3-42
3
Thermofit Molded Parts
Adhesives
Applications
Thermofit adhesives are intended to provide an environmental
seal when used with Thermofit molded parts, tubing, and
adapters, and when installed in accordance with installation
procedures.
Thermosets
Product
designation Precoat
designation Type
Operating
temperature
range Available form
S-1006 N/A Epoxy/
polyamide
2-part paste
–55 to 135°C S-1006 Kit A
S-1006 Kit C Ten 3-g packs
Six 2-oz semkits
S-1009 N/A Epoxy/
polymercaptan
2-part paste
–55 to 135°C S-1009 Kit A Ten 3-g packs
1-qt part B
S-1010 N/A VITON cement
2-part liquid –55 to 200°C S-1010 1/2-pint can
with accelerator
S-1044 N/A VITON tape
adhesive –55 to 200°C S-1044-03
S-1044 Primer Tape 3/4" x .018" x 100'
1/2-pint can
S-1125 N/A Epoxy/
polyamide
2-part paste
–55 to 135°C S-1125 Kit 1
S-1125 Kit 3 Five 10-g packs
One 100-g pack
Thermosets
Curing
conditions
Shelf life*
at or
below 25°CCompatible
with material Specifications Comments
96 hrs @ 20°C min. or
1 hr @ 120°C2 years –3, –4, –5, –71 RT-1006
MIL-A-46864 General purpose harnessing adhesive.
Not used on VITON, silicone, or substrates.
24 hrs @ 20°C min. or
1 hr @ 95°C or
45 mins @ 120°C
2 years –3, –4, –5, –71 RT-1009
MIL-A-46864 General purpose harnessing adhesive.
Not used on VITON or
silicone–20 minute pot life.
2 hrs @ 150°C min. or
20 mins @ 200°C1 year –12 RT-1050/10 Used with VITON.
Heat cure required.
2 hrs. @ 150°C min. or
20 mins @ 200°CTape: 1 year
Primer: 1 year –12
–12 RT-1050/22
RT-1050/14 Self-amalgamating tape used with VITON harness
systems. All surfaces should be primed with S-1044
primer. Heat cure required: 2 hrs @ 150°C.
24 hrs @ 20°C min. or 18 months –12, –25 RT-1011 Good fluid-resistant epoxy used with System 25.
*Shelf life from date of manufacture.