0.65 23.0 57.3 33 2.04 4600 109L0612S402
0.53
0.44
0.36
18.7
15.5
12.7
40.2
29.4
19.6
12
12
12
12
0.23
0.16
0.12
0.08
28 1.32 3800 109L0612H402
24 1.08 3200 109L0612F402
20 0.72 2600 109L0612M402
0.65 23.0
18.7
15.5
12.7
27.6
57.3 24 0.23
40.2
29.4
19.6
87.2
0.16
0.12
0.08
0.35
33 1.92 4600 109L0624S402
60 x 60 x 25mm
m /min CFM Pa inch/H 0 V V dB(A) W min
32-1
43 LONG LIFE FANS
Click on Model No in red to view air performance curves
All Rights Reserved Sept 2001
Static Static Nominal Voltage Sound Power Nominal
Pressure Pressure Voltage Range Pressure Input Speed
Airflow Airflow Model No.
0.53 28 1.44 3800 109L0624H402
0.44
0.36
0.78
24
24
24
48
24 1.20 3200 109L0624F402
20 0.96 2600 109L0624M402
39 3.36 5600 109L0648G401*
Models without sensor
Models with sensor
Click to view dimensional drawings
10.2 - 13.8
10.2 - 13.8
10.2 - 13.8
10.2 - 13.8
20.4 - 27.6
20.4 - 27.6
20.4 - 27.6
20.4 - 27.6
40.8 - 55.2
18.7 40.2 0.16
0.53 48 28 1.92 3800 109L0648H402 40.8 - 53.0
Long Life Fan
Brushless DC Motor with Aluminium Fan Housing and Plastic Impeller
Expected Service Life of 100,000 hours (120mm fans = 200,000 hours)
(90% survival rate at 60 ºC, nominal voltage, continuous operation with
unobstructed inlets and outlets )
Permanently Lubricated Dual Ball Bearing System
Current Limiting System with Reverse Polarity Protection
Color-coded 300mm AWG 24 Leads (stripped and thinned ends)
Dual Speed Models Available
Operating Temperature: -10 ºC to +60 ºC (No Condensation)
Storage Temperature: -30 ºC to +70 ºC (No Condensation)
Dielectric Strength: 50/60 Hz, 500 VAC, one (1) minute
(between lead conductor and frame)
Mass: 100g to 780g
Rotational Direction: CW looking at label (Ø172mm fan = CCW)
Pulse/Lock/Inverse Lock/Low Speed/Inverse Low Speed Sensor Options
LONG LIFE FAN continued on next page