CUSTOMER DRAWING Product Revision Product Name B-023-00-55-22-9 A B-023-07-55-22-9 A oB min Product Dimensions oC min L max oD max 4.30 [0.169] 3.10 [0.122] 5.60 [0.220] 4.50 [0.177] 31.00 [ 1.220] 29.00 [1.142] 4.30 [0.169] 3.10 [0.122] Cable Dimensions oE J 0.50 min [J 0.020] 3.00 5.00 [0.118] [ 0.197] 2.40 6.00 [0.094] [0.236] MATERIALS 1. INSULATION SLEEVE: Heat-shrinkable, transparent clear, modified polytetrafluorethylene. 2. SOLDER PREFORM WITH FLUX: SOLDER: TYPE Pb93 per ANSI/J-STD-006. FLUX: TYPE ROM1 per ANSI/J-STD-004. 3. MELTABLE SEALING RINGS: Modified fluorinated ethylene propylene. 4. GROUND LEAD: Tyco Electronics/Raychem 55PC0813-22-9, nickel-plated copper, AWG 22, Color - white. APPLICATION 1. These controlled soldering devices are designed for termination of a nickel-plated copper shield of a cable having an insulation rated for at least 200C continuous. 2. Temperature range: -65C to +200C. 3. Install using Raychem-approved convection or infrared heating tools or equivalent. For best results, prepare the cable as shown: TITLE: Raychem Devices . Unless otherwise specified dimensions are in millimeters. [Inches dimensions are shown in brackets] TOLERANCES: 0.00 N/A 0.0 N/A 0 N/A ANGLES: N/A ROUGHNESS IN MICRON Tyco Electronics reserves the right to amend this drawing at any time. Users should evaluate the suitability of the product for their application. SOLDERSLEEVE DEVICE SHIELD TERMINATION WITH PRE-INSTALLED LEAD HIGH TEMPERATURE DOCUMENT NO.: B-023-XX-55-22-9 PROD. REV.: SEE TABLE PREPARED BY: REVISED PER: CAGE CODE : mforonda ECO-14-007657 06090 (c)2014 Tyco Electronics Corporation All rights reserved. If this document is printed it becomes uncontrolled. Check for the latest revision. DOC. ISSUE: DATE: B SCALE: None 21-May-14 SIZE: A SHEET: 1 of 1