel Date Originator Changes
2A1 M0003061 07/12/00 Shaw Mead MDS: MNLM6142AM-X Rev. 1B1, updated to: MNLM6142AM-X
Rev. 2A1. Change: 5V, Vo at Rl=3k, Min. Limit from
4.8V to 4.77V in subgroup 5. Change: 5V, SR, Min.
Limit from 11V/uS to 10.5V/uS in subgroup 5. Update:
Recommended Operating Conditions. Change: Subgroups
for SR and GBW from functional tests to dynamic tests.
3A1 M0003723 04/28/04 Rose Malone Update MDS: MNLM6142AM-X, Rev. 2A1 to MNLM6142AM-X,
Rev. 3A1. Moved Controlling Document from Main Table
to Features Section. Changed Features Section, Wide
Supply Range and Recommended Operating Conditions
Section, Supply Voltage from 2.7V to 2.8V. Re-ordered
and Updated Notes in Absolute Maximum Section. Updated
Recommended Operating Conditions notes. Removed Rl =
2K condition under DC parametric 5.0V Output Swing.
Changed Slew Rate min. limit from 10.5 to 9.5V/uS
subgroup 5 and Added Cout = 0 in Conditions under AC
parmetric 5.0V. Changed DC/AC Sections referring to
2.7V to 2.8V. Changed Conditions in DC Parameters 2.8V
section CMRR from 0V <Vcm< 1.8V to 0V <Vcm< 1.9V and
0V <Vcm< 2.7V to 0V <Vcm< 2.8V and Vcm Max. limit from
2.7V to 2.8V, AV Rl = 100K, Vo = +1.1V. Changed Vo
Min. limit Subgroup 4 from 2.66 to 2.76V and Subgroup
5,6 from 2.25 to 2.35V.
4A1 M0004375 04/28/04 Rose Malone Update MDS: MNLM6142AM-X, Rev. 3A1 to Rev. 4A1.
Corrected Conditions that applied to all Electricals.
Changed Parameter SR to +SR and the conditions. Added
Parameter -SR. Changed made to reflect the test
program.
9