Table of Contents Low Voltage Switch Gear Selection Guide H-2 J7KNA-AR Mini Contactor Relays 4-pole H-7 J7KNA Mini Motor Contactor H-15 J7KN Motor Contactor H-27 J7TKN Thermal Overload Relay H-57 J7MN Motor Protection Circuit Breaker (MPCB) H-69 H-83 LVSG Appendix H-1 Selection Guide Low Voltage Switch Gear Classification Model Mini Contactor Relays Mini Motor Contactors J7KNA - AR J7KNA J7KNA-4 4-pole 3-pole 4-pole Remarks AC and DC operated 4-, 6- and 8-contacts in different configurations Positively guided contacts Screw fixing and snap fitting (DIN rail) AC and DC operated 3 main poles 1 auxiliary contact integrated (1NO or 1NC) AC operated 4 main poles Accessoirs Auxiliar contact modules Auxiliar contact modules Suppressors Link module MPCB - contactor Auxiliar contact modules Suppressors Link module MPCB - contactor Maximum power (AC3-380/415V) No 4 kW; 5,5 kW 4 kW Rated current (AC3-380/415V) 10 A (I th2) 9/12 A 9A AC operated Yes Yes Yes DC operated Yes Yes No 4 - pole version Yes No Yes Auxiliary contacts included No 1NO or 1NC No Auxiliary contacts front mounting 1NO/1NC 0NO/2NC 2NO/2NC 4NO/0NC 1NO/1NC 0NO/2NC 2NO/2NC 1NO/1NC 0NO/2NC 2NO/2NC Auxiliary contacts side mounting No No No Mechanical life span (AC operated) 5 Mio. 5 Mio. 5 Mio. Mechanical life span (DC operated) 15 Mio. 15 Mio. 15 Mio. Setting range (in A) No No No Page No. H-7 H-15 H-15 Appearance H-2 J7KN 24..KN 40 J7KN 50..KN 74 J7KN 85..KN 110 3-pole 3-pole 3-pole 3-pole AC and DC operate 3 main poles 1 auxiliary contact integrated (1NO or 1NC) max 4 auxiliary contacts front mounted AC and DC operate 3 main poles max 4 auxiliary contacts front mounted 2 auxiliary contacts side mounted (1NO or 1NC) AC and DC operate 3 main poles max 4 auxiliary contacts front mounted 2 auxiliary contacts side mounted (1NO or 1NC) AC and DC operate 3 main poles 4 auxiliary contacts integrated (1NO/1NC) Auxiliar contact modules Mechanical interlock Suppressors Link module MPCB-contactor Pneumatic timers Auxiliar contact modules Mechanical interlock Suppressors Link module MPCB-contactor Pneumatic timers Auxiliar contact modules Mechanical interlock Suppressors Pneumatic timers Mechanical interlock Suppressors 4 kW; 5,5 kW; 7,5 kW; 11 kW 11 kW; 15 kW; 18,5 kW 22 kW; 30kW; 37 kW 45 kW; 55 kW 10/14/18/22 A 24/32/40 A 50/62/74 A 85/110 A Yes Yes Yes Yes Yes Yes Yes Yes No No No No 1NO or 1NC No No 2NO + 2NC max 4 NO/NC max 4 NO/NC max 4 NO/NC No No 1NO + 1NC 1NO + 1NC 1NO + 1NC 10 Mio. 10 Mio. 10 Mio. 5 Mio. 10 Mio. 10 Mio. 10 Mio. 5 Mio. No No No No H-27 H-27 H-27 H-27 LVSG Motor Contactors J7KN 10..KN 22 H-3 Selection Guide Low Voltage Switch Gear Classification Model Motor Contactors Thermal Overload Relays J7KN 150..KN 175 J7KN 200 J7TKN-A 3-pole 3-pole Remarks AC and DC operate 3 main poles 2 auxiliary contacts integrated (1NO/ 1NC) AC and DC operate 3 main poles 4 auxiliary contacts integrated (1NO/ 1NC) Direct mounting 1 auxiliary contact (change over) Accessoirs No No No Maximum power (AC3-380/415V) 75 kW; 90 kW 110 kW Rated current (AC3-380/415V) 150/175 A 210 A AC operated Yes Yes DC operated No No 4 - pole version No No Auxiliary contacts included 1NO + 1NC 2NO + 2NC Auxiliary contacts front mounting No No Appearance 1NO + 1NC Auxiliary contacts side mounting 1NO + 1NC 2NO + 2NC Mechanical life span (AC operated) 10 Mio. 10 Mio. Mechanical life span (DC operated) 10 Mio. 10 Mio. Setting range (in A) No No 0,12..30 A Page No. H-27 H-27 H-57 H-4 Motor Protection Circuit Breakers (MPCB) J7TKN-E..TKN-F J7MN12 J7MN25 Direct mounting Auto, -manual, -reset button 2 auxiliary contacts (1NO/1NC) Separate mounting 2 auxiliary contacts (1NO/1NC) Rocker operating switch Short circuit release Over load release I cu = 100 kA (0,16..6,3 A) Rotary operating switch Short circuit release Over load release I cu = 100 kA (0,16..12,5 A) Sets for single mounting Busbar sets Sets for single mounting Busbar sets Trip indicating contact Plastic enclosures 2 contacts side mounted 2 contacts front mounted Bus bar system Trip indicating contact Plastic enclosures 3 contacts side mounted 2 contacts front mounted Bus bar system 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 100000 100000 0,12..74 A 60..220 A 0,11..12 A 0,11..25 A H-57 H-57 H-69 H-69 LVSG Thermal Overload Relays J7TKN-B..TKN-D H-5 Selection Guide Low Voltage Switch Gear Classification Model Motor Protection Circuit Breakers (MPCB) J7MN50 J7MN100 Remarks Rotary operating switch Short circuit release Over load release I cu = 50 kA Rotary operating switch Short circuit release Over load release I cu = 50 kA Accessoirs Trip indicating contact Plastic enclosures 2 contacts side mounted 3 contacts front mounted Bus bar system Trip indicating contact Plastic enclosures 2 contacts side mounted 3 contacts front mounted Bus bar system 1NO + 1NC 1NO + 1NC Auxiliary contacts side mounting 1NO + 1NC 1NO + 1NC Mechanical life span (AC operated) 50000 50000 Setting range (in A) 22..50 A 45..100 A Page No. H-69 H-69 Appearance Maximum power (AC3-380/415V) Rated current (AC3-380/415V) AC operated DC operated 4 - pole version Auxiliary contacts included Auxiliary contacts front mounting Mechanical life span (DC operated) H-6 Mini Contactor Relays 4-pole J7KNA-AR ) Main contactor * AC & DC operated * 4-, 6- and 8-pole versions in different configurations * Positively guided contacts * Screw fixing and snap fitting (35 mm DIN rail) * Rated current = 10A (Ith) * Suitable for electronic devices (DIN 19240) * Finger proof (VBG 4) Accessories * 2- and 4-pole additional auxiliary contacts in different configurations Approved Standards Standard Guide No (US,C) UL NKCR, NKCR7 ICE 947-5-1 VDE 0660 EN 60947-5-1 LVSG Ordering Information Model Number Legend 1. Mini Contactor Relays 7KNA-##-##-##### 1 2 3 4 1) 2) 3) 4) Mini Contactor AR: Contactor Relay Combination of NO / NC contacts 22: 2 NO 2 NC 31: 3 NO 1NC 40: 4 NO 0NC Coil voltage (AC operated) 24: AC24V 50/60Hz 48: AC48V 50Hz 110: AC110-115V 50Hz,AC120-125V 60Hz 230: AC220-230V 50Hz,AC240V 60Hz 240: AC230V-240V 50Hz 400: AC380-400V 50Hz,AC440V 60Hz 415: AC400-415V 50Hz 550: AC525-550V 50Hz,AC600V 60Hz Coil voltage (DC operated) 24D: DC24V 48D: DC48V 60D: DC60V 110D: DC110V 125D: DC125V 24VS: DC24V with diode 48VS: DC48V with diode 110VS: DC110V with diode 2. Aux. Contact Modules for Mini Contactor Relays 73KN-##-##-# 1 2 3 4 1) 2) 3) Auxiliary Contact Modules A: for mini contactor relay Combination of NO/NC contacts 11: 1 NO 1 NC 02: 0 NO 2 NC 22: 2 NO 2 NC 40: 4 NO 0 NC Mini Contactor Relays 4-pole J7KNA-AR H-7 System overview Mini Contactor Relays 4-pole AC Operated Contacts NO NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type 400V A Thermal Rated Current Ith A 2 10 J7KNA-AR-40 24 24 230 Coil voltage 1) 24V 50/60Hz 220-230V 50Hz Pack Weight pcs. kg/pc. 10 0,16 10 0,16 10 0,16 4-pole, With Screw Terminals 4 - 40E 3 J7KNA-AR-40 230 3 1 31E 3 2 10 J7KNA-AR-31 24 J7KNA-AR-31 230 2 2 22E 3 2 10 J7KNA-AR-22 24 J7KNA-AR-22 230 1) Other coil voltages see page 10 DC Solenoid Operated Contacts NO NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type Pack Weight 400V A Thermal Rated Current Ith A Coil voltage 24V DC 2,5W pcs. kg/pc. 4-pole, With Screw Terminals 4 - 40E 3 2 10 J7KNA-AR-40 24D (-VS)1) 10 0,19 3 1 31E 3 2 10 J7KNA-AR-31 24D (-VS)1) 10 0,19 2 2 22E 3 2 10 J7KNA-AR-22 24D (-VS)1) 10 0,19 Type Pack Weight pcs. kg/pc. J73KN-A-11 10 0,04 0,04 1) VS = with diode Auxiliary Contact Blocks for Contactor Relays J7KNA-AR H-8 Contacts Ratings NO NC AC15 230V A 400V A Thermal Rated Current Ith A 1 1 3 2 10 - 2 3 2 10 J73KN-A-02 10 4 - 3 2 10 J73KN-A-40 10 0,04 2 2 3 2 10 J73KN-A-22 10 0,04 Mini Contactor Relays 4-pole J7KNA-AR System overview Mini Contactor Relays 4-pole AC Operated Wiring Diagrams Distinc. Number acc. to DIN EN 50011 Auxiliary Contact Blocks Type NO NC Contactor Relay with Auxiliary Contact Contacts suitable for Electronic Block Circuits according to DIN 19240 Distinc. Number for rated voltage 24V DC according to (test ratings 17V DC, 5mA) DIN EN 50011 NO NC Positively guided contacts J73KN-A-11 1 1 51E 5 1 J73KN-A-02 0 2 42E 4 2 J73KN-A-40 4 0 80E 8 0 J73KN-A-22 2 2 62E 6 2 J73KN-A-11 1 1 42Y 4 2 J73KN-A-02 0 2 33Y 3 3 J73KN-A-40 4 0 71Y 7 1 J73KN-A-22 2 2 53Y 5 3 J73KN-A-11 1 1 33Y 3 3 J73KN-A-02 0 2 24Y 2 4 J73KN-A-40 4 0 62Y 6 2 J73KN-A-22 2 2 44Y 4 4 4-pole, With Screw Terminals 40E 31E 22E Preferable combinations with distinctive letter E" according to DIN EN 50011 DC Solenoid Operated Wiring Diagrams Distinc. Number acc. to DIN EN 50011 Auxiliary Contact Blocks Contactor Relay with Auxiliary Contact Type NO NC Block Distinc. Number according to DIN EN 50011 J73KN-A-11 1 1 51E 5 1 J73KN-A-02 0 2 42E 4 2 J73KN-A-40 4 0 80E 8 0 J73KN-A-22 2 2 62E 6 2 J73KN-A-11 1 1 42Y 4 2 J73KN-A-02 0 2 33Y 3 3 J73KN-A-40 4 0 71Y 7 1 J73KN-A-22 2 2 53Y 5 3 J73KN-A-11 1 1 33Y 3 3 J73KN-A-02 0 2 24Y 2 4 J73KN-A-40 4 0 62Y 6 2 J73KN-A-22 2 2 44Y 4 4 NO NC 40E 31E 22E Preferable combinations with distinctive letter E" according to DIN EN 50011 Auxiliary Contact Blocks for Contactor Relays J7KNA-AR Wiring diagrams J73KN-A-11 J73KN-A-02 J73KN-A-40 J73KN-A-22 Mini Contactor Relays 4-pole Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts J7KNA-AR H-9 LVSG 4-pole, With Screw Terminals Specifications Coil Voltages Voltage Marking Rated Control Voltage Us Suffix Voltage Marking Rated Control Voltage Us to contactor type e.g. at the coil range for 50Hz to contactor type e.g. at the coil range for 50Hz J7KNA-09-10-24 for 50Hz for 60Hz min V V V. max V. min V. max V. for 50Hz for 60Hz min V V. J7KNA-09-10- 230 V max V. min V. max V. 12 12 12 11 12 12 12 210 205-215 220-230 205 215 220 230 24 24 24 22 24 24 24 220 210-220 230-240 210 220 230 240 42 42 42 38.5 42 42 42 230 220-230 240 220 230 240 250 48 48-50 48 48 50 48 50 240 230-240 230 240 250 260 60 60 60 52 66 54 60 400 380-400 440 380 400 415 440 90 90-95 100-105 90 95 100 105 500 475-500 520-545 475 500 520 545 95 95-100 105-110 95 100 105 110 550 525-550 600 550 570 600 100 100 110-115 100 105 110 115 105 105-110 115-120 105 110 115 120 110 110-115 120-125 110 115 120 125 200 200 205 210 220 Suffix H-10 210-220 195 60Hz Mini Contactor Relays 4-pole J7KNA-AR 525 60Hz Standard voltages in bold type letters. Coil not exchangeable Engineering data and Characteristics Mini Contactor Relays Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 Auxiliary Contacts Type J7KNA-AR... J7KNA-AR...D J7KNA-AR...VS J73KN-A... Rated insulation voltage Ui V AC 690*1 690*1 690*1 690*1 40C A 10 10 10 10 60C A 6 6 6 6 at Ith W 0.5 0.5 0.5 0.5 220-240V A 3 3 3 3 380-415V A 2 2 2 2 440V A 1.6 1.6 1.6 1.6 Thermal rated current Ith to 690V Ambient temperature Power loss per pole Utilization category AC15 Rated operational current Ie 500V A 1.2 1.2 1.2 1.2 660-690V A 0.6 0.6 0.6 0.6 Utilization category DC13 Rated operational current Ie 60V A 2 2 2 2 110V A 0.4 0.4 0.4 0.4 220V A 0.1 0.1 0.1 0.1 open C -40 to +60 (+90)*2 enclosed C -40 to +40 C -40 to +90 Maximum ambient temperature Operation Storage max. fuse size gL (gG) A 20 20 20 20 inrush VA 25 - - - sealed VA 4-5 - - - W 1.2 - - - inrush W - 2.5 2.5 - sealed W - 2.5 2.5 - 0.85 - 1.1 0.8 - 1.1 0.8 - 1.1 - - LVSG Short circuit protection short-circuit current 1kA, contact welding not accepted Power consumption of coils AC operated DC operated Operation range of coils in multiples of control voltage Us Switching time at control voltage U 10% *3,*4 s AC operated DC operated make time ms 15 - 25 - - release time ms 8 - 25 - - - arc duration ms 10 -15 - - - make time ms - 15 - 19 - - release time ms - 8 - 25 - - arc duration ms - 10 -15 - - Mini Contactor Relays 4-pole J7KNA-AR H-11 Mini Contactor Relays Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 Type J7KNA-AR... J7KNA-AR...D J7KNA-AR...VS J73KN-A... solid mm 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 flexible mm 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 mm 0.5 - 1.5 0.5 - 1.5 0.5 - 1.5 0.5 - 2.5 2 2 2 18 - 14 18 - 14 18 - 14 Auxiliary Contacts Cable cross-section all connectors flexible with multicore cable end Clamps per pole 2 solid or stranded AWG 18 - 14 *1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x Us and with reduced thermal rated current Ith to Ie/AC15 *3) Summary switching time = release time + arc duration *4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units). Mini Contactor Relays for North America Data according to UL508 Main Contacts (cULus) Type J7KNA-AR... J73KN-A... Rated operational current "General Use" A 10 10 - Rated operational power of three-phase motors 115V hp - at 60Hz (3ph) 200V hp - - 230V hp - - 460V hp - - 575V hp - - Rated operational power of of AC motors 115V hp - - at 60Hz (1ph) 200V hp - - 230V hp - - Fuses Suitable for use on a capability of delivering not more than rms Rated voltage - - - - V - - V AC 600 Auxiliary Contacts (cULus) H-12 A A 600 heavy pilot duty AC A600 A600 standard pilot duty DC Q600 Q600 Mini Contactor Relays 4-pole J7KNA-AR Dimensions Auxiliary Contact Blocks J7KNA-AR... J73KN-A... LVSG AC and DC operated with screw terminals Mini Contactor Relays 4-pole J7KNA-AR H-13 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J507-E2-02 H-14 In the interest of product improvement, specifications are subject to change without notice. Mini Contactor Relays 4-pole J7KNA-AR Mini Motor Contactor J7KNA ) Main contactor * AC & DC operated * Integrated auxiliary contacts * Screw fixing and snap fitting (35 mm DIN rail) * Range from 4 to 5.5 kW (AC 3, 380/415V) * 4 -main pole version (4 kW AC and DC coil) * Auxiliary contacts suitable for electronic devices (DIN 19240) * Finger proof (VBG 4) Accessories * 2 and 4 pole additional auxiliary contacts in different configurations * Mechanical interlock (in reversing contactor combination only) * RC Suppressors Approved Standards Standard Guide No (US,C) UL NLDX, NLDX7 ICE 947-5-1 VDE 0660 LVSG EN 60947-5-1 Ordering Information Model Number Legend 400: 415: 1. Mini Motor Contactors Coil voltage (DC operated) 24D: DC24V 48D: DC48V 60D: DC60V 110D: DC110V 24VS: DC24V with diode 48VS: DC48V with diode 110VS: DC110V with diode J7KNA-##-##-#-##### 1 2 3 4 5 1) 2) 3) 4) 5) Mini Contactor Rated Motor Current (AC3 400V) 09: 9A 12: 12A Integrated auxiliary contact 10: 1 NO 0 NC 01: 0 NO 1 NC 4: 4 main pole type (no aux contact) W: Reversing Contactor Coil voltage (AC operated)1) 24: AC24V 50/60Hz 48: AC48V 50Hz 60: AC60V 50Hz 110: AC110-115V 50Hz, AC120-125V 60Hz 230: AC220-230V 50Hz, AC240V 60Hz 240: AC230V-240V 50Hz 2. Aux. Contact Modules for Mini Motor Contactors J73KN-##-##-# 1 2 3 4 1) 2) 3) 4) 1) RC-suppressor unit go to page H-29, section 6 or page H-35, suppressor units AC380-400V 50Hz, AC440V 60Hz AC400-415V 50Hz Auxiliary Contact Modules AM: for mini motor contactor Combination of NO/NC contacts 11: 1 NO 1 NC 02: 0 NO 2 NC 22: 2 NO 2 NC 40: 4 NO 0 NC for Reversing Contactors v: left side x: right side Mini Motor Contactor J7KNA H-15 System overview Mini Motor Contactors AC Operated Ratings Rated Current Aux. Contacts AC2, AC3 AC3 380V 400V 415V kW 500V kW 660V 690V kW 400V A Type Pack Weight pcs. kg/pc. AC1 690V A NO NC Accept Overlod Relay see 24 page H-58 230 Coil Voltage*1 24V 50/60Hz 220-230V 50Hz 3-pole, With Screw Terminals 4 4 4 9 20 1 - J7TKN-A J7KNA-09-10-# # # # # 10 0.16 5.5 5.5 5.5 12 20 1 - J7TKN-A J7KNA-12-10-# # # # # 10 0.16 4 4 4 9 20 - 1 J7TKN-A J7KNA-09-01-# # # # # 10 0.16 5.5 5.5 5.5 12 20 - 1 J7TKN-A J7KNA-12-01-# # # # # 10 0.16 - - J7TKN-A J7KNA-09-4-# # # # # 10 0.19 Pack Weight pcs. kg/pc. 4-pole, With Screw Terminals 4 4 4 9 20 *1) Other coil voltages see page H-20 DC Solenoid Operated Ratings Rated Current Aux. Contacts AC2, AC3 AC3 380V 400V 415V kW 500V kW 660V 690V kW 400V A Type AC1 690V A NO NC Accept Overlod Relay see 24D page H-58 24VS DC Coil Voltage 24V 50/60Hz 24V 50/60Hz w. diode*1 3-pole, With Screw Terminals 4 4 4 9 20 1 - J7TKN-A J7KNA-09-10-# # # D(-VS) 10 0.19 5.5 5.5 5.5 12 20 1 - J7TKN-A J7KNA-12-10-# # # D(-VS) 10 0.19 4 4 4 9 20 - 1 J7TKN-A J7KNA-09-01-# # # D(-VS) 10 0.19 5.5 5.5 5.5 12 20 - 1 J7TKN-A J7KNA-12-01-# # # D(-VS) 10 0.19 *1) with built-in coil suppressor (zener diode) Auxiliary contact blocks with screw terminals for contactors J7KNA-09... and J7KNA-12... H-16 Contacts Rated Current Thermal Rated Current Type Pack Weight NO NC AC15 230V 400V A A A pcs. kg/pc. 1 1 3 2 10 J73KN-AM-11 10 0.04 - 2 3 2 10 J73KN-AM-02 10 0.04 2 2 3 2 10 J73KN-AM-22 10 0.04 Mini Motor Contactor J7KNA System overview Mini Motor Contactors AC Operated Auxiliary Contact Blocks Wiring Diagrams Contactor with Auxiliary Contact Block Distinc. Number according to DIN EN 50012 Type NO NC Distinc. Number according to DIN EN 50012 NO J73KN-AM-11 1 1 21 2 1 J73KN-AM-02 0 2 12 1 2 NC Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts 3-pole, With Screw Terminals 10 01 J73KN-AM-22 2 2 32 3 2 J73KN-A-11 1 1 - 1 2 J73KN-A-02 0 2 - 0 3 J73KN-A-40 4 0 - 4 1 J73KN-A-22 2 2 - 2 3 J73KN-A-11 1 1 - 1 1 J73KN-A-02 0 2 - 0 2 J73KN-A-40 4 0 - 4 0 J73KN-A-22 2 2 - 2 2 Prefered combinations according to DIN EN 50012 Contacts according to DIN EN 50005 4-pole, With Screw Terminals 1 3 5 7 A1 00 A2 2 4 6 8 Contacts according to DIN EN 50005 DC Solenoid Operated Contactor with Auxiliary Contact Block Distinc. Number according to DIN EN 50012 Type NO NC Distinc. Number according to DIN EN 50012 NO J73KN-AM-11 1 1 21 2 1 J73KN-AM-02 0 2 12 1 2 NC Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts 3-pole, With Screw Terminals 10 01 J73KN-AM-22 2 2 32 3 2 J73KN-A-11 1 1 - 1 2 J73KN-A-02 0 2 - 0 3 J73KN-A-40 4 0 - 4 1 J73KN-A-22 2 2 - 2 3 Prefered combinations according to DIN EN 50012 Contacts according to DIN EN 50005 Auxiliary contact blocks with screw terminals for contactors J7KNA-09... and J7KNA-12... Wiring Diagrams J73KN-AM-11 J73KN-AM-02 J73KN-AM-22 J73KN-A-11 J73KN-A-02 J73KN-A-40 J73KN-A-22 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts Mini Motor Contactor J7KNA H-17 LVSG Auxiliary Contact Blocks Wiring Diagrams System overview Mini Reversing Contactors, Mechanical Interlocked AC Operated Ratings Rated Current Aux. Contacts AC2, AC3 AC3 380V 400V 415V kW 500V kW 660V 690V kW 400V A Type Pack Weight pcs. kg/pc. AC1 690V A NO NC Accept Overlod Relay see 24 page H-58 230 Coil Voltage*1 24V 50/60Hz 220-230V 50Hz 3-pole, With Screw Terminals 4 4 4 9 20 - 1 J7TKN-A J7KNA-09-01-W-# # # # # 1 0.32 5.5 5.5 5.5 12 20 - 1 J7TKN-A J7KNA-12-01-W-# # # # # 1 0.32 Pack Weight pcs. kg/pc. *1) Other coil voltages see page H-20 DC Solenoid Operated Ratings Rated Current Aux. Contacts AC2, AC3 AC3 380V 400V 415V kW 500V kW 660V 690V kW 400V A Type AC1 690V A NO NC Accept Overlod Relay see 24D page H-58 24VS DC Coil Voltage 24V 50/60Hz 24V 50/60Hz w. diode*1 3-pole, With Screw Terminals 4 4 4 9 20 - 1 J7TKN-A J7KNA-09-01-W-# # # D 1 0.38 5.5 5.5 5.5 12 20 - 1 J7TKN-A J7KNA-12-01-W-# # # D 1 0.38 *1) with built-in coil suppressor (zener diode) Auxiliary contact blocks with screw terminals for contactors J7KNA-09-01-W...(D) and J7KNA-12-01-W...(D) H-18 Contacts Rated Current Thermal Rated Current Type Pack Weight NO NC AC15 230V 400V A A A pcs. kg/pc. 1 1 3 2 10 J73KN-AM-11V 10 0.04 1 1 3 2 10 J73KN-AM-11X 10 0.04 Mini Motor Contactor J7KNA System overview Mini Motor Contactors AC Operated Auxiliary Contact Blocks suitable for Wiring Diagrams left hand side right hand side Contactor K1 Contactor K2 Distinc. Number according to DIN EN 50012 Type NO NC Type Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) NO NC Positively guided contacts 1 1 3-pole, With Screw Terminals J73KN-AM-11V 1 J73KN-AM-11X 1 01 DC Solenoid Operated Auxiliary Contact Blocks suitable for Wiring Diagrams left hand side right hand side Contactor K1 Contactor K2 Distinc. Number according to DIN EN 50012 Type NO NC Type Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) NO NC Positively guided contacts 1 1 3-pole, With Screw Terminals J73KN-AM-11V 1 J73KN-AM-11X 1 LVSG 01 Auxiliary contact blocks with screw terminals for contactors J7KNA-09-01-W...(D) and J7KNA-12-01-W...(D) Wiring Diagrams J73KN-AM-11V J73KN-AM-11X 13 31 31 13 14 32 32 14 Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts Mini Motor Contactor J7KNA H-19 Specifications Coil Voltages Voltage Marking Rated Control Voltage Us Suffix Voltage Marking Rated Control Voltage Us to contactor type e.g. at the coil range for 50Hz to contactor type e.g. at the coil range for 50Hz J7KNA-09-10-24 for 50Hz for 60Hz min V V V. max V. min V. max V. J7KNA-09-10 -230 for 50Hz for 60Hz min V V V. max V. min V. max V. 12 12 12 11 12 12 12 210 205-215 220-230 205 215 220 230 24 24 24 22 24 24 24 220 210-220 230-240 210 220 230 240 48 48-50 48 48 50 48 50 230 220-230 240 220 230 240 250 60 60 60 52 66 54 60 240 230-240 230 240 250 260 90 90-95 100-105 90 95 100 105 400 380-400 440 380 400 415 440 95 95-100 105-110 95 100 105 110 500 475-500 520-545 475 500 520 545 100 100 110-115 100 105 110 115 550 525-550 600 550 570 600 105 105-110 115-120 105 110 115 120 110 110-115 120-125 110 115 120 125 200 200 205 210 220 Suffix H-20 210-220 195 Mini Motor Contactor J7KNA 60Hz 525 60Hz Standard voltages in bold type letters. Coil not exchangeable Engineering data and Characteristics Mini Motor Contactors Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type J7KNA-09-... J7KNA-12-... Rated insulation voltage Ui V AC 690*1) 690 '1) at Ue = 690V AC A 165 165 Breaking capacity Ieff 400V AC A 100 100 cos = 0,65 500V AC A 90 90 690V AC A 80 80 A 20 20 Making capacity Ieff Utilization category AC1 Switching of resistive load Rated operational current Ie (=Ith) at 40C, open Rated operational power of three-phase resistive loads 230V kW 7.9 7.9 50-60Hz, cos = 1 240V kW 8.3 8.3 400V kW 13.8 13.8 415V kW 14.3 14.3 A 16 16 Rated operational current Ie (=Ithe) at 60C, enclosed Rated operational power of three-phase resistive loads 230V kW 6.3 6.3 50-60Hz, cos = 1 240V kW 6.7 6.7 400V kW 11 11 415V kW 11.5 11.5 Minimum cross-section of conductor at load with Ie (=Ith) mm 2.5 2.5 Utilization category AC2 and AC3 Rated operational current Ie 220V A 12 15 open and enclosed 230V A 11.5 14.5 240V A 11 14 380-400V A 9 12 415-440V A 8 11 500V A 7 9 660-690V A 5 6.5 Rated operational power of three-phase motors 220-240V kW 3 4 50-60Hz 380-440V kW 4 5.5 500-690V kW 4 5.5 LVSG Switching of three-phase motors Utilization category AC4 Switching of squirrel cage motors, inching Rated operational current Ie 220V A 12 15 open and enclosed 230V A 11.5 14.5 240V A 11 14 380-400V A 9 12 415-440V A 8 11 500V A 7 9 660-690V A 5 6.5 Rated operational power of three-phase motors 220-240V kW 3 4 50-60Hz 380-440V kW 4 5.5 500-690V kW 4 5.5 Mini Motor Contactor J7KNA H-21 Mini Motor Contactors Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1 Type J7KNA-09-... J7KNA-12-... 1 pole 24V A 20 20 60V A 20 20 110V A 5 5 220V A 0.6 0.6 3 poles in series 24V A 20 20 60V A 20 20 110V A 20 20 220V A 16 16 1 pole 24V A 20 20 60V A 5 5 Time constant L/R 15ms 110V A 1 1 Rated operational current Ie 220V A 0.15 0.15 3 poles in series 24V A 20 20 60V A 20 20 110V A 20 20 220V A 2 2 open C Main Contacts Utilization category DC1 Switching of resistive load Time constant L/R 1ms Rated operational current Ie Utilization category DC3 and DC5 Switching of shunt motors and series motors Maximum ambient temperature Operation -40 to +60 (+90)*2 enclosed C -40 to +40 open C -25 to +60 with thermal overload relay enclosed Storage C -25 to +40 C -50 to +90 Short circuit protection for contactors without thermal overload relay Coordination-type "1" according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size gL (gG) A 40 40 Coordination-type "2" according to IEC 947-4-1 Light contact welding accepted max. fuse size gL (gG) A 25 25 Contact welding not accepted max. fuse size gL (gG) A 10 10 For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable cross-sections for contactors without thermal overload relay main connector solid or stranded mm 0.5 - 2.5 0.5 - 2.5 flexible mm 0.5 - 2.5 0.5 - 2.5 flexible with multicore cable end mm 0.5 - 1.5 0.5 - 1.5 Cables per clamp 2 solid or stranded H-22 Mini Motor Contactor J7KNA AWG 18 - 14 2 18 - 14 Mini Motor Contactors Data according to IEC 947-4-1, VDE 0660, EN 60947-4-1 Type J7KNA-09-... Main Contacts Frequency of operations z J7KNA-12-... without load 1/h 10000 10000 AC3, Ie 1/h 600 700 Contactors without thermal overload relay AC4, Ie 1/h 120 150 DC3, Ie 1/h 600 700 Mechanical life AC operated Sx 6 10 5 5 DC operated Sx 106 15 15 10s-current A 96 120 at Ie/AC3 400V W 0.15 0.25 NO g 5 5 NC g 5 5 NO g 8 8 NC g 6 6 Short time current Power loss per pole Resistance to shock according to IEC 68-2-27 Shock time 20ms sine-wave AC operated DC operated LVSG *1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x Us and with reduced rated current Ie/AC1according to Ie/AC3 Mini Motor Contactor J7KNA H-23 Mini Motor Contactors Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 Auxiliary Contacts J7KNA-09... Type J7KNA-12... J7KNA-09...D(VS) J7KNA-12...D(VS) J73KN-A... Rated insulation voltage Ui V AC 690*1 690*1 690*1 Thermal rated current Ith to 690V Ambient temperature 40C A 10 10 10 60C A 6 6 6 at Ith W 0.5 0.5 0.5 220-240V A 3 3 3 380-415V A 2 2 2 440V A 1.6 1.6 1.6 Power loss per pole Utilization category AC15 Rated operational current Ie 500V A 1.2 1.2 1.2 660-690V A 0.6 0.6 0.6 Utilization category DC13 Rated operational current Ie 60V A 2 2 2 110V A 0.4 0.4 0.4 220V A 0.1 0.1 0.1 open C Maximum ambient temperature Operation enclosed Storage -40 to +60 (+90)*2 C -40 to +40 C -40 to +90 Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size gL (gG) A 20 20 20 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size. Power consumption of coils AC operated DC operated inrush VA 25 - - sealed VA 4-5 - - W 1.2 - - inrush W - 2.5 - sealed W - 2.5 - 0.85 - 1.1 0.8 - 1.1 19 - 30V DC Operation range of coils in multiples of control voltage Us - *3,*4 Switching time at control voltage U 10% s AC operated DC operated H-24 make time ms 15 - 25 - - release time ms 8 - 25 - - arc duration ms 10 -15 - - make time ms - 15 - 19 - release time ms - 8 - 25 - arc duration ms - 10 -15 - Mini Motor Contactor J7KNA Mini Motor Contactors Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 J7KNA-09... Type J7KNA-12... J7KNA-09...D(VS) J7KNA-12...D(VS) J73KN-A... solid mm 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 flexible mm 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 mm 0.5 - 1.5 0.5 - 1.5 0.5 - 2.5 2 2 18 - 14 18 - 14 Auxiliary Contacts Cable cross-section all connectors flexible with multicore cable end Clamps per pole 2 solid or stranded AWG 18 - 14 *1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x Us and with reduced thermal rated current Ith to Ie/AC15 *3) Summary switching time = release time + arc duration *4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units). Mini Contactors for North America Main Contacts (cULus) Type J7KNA-09... J7KNA-12... J73KN-A... Rated operational current "General Use" A 20 10 15 Rated operational power of three-phase motors 115V hp 11/2 2 - at 60Hz (3ph) 200V hp 3 3 - 230V hp 3 3 - 460V hp 5 71/2 - 575V hp 71/2 10 - Rated operational power of of AC motors 115V hp 1/2 3/4 - at 60Hz (1ph) 200V hp 1 11/2 - 230V hp 11/2 2 - Fuses A 30 30 - A 5000 5000 - V 600 600 - V AC 600 600 600 heavy pilot duty AC A600 A600 A600 standard pilot duty DC Q600 Q600 Q600 Suitable for use on a capability of delivering not more than rms Rated voltage Auxiliary Contacts (cULus) Mini Motor Contactor J7KNA LVSG Data according to UL508 H-25 Dimensions AC and DC operated with screw terminals Auxiliary Contact Blocks J7KNA-09... J7KNA-12... J73KN-A... Reversing Contactors J7KNA-09-01-W... J7KNA-12-01-W... J7KNA-09-01-W... + J7TKN-A J7KNA-12-01-W...+ J7TKN-A ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J506-E2-02 H-26 In the interest of product improvement, specifications are subject to change without notice. Mini Motor Contactor J7KNA Motor Contactor J7KN Main contactor * AC & DC operated * Integrated auxiliary contacts * Screw fixing and snap fitting (35 mm DIN rail) up to 45 kW * Range from 4 to 110 kW (AC 3, 380/415V) * Finger proof (VBG 4) Accessories * front mounted single pole additional auxiliary contacts (1 NO or 1 NC) * Side mounted additional auxiliary contacts (1 NO/1 NC) * Mechanical interlock * Suppressors (RC and varistor) * Pneumatic timer modules * Link modules MPCB - Motor contactor Approved Standards Standard Guide No (US,C) UL NLDX, NLDX7 ICE 947-4-1 VDE 0660 LVSG EN 60947-4-1 Motor Contactor J7KN H-27 H-28 Motor Contactor J7KN Ordering Information Model Number Legend J7KN-###-##-#### 1 2 3 4 1) 2) 3) 4) Motor Contactor Rated Motor Current (AC3 400V) 10: 10A 14: 14A 18: 18A 22: 22A 24: 24A 32: 32A 40: 40A 50: 50A 62: 62A 74: 74A 85: 85A 110: 110A 150: 150A 175: 175A 200: 200A Integrated auxiliary contact 10: 1NO 0NC 01: 0NO 1NC 21: 2NO 1NC 22: 2NO 2NC : 0NO 0NC Coil voltage (AC operated) 24: AC24V 50/60Hz 48: AC48V 50Hz 110: AC110V 50Hz, AC110-120V 60Hz 180: AC180-210V 50Hz, AC200-240V 60Hz 230: AC220-240V 50Hz, AC240V 60Hz 400: AC380-415V 50Hz, AC415-440V 60Hz 500: AC500-550V 50Hz, AC550-600V 60Hz Coil voltage(DC operated) 24D: DC24V 48D: DC48V 110D: DC110V 125D: DC125V 4. Accessories for Motor Contactors (Pneumatic Timers) J74KN-#-## ### ## 1 2 3 4 5 1) 2) 3) 4) 5) 5. Accessories for Motor Contactors (Mechanical Interlock) J74KN-#-## 1 2 3 1) 2) 3) 1) 2) 3) 4) Auxiliary Contact Modules B: for motor contactor (4-37kW) C: for motor contactor (11-37kW) Combination of NO/NC contacts 10: 1NO 0NC 01: 0NO 1NC 11: 1NO 1NC S: side mounting : front mounting Accessories for Motor Contactors B: Motor Contactor (4-18.5kW) C: Motor Contactor (11-37kW) D: Motor Contactor (45-55kW) ML: Mechanical Interlock 6. Accessories for Motor Contactors (RC Suppressor units) J74KN-#-## ### 1 2 3 4 1) 2) 3) 4) 2. Aux. Contact Modules for Motor Contactors J73KN-#-##-# 1 2 3 4 Accessories for Motor Contactors B: Motor Contactor (4-11kW) TP: Pneumatic Timer 40: 40 sec 180: 180 sec DA: ON-delayed IA: OFF-delayed Accessories for Motor Contactors A: for Mini Motor Contactor and Motor Contactor (4-18.5kW) (between DIN-rail and Contactor) B: for Mini Motor Contactor and Motor Contactor (4-55kW) C: for Motor Contactor (4-37kW) to snap on the contactor RC: RC-surge suppressors 48: 24 - 48 VAC/DC (A+B type) 230: 110 - 230 VAC/DC (A+B type) 400: 250 - 415 VAC/DC (A+B type) 24: 12 - 48 VAC/DC (C type) 110: 48 - 127 VAC/DC (C type) 230: 110 - 250 VAC/DC (C type) 7. Accessories for Motor Contactors (Varistor units) J74KN-#-## ### 1 2 3 4 1) 2) 3) 4) Accessories for Motor Contactors A: for Motor Contactor (4-11kW) to snap on to coil terminals B: for Motor Contactor (4-37kW) to snap on to contactor VG: Varistor Suppressors 230: 110-230VAC/DC 400: 250-415VAC/DC 3. Accessories for Motor Contactors (Link Modules MPCB - Motor Contactor) J74KN-##-## 1 2 3 1) 2) 3) Accessories for Motor Contactors VD: Link module type HU: DIN-rail adapter type 12: for motor contactor (4 - 7.5kW) 25: for motor contactor (11 - 15kW) Motor Contactor J7KN H-29 LVSG 1. Motor Contactors List of Models Contactors 3-pole * * * * * Up to 210A AC3 Up to 350A AC1 DIN-rail mounting up to AC3 74A International Approvals Data according to IEC 947 / EN 60947 Ratings AC3 400V Motor 380-400V 660-690V 690V at 40C AC1 Type Auxiliary contacts Type Auxiliary contacts Cable cross-section Solid mm2 Flexible mm2 Cables per clamp Auxiliary contact Ith 40C A AC15 230V A 400V A Power consumption of coils Inrush VA Hold VA Operation range of coils Mounting Additional aux. contact blocks Front mounting Type contacts 10A 4kW 5,5kW 25A J7KN10-10 1NO J7KN10-01 1NC 14A 5,5kW 7,5kW 25A J7KN14-10 1NO J7KN14-01 1NC 18A 7,5kW 10kW 32A J7KN18-10 1NO J7KN18-01 1NC 22A 11kW 10kW 32A J7KN22-10 1NO J7KN22-01 1NC 24A 11kW 15kW 50A J7KN-24 32A 15kW 18,5kW 65A J7KN-32 40A 18,5kW 18,5kW 80A J7KN-40 50A 22kW 30kW 110A J7KN-50 62A 30kW 37kW 120A J7KN-62 74A 37kW 45kW 130A J7KN-74 - - - - - - - - - - - - 0,75 - 6 1-4 2 1,5 - 25 2,5 - 16 1+1 4 - 50 10 - 35 1+1 16 12 4 - - 33 - 45 7 - 10 0,85 - 1,1 35mm DIN-rail or base 90 - 115 9 - 13 0,85 - 1,1 140 - 165 13 - 18 0,85 - 1,1 J73KN-B-10 1NO f. low level switching maximal 4 J73KN-B.. Additional aux. contact blocks Side mounting Type contacts J73KN-B-01 1NC f. low level switching - J73KN-C-11S 1NO+1NC f. low level switching max. 2 J73KN-C-11S Overload Relay (thermal) Single phase protection Temperature compensation Trip and alarm contacts Type J7TKN-B Setting Ranges 0,12 - 0,18A 0,18 - 0,27A 0,27 - 0,4A 0,4 - 0,6A 0,6 - 0,9A 0,8 - 1,2A 1,2 - 1,8A 17 - (23)24A H-30 Motor Contactor J7KN J7TKN-A 1,8 - 2,7A 2,7 - 4A 4 - 6A 6 - 9A 8 - 11A 10 - 14A 13 - 18A (22)23 - (30)32A J7TKN-C Setting Ranges 28 - 42A J7TKN-D Setting Ranges 20 - 28A 28 - 42A 40 - 52A 52 - 65A 60 - 74A AC1 Type 400V Motor 380-400V 660-690V 690V at 40C Auxiliary contacts Type Auxiliary contacts Cable cross-section Solid mm2 Flexible mm2 Cables per clamp Auxiliary contact 40C A Ith AC15 230V A 400V A Power consumption of coils Inrush VA hold VA Operation range of coils Mounting Additional aux. contact blocks Front mounting Type contacts 85A 45kW 55kW 150A J7KN85-22 2NO+2NC - 110A 55kW 55kW 170A J7KN110-22 2NO+2NC - 150A 75kW 75kW 200A J7KN150-11 1NO+1NC - 175A 90kW 110kW 250A J7KN175-11 1NO+1NC - 210A 110kW 132kW 350A J7KN-20022 2NO+2NC - - - - - - 10 - 70 16 - 50 1 10 - 70 16 - 50 1 busbar 18x5 1 busbar 18x5 1 busbar 22x4 1 16 12 6 10 3 2 350 - 420 23 - 29 0,85 - 1,1 base 550 130 0,85 - 1,1 550 130 1100 66 - - - Additional aux. contact blocks Side mounting Type contacts LVSG Ratings AC3 - Overload Relay (thermal) Single phase protection Temperature compensation Trip and alarm contacts Type J7TKN-E Setting Ranges 60 - 90A 80 - 120A J7TKN-F Setting Ranges 100 - 150A 140 - 220A Busbar Sets J74TK-SU-175, J74TK-SU-200 Motor Contactor J7KN H-31 Contactors 3-pole AC Operated Rated Aux. Contacts Current Ratings AC2, AC3 AC1 660V 690V Weight Additional 380V 400V 415V kW 500V kW kW A NO NC Type 4 5.5 5.5 25 1 - max. 4 J73KN-B 690V see page 34 4 5.5 5.5 25 - 1 5.5 7.5 7.5 25 1 - 24 110 230 Coil Voltage*1 24V 50/60Hz 110V 50Hz 220-240V 50Hz J7KN-10-10#### pcs. kg/pc. 1 0.23 J7KN-10-01#### 1 0.23 J7KN-14-10#### 1 0.23 5.5 7.5 7.5 25 - 1 J7KN-14-01#### 1 0.23 7.5 10 10 32 1 - J7KN-18-10#### 1 0.23 7.5 10 10 32 - 1 J7KN-18-01#### 1 0.23 11 10 10 32 1 - J7KN-22-10#### 1 0.23 11 10 10 32 - 1 11 15 15 50 - - 15 18.5 18.5 65 - - 18.5 18.5 18.5 80 - - 22 30 30 110 - - 30 37 37 120 - - 37 45 45 130 - - Rated Aux. Contacts Current Ratings AC2, AC3 380V 415V kW 500V 45 AC1 1 0.23 max. 4 J7KN-24#### J73KN-B + J7KN-32#### 2 J73KNJ7KN-40#### C-11S 1 0.48 1 0.48 1 0.48 max. 4 J7KN-50#### J73KN-B + J7KN-62#### 2 J73KNJ7KN-74#### C11S 1 0.85 1 0.85 1 0.85 Pack Weight J7KN-22-01#### Type Built-in Coil Voltage*1 220-230V 50Hz 380-400V 50Hz 690V kW 660V 690V kW A NO NC 230 400 pcs. kg/pc. 55 55 150 2 2 J7KN-85-22#### 1 1.8 55 75 55 170 2 2 J7KN-110-22#### 1 1.9 75 75 75 200 1 1 J7KN-150-11#### 1 5 90 90 90 250 1 1 J7KN-175-11#### 1 5 110 132 132 350 2 2 J7KN-200-22#### 1 7.3 *1) Coil voltage range and other coil voltages see page 37 H-32 Built-in Pack Type Motor Contactor J7KN Contactors 3-pole DC Operated Coil voltage Type Aux. Contacts Built-in 24 60 110 220 24V DC 60V DC 110V DC 220V DC NO Weight Additional*1) Accept Overload Relay Busbar Set for Wiring Diagram Overload Relay page 57 page 59 Coil Circuits see page 36 NC Type kg/pc. Type Type Terminal Markings J7KN-10-10####D 1 - 0.25 -10 - 1 J7TKN-B J7TKN-A - J7KN-10-01####D max. 3 J73KN-B J7KN-14-10####D 1 - 0.25 - J7KN-14-01####D - 1 0.25 - J7KN-18-10####D 1 - 0.25 - J7KN-18-01####D - 1 0.25 - J7KN-22-10####D 1 - 0.25 - J7KN-22-01####D - 1 0.25 J7KN-24####D - - - - J7KN-40####D J7KN-50####D J7KN-62####D J7KN-74####D Coil voltage Type - - - - - - - - - - - - 2 1 0.55 - -11 - 0.55 - -21 max. 3 J73KN-B + 2 J73KNC-11S Aux. Contacts 110V DC 220V DC NO -01 J7TKN-B J7TKN-C 0.55 0.9 NC J7TKN-D 0.9 1.6 Weight Built-in 110 220 - Accept Overload Relay Busbar Set for -22 Overload Relay page H-59 page H-59 Type kg/pc. Type J7KN-85-21####D 2 1 - 1.8 J7TKN-E J7KN-110-21####D 2 1 - 1.9 LVSG J7KN-32####D max. 3 J73KN-B + 2 J73KNC-11S 0.25 J73TK-SU-175 J7TKN-F J73TK-SU-200 *1) Only 3 additional Aux. Contacts are possible! (See also the wiring diagrammms coil circuit DC operated page 36) Motor Contactor J7KN H-33 Contactors 4-pole AC Operated Rated Current Ratings Aux. Contacts Type AC2, AC3 AC1 AC1 380V 400V 415V kW 400V 690V kW A NO NC Type 4 17.5 25 - - max. 4 J73KN-B Built-in Additional see below Coil Voltage*1 24V 50/60Hz 110V 50Hz 220-240V 50Hz 24 110 230 J7KN-10-4#### Pack Weight pcs. kg/pc. 1 0.22 *1) Coil voltage range and other coil voltages see page 37 Auxiliary Contact Blocks for contactors J7KN-10... to -74... type J73KN for low level switching*1 Front mounting Rated Operational Current AC15 230V AC15 400V AC1 690V Contacts Type EM LB Pack Weight A A A NO NC pcs. kg/pc. 3 2 10 1 - - - J73KN-B-10 10 0.02 3 2 10 - 1 - - J73KN-B-01 10 0.02 Auxiliary Contact Blocks for contactors J7KN-24... to -74... type J73KN for low level switching*1 Side mounting Rated Operational Current AC15 230V AC15 400V Contacts Type Pack Weight pcs. kg/pc. J73KN-C-11S 10 0.02 Type Pack Weight pcs. kg/pc. J74KN-B-TP40DA 1 0.09 J74KN-B-TP180DA 1 0.09 J74KN-B-TP40IA 1 0.09 J74KN-B-TP180IA 1 0.09 AC1 690V A A A for side mounting NO NC 3 2 10 max. 2 1 1 Pneumatic Timer for contactors J7KN-10... to -22... Function Time range Contacts s 1. On-delay 0.1 - 40 1 On-delay 10 - 180 1 Off-delay 0.1 - 40 - Off-delay 10 - 180 - suitable according Technical data see page 51 H-34 to Motor Contactor J7KN DIN 19240 NO NC 1 1 - (test 1 1 NO NC 1 1 ratings 17V DC, 5mA) Mechanical Interlocks Interlocks contactor with contactor Type + Type J7KN10 - J7KN40 + J7KN10 - J7KN40 J7KN24 - J7KN74 + J7KN85 - J7KN110 + Mounting horizontal Type Pack J74KN-B-ML Weight pcs. kg/pc. 1 0.006 J7KN24 - J7KN74 horizontal J74KN-C-ML 1 0.010 J7KN85 - J7KN110 horizontal J74KN-D-ML 1 0.076 Type Pack Weight pcs. kg/pc. Suppressor Units Voltage Range Mounting V Varistor for contactors J7KN-10 to J7KN-22 110 - 230V AC/DC to snap on to coil terminals J74KN-A-VG230 10 0.01 250 - 415V AC/DC to snap on to coil terminals J74KN-A-VG400 10 0.01 Varistor for contactors J7KN-10 to J7KN-74 110 - 230V AC/DC to snap on the contactor J74KN-B-VG230 10 0.02 250 - 415V AC/DC to snap on the contactor J74KN-B-VG400 10 0.02 J74KN-A-RC230 1 0.036 RC-unit for contactors J7KN-10 to J7KN-40, J7KNA 110 - 230V AC/DC between DIN-rail and contactor RC-units for contactors J7KN-10 to J7KN-110 24 - 48V AC/DC universal (fixing band, adhesive strip) J74KN-B-RC48 5 0.02 110 - 230V AC/DC universal (fixing band, adhesive strip) J74KN-B-RC230 5 0.02 250 - 415V AC universal (fixing band, adhesive strip) J74KN-B-RC400 5 0.02 RC-units for contactors J7KN-10 to J7KN-74 to snap on the contactor J74KN-C-RC24 10 0.02 48 - 127V AC (50/60Hz) & DC to snap on the contactor J74KN-C-RC110 10 0.036 110 - 250V AC (50/60Hz) & DC to snap on the contactor J74KN-C-RC230 10 0.036 LVSG 12 - 48V AC (50/60Hz) & DC Motor Contactor J7KN H-35 Wiring Diagrams Coil Circuit AC operated DC operated with double winding coil*1 J7KN-10... to J7KN-175... J7KN-10...D to J7KN-22...D J7KN-200... J7KN-24...D to J7KN-74...D J7KN-85-...D to J7KN-110...D *1) Only 3 additional Aux. Contacts are possible! (See also page 33) H-36 Motor Contactor J7KN Specifications Coil Voltages Type-suffix for contactor types J7KN-10... to J7KN-74... Suffix to contactor type e.g. Voltage Marking at the coil Rated Control Voltage Us range for 50Hz 60Hz max min max J7KN-10-10-24 for 50Hz for 60Hz min V V V. V. V. V. 24 24 24 22 24 24 27 48 48 47 52 52 58 110 110 110-120 100 110 110 122 180 180-210 200-240 180 210 200 240 230 220-240 240 220 240 240 264 400 380-415 415-440 380 415 415 460 500 500-550 550-600 500 550 550 600 Standard voltages in bold type letter Type-suffix for contactor types J7KN-85... to J7KN-110... Suffix to contactor type e.g. Voltage Marking at the coil Rated Control Voltage Us range for 50Hz 60Hz max min max J7KN-85-22-24 for 50Hz for 60Hz min V V V. V. V. V. 24 24 24 27 29 32 48 48 60 47 52 56 62 110 110-120 110 122 132 146 180 180-200 208-240 180 200 208 240 230 220-240 277 220 240 264 288 400 380-415 460-480 380 415 455 498 500 500-550 600-660 500 550 600 660 Standard voltages in bold type letter Suffix Voltage Marking Rated Control Voltage Us to contactor type e.g. at the coil range for 50Hz J7KN-150-110 for 50Hz for 60Hz min V V V. max V. 60Hz min V. max V. 24 24 24 24 - - 48 48 48 48 - - 110 110 110 110 110 110 110 180 180 220 180 180 220 220 230 220-230 220 220 230 220 220 240 240 240 240 240 240 400 380-400 380 400 - - - - 440 440 440 240 440 LVSG Type-suffix for contactor types J7KN-150... to J7KN-200... Standard voltages in bold type letter Motor Contactor J7KN H-37 Engineering data and characteristics Approximate Values for three-phase Motors Motor Full Load Currents Approximate values of motor F.L.C. and minimum slow blow" respectively gL" short-circuit fuse Motor rating 220-230V Motor 240V Motor 380-400V Motor 415V Motor 500V Motor 660-690V Motor Range according to BS for 415V Value of fusing at motor start Value of fusing at motor start Value of fusing at motor start Value of fusing at motor start Value of fusing at motor start Value of fusing at motor start F.L.C. D.O.L. YD A A A F.L.C. D.O.L. YD A A A F.L.C. D.O.L. YD A A A F.L.C. D.O.L. YD A A A F.L.C. D.O.L. YD A A A F.L.C. D.O.L. YD A A A kW PS~hp hp cos % 0.06 0.08 - 0.7 59 0.38 1 1 0.35 1 1 0.22 1 1 - - - 0.16 1 1 - - - 0.09 0.12 - 0.7 60 0.55 2 2 0.5 2 2 0.33 1 1 - - - 0.24 1 1 - - - 0.12 0.16 - 0.7 61 0.76 2 2 0.68 2 2 0.42 2 2 - - - 0.33 1 1 - - - 0.18 0.24 - 0.7 61 1.1 2 2 1 2 2 0.64 2 2 - - - 0.46 1 1 - - - 0.25 0.34 - 0.7 62 1.4 4 2 1.38 4 2 0.88 2 2 - - - 0.59 2 2 - - - 0.37 0.5 - 0.72 64 2.1 4 4 1.93 4 4 1.22 4 2 - - - 0.85 2 2 0.7 2 2 0.55 0.75 - 0.75 69 2.7 4 4 2.3 4 4 1.5 4 2 - - - 1.2 4 2 0.9 2 2 0.75 1 1 0.8 74 3.3 6 4 3.1 6 4 2 4 4 2 4 4 1.48 4 2 1.1 2 2 1.1 1.5 1.5 0.83 77 4.9 10 6 4.1 6 6 2.6 4 4 2.5 4 4 2.1 4 4 1.5 4 2 1.5 2 2 0.83 78 6.2 10 10 5.6 10 10 3.5 6 4 3.5 6 4 2.6 4 4 2 4 4 2.2 3 3 0.83 81 8.7 16 10 7.9 16 10 5 10 6 5 10 6 3.8 6 6 2.9 6 4 2.5 3.4 - 0.83 81 9.8 16 16 8.9 16 10 5.7 10 10 - - - 4.3 6 6 - - - 3 4 4 0.84 81 11.6 20 16 10.6 20 16 6.6 16 10 6.5 16 10 5.1 10 10 3.5 6 4 3.7 5 5 0.84 82 14.2 25 20 13 25 16 8.2 16 10 7.5 16 10 6.2 16 10 - 4 5.5 - 0.84 82 15.3 25 20 14 25 20 8.5 16 10 - - - 6.5 16 10 4.9 5.5 7.5 7.5 10 7.5 10 - - 10 6 0.85 83 20.6 35 25 18.9 35 25 11.5 20 16 11 20 16 8.9 16 10 6.7 16 10 0.86 85 27.4 35 35 24.8 35 35 15.5 25 20 14 25 16 11.9 20 16 9 16 10 8 11 - 0.86 85 28.8 50 35 26.4 35 35 16.7 25 20 - - - 12.7 20 16 - - - 11 15 15 0.86 87 39.2 63 50 35.3 50 50 22 35 25 21 35 25 16.7 25 20 13 25 16 12.5 17 - 0.86 87 43.8 63 50 40.2 63 50 25 35 35 - - - 19 35 25 - - - 15 20 20 0.86 87 52.6 80 63 48.2 80 63 30 50 35 28 35 35 22.5 35 25 17.5 25 20 25 18.5 25 25 0.86 88 64.9 100 80 58.7 80 63 37 63 50 35 50 50 28.5 50 35 21 35 20 27 - 0.86 88 69.3 100 80 63.4 80 80 40 63 50 - - - 30.6 50 35 - - - 22 30 30 0.87 89 75.2 100 80 68 100 80 44 63 50 40 63 50 33 50 50 25 35 35 25 34 - 0.87 89 84.4 125 100 77.2 100 100 50 80 63 - - - 38 63 50 - - - 30 40 40 0.87 90 125 125 92.7 125 100 60 80 63 55 80 63 44 63 50 33 50 35 37 50 50 0.87 90 124 160 160 114 160 125 72 100 80 66 100 80 54 80 63 42 63 50 40 54 - 0.87 90 134 160 160 123 160 160 79 100 100 - - - 60 80 63 - - - 45 60 60 0.88 91 150 200 160 136 200 160 85 125 100 80 100 100 64.5 100 80 49 63 63 51 70 - 0.88 91 168 200 200 154 200 200 97 125 100 - - - 73.7 100 80 - - - 55 75 - 0.88 91 181 250 200 166 200 200 105 160 125 - - - 79 125 100 60 80 63 101 59 80 80 0.88 91 194 250 250 178 250 200 112 160 125 105 160 125 125 100 - - - 75 100 100 0.88 91 245 315 250 226 315 250 140 200 160 135 200 160 106 85.3 160 125 82 125 100 90 125 125 0.88 92 292 400 315 268 315 315 170 250 200 165 200 200 128 160 160 98 125 125 110 150 150 0.88 92 358 500 400 327 400 400 205 250 250 200 250 250 156 200 200 118 160 125 129 175 175 0.88 92 420 500 500 384 500 400 242 315 250 230 315 250 184 250 200 - - - 132 180 - 0.88 92 425 500 500 393 500 500 245 315 250 - - - 186 250 200 140 200 160 147 200 200 0.88 93 472 630 630 432 630 500 273 315 315 260 315 315 207 250 250 - - - 160 220 - 0.88 93 502 630 630 471 630 630 295 400 315 - - - 220 315 250 170 200 200 184 250 250 0.88 93 590 800 630 541 630 630 340 400 400 325 400 400 259 315 315 - - - 200 270 - 0.88 93 626 800 800 589 800 630 370 500 400 - - - 278 315 315 215 250 250 220 300 300 0.88 93 700 1000 800 647 800 800 408 500 500 385 500 400 310 400 400 - - - 250 340 - 0.88 93 803 1000 1000 736 1000 800 460 630 500 - - - 353 500 400 268 315 315 257 350 350 0.88 93 826 1000 1000 756 1000 800 475 630 630 450 630 500 363 500 400 - - - 295 400 400 0.88 93 948 1250 1000 868 1000 1000 546 800 630 500 630 630 416 500 500 - - - 315 430 - 0.88 93 990 1250 1250 927 1250 1000 580 800 630 - - - 445 630 500 337 400 400 355 483 - 0.89 95 - - - - - - 636 800 800 - - - 483 630 630 366 500 400 400 545 - 0.89 96 - - - - - - 710 1000 800 - - - 538 630 630 410 500 500 The motor F.L.C. be valid for standard internal and surface cooled three-pole motors with 1500 min . The fuses values be valid for the motor F.L.C. shown in the table and D.O.L.-start: starting current max. 6x motor F.L.C., starting time max. 5s; star-delta-start: starting current max. 2x motor F.L.C., starting time max. 15s. For motors with higher F.L.C., higher starting current and / or longer starting time, larger short-circuit fuses are required. -1 The maximum admissible value is dependent on the switchgear respectively thermal overload relay. H-38 Motor Contactor J7KN Approximate values of motor F.L.C. according to CSA and UL Motor rating hp 1/2 Motor F.L.C. at 110-120V Motor F.L.C. at 220-240V*1 Motor F.L.C. at 440-480V 1-phase 2-phase 3-phase 1-phase 2-phase 3-phase 1-phase 2-phase 3-phase 1-phase 2-phase A A A A A A A A A A A A 9.8 4.0 4.4 4.9 2.0 2.2 2.5 1.0 1.1 2.0 0.8 0.9 Motor F.L.C. at 550-600V 3-phase 3/4 13.8 4.8 6.4 6.9 2.4 3.2 3.5 1.2 1.6 2.8 1.0 1.3 1 16.0 6.4 8.4 8.0 3.2 4.2 4.0 1.6 2.1 3.2 1.3 1.7 11/2 20.0 9.0 12.0 10.0 4.5 6.0 5.0 2.3 3.0 4.0 1.8 2.4 2 24.0 11.8 13.6 12.0 5.9 6.8 6.0 3.0 3.4 4.8 2.4 2.7 3 34.0 16.6 19.2 17.0 8.3 9.6 8.5 4.2 4.8 6.8 3.3 3.9 5 56.0 26.4 30.4 28.0 13.2 15.2 14.0 6.6 7.6 11.2 5.3 6.1 71/2 80.0 38.0 44.0 40.0 19.0 22.0 21.0 9.0 11.0 16.0 8.0 9.0 10 100.0 48.0 56.0 50.0 24.0 28.0 26.0 12.0 14.0 20.0 10.0 11.0 15 135.0 72.0 84.0 68.0 36.0 42.0 34.0 18.0 21.0 27.0 14.0 17.0 20 - 94.0 108.0 88.0 47.0 54.0 44.0 23.0 27.0 35.0 19.0 22.0 25 - 118.0 136.0 110.0 59.0 68.0 55.0 29.0 34.0 44.0 24.0 27.0 30 - 138.0 160.0 136.0 69.0 80.0 68.0 35.0 40.0 54.0 28.0 32.0 40 - 180.0 208.0 176.0 90.0 104.0 88.0 45.0 52.0 70.0 36.0 41.0 50 - 226.0 260.0 216.0 113.0 130.0 108.0 56.0 65.0 86.0 45.0 52.0 60 - - - - 133.0 145.0 - 67.0 77.0 - 53.0 62.0 77.0 75 - - - - 166.0 192.0 - 83.0 96.0 - 66.0 100 - - - - 218.0 248.0 - 109.0 124.0 - 87.0 99.0 125 - - - - - 312.0 - 135.0 156.0 - 108.0 125.0 150 - - - - - 360.0 - 156.0 180.0 - 125.0 144.0 200 - - - - - 480.0 - 208.0 240.0 - 167.0 192.0 250 - - - - - 602.0 - - 302.0 - - 242.0 300 - - - - - - - - 361.0 - - 289.0 350 - - - - - - - - 414.0 - - 336.0 400 - - - - - - - - 477.0 - - 382.0 500 - - - - - - - - 590.0 - - 472.0 LVSG *1) Determine the motor current for 200V and 208V by increasing the values for 220-240V at 200V about 15% and for 208V about 10%. Motor Contactor J7KN H-39 Contactors Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Main Contacts Type Rated insulation voltage Ui*1 J7KN-10 V AC 690 J7KN-14 690 J7KN-18 690 J7KN-22 690 J7KN-24 690 J7KN-32 690 J7KN-40 690 J7KN-50 690 J7KN-62 690 J7KN-74 690 at Ue = 690V AC A 200 200 200 200 400 500 500 700 900 900 Breaking capacity Ieff 400V AC A 180 180 200 200 380 400 400 600 800 800 J7KN-10 to J7KN-22 cos = 0,65 500V AC A 150 150 180 180 300 370 370 500 700 700 J7KN-24 to J7KN-72 cos = 0,35 690V AC A 100 100 150 150 260 340 340 400 500 500 - - - - - - - - - Making capacity Ieff 1000V AC A Utilization category AC1 Switching of resistive load Rated operational current Ie (=Ith) at 40C, open 25 25 32 32 50 65 80 110 120 130 220V kW 9,5 9,5 12,2 12,2 19,0 24,7 30,4 41,9 45,7 49,5 230V kW 9,9 9,9 12,7 12,7 19,9 25,9 31,8 43,8 47,7 51,7 240V kW 10,4 10,4 13,3 13,3 20,8 27,0 33,2 45,7 49,8 54,0 380V kW 16,4 16,4 21,0 21,0 32,9 42,7 52,6 72,3 78,9 85,5 400V kW 17,3 17,3 22,1 22,1 34,6 45,0 55,4 76,1 83,0 90,0 415V kW 17,9 17,9 23,0 23,0 35,9 46,7 57,4 79,0 86,2 93,3 440V kW 19,0 19,0 24,4 24,4 38,1 49,5 60,9 83,7 91,3 99,0 500V kW 21,6 21,6 27,7 27,7 43,3 56,2 69,2 95,2 103,8 112,5 660V kW 28,5 28,5 36,5 36,5 57,1 74,2 91,3 125,6 137,0 148,4 690V kW 29,8 29,8 38,2 38,2 59,7 77,6 95,5 131,3 143,2 155,2 - - - - - - - - - - Rated operational current Ie (=Ithe) at 60C, enclosed A 25 25 32 32 40 55 65 90 100 110 Rated operational power of three-phase resistive loads 50-60Hz, cos = 1 220V kW 9,5 9,5 12,2 12,2 15,2 20,9 24,7 34,3 38,1 41,9 230V kW 9,9 9,9 12,7 12,7 15,9 21,9 25,9 35,8 39,8 43,8 240V kW 10,4 10,4 13,3 13,3 16,6 22,8 27,0 37,4 41,5 45,7 380V kW 16,4 16,4 21,0 21,0 26,3 36,2 42,7 59,2 65,7 72,3 400V kW 17,3 17,3 22,1 22,1 27,7 38,1 45,0 62,3 69,2 76,1 415V kW 17,9 17,9 23,0 23,0 28,7 39,5 46,7 64,6 71,8 79,0 440V kW 19,0 19,0 24,4 24,4 30,4 41,9 49,5 68,5 76,1 83,7 Rated operational power of three-phase resistive loads 50-60Hz, cos = 1 A 1000V kW 500V kW 21,6 21,6 27,7 27,7 34,6 47,6 56,2 77,9 86,5 95,2 660V kW 28,5 28,5 36,5 36,5 45,7 62,8 74,2 102,8 114,2 125,6 131,3 690V kW 29,8 29,8 38,2 38,2 47,7 65,7 77,6 107,4 119,4 - - - - - - - - - - mm 4 4 6 6 10 16 25 35 50 50 74 1000V kW Minimum cross-section of conductor at load with Ie (=Ith) Utilization category AC2 and AC3 Switching of three-phase motors Rated operational current Ie open and enclosed 220V A 12 15 18 22 24 30 40 50 63 230V A 11,5 14,5 18 22 24 30 40 50 62 74 240V A 11 14 18 22 24 32 40 50 62 74 380-400V A 10 14 18 22 24 32 40 50 62 74 415V A 9 14 18 22 23 30 40 50 62 74 440V A 9 14 18 22 23 30 40 50 62 74 500V A 7 9 9 9 17,5 21 21 33 42 42 6,5 8,5 8,5 8,5 17 20 20 31 40 40 - - - - - - - - - 220-230V kW 3 4 5 6 6 8,5 11 12,5 18,5 22 240V kW 3 4 5 7 7 9 11,5 13,5 19 23 380-400V kW 4 5,5 7,5 11 11 15 18,5 22 30 37 415V kW 4,5 6 8,5 12 12 16 20 24 33 40 440V kW 4,5 6 8,5 12 12 16 20 24 33 40 500V kW 5,5 7,5 10 10 15 18,5 18,5 30 37 45 10 660-690V A 1000V A Rated operational power of three-phase motors 50-60Hz 660-690V kW 1000V kW 5,5 7,5 10 - - - 15 18,5 18,5 30 37 45 - - - - - - Utilization category AC4 Switching of squirrel cage motors, inching Rated operational current Ie (=Ith) open and enclosed H-40 220V A 12 15 18 18 24 30 40 50 63 63 230V A 11,5 14,5 18 18 24 30 40 50 62 62 240V A 11 14 18 18 24 32 40 50 62 62 380-400V A 10 14 18 18 24 32 40 50 62 62 415V A 9 14 18 18 23 30 37 45 60 60 440V A 9 14 18 18 23 30 37 45 55 55 500V A 9 12 16 16 17,5 21 21 33 42 42 660V A 7 9 9 9 17 20 20 31 40 40 690V A 6,5 8,5 8,5 8,5 17 20 20 31 40 40 1000V A - - - - - - - - - Motor Contactor J7KN Main Contacts Rated operational power of three-phase motors 50-60Hz Type 220-230V kW J7KN-10 3 J7KN-14 4 J7KN-18 5 J7KN-22 5 J7KN-24 6 J7KN-32 8,5 J7KN-40 11 J7KN-50 12,5 J7KN-62 18,5 J7KN-74 18,5 240V kW 3 4 5 5 7 9 11,5 13,5 19 19 380-400V kW 4 5,5 7,5 7,5 11 15 18,5 22 30 30 415V kW 4,5 6 8,5 8,5 12 16 20 24 33 33 440V kW 4,5 6 8,5 8,5 12 16 20 24 33 33 500V kW 5,5 7,5 10 10 15 18,5 18,5 30 37 37 660-690V kW 5,5 7,5 10 10 1000V kW - - - 15 18,5 18,5 30 37 37 - - - - - - 104 Utilization category AC 5a Switching of gas discharge lamps Rated operational current Ie per pole at 220/230V Fluorescent lamps, uncompensated and serial compensated A 20 20 25 25 40 52 64 88 96 parallel compensated A 7 9 9 9 18 22 22 30 40 45 dual-connection A 22,5 22,5 28 28 45 58 72 98 108 117 uncompensated A 12 15 19 19 30 39 48 66 72 78 parallel compensated A 7 9 9 9 18 22 22 30 40 45 uncompensated A 22,5 25 28 28 45 58 72 99 108 117 parallel compensated A 7 9 9 9 18 22 22 30 40 45 Mixed light lamps*4 A 20 20 25 25 40 52 64 88 96 104 A 12,5 12,5 12,5 12,5 25 31 31 43 56 56 30 Metal halide lamps*2, Mercury-vapour lamps*3, Utilization category AC5b Switching of incandescent lamps*5 Rated operational current Ie per pole at 220/230V Utilization category AC6a Transformer primary switching at inrush n 30 30 30 30 30 30 30 30 30 Rated operational current Ie 400V A 4,5 5,5 7,5 7,5 10,5 13,5 13,5 20 27 33 Rated operational power dependent on inrush n 220-230V kVA 1,8 2,2 3 3 4,2 5,4 5,4 8 10,7 13 For different inrush-factors x use the following formula: Px=Pn*(n/x) 240V kVA 1,9 2,3 3,1 3,1 4,3 5,6 5,6 8,3 11,2 13,5 380-400V kVA 3,1 3,8 5,2 5,2 7,3 9,3 9,3 13,5 18,5 22,5 415-440V kVA 3,4 4,2 5,7 5,7 8 10,2 10,2 15 20,5 25 500V kVA 3,9 4,8 6,5 6,5 9 11,5 11,5 17 23 28 660-690V kVA 5,4 6,5 9 9 12,5 16 16 24 32 39 k 35 25 20 20 25 25 25 25 25 20 Maximum inrush current (peak value) as multiple k of the capacitor rated current LVSG Utilization category AC6b Switching of three-phase capacitor banks Rated operational current Ie 500V A 8 12 15,5 15,5 23 32 32 45 60 70 Rated operational power (sin1) 220-230V kVAr 3 4,5 6 6 8,5 12 12 17 24 28 240V kVAr 3,5 5 6,5 6,5 9,5 13 13 18,5 25 29 380-400V kVAr 5 7,5 10 10 15 20 20 29 39 46 415-440V kVAr 5,5 8 11 11 16 22 22 32 43 50 500V kVAr 7 10 13 13 20 26 26 39 50 58 660-690V kVAr 7 10 13 13 20 26 26 40 50 58 Rated operational current Ie 690V A 13 18 20 28 36 42 48 72 105 1) Rated operational power 220-230V kVAr 2,9 5 7 7,5 11 14 16 20 28 33 For different multiples x use the following formula: Px=Pk*(k/x) Switching of detuned capacitors 8 240V kVAr 3,1 5,4 7 8 11 14 17 20 28 36 380-400V kVAr 5 9 12,5 13 20 25 27,5 33,3 50 75 1) 415-440V kVAr 5,5 9,5 13 14 22 27 30 36 53 75 1) 500V kVAr 6 11 15 17 25 30 36 40 60 75 660-690V kVAr 8 15 20 22 33 41 48 55 82 100 Utilization category DC1 Switching of resistive load Time constant L/R 1ms Rated operational current Ie 1 pole24V A 20 25 32 32 50 65 80 110 120 130 60V A 20 25 32 32 50 65 80 110 120 130 110V A 6 6 6 6 10 10 10 12 12 12 220V A 0,8 0,8 0,8 0,8 1,4 1,4 1,4 1,4 1,4 1,4 3 poles in series 24V A 20 25 32 32 50 65 80 110 120 130 60V A 20 25 32 32 50 65 80 110 120 130 110V A 20 25 32 32 50 65 80 110 120 130 220V A 16 20 20 20 30 35 35 63 80 80 Motor Contactor J7KN H-41 Main Contacts Type J7KN-10 J7KN-14 J7KN-18 J7KN-22 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 J7KN-74 Utilization category DC3 and DC5 Switching of shunt motors and series motors Time constant L/R 15ms 1 pole24V A 20 25 32 32 50 65 80 110 120 130 6 6 6 6 30 30 30 60 60 60 110V A 1,2 1,2 1,2 1,2 1,8 1,8 1,8 1,8 1,8 1,8 220V A 0,2 0,2 0,2 0,2 0,2 0,2 0,2 0,25 0,25 0,25 3 poles in series 24V A 20 25 32 32 50 65 80 110 120 130 60V A 20 25 32 32 40 40 40 80 80 80 110V A 20 20 20 20 40 40 40 80 80 80 220V A 2,5 2,5 2,5 2,5 4 4 4 5 5 5 open C -40 to +60 (+90)*6 Rated operational current Ie 60V A Maximum ambient temperature Operation enclosed C with thermal overload relay -40 to +40 open C -25 to +60 enclosed C -25 to +40 Storage C -50 to +90 Short circuit protection for contactors without thermal overload relay Coordination-type "1" according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size gL (gG) A 63 63 63 63 80 80 80 160 160 160 gL (gG) A 25 35 35 35 50 50 50 100 125 125 gL (gG) A 16 16 16 16 25 35 35 50 63 63 Coordination-type "2" according to IEC 947-4-1 Light contact welding accepted max. fuse size Contact welding not accepted max. fuse size For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable cross-sections for contactors without thermal overload relay main connector solid or stranded mm 0,75 - 6 flexible mm 1 - 4 flexible with multicore cable end mm 0,75 - 4 Cables per clamp 2 solid or stranded mm 6+(1-6) / 4+(0,75-4) 2,5+(0,75-2,5) / 1,5+(0,75-1,5) flexible mm 6+(1,5-6) / 4+(1-4) 2,5+(0,75-2,5) / 1,5+(0,75-1,5) Cables per clamp 2 main connector solid AWG 18 - 10 flexible AWG 18 - 10 1,5 - 25 4 - 50 2,5 - 16 10 - 35 1,5 - 16 6 - 35 1 1 16+(2,5-6) / 10+(4-10) 50+4 / 35+6 / 25+(6-16) 6+(4-6) / 4+(2,5-4) 16+(6-16) / 10+(6-16) 16+(2,5-6) / 10+(4-10) 50+(4-10) / 35+(4-16) 6+(4-6) / 4+(2,5-4) 25+(4-25) / 16+(4-16) 2 2 16 - 10 12 - 10 14 - 4 10 - 0 1 1 solid AWG 10+(16-10) / 12+(18-12) 10+(16-10) / 12+(18-12) 10+(12-10) / 12+12 14+(18-14) / 16+(18-16) 14+(18-14) / 16+(18-16) Cables per clamp 2 flexible AWG 10+(14-10) / 12+(18-12) Cables per clamp 4+(18-12) / 6+(18-8) 1+(12-10) / 2+(8-12) 14+(18-14) / 16+(18-16) 8+(18-8) / 10+(18-12) 3+(12-8) / 4+(10-6) 2 2 2 Frequency of operations z Contactors without thermal overload relay without load 1/h 10000 10000 10000 7000 7000 7000 7000 7000 7000 AC3, Ie 1/h 600 10000 600 600 600 600 600 600 400 400 400 AC4, Ie 1/h 120 120 120 120 120 120 120 120 120 120 DC3, Ie 1/h 600 600 600 600 600 600 600 400 400 400 Mechanical life AC operated S x 106 10 10 10 10 10 10 10 10 10 10 DC operated S x 106 10 10 10 10 10 10 10 10 10 10 Short time current Power loss per pole 10s-current at Ie/AC3 400V A 96 120 144 176 184 240 296 360 504 592 W 0,21 0,35 0,5 0,75 0,7 1,3 2 2,2 3,9 5,5 Resistance to shock acc. to IEC 68-2-27 Shock time 20ms sine-wave NO g 10 10 10 10 8 8 8 8 8 8 NC g 6 6 6 6 - - - - - - *1) Suitable at 690V for: earthed-neutral systems, overvoltage I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. *2) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps) *3) High-pressure lamps *4) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps) *5) Current inrush approx. 16 x Ie *6) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie/AC1 according to Ie/AC3 H-42 Motor Contactor J7KN Main Contacts Type J7KN-85 J7KN-110 J7KN-150 J7KN-175 Rated insulation voltage Ui *1 V AC 750 750 690 690 690 1200 1500 1800 1700 Making capacity Ieff at Ue = 690V AC A 1100 J7KN-200 Breaking capacity Ieff 400V AC A 950 1100 1200 1400 1600 J7KN-10 to J7KN-22 cos = 0,65 500V AC A 850 1000 1200 1400 1600 600 600 700 800 1200 - - - - - J7KN-24 to J7KN-72 cos = 0,35 690V AC A 1000V AC A Utilization category AC1 Switching of resistive load Rated operational current Ie (=Ith) at 40C, open 150 170 200 250 350 220V kW 57 64 72 90 125 230V kW 59 67 72 90 125 240V kW 62 70 75 94 130 380V kW 98 111 125 156 218 400V kW 103 117 125 156 218 415V kW 107 122 130 160 225 440V kW 114 129 144 180 250 500V kW 130 147 164 205 285 660V kW 171 194 216 270 380 690V kW 179 203 216 270 380 - - - - - Rated operational current Ie (=Ithe) at 60C, enclosed A 100 125 160 200 280 Rated operational power of three-phase resistive loads 50-60Hz, cos = 1 220V kW 38 47 60 76 106 230V kW 40 49 63 79 111 240V kW 41 52 66 83 116 380V kW 65 82 105 131 184 400V kW 69 86 110 138 193 415V kW 71 89 115 143 201 440V kW 71 95 121 152 213 500V kW 86 108 138 173 242 660V kW 114 142 182 228 320 690V kW 119 149 191 239 334 - - - - - 70 95 120 185 Rated operational power of three-phase resistive loads 50-60Hz, cos = 1 A 1000V kW 1000V kW Minimum cross-section of conductor at load with Ie (=Ith) mm 50 Rated operational current Ie open and enclosed 220V A 85 110 150 175 210 230V A 85 110 150 175 210 240V A 85 110 150 175 210 380-400V A 85 110 150 175 210 415V A 85 110 150 175 210 440V A 85 110 - - - 500V A 660-690V A 1000V A 220-230V kW Rated operational power of three-phase motors 50-60Hz 60 60 - - - 57,5 57,5 - - - - - - - - 25 33 40 50 60 240V kW 27 35 45 55 65 380-400V kW 45 55 75 90 110 415V kW 49 63 80 95 115 440V kW 49 63 85 100 125 500V kW 55 75 75 100 132 660-690V kW 55 55 75 110 132 - - - - - 1000V kW LVSG Utilization category AC2 and AC3 Switching of three-phase motors Utilization category AC4 Switching of squirrel cage motors, inching Rated operational current Ie (=Ith) open and enclosed 220V A 85 98 55 63 85 230V A 85 98 55 63 85 240V A 85 98 55 63 85 380-400V A 85 85 55 63 85 415V A 85 85 - - - 440V A 85 85 - - - 500V A 85 85 - - - 660V A 60 60 - - - 690V A 57,5 57,5 - - - 1000V A - - - - - Motor Contactor J7KN H-43 Main Contacts Rated operational power of three-phase motors 50-60Hz Type J7KN-85 J7KN-110 J7KN-150 J7KN-175 220-230V kW 25 30 15 18,5 J7KN-200 25 240V kW 27 32 15,5 19 26 380-400V kW 45 45 25 30 45 415V kW 49 49 25 33 45 440V kW 49 49 30 34 48 500V kW 55 55 25 30 55 660-690V kW 55 55 25 30 55 1000V kW - - - - - Utilization category AC 5a Switching of gas discharge lamps Rated operational current Ie per pole at 220/230V Fluorescent lamps, uncompensated and serial compensated A 100 120 120 140 180 parallel compensated A 55 70 85 100 120 dual-connection A 112 144 120 140 180 Metal halide lamps*2, uncompensated A 85 90 95 110 140 parallel compensated A 55 70 75 85 110 Mercury-vapour lamps*3, uncompensated A 112 144 120 140 180 parallel compensated A 55 70 75 85 110 Mixed light lamps*4 A 100 120 100 120 160 A 69 75 100 120 160 Utilization category AC5b Switching of incandescent lamps*5 Rated operational current Ie per pole at 220/230V Utilization category AC6a Transformer primary switching at inrush n 30 30 30 30 30 Rated operational current Ie 400V A 38 50 65 80 90 Rated operational power dependent on inrush n 220-230V kVA 15 20 25 30 34 240V kVA 15,5 20,5 27 33 37 380-400V kVA 26 34 45 55 60 415-440V kVA 29 38 46 57 63 500V kVA 33 43 55 69 75 45 60 56 69 100 k 20 20 20 20 15 87 195 For different inrush-factors x use the following formula: Px=Pn*(n/x) 660-690V Utilization category AC6b Switching of three-phase capacitor banks Maximum inrush current (peak value) as multiple k of the capacitor rated current Rated operational current Ie 500V A 100 120 155 Rated operational power (sin1) 220-230V kVAr 33 38 45 60 75 240V kVAr 36 42 52 62 78 380-400V kVAr 57 65 80 100 130 415-440V kVAr 60 70 95 110 135 500V kVAr 70 80 100 130 170 660-690V kVAr 70 80 100 130 170 For different multiples x use the following formula: Px=Pk*(k/x) Switching of detuned capacitors Rated operational current Ie 690V A 105 115 140 200 Rated operational power 220-230V kVAr 35 98 40 43 53 76 240V kVAr 39 43 45 55 80 380-400V kVAr 68 75 75 90 130 415-440V kVAr 71 77 80 100 140 500V kVAr 85 90 95 120 170 660-690V kVAr 110 120 125 150 200 Utilization category DC1 Switching of resistive load Time constant L/R 1ms Rated operational current Ie H-44 1 pole24V A 150 170 - - - 60V A 150 170 - - - 110V A 20 25 - - - 220V A 2 2,5 - - - 3 poles in series 24V A 150 170 200 250 350 60V A 150 170 200 250 350 110V A 150 170 150 170 250 220V A 100 160 80 100 150 Motor Contactor J7KN Main Contacts Type J7KN-85 J7KN-110 J7KN-150 J7KN-175 J7KN-200 - Utilization category DC3 and DC5 Switching of shunt motors and series motors Time constant L/R 15ms 1 pole24V A Rated operational current Ie 150 170 - - 60V A 85 110 - - - 110V A 2 2,5 - - - 220V A 0,5 0,5 - - - 3 poles in series 24V A 150 170 - - - 60V A 100 110 - - 110V A 100 110 - - - 220V A 7 8 - - - open C -40 to +60 (+90)*6 Maximum ambient temperature Operation -25 to +55 (+70)*7 enclosed C -40 to +40 -25 to +40 open C -25 to +60 -25 to +55 with thermal overload relay enclosed C -25 to +40 -25 to +40 Storage C -50 to +90 -55 to +80 Short circuit protection for contactors without thermal overload relay Coordination-type "1" according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size gL (gG) A 250 250 250 315 400 gL (gG) A 160 200 200 250 315 gL (gG) A 100 125 160 200 250 10 - 70*8 95 120 185 16 - 50*8 screw screw screw 10 - 35 M8 M8 M8 Coordination-type "2" according to IEC 947-4-1 Light contact welding accepted max. fuse size Contact welding not accepted max. fuse size For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable cross-sections for contactors without thermal overload relay solid or stranded mm 10 - 70*8 main connector flexible mm 6 - 50*8 flexible with multicore cable end mm 10 - 35 Cables per clamp solid or stranded mm LVSG flexible mm Cables per clamp main connector solid AWG 10 flexible AWG 6 - 0 Cables per clamp 10 6-0 1 1 solid AWG flexible AWG Cables per clamp Frequency of operations z Contactors without thermal overload relay without load 1/h 3000 3000 1200 1200 1200 AC3, Ie 1/h 300 300 - - - AC4, Ie 1/h 120 120 - - - DC3, Ie 1/h 300 300 - - - AC operated S x 106 5 5 10 10 8 DC operated S x 106 5 5 10 10 8 10s-current A 680 880 1200 1400 1800 at Ie/AC3 400V W 4,3 6,0 8 11 8 Mechanical life Short time current Power loss per pole Resistance to shock acc. to IEC 68-2-27 Shock time 20ms sine-wave NO g 7 7 - - - NC g 5 5 - - - *1) Suitable at 690V for: earthed-neutral systems, overvoltage I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. *2) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps) *3) High-pressure lamps *4) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps) *5) Current inrush approx. 16 x Ie *6) With reduced control voltage range 0,9 up to 1,0 x Us and with reduced rated current Ie/AC1 according to Ie/AC3 *7) With reduced control voltage range 1,0 x Us and with reduced rated current Ie/AC1 according to Ie/AC3 *8) Maximum cable cross-section with prepared conductor Motor Contactor J7KN H-45 Contactors Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Auxiliary Contacts Type J7KN-10 J7KN-14 J7KN-18 J7KN-22 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 J7KN-74 Rated insulation voltage Ui*1 V~ 690 690 690 690 - - - - - - 40C A 16 16 16 16 - - - - - - 60C A 12 12 12 12 - - - - - - 220-240V A 12 12 12 12 - - - - - - 380-415V A 4 4 4 4 - - - - - - 440V A 4 4 4 4 - - - - - - 500V A 3 3 3 3 - - - - - - 660-690V A 1 1 1 1 - - - - - - Thermal rated current Ith to 690V Ambient temperature Utilization category AC15 Rated operational current Ie Utilization category DC13 Rated operational current Ie 60V A 8 8 8 8 - - - - - - 110V A 1 1 1 1 - - - - - - 220V A 0,1 0,1 0,1 0,1 - - - - - - gL (gG) A 25 25 25 25 - - - - - - Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse. Control Circuit Power consumption of coils AC operated DC operated inrush VA 33-45 90-115 sealed VA 7-10 9-13 140-165 13-18 W 2,6-3 2,7-4 5,4-7 inrush W 75 140 200 sealed W 2 2 6 AC operated 0,85-1,1 0,85-1,1 0,85-1,1 DC operated 0,8-1,1 0,8-1,1 0,8-1,1 make time ms 8-16 10-25 12-28 release time ms 5-13 8-15 8-15 10-15 Operation range of coils in multiples of control voltage Us Switching time at control voltage Us 10%*2,*3 AC operated arc duration ms DC operated 10-15 10-15 make time ms 8-12 10-20 12-23 release time ms 8-13 10-15 10-18 arc duration ms 10-15 10-15 10-15 - - - - Cable cross-section Auxiliary connector solid mm 0,75-6 flexible mm 1-4 flexible with multicore cable end Magnet coil - - 0,75-2,5 0,75-2,5 flexible mm 0,5-2,5 0,5-2,5 0,5-2,5 flexible with multicore cable end mm 0,5-1,5 0,5-1,5 0,5-1,5 2 2 solid AWG 18 - 10 - - flexible AWG 18 - 10 - - 14 - 12 14 - 12 solid mm 0,75-2,5 Clamps per pole 2 Auxiliary connector Magnet coil mm 0,75-4 solid AWG 14 - 12 flexible AWG 18 - 12 Clamps per pole 2 18 - 12 18 - 12 2 2 *1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request *2) Total breaking time = release time + arc duration *3) Values for delay of the release time of the making contact and the make time of the break contact will be increased, if magnet coils are protected against voltage peaks (varistor, RC-unit, diode-unit) H-46 Motor Contactor J7KN Auxiliary Contacts Type J7KN-85 J7KN-110 J7KN-150 J7KN-175 J7KN-200 Rated insulation voltage Ui*1 V~ 690 690 690 690 690 Thermal rated current Ith to 690V Ambient temperature 40C A 16 16 10 10 10 60C A 12 12 - - - 220-240V A 12 12 3 3 3 380-415V A 6 6 2 2 2 440V A 6 6 1,5 1,5 1,5 500V A 4 4 1,5 1,5 1,5 660-690V A 2 2 1 1 1 - Utilization category AC15 Rated operational current Ie Utilization category DC13 Rated operational current Ie 60V A 8 8 - - 110V A 1 1 0,5 0,5 1 220V A 0,1 0,1 0,2 0,2 0,5 gL (gG) A 25 25 10 10 10 inrush VA 280-350 350-420 550 550 1100 sealed VA 16 -23 23 -29 120 120 66 W 4-6 6-7,3 - - - inrush W 170 320 160 160 530 sealed W 2 4 5 5 21 Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse. Control Circuit Power consumption of coils AC operated DC operated Operation range of coils in multiples of control voltage Us AC operated 0,85-1,1 0,85-1,1 0,85-1,1 0,85-1,1 DC operated 0,8-1,1 0,85-1,1 0,85-1,1 0,85-1,1 30-40 AC operated make time ms DC operated 13-30 12-30 12-30 release time ms 8-15 15-40 15-40 15-45 arc duration ms 10-15 - - make time ms 20-30 - - release time ms 10-18 - - - arc duration ms 10-15 - - - LVSG Switching time at control voltage Us 10%*2,*3 Cable cross-section Auxiliary connector flexible with multicore cable end Magnet coil solid mm 0,75-2,5 0,75-2,5 flexible mm 0,75-2,5 0,75-2,5 mm 0,5-1,5 solid mm 0,75-2,5 flexible mm 0,5-2,5 flexible with multicore cable end mm 0,5-1,5 Clamps per pole Auxiliary connector Magnet coil 14 - 12 1-2,5 1-2,5 16 - 12 solid AWG 18 - 12 16 - 12 flexible AWG 14 - 12 16 - 12 solid AWG 18 - 12 flexible AWG 2 Clamps per pole - 0,75-2,5 16 - 12 2 0,75-2,5 *1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request *2) Total breaking time = release time + arc duration *3) Values for delay of the release time of the making contact and the make time of the break contact will be increased, if magnet coils are protected against voltage peaks (varistor, RC-unit, diode-unit) Motor Contactor J7KN H-47 Contactors for North America Data according to UL508 Main Contacts (cULus) Type J7KN-10 J7KN-14 J7KN-18 J7KN-22 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 J7KN-74 Rated operational current "General Use" A 25 30 30 50 65 80 110 120 130 Rated operational power 11/2 2 2 3 5 5 71/2 10 10 10 200V hp 3 3 5 5 71/2 10 10 15 20 25 220-240V hp 3 3 71/2 71/2 10 10 15 20 25 30 277V hp 3 5 71/2 71/2 71/2 10 15 20 25 30 380-415V hp 5 5 10 10 10 15 20 25 30 40 440-480V hp 5 71/2 10 15 15 20 25 30 40 50 550-600V hp 71/2 10 15 20 20 25 30 40 50 50 110-120V hp 1/2 3/4 1 11/2 11/2 2 3 3 5 71/2 of AC motors 200V hp 1 1,5 2 3 3 5 71/2 71/2 10 15 at 60Hz (1ph) 220-240V hp of three-phase motors at 60Hz (3ph) Rated operational power Rated operational power of three-phase motors at 60Hz (3ph) for elevators 110-120V hp 25 11/2 2 3 3 5 5 71/2 10 15 15 277V hp 2 3 3 5 5 71/2 10 10 15 15 380-415V hp 3 3 5 5 5 71/2 10 15 20 20 440-480V hp 3 5 5 71/2 71/2 10 15 20 25 25 550-600V hp 3 5 71/2 10 10 15 20 25 30 30 110-120V hp - - - - 2 3 - 3 5 - 200V hp - - - - 3 5 - 71/2 10 - 220-240V hp - - - - 5 71/2 - 71/2 10 - Demands according to ANSI A17.5 (500.000 operations) Rated operationalcurrent Fuses 440-480V hp - - - - 10 15 - 20 25 - 550-600V hp - - - - 10 20 - 25 30 - - - - - 15 22 - 27 37 - 30 40 50 50 90 125 175 175 225 250 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 600 600 600 600 600 600 600 600 600 600 A600 A600 A600 A600 - - - - - - 600V A A Suitable for use on a capability of delivering not more than rms A V Auxiliary Contacts (cULus) Main Contacts (cULus) Type J7KN-85 J7KN-110 J7KN-150 J7KN-175 J7KN-200 Rated operational current "General Use" A 125 - - - Rated operational power of three-phase motors at 60Hz (3ph) 110-120V hp 200V hp 220-240V hp 125 15 - - - - - 30 - - - 35 40 - - - 277V hp - - - - - 380-415V hp - - - - - 440-480V hp 65 75 - - - 550-600V hp 85 100 - - - 110-120V hp 8 10 - - - of AC motors 200V hp - 20 - - - at 60Hz (1ph) 220-240V hp Rated operational power Rated operational power of three-phase motors at 60Hz (3ph) for elevators 20 20 - - - 277V hp - - - - - 380-415V hp - - - - - 440-480V hp - 50 - - - 550-600V hp - 60 - - - 110-120V hp - - - - - 200V hp - - - - - 220-240V hp - - - - - Demands according to ANSI A17.5 (500.000 operations) Rated operationalcurrent Fuses 440-480V hp - - - - - 550-600V hp - - - - - 600V A - 62 - - - A - 300 - - - 10000 10000 - - - 600 600 - - - A600 A600 - - - Suitable for use on a capability of delivering not more than rms A V Auxiliary Contacts (cULus) H-48 Motor Contactor J7KN Contactors Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Contact Life For selection of the suitable contactor-type according to supply voltage, power rating and application (utilization category AC1, AC3 or AC4) use contact life characteristic diagram. For contactors frequently used under AC3/AC4-mixed service conditions calculate contact life with the formula: AC3 M = --------------------------------------------------------%AC4 AC3 1 + ----------------- x ----------- - 1 100 AC4 For the most common supply voltages four scales of power ratings Pn are provided for each utilization category. Select contactor-type according to utilization category AC3 (breaking current Ia = Ie) using the motor rating scales to the right, according to utilization category AC4 (breaking current Ia = 6 x Ie) using the motor rating scales to the left.*1 Select contactor-type according to utilization category AC1 (breaking current Ia = Ie/AC1) using the breaking current scale.*1 M = Contact life (switching cycles) for AC3/AC4-mixed operations AC3 = Contact life (switching cycles) for AC3 operations (normal switching conditions). Breaking current Ia = rated motor current In. AC4 = Contact life (switching cycles) for AC4 operations (inching). Breaking current Ia= multiples of rated motor current In. %AC4 = Percents of AC4-operations related to the total cycles. Pay attention to the approved rated values of the selected contactor according to the national approvals Motor Rating Pn/AC4 Motor Rating Pn/AC3 Breaking Current Ia (=Ie/AC1) A J7KN-74 J7KN-62 J7KN-50 J7KN-40 J7KN-32 J7KN-24 J7KN-22 J7KN-18 J7KN-14 J7KN-12 J7KN-10 J7KN-09 LVSG 1. millions of operations Motor Contactor J7KN H-49 Motor Rating Pn/AC4 Motor Rating Pn/AC3 Breaking Current Ia (=Ie/AC1) A J7KN-200 J7KN-175 J7KN-150 J7KN-110 J7KN-85 millions of operations H-50 Motor Contactor J7KN Contactors Utilization Categories For easier choice of devices and in order to make the comparison of different products simplier are utilization categories for contactors and motor-starters according to IEC 947-4-1 and VDE 0660 Part 102 ,for Rated operational current Test conditions for the number of on-load operating cycles Alternating Current Make Break Make Break Ic/Ie Ur/Ue cos AC1 Non-inductive or all values slightly inductive loadsresistance furnaces 1 1 0.95 1 1 0.95 1.5 1.05 0.8 1.5 1.05 0.8 AC2 Slip-ring motors: starting, switching off 2.5 1 0.65 2.5 1 0.65 4 1.05 0.65 4 1.05 0.65 AC3 Squirrel-cage motors: 17A< Ie starting, switching off moIe tors during running Ie> 17A 0.45 Squirrel-cage motors: 17A< Ie starting, plugging, inching Ie AC4 all values Ie> I/Ie U/Ue cos Ic/Ie Ur/Ue cos I/Ie U/Ue cos 6 1 0.65 1 0.17 0.65 10 1.05 0.45 8 1.05 100A 6 1 0.35 1 0.17 0.35 10 1.05 0.45 8 1.05 0.45 100A 6 1 0.35 1 0.17 0.35 10 1.05 0.35 8 1.05 0.35 17A 0.45 6 1 0.65 6 1 0.65 12 1.05 0.45 10 1.05 100A 6 1 0.35 6 1 0.35 12 1.05 0.45 10 1.05 0.45 100A 6 1 0.35 6 1 0.35 12 1.05 0.35 10 1.05 0.35 AC5a Switching of electric discharge lamp controls all values - - - - - - 3 1.05 0.45 3 1.05 0.45 AC5b Switching of incandescent lamps all values - - - - - - 1.5 1.05 1) 4 1.05 1) Ie 100A - - - - - - 4.5 1.05 0.45 3.6 1.05 0.45 Ie> 100A - - - - - - 4.5 1.05 0.35 3.6 1.05 0.35 - - - - - - 2) - - - - - - 1.5 1.05 0.8 1.5 1.05 0.8 0.45 AC6a Switching of transformers AC6b Switching of capacitor banks - AC7a Slightly inductive loads in all values household appliances and similar applications 2) AC7b Motor loadsfor household applications Ie 100A - - - - - - 8 1.05 0.45 6 1.05 Ie> 100A - - - - - - 8 1.05 0.35 6 1.05 0.35 AC8a Hermetic refrigerant compressor motor control with manualresetting of overload releases Ie 100A - - - - - - 6 1.05 0.45 6 1.05 0.45 Ie> 100A - - - - - - 6 1.05 0.35 6 1.05 0.35 AC8b Hermetic refrigerant compressor motor control with automatic resetting of overload releases Ie 100A - - - - - - 6 1.05 0.45 6 1.05 0.45 Ie> 100A - - - - - - 6 1.05 0.35 6 1.05 0.35 AC12 Control of resistive loads all values and solid state loads with isolation by opto couplers - - - - - - 1 1 0.9 1 1 0.9 AC13 Control of solid state loads with transformer isolation - - - - - - 10 1.1 0.65 1.1 1.1 0.65 AC14 Control of small electro- magnetic loads (<=72VA) - - - - - - 6 1.1 0.7 6 1.1 0.7 AC15 Control of electromagnetic load (>72VA) 10 1 0.7 1 1 0.4 10 1.1 0.3 10 1.1 0.3 all values - Make Direct Current Test conditions for making and breaking capacities L/R Break L/R Make L/R Break I/Ie U/Ue [ms] Ic/Ie Ur/Ue [ms] I/Ie U/Ue [ms] Ic/Ie Ur/Ue L/R [ms] DC1 Non-inductive or all values slightly inductive loads resistance furnaces 1 1 1 1 1 1 1.5 1.05 1 1.5 1.05 1 DC3 Shunt-motors: starting, all values plugging, inching dynamic braking of d.c. motors 2.5 1 2 2.5 1 2 4 1.05 2.5 4 1.05 2.5 DC5 Series-motors: all values starting, plugging, inching dynamic braking of d.c. motors 2.5 1 7.5 2.5 1 7.5 4 1.05 15 4 1.05 15 DC6 Switching of incandescent lamps all values - - - - - - 1.5 1.05 1) 4 1.05 1) DC12 Control of resistive loads all values and solid state loads with isolation by opto couplers - - - - - - 1 1 1 1 1 1 DC13 Control of electromagnets all values 1 1 300 1 1 300 1.1 1.1 300 1.1 1.1 300 DC14 Control of electromagnet- all values ic loads having economy resistors in circuit - - - - - - 10 1.1 15 10 1.1 15 U Rated operational voltage, U Voltage before make, U Recovery voltage, I Rated operational current, I Current make, I Current broken e r e c 1) Test with incandescent lamps 2) Test conditions according to standard Motor Contactor J7KN H-51 LVSG Type of Cate- Typical applications current gory control circuit devices and switching elements according to IEC 947-51 and VDE 0660 Part 200 determind. The table offers different utilization categories, typical applications and assorted test conditions. Accessories Data according to IEC 947-5-1, EN 60947-5-1, VDE 0660 Auxiliary Contacts Type J73KN-B J73KN-C J73KN-B-TP... Rated insulation voltage Ui*1 V~ 690 690 690 40C A 10 10 10 60C A 6 6 - Thermal rated current Ith to 690V Ambient temperature Frequency of operations z 1/h 3000 3000 1200 Mechanical life Sx 106 10 10 1 Power loss per pole at Ie/AC1 W 0,5 0,5 - 220-240V A 3 3 4 380-400V A 2 2 3 440V A 1,6 1,6 2 500V A 1,2 1,2 2 660-690V A 0,6 0,6 2 Utilization category AC15 Rated operational current Ie Utilization category DC13 Rated operational current Ie 60V A 2 2 2,5 110V A 0,4 0,4 1,5 220V A 0,1 0,1 0,2 gL (gG) A 20 20 10 Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size For contactors with thermal overload relay or auxiliary contacts the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size. Cable cross-sections solid or stranded mm 0,75-2,5 0,75-2,5 1-2,5 flexible mm 0,75-2,5 0,75-2,5 0,75-2,5 flexible with multicore cable end mm 0,5-1,5 Cables per clamp 2 0,5-1,5 0,75-2,5 2 2 *1) Suitable for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request Data according to CSA, UL and CUL Auxiliary Contacts Type J73KN-B J73KN-C J73KN-B-TP... Rated operational current General Use" A 10 10 600 600 A600 A600 Rated operational voltage 10 max. V AC 600 Auxiliary Contacts A600 Contactors and Accessories Wiring diagrams Auxiliary contact blocks J73KN-B-10 J73KN-B-01 Pneumatic timer J73KN-C-11S*1 (left side) (right side) 53 61 71 83 54 62 *1) Correct terminal marking is given by mounting H-52 Motor Contactor J7KN 72 84 on-delayed off-delayed J74KN-B-TP...DA J74KN-B-TP...IA AC operated DC operated J7KN-10... J7KN-10-4 J7KN-14... J7KN-18... J7KN-22... J7KN-10...D J7KN-14...D J7KN-18...D J7KN-22...D J7KN-24... J7KN-32... J7KN-40... J7KN-24...D J7KN-32...D J7KN-40...D J7KN-50... J7KN-62... J7KN-74... J7KN-50...D J7KN-62...D J7KN-74...D LVSG Dimensions Motor Contactor J7KN H-53 AC operated J7KN-85... J7KN-110... J7KN-200... J7KN-150... J7KN-175... Auxiliary contact blocks J73KN-B-01 J73KN-B-10 H-54 J73KN-C-11S Motor Contactor J7KN Pneumatic timer J74KN-B-TP... Auxiliary contact blocks J74KN-A-RC J74KN-B-VG J74KN-B-RC LVSG J74KN-A-VG Motor Contactor J7KN H-55 Position of Terminals AC operated J7KN-10-10 to J7KN-22-10 J7KN-10-01 to J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 J7KN-74 J7KN-85-22 J7KN-110-22 J7KN-50...D J7KN-62...D J7KN-74...D J7KN-81-21...D J7KN-110-21...D J7KN-200-22 DC operated with double winding coil J7KN-10-01...D J7KN-14-01...D J7KN-18-01...D J7KN-22-01...D J7KN-10-10...D J7KN-14-10...D J7KN-18-10...D J7KN-22-10...D J7KN-24...D J7KN-32...D J7KN-40...D ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J505-E2-02 H-56 In the interest of product improvement, specifications are subject to change without notice. Motor Contactor J7KN Thermal Overload Relay J7TKN ) Thermal Overload Relay * Direct and separate mounting * Single phasing sensivity according to IEC 947-4-1 * Finger proof (VBG 4) Accessories * Busbar sets * Set for single mounting Approved Standards Standard Guide No (US,C) UL NKCR, NKCR7 ICE 947-4-1 VDE 0660 EN 60947-4-1 Ordering Information 1. Thermal Overload Relay J7TKN-#-### 1 2 3 1) 2) 3) Thermal Overload Relay A: for mini motor contactor and motor contactor (4-11 kW) B: for motor contactor (4-15 kW) C: for motor contactor (18.5 kW) D: for motor contactor (22-37 kW) E: for motor contactor (45-55 kW) F: for motor contactor (75-110 kW) Setting range (examples) E16: 0.12-0.16 A E27: 0.18-0.27 A ... 2E7: 1.8-2.7 A ... 11: 8-11 A LVSG Model Number Legend 2. Accessories for Thermal Overload Relay J74TK-##-### 1 2 3 1) 2) 3) Accessories for Thermal Overload Relay SM: Single mounting for J7TKN-B Types (4-32 kW) SU: Busbar sets 175: for J7TKN-F Types (75-90 kW) 200: for J7TKN-F Types (110 kW) Thermal Overload Relay J7TKN H-57 System overview Thermal Overload Relays for plug-in mounting Setting Range Type (A) D.O.L. (A) Star Delta Pack Weight pcs. kg/pc. For contactors J7KNA-09..., J7KNA-12..., J7KN-10... to J7KN-22... 0.12 - 0.18 - J7TKN-A-E18 1 0.10 0.18 - 0.27 - J7TKN-A-E27 1 0.10 0.27 - 0.4 - J7TKN-A-E4 1 0.10 0.4 - 0.6 - J7TKN-A-E6 1 0.10 0.6 - 0.9 - 0.8 - 1.2 - hand reset J7TKN-A-E9 1 0.10 J7TKN-A-1E2 1 0.10 0.10 1.2 - 1.8 - J7TKN-A-1E8 1 1.8 - 2.7 - J7TKN-A-2E7 1 0.10 2.7 - 4 - J7TKN-A-4 1 0.10 4 - 6 7 - 10.5 J7TKN-A-6 1 0.10 6 - 9 10.5 - 15.5 J7TKN-A-9 1 0.10 8 - 11 14 - 19 J7TKN-A-11 1 0.10 10 - 14 18 - 24 J7TKN-A-14 1 0.10 13 - 18 23 - 31 J7TKN-A-18 1 0.10 17 - 23 30 - 40 J7TKN-A-23 1 0.10 22 - 30 38 - 52 J7TKN-A-30 1 0.10 For contactors J7KN-10... to J7KN-40... 0.12 - 0.18 - J7TKN-B-E18 1 0.14 0.18 - 0.27 - J7TKN-B-E27 1 0.14 0.27 - 0.4 - J7TKN-B-E4 1 0.14 0.4 - 0.6 - J7TKN-B-E6 1 0.14 0.6 - 0.9 - 0.8 - 1.2 - hand- and auto reset J7TKN-B-E9 1 0.14 J7TKN-B-1E2 1 0.14 1.2 - 1.8 - J7TKN-B-1E8 1 0.14 1.8 - 2.7 - J7TKN-B-2E7 1 0.14 0.14 2.7 - 4 J7TKN-B-4 1 4 - 6 7 - 10.5 J7TKN-B-6 1 0.14 6 - 9 10.5 - 15.5 J7TKN-B-9 1 0.14 8 - 11 14 - 19 J7TKN-B-11 1 0.14 10 - 14 18 - 24 J7TKN-B-14 1 0.14 13 - 18 23 - 31 J7TKN-B-18 1 0.14 17 - 24 30 - 41 J7TKN-B-24 1 0.14 23 - 32 40 - 55 J7TKN-B-32 1 0.14 48 - 73 J7TKN-C-42 1 0.30 For contactors J7KN-24... to J7KN-40... 28 H-58 - 42 Thermal Overload Relay J7TKN Setting Range Type (A) D.O.L. (A) Star Delta Pack Weight pcs. kg/pc. For contactors J7KN-50...-J7KN-74... 40 - 52 70 - 90 J7TKN-D-52 1 0.40 52 - 65 90 - 112 J7TKN-D-65 1 0.40 60 - 74 104 - 128 J7TKN-D-74 1 0.40 Thermal Overload relays for separate mounting Setting Range Type (A) D.O.L. (A) Star Delta Pack Weight pcs. kg/pc. For contactors J7KN-85... to J7KN-150... 60 - 90 104 - 156 J7TKN-E-90 1 0.90 80 - 120 140 - 207 J7TKN-E-120 1 0.90 hand reset For contactors J7KN-175... to J7KN-200... 100 - 150 175 - 260 J7TKN-F-150 1 1.5 140 - 220 240 - 380 J7TKN-F-210 1 1.5 busbar sets see accessories hand reset Type for overload relays for contactors Pack Weight pcs. kg/pc. Busbar Sets J7TKN-F-175 J7KN-150, J7KN-175 J74TK-SU-175 1 0.6 J7TKN-F-210 J7KN-200 J74TK-SU-200 1 0.7 Type Pack Weight pcs. kg/pc. 1 0.035 busbars must be installed by users Cable Cross-section to clamp (mm) for overload relay solid or stranded flex. with multicore cable end flexible Sets for single mounting J7TKN-B 0.75 - 6 0.75 - 4 0.5 - 4 J74TK-SM Thermal Overload Relay J7TKN H-59 LVSG Accessories Specifications Engineering data and Characteristics Thermal Overload Relays, tripping times for selection to motors of protection degree EEx e Relays With Standard Tripping Characteristic Setting Range Tripping time depending on the multiple of the current setting from cold condition (tolerance 20% of the tripping time) I /I A A I /I N A 3 A N 4 A N I /I A 6 s s N I /I I /I 7,2 8 A N N Typical tripping curve for overload relay J7TKN-A s 0,12 - 0,18 18,5 10,4 7,2 5,5 4,3 3,6 0,18 - 0,27 16,7 9,8 6,5 5 4,1 3,5 0,27 - 0,4 19,4 12,1 8,2 5,9 4,9 4,2 0,4 - 0,6 18,7 11,2 8 6 4,9 4,1 0,6 - 0,9 19,7 11,6 8,1 6,1 4,9 4,2 0,8 - 1,2 22,9 13,6 10 7,3 6 5,2 1,2 - 1,8 22,2 13,2 9,2 7,6 5,8 5,3 1,8 - 2,7 23 13,7 9,3 7,6 5,7 5,1 2,7 - 4 24 14,4 9,9 7,8 5,9 5,1 4 - 6 24,7 13,8 9,9 7,3 5,6 4,8 6 - 9 22 13,4 8 5,7 4,1 3,5 8 - 11 17,4 9,2 5,9 4,1 2,9 2,3 Labels of tripping curves for each setting range, sized 148x105mm (self-adhesive) are available on request. 10 - 14 26,4 12,9 7,6 5,2 3,5 2,8 Specify type and setting range. 13 - 18 14,7 7,7 4,8 3,2 2,3 1,7 17 - 23 16,2 8,4 5 3,6 2,4 1,8 22 - 30 16,8 8,5 5 3,6 2,3 1,9 s s 8 5,5 s s s 28 25,2 - 42 s 13,3 s s s 4 s 40 - 52 18,3 9,2 5,6 3,9 2,8 52 - 65 17,8 8,7 5,2 3,4 2,5 1,9 60 - 74 19,5 13,5 11 10 9,5 8,5 s s 13,5 11 10 9,5 8,5 11 10 9 8,5 8 s s s 60 - 90 19,5 80 - 120 18 s s s 3,1 J7TKN-D-... J7TKN-E-... s s A J7TKN-A-... J7TKN-C-42 s I /I 5 All tripping times of overload relays J7TKN-A are shorter than the minimum values of the tE time for motors of protection degree EEx e acc. to EN 50019 and therefore are suitable for all motors of protection degree EEx e. For these overload relays the selection on basis of tripping curves is thereby not necessary. s s 2,2 s J7TKN-F-... s s s 100 - 150 34 26 24 20,5 19 18 140 - 210 30 24 21 18,5 17 16 When selecting a standard overload, refer to the tripping curve. Determine the values of the starting current ratio IA/IN and the time tE which is marked on the label of the motor. The overload must trip within the tE time, which means that the tripping curve from cold condition must be (20% due to tolerance) below the coordination point IA/ IN and the time tE. IA= Starting current of motor IN = Rated current of motor tE = tE-time of motor H-60 Thermal Overload Relay J7TKN Minimum values of tE time (motor) acc. to EN50019 ratio IA/IN Fuses for J7TKN-A; J7TKN-B; J7TKN-C; J7TKN-D; J7TKN-E; J7TKN-F Type Setting Range Max. Fuse Size According to Coordination-type Fuse UL "2"*1 DOL Star Delta A A J7TKN-A J7TKN-B "1"*1 quick slow, gL(gG) A A *2 0.5 *2 slow, gL(gG) aM A A A 0.12 - 0.18 - 0.5 25 - 15 0.18 - 0.27 - 1.0*2 1.0*2 25 - 15 0.27 - 0.4 - 2 2 25 - 15 0.4 - 0.6 - 2 2 25 - 15 0.6 - 0.9 - 4 4 25 - 15 0.8 - 1.2 - 4 4 25 2 15 1.2 - 1.8 - 6 6 25 2 15 1.8 - 2.7 - 10 10 25 4 15 2.7 - 4 - 16 10 25 4 15 4 - 6 20 16 25 6 15 6 - 9 10.5 - 15.5 35 25 35 10 25 8 - 11 14 - 19 35 25 35 16 30 10 - 14 18 - 24 50 35 63 16 40 13 - 18 23 - 31 50 35 63 20 50 17 (22)23 - (23)24 - (30)32 7 30 (38)40 - 10.5 - (40)41 63 50 63 25 60 - (52)55 80 63 80 35 70 73 100 80 150 50 110 J7TKN-C 28 - 42 48 - J7TKN-D 40 - 52 70 - 90 160 100 150 63 200 52 - 65 90 - 112 160 125 150 80 250 60 - 74 104 - 128 160 125 150 80 250 J7TKN-E J7TKN-F 60 - 90 104 - 156 80 - 120 140 - 207 For short circuit protecting overload relays with current transformer use fuse according to the 7contactor of the combination. all ranges 300 - Thermal Overload Relay LVSG *1) Coordination-type according to IEC 947-4-1: 2": Light contact welding accepted. Thermal overload relay must not be damaged. 1": Welding of contactor and damage of the thermal overload relay allowed. *2) Miniature fuse J7TKN H-61 Tripping Characteristics for J7TKN-A, J7TKN-B, J7TKN-C, J7TKN-D Detailed tripping times for each range see table page 60 with three-phase load with two-pole load Tripping time min. s Tripping time min. s Average value of typical tolerance curves from cold condition Typical tolerance curve from cold condition Proceeding from service conditions the times decrease to 70-80% of the characteristic values Proceeding from service conditions the times decrease to 20-30% of the characteristic values K = Imax/Ie Imax = max. phase current Ie = max. scale value F.L.C. multiplication factor K Tripping Characteristics for J7TKN-E Detailed tripping times for each range see table page 60 with three-phase load with two-pole load Tripping time min. s Tripping time min. s Average value of typical tolerance curves from cold condition Typical tolerance curve from cold condition Proceeding from service conditions the times decrease to 70-80% of the characteristic values Proceeding from service conditions the times decrease to 20-30% of the characteristic values K = Imax/Ie Imax = max. phase current Ie = max. scale value F.L.C. multiplication factor H-62 Thermal Overload Relay J7TKN K Tripping Characteristics for J7TKN-F Detailed tripping times for each range see table page 60 with three-phase load with two-pole load Tripping time min. s Tripping time min. s Average value of typical tolerance curves from cold condition Typical tolerance curve from cold condition Proceeding from service conditions the times decrease to 70-80% of the characteristic values Proceeding from service conditions the times decrease to 20-30% of the characteristic values K = Imax/Ie Imax = max. phase current Ie = max. scale value F.L.C. multiplication factor K Position of Terminals J7TKN-B J7TKN-C; J7TKN-D LVSG J7TKN-A Thermal Overload Relay J7TKN H-63 Thermal Overload Relays Data according to IEC 947-4-1, IEC 947-5-1, VDE 0660, EN 60947-4-1, EN 60947-5-1 Type Rated insulation voltage Ui*1 V~ J7TKN-A J7TKN-B J7TKN-C J7TKN-D J7TKN-E J7TKN-F 690 690 690 690 750 690 Permissible ambient temperature operation open storage C -25 to +60 C -50 to +70 10A 10A 10A 10A 20 20 mm 0.75-6 + 0.75-2.5*2 0.75-6 0,75-10 4-35*2 *3 *4 flexible mm 0.75-4 + 0.5-2.5*2 1-4 0,75-6 6-25*2 flexible with multicore cable end mm 0.5-2.5 + 0.5-1.5 0.75-4 0.75-6 4-25 2 2 1 Trip class according to IEC 947-4-1 Cable cross-section main connector solid or stranded Cables per clamp number 1+1 solid mm 0.75-2.5*2 flexible mm 0.5-2.5*2 flexible with multicore cable end mm 0.5-1.5 auxiliary connector Cables per clamp number 2 Auxiliary contacts Rated insulation voltage Ui*1 same potential V~ 690 690 690 690 different potential V~ 440 440 250 440 24V A 5 3 4*5 5 230V A 3 2 2.5 3 400V A 2 1 1.5 2 690V A 0.6 0.5 0.6 0.6 Utilization category AC15 Rated operational current Ie Utilization category DC13 Rated operational current Ie 24V A 1.2 1 1.2 1.2 110V A 0.15 0.15 0.15 0.15 220V A 0.1 0.1 0.1 0.1 gL (gG) A 6 4 6 6 A to 23 all Short circuit protection (without welding 1kA) highest fuse rating Setting range 28-42 52-65 all - Power loss per current path (max.) minimum setting value W 1.1 1.1 1.3 2.9 1.1 - maximum setting value W 2.3 2.3 3.3 4.5 2.5 - *1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry: Uimp = 4kV (at 440V), 6kV (at 690V). Data for other conditions on request. *2) Maximum cable cross-section with prepared conductor *3) Without terminals, suitable for bushing one connector 70mm (stranded) per phase *4) Busbar sets see accessories page 59 *5) Switching capacity of the start contact: AC15 300VA, max. 1.5A, DC13 (max. 220V) 30W, max. 1.5A H-64 Thermal Overload Relay J7TKN Data according to CULUS Type J7TKN-A J7TKN-B J7TKN-C J7TKN-D J7TKN-E Rated insulation voltage V~ 600 600 600 600 600 Rated current A 23 32 42 74 85 Auxiliary contacts Rated voltage same potential V AC 600 600 600 600 600 different potential V~ 150 150 150 150 150 Switching capacity AC VA 500 500 600 600 600 of aux. contacts A 4 2 4 4 4 Temperature Compensation In case of higher ambient temperature use the following formula: (Ambient temperature - 20) x 0.125 = correction factor in % of the full load motor current Example: Ambient temperature 70C, full load motor current 7A (70 - 20) x 0.125 = 6.25% LVSG Setting value: 7A + 6,25% = 7.44A Thermal Overload Relay J7TKN H-65 Dimensions J7KNA-09 + J7TKN-A J7KNA-12 J7KN-10 + J7TKN-B J7KN-14 J7KN-18 J7KN-22 J7KN-10 + J7TKN-A J7KN-14 J7KN-18 J7KN-22 J7KN-24 + J7TKN-B J7KN-32 J7KN-40 H-66 Thermal Overload Relay J7TKN J7KN-50 + J7TKN-D J7KN-62 J7KN-74 J7KN-85 + J7TKN-E J7KN-110 J7KN-150 + J7TKN-F J7KN-175 LVSG J7KN-24 + J7TKN-C J7KN-32 J7KN-40 J7KN-200 + J7TKN-210 Thermal Overload Relay J7TKN H-67 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J509-E2-02 H-68 In the interest of product improvement, specifications are subject to change without notice. Thermal Overload Relay J7TKN Motor Protection Circuit Breaker (MPCB) J7MN ) MPCB system (motor protection CLASS 10) * Rotary and switch types * Rated operational current = 12 A, 25 A, 50 A and 100 A * Switching capacity up to 12.5 A = 100 kA/400 V * Fixed short-circuit release = 13 x Iu * Overload release adjustable 0.7 - 1 x Iu * Single phasing sensivity Auxiliary contact modules * ON/OFF indication for MPCB front mounting and side mounting * Trip indication for MPCB side mounting Accessories * Undervoltage release * Shunt release * Three phase busbar system up to 5 MPCB * Moulded plastic enclosures (IP55) * Moulded plastic front plates (IP55) * Door coupling rotary mechanisms (black and red/yellow) Standard Guide No (US,C) UL see page 95 LVSG Approved Standards ICE 947-5-1 VDE 0660 EN 60947-5-1 Motor Protection Circuit Breaker (MPCB) J7MN H-69 Ordering Information Model Number Legend 1. Motor Protection Circuit Breaker (MPCB) 3. Accessories for MPCB J7MN-##-### 1 2 3 J74MN-#-## 1 2 3 1) 2) 1) 2) Motor Protection Circuit Breaker (MPCB) Type 12: Switch type (0.16 - 12 A) 25: Rotary type (0.16 - 25 A) 50: Rotary type (25 - 40 A) 100: Rotary type (45 - 100 A) 3) Setting range (examples) E16: 0.11 - 0.16 A E2: 0.14 - 0.2 A 16: 10 - 16 A ... 2. Aux. Contacts for MPCB J73MN-### 1 2 3 1) 2) 3) J74MN-## ## 1 2 3 1) 2) 3) Aux. Contact for MPCB 11: 1 NO 1 NC S: side mounting F: front mounting J73MN-#-## # 1 2 3 4 1) 2) 3) 4) 3) Aux. Contact for MPCB T: Trip indicating contact 11: 1 NO 1 NC S: side mounting Accessories for MPCB S: Shunt release U: Under voltage release N1: 230 V 50 Hz / 240 V 60 Hz N2: 210 - 230 V 50/60 Hz Accessories for MPCB PF: Enclosure IP55 P: Module plastic front plate PH: Holder for front plate 12: Switch type 25: Rotary type J74MN-##-## 1 2 3 1) 2) 3) Accessories for MPCB DC: Door coupling rotary mechanism B: black / gray RY: red / yellow J74MN-##-#/# 1 2 3 1) 2) 3) Accessories for MPCB L3: 3-phase busbar system (45 mm modular spacing) DS: Shroud for unused terminal 1/2: for 2 circuit breakers 1/3: for 3 circuit breakers 1/4: for 4 circuit breakers 1/5: for 5 circuit breakers J74MN-## ## 1 2 3 1) 2) 3) Accessories for MPCB TC: Line side terminal 12: for switch type 25: for rotary type J74MN-## ### 1 2 3 1) 2) 3) H-70 Motor Protection Circuit Breaker (MPCB) J7MN Accessories for MPCB TB: Terminal block for UL/cUL type E 25: for rotary type up to 25A 100: for rotary type up to 100A System overview Motor Protection Circuit Breaker (MPCB) Current setting range Pack Weight approx. pcs. kg/pcs. J7MN-12-E16 1 0.21 J7MN-12-E2 1 0.21 100 J7MN-12-E25 1 0.21 4.2 100 J7MN-12-E32 1 0.21 0.28 - 0.4 5.2 100 J7MN-12-E4 1 0.21 0.12 0.35 - 0.5 6.5 100 J7MN-12-E5 1 0.21 0.63 0.18 0.45 - 0.63 8.2 100 J7MN-12-E63 1 0.21 0.8 - 0.55 - 0.8 10 100 J7MN-12-E8 1 0.21 1 0.25 0.7 - 1 13 100 J7MN-12-1 1 0.21 1.25 0.37 0.9 - 1.25 16 100 J7MN-12-1E25 1 0.21 1.6 0.55 1.1 - 1.6 21 100 J7MN-12-1E6 1 0.21 2 0.75 1.4 - 2 26 100 J7MN-12-2 1 0.21 2.5 - 1.8 - 2.5 33 100 J7MN-12-2E5 1 0.21 3.2 1.1 2.2 - 3.2 42 100 J7MN-12-3E2 1 0.21 4 1.5 2.8 - 4 52 100 J7MN-12-4 1 0.21 5 - 3.5 - 5 65 100 J7MN-12-5 1 0.21 6.3 2.2 4.5 - 6.3 82 100 J7MN-12-6E3 1 0.21 8 3 5.5 - 8 104 50 J7MN-12-8 1 0.21 10 4 7- 10 130 50 J7MN-12-10 1 0.21 12 5.5 9- 12 156 50 J7MN-12-12 1 0.21 Suitable for motors*1 3~400V kW Instantaneous short-circuit release A Short-circuit breaking capacity at 3~400V kA Type Thermal overload release A 0.16 - 0.11 - 0.16 2.1 100 0.2 - 0.14 - 0.2 2.6 100 0.25 0.06 0.18 - 0.25 3.3 0.32 0.09 0.22 - 0.32 0.4 - 0.5 Rated current In A Circuit-Breakers J7MN-12 LVSG *1) Recommended values for standard motors *2) max. motor current 95A Motor Protection Circuit Breaker (MPCB) J7MN H-71 Rated current Current setting range Suitable for motors*1 3~400V kW Instantaneous short-circuit release A Short-circuit breaking capacity at 3~400V kA Type Thermal overload release A Pack Weight approx. pcs. kg/pcs. 0.16 - 0.11 - 0.16 2.1 100 0.2 - 0.14 - 0.2 2.6 100 J7MN-25-E16 1 0.32 J7MN-25-E2 1 0.25 0.06 0.18 - 0.25 3.3 0.32 100 J7MN-25-E25 1 0.32 0.09 0.22 - 0.32 0.32 4.2 100 J7MN-25-E32 1 0.4 - 0.32 0.28 - 0.4 5.2 100 J7MN-25-E4 1 0.5 0.32 0.12 0.35 - 0.5 6.5 100 J7MN-25-E5 1 0.32 0.63 0.18 0.45 - 0.63 8.2 100 J7MN-25-E63 1 0.32 0.8 - 0.55 - 0.8 10 100 J7MN-25-E8 1 0.32 1 0.25 0.7 - 1 13 100 J7MN-25-1 1 0.32 1.25 0.37 0.9 - 1.25 16 100 J7MN-25-1E25 1 0.32 1.6 0.55 1.1 - 1.6 21 100 J7MN-25-1E6 1 0.32 2 0.75 1.4 - 2 26 100 J7MN-25-2 1 0.32 2.5 - 1.8 - 2.5 33 100 J7MN-25-2E5 1 0.32 3.2 1.1 2.2 - 3.2 42 100 J7MN-25-3E2 1 0.32 4 1.5 2.8 - 4 52 100 J7MN-25-4 1 0.32 5 - 3.5 - 5 65 100 J7MN-25-5 1 0.32 6.3 2.2 4.5 - 6.3 82 100 J7MN-25-6E3 1 0.32 8 3 5.5 - 8 104 100 J7MN-25-8 1 0.32 10 4 7- 10 130 100 J7MN-25-10 1 0.32 12.5 5.5 9- 12.5 163 100 J7MN-25-12E5 1 0.32 16 7.5 11 - 16 208 50 J7MN-25-16 1 0.32 20 - 14 - 20 260 50 J7MN-25-20 1 0.32 22 - 17 - 22 286 50 J7MN-25-22 1 0.32 25 11 20 - 25 325 50 J7MN-25-25 1 0.32 25 11 18 - 25 325 50 J7MN-50-25 1 0.96 32 15 22 - 32 416 50 J7MN-50-32 1 0.96 40 18.5 28 - 40 520 50 J7MN-50-40 1 0.96 45 - 36 - 45 585 50 J7MN-50-45 1 0.96 50 22 40 - 50 650 50 J7MN-50-50 1 0.96 63 30 45 - 63 819 50 J7MN-100-63 1 2.1 75 37 57 - 75 975 50 J7MN-100-75 1 2.1 90 - 70 - 90 1170 50 J7MN-100-90 1 2.1 100 45 80 - 100*2 1235 50 J7MN-100-100 1 2.1 In A Circuit-Breakers J7MN-25 Circuit-Breakers J7MN-50 Circuit-Breakers J7MN-100 *1) Recommended values for standard motors *2) max. motor current 95A H-72 Motor Protection Circuit Breaker (MPCB) J7MN Accessories Description Version for circuit breaker pcs. Weight approx. kg/pcs. J73MN-11F 10 0.02 J73MN-11S 10 0.03 J73MN-T-11S 1 0.07 Type Pack Transverse auxiliary contact block Contact block 1NO + 1NC all Auxiliary contact block for left hand side mounting (max 1pc. per circuit breaker) Contact block 1NO + 1NC 9 mm all Signalling switch for left hand side mounting (max 1pc. per circuit breaker) Signalling switch 1NO + 1NC each Individual tripped and short-circuit signalling J7MN-25 J7MN-50 Auxiliary releases for right hand side mounting (max 1pc. per circuit breaker) AC 60 Hz 240 V all J74MN-U-N1 1 0.12 50/60 Hz Shunt release Trips the circuit-breaker 100% ON when the release coil 210-240 V energized. 50/60 Hz, DC 5 sec ON 190-330 V all J74MN-S-N2 1 0.11 for circuit breaker Type Pack pcs. Weight approx. kg/pcs. LVSG Undervoltage release AC 50 Hz Trips the circuit-breaker 230 V when the voltage is interrupted. Prevents the motor from being restarted accidentally when the voltage is restored, suitable for EMERGENCY STOP acc. to VDE 0113 Enclosures and Front Plates Description Version Front Plates for actuation of circuit-breakers J7MN-12 in any enclosure protection degree IP55 J74MN-P12 1 0.08 Moulded plastic front for actuation of circuit-breakers J7MN-25 J7MN-50 plate with rotary operat- in any enclosure protection degree IP55 ing mechanism lockable J74MN-P25 1 0.08 J7MN-25 J74MN-PH 1 0.12 J7MN-12 J74MN-PF12 1 0.27 Moulded plastic front plate with actuator diaphragm and holder for circuit breaker Holder for front plate J74MN-P25 Holder is mounted on front plate, circuit-breaker (with accessories) is snapped on Moulded plastic enclose with actuator diaphragm knockouts for J7MN-25 sealable protection degree IP55 with N- and PE- terminal (+ aux. contact + release) Enclosures Motor Protection Circuit Breaker (MPCB) J7MN H-73 Description Version Moulded plastic enclose with rotary operating mechanism knockouts for J7MN-25 lockable protection degree IP55 with N- and PE- terminal (+ aux. contact + release) for circuit breaker J7MN-25 Type J74MN-PF25 Pack pcs. Weight approx. kg/pcs. 1 0.30 Door-coupling mechanisms The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and a extension shaft (5 mm x 5 mm). The door-coupling rotary operating mechanisms are designed for degree of protection IP 65. The door locking device prevents accidental opening of the cubicle door in the ON position of the circuit-breaker. The OFF position can be locked with up to 3 padlocks. extension shaft 330 mm with supporting bracket J7MN-25 to J7MN-50 J74MN-DC-B 1 0.3 extension shaft 330 mm Emergency-Stop Door-coupling rotary with supporting bracket mechanism red/yellow J7MN-25 to J7MN-50 J74MN-DC-RY 1 0.3 Description for circuit breaker Type Pack pcs. Weight approx. kg/pcs. 1 1 1 1 0.03 0.05 0.07 0.10 Door-coupling rotary mechanism black Busbars Version Insulated 3-phase busbar systems For feeding several modular circuit-breakers on standard mounting rails, insulated, shock-protected. Rated operational voltage max. 690 V for 2 circuit-breakers 3-phase busbars modular spacing 45 mm for 3 circuit-breakers for 4 circuit-breakers for 5 circuit-breakers J7MN-12 J7MN-25 J74MN-L3-1/2 J74MN-L3-1/3 J74MN-L3-1/4 J74MN-L3-1/5 For connecting the 3-phase busbars from circuit-breakers different sizes. Clamping together J7MN-12 and J7MN-25 circuit-breakers is not possible due to the different modular spacings and the different heights of the terminals. Line side terminal 3-pole, connection from top Conductor cross-section solid or stranded 6- 25 mm with ferrule 4-16 mm J7MN-12 J7MN-25 J74MN-TC12 J74MN-TC25 1 1 0.04 0.04 Shroud for unused terminals J7MN-12 J7MN-25 J74MN-DS 20 - for circuit breaker Type Pack pcs. Weight approx. kg/pcs. J74MN-HU 10 0.05 J74MN-VD-12 J74MN-VD-25 10 10 - J74MN-TB25 J74MN-TB100 1 1 0.12 0.15 Mounting Parts for Fuseless Load Feeders Description Version DIN-rail adapters Adapter for mechanical fixing of circuit-breaker and contactor 35 mm-DIN-rail (DIN EN50022) or screw mounting J7MN... Link modules for electrical connection between circuit-breaker and contactor Link module up to 20 A up to 32 A J7MN... Terminal block with increased creepage distances and clearances acc. to cULus Type E" Terminal block H-74 up to 600 V acc. to UL 489 J7MN-25 not for transverse aux. contact J7MN-100 block Motor Protection Circuit Breaker (MPCB) J7MN Specifications Engineering data and Characteristics Components for Fuseless Load Feeders, DIN-Rail Mounting Motor 3~400V kW Setting range A Circuit-breaker page 72 Type Contactor 220-230V 50Hz Type Link module Type DIN-rail adapter Type - 0.11- 0.16 J7MN-25-E16 J7KN-10-10 230 J74MN-VD-12 J74MN-HU - 0.14- 0.2 J7MN-25-E2 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.06 0.18- 0.25 J7MN-25-E25 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.09 0.22- 0.32 J7MN-25-E32 J7KN-10-10 230 J74MN-VD-12 J74MN-HU - 0.28- 0.4 J7MN-25-E4 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.12 0.35- 0.5 J7MN-25-E5 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.18 0.45- 0.63 J7MN-25-E63 J7KN-10-10 230 J74MN-VD-12 J74MN-HU - 0.55- 0.8 J7MN-25-E8 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.25 0.7- 1 J7MN-25-1 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.37 0.9- 1.25 J7MN-25-1E25 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.55 1.1- 1.6 J7MN-25-1E6 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 0.75 1.4- 2 J7MN-25-2 J7KN-10-10 230 J74MN-VD-12 J74MN-HU - 1.8- 2.5 J7MN-25-2E5 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 1.1 2.2- 3.2 J7MN-25-3E2 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 1.5 2.8- 4 J7MN-25-4 J7KN-10-10 230 J74MN-VD-12 J74MN-HU - 3.5- 5 J7MN-25-5 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 2.2 4.5- 6.3 J7MN-25-6E3 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 3 5.5- 8 J7MN-25-8 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 4 7- 10 J7MN-25-10 J7KN-10-10 230 J74MN-VD-12 J74MN-HU 5.5 9- 12.5 J7MN-25-12E5 J7KN-14-10 230 J74MN-VD-12 J74MN-HU 7.5 11- 16 J7MN-25-16 J7KN-18-10 230 J74MN-VD-12 J74MN-HU - 14- 20 J7MN-25-20 J7KN-22-10 230 J74MN-VD-25 J74MN-HU - 17- 22 J7MN-25-22 J7KN-22-10 230 J74MN-VD-25 J74MN-HU 11 20- 25 J7MN-25-25 J7KN-22-10 230 J74MN-VD-25 J74MN-HU Motor Protection Circuit Breaker (MPCB) J7MN LVSG Type of coordination 1" 3 x 415 V 10 kA (other conditions on request) H-75 Technical Data according to IEC/EN 60947-1, 60947-2, 60947-4-1 and VDE 0660 If the short-circuit current exceeds the rated short-circuit breaking capacity of the circuit-breaker specified in the tables at the installation point, a back-up fuse is to be used. This table shows the rated ultimate short-circuit breaking capacity Icu and the rated service short-circuit breaking capacity Ics of the J7MN circuit-breakers with different operational voltages as a function of the rated current In of the circuit-breakers. The maximum rated current for the back-up fuse is specified in the tables. These fuses are only suitable for the short-circuit-currents as indicated on the fuses. The circuit-breakers can be fed at the top or bottom supply terminals without any reduction of the rated data. Circuitbreaker Rated current In up to AC 240V*1) Type A Icu kA J7MN-12 0.16 to 0.8 100 up to AC 400V*1) up to AC 415V*2) kA Icu max. fuse (gL/gG) A kA 100 -- 100 Ics up to AC 440V*1) up to AC 460V*2) kA Icu max. fuse (gL/gG) A kA 100 -- 100 Ics up to AC 500V*1) up to AC 525V*2) kA Icu max. fuse (gL/gG) A kA 100 -- 100 Ics up to AC 690V*1) kA Icu max. fuse (gL/gG) A kA kA max. fuse (gL/gG) A 100 -- 100 100 -- Ics Ics 1 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 1.25 100 100 -- 100 100 -- 100 100 -- 100 100 -- 2 2 20 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 2 2 20 2 100 100 -- 100 100 -- 100 100 -- 10 10 35 2 2 35 2.5 100 100 -- 100 100 -- 100 100 -- 10 10 35 2 2 35 3.2 100 100 -- 100 100 -- 10 10 40 3 3 40 2 2 40 4 100 100 -- 100 100 -- 10 10 40 3 3 40 2 2 40 5 100 100 -- 100 100 -- 10 10 50 3 3 50 2 2 50 6.3 100 100 -- 100 100 -- 10 10 50 3 3 50 2 2 50 8 100 100 -- 50 12.5 80*3) 10 10 63 3 3 63 2 2 63 10 100 100 -- 50 12.5 80*3) 10 10 63 3 3 63 2 2 63 12 100 100 -- 50 12.5 80*3) 10 10 80 3 3 80 2 2 80 J7MN-25 0.16 to 1.25 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 2 100 100 -- 100 100 -- 100 100 -- 100 100 -- 8 8 25 2.5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 8 8 25 3.2 100 100 -- 100 100 -- 100 100 -- 100 100 -- 8 8 32 4 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 3 32 5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 3 32 6.3 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 3 50 8 100 100 -- 100 100 -- 50 25 63*3 42 21 63 6 3 50 10 100 100 -- 100 100 -- 50 25 80*3 42 21 63 6 3 50 12.5 100 100 -- 100 100 -- 50 25 80*3 42 21 80 6 3 63 16 100 100 -- 50 25 100*3) 20 10 80 10 5 80 4 2 63 20 100 100 -- 50 25 125*3) 20 10 80 10 5 80 4 2 63 22 100 100 -- 50 25 125*3) 20 10 100 10 5 80 4 2 63 25 100 100 -- 50 25 125*3) 20 10 100 10 5 80 4 2 63 J7MN-50 25 100 100 -- 50 25 125*3) 30 15 100 12 6 80 5 3 63 32 100 100 -- 50 25 125*3) 30 15 125 10 5 100 4 2 63 40 100 100 -- 50 25 160*3) 30 15 125 10 5 100 4 2 63 45 100 100 -- 50 25 160*3) 30 15 125 10 5 100 4 2 63 50 100 100 -- 50 25 160*3) 30 15 125 10 5 100 4 2 80 J7MN-100 63 100 100 -- 50 25 160*3) 40 20 160 12 6 125 6 3 80 75 100 100 -- 50 25 160*3) 40 20 160 8 4 125 5 3 100 90 100 100 -- 50 25 160*3) 40 20 160 8 4 125 5 3 125 100 100 100 -- 50 25 160*3) 40 20 160 8 4 125 5 3 125 *1) 10% overvoltage *2) 5% overvoltage *3) Back-up fuse required if short-circuit current at installation point > 50 kA -- No back-up fuse required. H-76 Motor Protection Circuit Breaker (MPCB) J7MN Technical Data according to IEC/EN 60947-1, 60947-2, 60947-4-1 and VDE 0660 Main Circuit Type J7MN-12 J7MN-25 J7MN-50 J7MN-100 Number of poles 3 3 3 3 12 25 50 100 - A Max. rated current Inmax (=max. rated operational current Ie) Permissible ambient temperature Storage/transport C -50 to +80 Operation C -20 to +70*1) +60 C % 100 +70 C % 87 Permissible rated current at temperature inside enclosure of: +60 C % 100 +70 C % 87 Rated operational voltage Ue V 690*2) Rated frequency Hz 50/60 Rated insulation voltage Ui V 690 Rated impulse withstand voltage Uimp kV 6 Permissible rated current at temperature inside cubicle of: Circuit-breaker inside enclosure Utilization category IEC 60 947-2 (circuit-breaker) A IEC 60 947-4-1 (motor starter) Class AC-3 acc. to IEC 60 947-4-1 10 1 conducting path DC 150 V kA 10 2 conducting paths in series DC 300 V kA 10 3 conducting paths in series DC 450 V Power loss Pv per circuit-breaker dependent on rated current In (upper setting range) R per conducting path = P/(I x 3) kA 10 In -> to 1.25 A W 5 - - In -> 1.6 to 6.3 A W 6 - - - In -> 8 to 12 A W 7 - - - In -> 1 to 6.3 A W - 6 - - In -> 8 to 16 A W - 7 - - In -> 20 to 25 A W - 8 - - In -> to 25 A W - - 12 - In -> 32 A W - - 15 - In -> 40 to 50 A W - - 20 - In -> to 63 A W - - - 20 In -> 75 to 90 A W - - - 30 In -> to 100 A W - - - 38 Shock resistance acc. to IEC 68 Part 2-27 g 25 25 25 25 Degree of protection acc. to IEC 60 529 IP 20 IP 20 IP 20*3) IP 20*3) Shock hazard protection acc. to DIN VDE 0106 Part 100 safe against finger touch Temperature compensation acc. to IEC 60 947-4-1 -20 to +60 Phase failure sensitivity acc. to IEC 60 947-4-1 Explosion protection acc. to EC Directive 94191 EC yes*4) Isolator characteristics acc. to IEC 60 947-3 yes Main and EM. STOP switch characteristics acc. to IEC 60 204-1 (VDE 0113) yes*5) Safe isolation between main and auxiliary circuits acc. to DIN VDE 0106 Part 101 Mechanical endurance C yes up to 400 V + 10 % yes up to 415 V+ 5 % yes operating cycles 100 000 100 000 50 000 50 000 100 000 100 000 25 000 25 000 15 15 15 15 Electrical endurance Max. operating frequency per hour (motor starts) Permissible mounting position LVSG DC short-circuit breaking capacity (time constant t = 5 ms) 1/h any. acc. to IEC 60 447 start command "I" right-hand side or top *1) Over +60C current reduction *2) 500 V with moulded-plastic enclosure *3) Terminal compartment IP00 *4) KEMA-test certification on request *5) With appropriate accessories Motor Protection Circuit Breaker (MPCB) J7MN H-77 Technical Data according to IEC/EN 60947-1, 60947-2, 60947-4-1 and VDE 0660 Conductor cross-sections for main Circuit Type J7MN-12 J7MN-25 J7MN-50 J7MN-100 Terminal type Screw-type Screw-type Box terminal Box terminal Terminal screw Tightening torque Pozidriv size 2 Pozidriv size 2 Pozidriv size 2 Allen screw 4 mm Nm 0.8 to 1.2 2 to 2.5 3 to 4.5 4 to 6 mm 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 16) 2 x (2.5 to 16) mm 2 x (0.75 to 2.5) 2 x (2.5 to 6) - - mm 1 x (0.5 to 4) Conductor cross-sections solid finely stranded with end ferrule mm 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 16) 2 x (2.5 to 35) mm 2 x (0.75 to 2.5) 2 x (2.5 to 6) 1 x (0.75 to 25) 1 x (2.5 to 50) mm 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 25) 2 x (10 to 50) mm 2 x (0.75 to 2.5) 2 x (2.5 to 6) 1 x (0.75 to 35) 1 x (10 to 70) mm stranded AWG-wires, solid or stranded conductor bar (number x width x thick) 1 x (1 to 10) mm 1 x (0.5 to 4) 1 x (1 to 10) AWG 2 x (18 to 14) 2 x (14 to 10) 2 x (18 to 3) 2 x (10 to 1/0) AWG - - 1 x (18 to 2) 1 x (10 to 2/0) mm - - 2 x (6 x 9 x 0.8) 2 x (6 x 9 x 0.8) mm - - - 18 x 10 mm - - - up to 2 x 70 Technical Data according to IEC/EN 60947-1, 60947-2, 60947-4-1 and VDE 0660 Auxiliary switches Switching capacity Control voltage Front transverse auxiliary switch with 1 NO + 1 NC Rated operational voltage Ue AC Rated operational current Ie/AC-15 Rated operational current Ie/AC-12 Ith Rated operational voltage Ue DC L/R 200 ms Rated operational current Ie/DC-13 V 24 230 A 2 0.5 A 2.5 2.5 V 24 48 60 A 1 0.3 0.15 Lateral auxiliary switch and signalling switch Rated operational voltage Ue AC Rated operational current Ie/AC-15 Rated operational current Ie/AC-12 Ith Rated operational voltage Ue DC L/R 200 ms Rated operational current Ie/DC-13 Undervoltage release Power consumption Response voltage Shunt release V 24 230 400 690 A 6 6 3 1 A 10 10 10 10 V 24 110 220 440 A 2 0.5 0.25 0.1 during pick-up VA/W 20.2/13 uninterrupted duty VA/W 7.2/2.4 trip V 0.7 to 0.35 x Us pick-up V 0.85 to 1.1 x Us Max. opening time ms 20 Power consumption during pick-up AC VA/W 20.2/13 DC W 13 to 80 Response voltage acc. to IEC 60 947-1, trip V 0.7 to 1.1 x Us Max. opening time ms 20 A 10 Short-circuit protection for auxiliary and control circuits Fuse gL/gG Miniature circuit breaker C-characteristic A solid mm finely stranded with ferrule mm 2 x (0.5 to 1.5) / 2 x (0.75 to 2.5) stranded mm 2 x (0.5 to 1.5) / 2 x (0.75 to 2.5) AWG-wires, solid or stranded AWG 2 x (18 to 14) *1) Prospective short-circuit current < 0.4 kA. H-78 6*1) Screw-type Pozidriv size 2 Conductor cross-sections for auxiliary and control circuits Motor Protection Circuit Breaker (MPCB) J7MN 2 x (0.5 to 1.5) / 2 x (0.75 to 2.5) Description J7MN circuit-breakers are compact, current-limiting circuit-breakers which are optimised for load feeders. The circuit-breakers are used for switching and protecting three-phase induction motors of up to 18,5 kW at AC 400 V and for loads with rated currents of up to 40 A. Construction Short-circuit protection The short-circuit releases of J7MN circuit-breakers disconnect the faulty load feeder from the system in the event of a short circuit and thus prevent any further damage. Circuit-breakers with a short-circuit breaking capacity of 50 kA or 100 kA at a voltage of 400 V AC are practically short-circuit-proof at this voltage, as higher short-circuit currents are not usually encountered at the installation point. The circuit-breakers are available in three sizes: J7MN-12 overall width 45 mm. Max. rated current 12 A. Suitable for 3-phase induction motors of up to 5.5 kW at voltages of 400 V AC. J7MN-25 overall width 45 mm. Max. rated current 25 A. Suitable for 3-phase induction motors of up to 11 kW at voltages of 400 V AC. Back-up fuses are only necessary if the short-circuit current at the installation point exceeds the rated ultimate short-circuit breaking capacity of the circuit-breakers. J7MN-50 overall width 55 mm. Max. rated current 40 A. Suitable for 3-phase induction motors of up to 18,5 kW at voltages of 400 V AC. Motor protection The tripping characteristics of J7MN circuit-breakers are designed mainly to protect three-phase induction motors. The circuit-breakers are therefore also referred to as motor circuit-breakers. The current of the motor to be protected is set with the aid of the scale. Releases Circuit-breakers J7MN are equipped with bimetallic-based, inversetime delayed overload releases and with instantaneous overcurrent releases (electromagnetic short-circuit releases). Circuit-breakers with thermal overload releases are normally designed in accordance with release Class 10. The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value 13 times the rated current and thus enable trouble-free start-up of motors. Line protection The scale cover can be sealed to prevent unauthorized adjustments to the set current. Operating mechanisms circuit-breakers J7MN-12 are actuated via a switch operating mechanism and circuit-breakers J7MN-25 and J7MN-50 via a rotary operating mechanism. If the circuit-breaker trips, the rotary operating mechanism switches to the tripped position to indicate this. Before the circuit-breaker is reclosed, the rotary operating mechanism must be reset to the 0 position by hand, in order to prevent the former from closing by mistake before the fault has been cleared. In the case of circuit-breakers with rotary operating mechanisms, there is an electrical signal via a signalling switch to indicate that the circuit-breaker has tripped. J7MN circuit-breakers for motor protection are also suitable for line protection. In order to prevent premature tripping due to phase failure sensitivity, the three conducting paths must always be uniformly loaded. The conducting paths must be connected in series in the case of single-phase loads. The J7MN circuit-breakers meet the isolation conditions of IEC 60 947-3 as well as the additional test conditions for circuitbreakers with isolation characteristics specified in IEC 60 947-2. Taking IEC 60 204-1 into consideration, they can thus be implemented as main and EMERGENCY STOP switches. Door-coupling rotary operating mechanism do not fulfil the isolation characteristics specified in IEC 60 947-2. Door-coupling rotary operating mechanism according isolation characteristics specified in IEC 60 947-2 on request. LVSG All operating mechanisms can be locked in the 0 position with a padlock (shackle diameter 3.5 to 4.5 mm). The J7MN circuit-breakers fulfil the isolation characteristics specified in IEC 60 947-2. Operating conditions Circuit-breakers J7MN are suitable for use in any climate. They are designed for operation in enclosed rooms under normal conditions (e. g. no dust, corrosive vapours or harmful gases). Suitable enclosures must be provided for installation in dusty or damp rooms. Circuit-breakers J7MN can also be fed from below. The standards in accordance with which the circuit-breakers are constructed, the permissible ambient temperatures, the maximum making and breaking capacities, the tripping currents and other boundary conditions can be found in the technical data and tripping characteristics. Since the operational currents, starting currents and current peaks vary as a result of the inrush current, even in the case of motors with identical output ratings, the values specified for these output ratings in the selection tables are intended as a guide only. The specific rated and start-up data of the motor to be protected is always paramount to the choice of the most suitable circuit-breaker. In order to prevent premature tripping due to phase failure sensitivity, the circuit-breakers should always be connected in such a way that current flows through all three main conducting paths. Motor Protection Circuit Breaker (MPCB) J7MN H-79 Characteristics The time/current characteristic, the current limiting characteristics and the It characteristics were determined in accordance with DIN VDE 0660 and IEC 60 947. Opening Time The tripping characteristic of the inverse-time delayed overload releases (thermal overload releases or 'a' releases) for DC and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic. The characteristics apply to the cold state. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25 %. Under normal operating conditions, all three poles of the device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase or DC loads. With 3-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is 20 % and thus in accordance with DIN VDE 0165. The tripping characteristics for the instantaneous, electromagnetic overcurrent releases (short-circuit releases or 'n' releases) are based on the rated current In, which is also the maximum value of the setting range for circuit-breakers with adjustable overload releases. If the current is set to a lower value, the tripping current of the 'n' release is increased by a corresponding factor. 3-pole load Class 10 2-pole load Class 10 The characteristics of the electromagnetic overcurrent releases apply to frequencies of 50/60 Hz. Appropriate correction factors must be used for lower frequencies up to 16 2/3 Hz, for higher frequencies up to 400 Hz and for DC. The characteristic shown here is a schematic representation of circuit-breakers for all ranges. Time/current characteristics, current limiting characteristics and It characteristics are available on request. Current Wiring diagrams Circuit-breaker Transverse auxiliary contact block Lateral auxiliary contact block J7MN J73MN-11F J73MN-11S Signalling switch Undervoltage release Shunt release J73MN-T-11S J74MN-U J74MN-S H-80 Motor Protection Circuit Breaker (MPCB) J7MN Dimensions Circuit-breaker J7MN-12 Circuit-breaker J7MN-25 Circuit-breaker J7MN-50 1) 2) 3) 4) 7) 8) 9) Lateral aux. contact Signalling contact Auxiliary release Transverse aux. contact Mounting holes 35mm DIN-rail 35mm DIN-rail 15mm high or 75mm DIN-rail 10) 4mm hexagon socket screw 11) Lockable in 0-position with shackle diameter max.5mm 1) 2) 3) 4) 7) 8) 9) Lateral aux. contact Signalling contact Auxiliary release Transverse aux. contact Mounting holes 35mm DIN-rail 35mm DIN-rail 15mm high or 75mm DIN-rail 10) 4mm hexagon socket screw 11) Lockable in 0-position with shackle diameter max.5mm Motor Protection Circuit Breaker (MPCB) J7MN H-81 LVSG Circuit-breaker J7MN-100 Moulded plastic front plate J74MN-P12 Moulded plastic front plate J74MN-P25 Moulded plastic enclosure J74MN-PF12 Door-coupling rotary operating mechanism J74MN-DC 1) Max. for shackle diameter for padlock 8 mm 3-phase busbar J74MN-L3-#/# for J7MN-12 and J7MN-25, modular spacing 45 mm 3-phase line-side terminal J74MN-TC12 and J74MN-TC25 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J508-E2-02 H-82 In the interest of product improvement, specifications are subject to change without notice. Motor Protection Circuit Breaker (MPCB) J7MN Appendix Precautions Notice Use under rated condition, otherwise contactors will not only cause malfunction, but also cause a fire or damage the contactor. Do not use a contactor or thermal relay which has been dropped or dismantled. Doing so may cause malfunction or a fire. Life period of contactor depends on the operating application. Please check the electrical life under real application in advance. If you continue to use malfunctioning contactor, a fire or breakdown may occur. Make sure to shut off power supply to contactors before wiring or replacing. Do not operate the actuator of a contactor manually. Doing so may cause contact welding by chattering or burn out by arc. Do not miss-wire or miss-charge the power supply, otherwise the contactor does not work correctly. Do not operate in places with explosive or flammable gas, otherwise a fire or explosion may occur by arc or heating from contactor. Make sure to use the circuit well considered about safety, in case there is any possibility to cause secondary disaster by contact trouble (welding, faulty contact). Do not supply short-circuit current to electromagnetic switch (contactor with thermal relay). Doing so may result failure in heater of thermal relay. Please use short-circuit protection like fuse or protective circuit breaker. Unless otherwise stated in the catalogue, modifications, especially those of stated values, sizes and weights are subject to alternation. Diagrams and tables are subject to alternation and not to be regarded as binding drawings. General use Circuit design Unexpected malfunction may occur in real application. Please carry out as many tests as possible. Supplied voltage waveform for input Ratings in this catalogue measured under the condition according to IEC unless otherwise specified. In cases of check by real application, please carry out the test under the same condition as expected in the actual application. Make sure to apply and remove the voltage instantly. Do not use under the condition that the coil voltage waveform increases or decreases gradually. Selection In case of DC contactor use (input voltage ripple) Coil specification Please use DC contactor input voltage with a ripple ratio less than 5%. Excessive ripple (pulsating current) may cause contact welding. Please select suitable coil to circuit design, otherwise malfunction may occur or coil may have a burn out by overvoltage etc. Fluctuation of input voltage Type Make sure to supply sufficient voltage to actuate contactors properly. Continuous supply of insufficient voltage results in excessive heating and may cause burn out of coil. Please check contact ratings, switching capacity, thermal characteristics etc. when selecting product type. Thermal relay Motor current differs by supplier, type, number of poles, frequency. Please confirm operational current level. Coil surge suppressor Coil surge suppressor type should be selected by contactor type, auxiliary relay type and applied voltage. Make sure to use defined each contactor. In case of installing coil surge suppressor, please check the actual circuit because the release time will be delayed. Electrical life expectancy Electrical life expectancy tests in this catalogue are based on IEC. Maximum applied voltage Do not supply the voltage over the maximum rated voltage, otherwise burn out or insulation failure may occur. The temperature inside control panel has much influence to the coil temperature, so make sure not to exceed the specified value in the catalogue. Basically rated voltage should be supplied to coil. To supply higher voltage than rated would result in shorter electrical life, even if it is lower than the maximum rated voltage. Reverse Make sure to use reversible contactors for reverse operation. Make sure to use interlock device in reverse operation by two contactors, otherwise short circuit current may burn out or give damage to contactors and motors. Appendix H-83 LVSG Correct use Installation Operation ambience Mounting Dust Make sure to use specified wire size, mounting screw size, mounting screw number, and DIN rail size. Dust on the surface of the contacts could result in contact malfunctioning. Take countermeasure in excessive dusty surrounding. Tightening Screw Temperature, humidity Tighten each screw securely by specified tightening torque. Loose tightening may cause a fire by excessive heating. Use contactors within the temperature and humidity conditions specified in datasheet. To use or store contactor in excessive temperature or humidity may result in malfunction of contact by organic film composed by sulfication and oxidation on the surface of the contacts. Combination Wrong-combinations may result in damage to contactors. Use contactors within the temperature and humidity conditions specified in the datasheet, to prevent contactors from insulation resistance failure by condensation or insulation resistance deterioration by tracking. Mounting direction Gas Some products have a defined specific mounting direction. Please refer to datasheet before use. NH3, H2S, SO2, CI2, Si and NO2 have bad effects on a contactor. With these gases, a corrosive metal film ist generated on the surface of the contacts and could result in contact malfunctioning. Use a contactor in low humidity and no corrosive gas surroundings. Please use only OMRON product combinations in case of thermal relay, timer block and auxiliary contact block etc. Oil Do not use a contactor in places where oil is sprayed onto the contactor. It will cause cracks on polymer parts. Shock and vibration Do not use a contactor in places where there is excessive shock or vibration. It may cause malfunctioning. Storage Store contactors in a place with no direct sunshine or ultraviolet rays. It will cause crack on polymer parts. When contactors are to be stored for a long time, they must be stored with care. Though it generally depends where contactors are stored, deterioration of contacts may occur after long storage. Please check the characteristics before use after long time storage. H-84 Appendix European Standards IEC 947, EN 60947 European Standards for Low-Voltage Switchgear For Europe and most other industrial countries of the world, the new IEC 947 and EN 60 947 specifications for low-voltage switchgear have unified the regulations which previously varied from nation to nation. This required the introduction of new terms, and new test methods and utilization categories. The new specifications are aimed primarily at manufacturers. However, the user also will come across new technical terms and data in the manufacturers' catalogues and on the devices themselves which are important for the selection and application of the devices. The present paper deals with the currently published specifications. Further specifications and supplements are in preparation. Since 1993, all low-voltage switchgear purchased in Europe had to satisfy the EN 60 947 European Standard. Installations in existence prior to 1993 are not affected by the standard and need not to be refitted with new devices. Devices constructed and tested to the IEC standards and EN standards can be used worldwide, with the exception of the USA and Canada. In these countries UL and CSA specifications continue to apply. Switchgear which conforms to IEC 947 and EN 60 947 and which has, in addition, UL- and CSA approvals, in the meantime has entered the market. Such `world market' devices offer the advantage that they can be used throughout the world, including the USA and Canada. IEC 947-1 IEC 947-2 General rules Circuit-breakers IEC 947-3 IEC 947-4-1 IEC 947-5-1 IEC 947-6-1 IEC 947-6-2 Switches, disconnectors, switch-disconnectors and fuse-combination units Connectors and motor-starters Control circuit devices and switching elements Multiple function equipment, Automatic transfer switching equipment Multiple function equipment, Control and protective switching devices (or equipment) (CPS) Ancillary equipment IEC 947-7-1 LVSG IEC 947 Conditions for compliance with Type 1 coordination (Extract from IEC 947-4-1) Conditions for compliance with Type 2 coordination (Extract from IEC 947-4-1) - The contactor or the starter must not endanger personnel or equipment in the event of a short circuit - The contactor or the starter does not need to be suitable for continued operation without repair and replacement of parts - The contactor or the starter must not endanger personnel or equipment in the event of a short circuit - The contactor or the starter must be suitable for further use - No damage may occur to the overload relay or other parts, with the exception of welding of the contactor or starter contacts, provided they can be separated easily without any significant deformation (e.g. using a screwdriver) - Damage to the contactor and the overload relay is permissible Rated conditional short-circuit current lq - The rated conditional short-circuit current lq indicates the max. shortcircuit breaking capacity of the starter Rated operation current le - The rated operational current le for the starter is the current when the starter is in the On position Rated uninterrupted current lu (to IEC 947-1) - The rated uninterrupted current lu of a unit is a current, specified by the manufacturer, which the unit can carry without interruption Appendix H-85 Overview The following table shows in summarized form both the previous and the new IEC, EN and DIN VDE standards. Previous specification New specification IEC DIN VDE IEC EN 60947 DIN VDE Content - - 947-1 60947-1 0660, Part 100 Low-voltage switchgear, General rules 157 0660, Part 101 947-2 60947-2 0660, Part 101 Low-voltage switchgear, Circuit-breakers 406 0660, Part 107 947-3 60947-3 0660, Part 107 Low-voltage switchgear, Switches, Disconnectors, Switch-disconnectors, Fuse-combination units 158 292-1 292-2 292-3 0660, Part 102 0660, Part 104 0660, Part 106 0660, Part 301 947-4-1 60947-4-1 0660, Part 102 Low-voltage switchgear, Control circuit devices and switching elements 337 0660 Part 200 to Part 205 947-5-1 60947-5-1 0660, Part 200 Low-voltage switchgear, Multiple-function equipment, Automatic transfer switching equipment - - 947-6-1 60947-6-1 0660, Part 114 Low-voltage switchgear, Multiple-function equipment, Control and protective switching devices (CPS) - 0611 Part 1 and 2 947-7-1 60947-7-1 0611, Part 1 Low-voltage switchgear, Ancillary equipment (e.g. terminal blocks) Switches, disconnectors, switch-disconnectors and fuse combination units (IEC 947-3, EN 60947-3) These devices must now be labelled with the product function designated by the manufacturer. This means placing clearly visible symbols on the device itself. Devices with an isolating function are subject to special safety requirements. They must for example have greater creepage distances and clearances across the opened contacts than is necessary for other devices. Device functions and corresponding symbols Making/breaking Isolating Making/breaking + isolating Switch Disconnector Switch-disconnector Switch-fuse Disconnector-fuse Switch-disconnector-fuse Fuse-switch Fuse-disconnector Fuse switch-disconnector OMRON equipment is designed for the world's markets It is manufactured and tested in accordance with national and international specifications, the most important of which are listed below: IEC 947-..., EN 60947: IEC 664: IEC364: IEC 204-..., EN 60204-...: DIN VDE 0105: IEC 536: H-86 Low-voltage switch gear and control gear Insulation co-ordination including clearances and creepage distances for equipment Electrical installations of buildings Electrical equipment of industrial machines Operation of electrical power installations Protection against electric shock Appendix Utilization categories for contactors to IEC 947-4-1 and EN 60947 Type of current AC Typical examples of application I = current made, Ic = current broken Utilization Ie = rated operational current category U = voltage before make Ue = rated operational voltage Ur = recovery voltage Verification of electrical endurance Make Ie A Verification of rated making and breaking capacities Break I Ie U Ue cos Make Ic Ie - Ur cos Ue Ie Break U Ue cos A I Ie Ic Ie - cos 0.8 Ur Ue AC-1 Non-inductive or slightly inductive loads, resistance All values furnaces 1 1 0.95 1 1 0.95 All values 1.5 1.05 0.8 1.5 1.05 AC-2 Slip-ring motors: starting, switching off 2.5 1 0.65 2.5 1 0.65 All values 4 1.05 0.65 4 1.05 0.65 AC-3 Squirrel-cage motors: starting, switching off motors Ie 17 Ie > 17 during running4 6 6 1 1 0.65 0.35 1 1 0.17 0.17 0.65 0.35 Ie 100 Ie > 100 10 10 1.05 1.05 0.45 0.35 8 8 1.05 1.05 0.45 0.35 AC-4 Squirrel-cage motors: starting, plugging, inching Ie 17 Ie > 17 6 6 1 1 0.65 0.35 6 6 1 1 0.65 0.35 Ie 100 Ie > 100 12 12 1.05 1.05 0.45 0.35 10 10 1.05 1.05 0.45 0.35 AC-5A Switching of electric discharge lamp controls - - - - - - - - 3.0 1.05 0.45 3.0 1.05 0.45 AC-5B Switching of incandescent lamps - - - - - - - - 1.52 1.05 2 1.52 1.05 2 AC-6A3 Switching of transformers As given by the manufacturer - - - - - - - AC-6B3 Switching of capacitor banks As given by the manufacturer - - - - - - - AC-7A Slightly inductive loads in household appliances and As given by the manufacturer similar applications - 1.5 1.05 0.8 1.5 1.05 0.8 AC-7B Motor-loads for household applications As given by the manufacturer - 8.0 1.05 1 8.0 1.05 1 AC-8A Hermetic refrigerant compressor motor control with As given by the manufacturer manual resetting of overload releases5 - 6.0 1.05 1 6.0 1.05 1 AC-8B Hermetic refrigerant compressor motor control with As given by the manufacturer automatic resetting of overload releases5 - 6.0 1.05 1 6.0 1.05 1 Ie U Ue L/R Ic Ie Ur L/R ms - Ue ms All values ) ) ) ) ) U Ue L/R ms Ic Ie - Ue ms A I Ie DC-1 Non-inductive or slightly inductive loads, resistance All values furnaces 1 1 1 1 1 1 All values 1.5 1.05 1 1.5 1.05 1 DC-3 Shunt motors: starting, plugging, inching, dynamic braking All values 2.5 1 2 2.5 1 2 All values 4 1.05 2.5 4 1.05 2.5 DC-5 Series motors: starting, plugging, inching, dynamic All values braking 2.5 1 7.5 2.5 1 7.5 All values 4 1.05 15 4 1.05 15 - 1.5 2 ) 2 1.5 2 ) 1.05 2 A DC DC-6 Switching of incandescent lamps - - - - - Note 1: cos = 0.45 for Ie 100 A; cos = 0.35 for Ie > 100 A. 2: The tests are to be carried out with an incandescent light load. 3: The test data are to be derived from the test values for AC-3 or AC-4 according to Table VIIb, EN 60947-4-1. - L/R ) ) I Ie Ie Ur ) - 1.05 ) ) 4: AC-3 category may be used for occasional inching (jogging) or plugging for limited time periods such as machine set-up; during such limited time periods the number of such operations should not exceed five per minute or more than ten in a ten minute period. 5: A hermetic refrigerant compressor motor is a combination consisting of a compressor and a motor, both of which are enclosed in the same housing, with no external shaft or shaft seals, the motor operating in the refrigerant. Utilization categories for control switches to IEC 947-5-1 and EN 60947 Normal conditions of use Abormal conditions of use AC AC-12 Control of resistive and solid state loads as in optocoupler input circuits AC-13 Control of solid state loads with transformer isolation 2 1 0.65 1 1 0.65 10 1.1 0.65 1.1 1.1 0.65 AC-14 Control of small electromagnetic loads ( 72 VA) 6 1 0.3 1 1 0.3 6 1.1 0.7 6 1.1 0.7 AC-15 Control of electromagnetic loads (> 72 VA) 10 1 0.3 1 1 0.3 10 1.1 0.3 10 1.1 0.3 I Ie U Ue t0.95 Ic Ie Ur Ue t0.95 I Ie U Ue t0.95 Ic Ie Ur Ue t0.95 1 1 1 ms 1 1 1 ms - - - - - - 1 1 DC DC-12 Make Control of resistive and solid state loads as in optocoupler input circuits Break Make LVSG Type of current Typical examples of application I = current made, Ic = current broken Ie = rated operational current Ue = rated operational voltage Utilization Ur = recovery voltage category U = voltage before make t0.95 = time in ms to reach 95 % of the steady-state current P = Ue x Ie = rated power consumption in watts Break I Ie U Ue cos Ic Ie Ur Ue cos I Ie U Ue cos Ic Ie Ur Ue cos 1 1 0.9 1 1 0.9 - - - - - - 1 DC-13 Control of electromagnets 1 1 6xP ) 1 1 6xP ) 1.1 1.1 6xP ) 1.1 1.1 6xP1) DC-14 Control of electromagnetic loads having economy resistors in circuits 10 1 15 ms 1 1 15 ms 10 1.1 15 ms 10 1.1 15 ms Note 1: The value "6 x P" results from an empirical relationship which is found to represent most DC magnetic loads to an upper limit of P = 50 W, viz 6 x P = 300 ms. Loads having power consumption greater than 50 W are assumed to consist of smaller loads in parallel. Therefore, 300 ms is to be an upper limit, irrespective of the power consumption value. Utilization categories for switches, disconnectors, switch-disconnectors, and fuse combination units to IEC 947-3 and EN 60947 Type of current AC Typical applications I = current made, Ic = current broken Utilization Ie = rated operational current category U = voltage before make Ue = rated operational voltage Ur = recovery voltage Verification of electrical endurance Make Ie A Verification of switching capacity Break Make Ic Ie Ur Ue cos 1 1 ) 1 1 I Ie U Ue cos Ie Break I Ie U Ue cos Ic Ie Ur Ue cos All values 1 ) 1.05 1 1 ) 1.05 1 A AC-20 A(B)2 Connecting and disconnecting under no-load condiAll values tions 1 ) 1 AC-21 A(B)2 Switching of resistive loads, including moderate overloads All values 1 1 0.95 1 1 0.95 All values 1.5 1.05 0.95 1.5 1.05 0.95 AC-22 A(B)2 Switching of mixed resistive and inductive loads, inAll values cluding moderate overloads 1 1 0.8 1 1 0.8 All values 3 1.05 0.65 3 1.05 0.65 ) ) ) ) ) Appendix ) H-87 Utilization categories for switches, disconnectors, switch-disconnectors, and fuse combination units to IEC 947-3 and EN 60947 Type of current Typical applications I = current made, Ic = current broken Utilization Ie = rated operational current category U = voltage before make Ue = rated operational voltage Ur = recovery voltage AC-23 A(B)2 Switching of motor loads or other highly inductive loads Verification of electrical endurance Make Ie DC Make Ic Ie Ur Ue cos 0.65 1 1 U Ue L/R ms Ic Ie U Ue cos A I Ie All values 1 1 Ie I Ie A Verification of switching capacity Break Ie Break cos Ic Ie Ur Ue cos 1.05 1.05 0.45 0.35 8 8 1.05 1.05 0.45 0.35 U Ue L/R Ic Ie Ur Ue L/R ms 1 ) 1.05 1 A I Ie U Ue 0.65 Ie 100 Ie > 100 10 10 Ur Ue L/R Ie I Ie ms A ms DC-20 A(B)2 Connecting and disconnecting under no-load condiAll values tions 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) All values 1 ) 1.05 1 DC-21 A(B)2 Switching of resistive loads, including moderate overloads All values 1 1 1 1 1 1 All values 1.5 1.05 1 1.5 1.05 1 DC-22 A(B)2 Switching of mixed resistive and inductive loads, inAll values cluding moderate overloads (e.g. shunt motors) 1 1 2 1 1 2 All values 4 1.05 2.5 4 1.05 2.5 DC-23 A(B)2 Switching of highly inductive loads (e.g. series moAll values tors) 1 1 7.5 1 1 7.5 All values 4 1.05 15 4 1.05 15 ) ) Note 1: If the switching device has a making and/or breaking capacity, the figures for the current and the power factor (time constants) must be stated by the manufacturer. 2: A: frequent operation, B: infrequent operation. Protection against electrical shock, to IEC 536 Damp heat, constant, to IEC 68 Part 2-3 IEC 536 covers the setting up of electrical apparatus, and its arrangement in electrical installations with rated voltages up to 1000 VAC and 1500 VDC, with regard to protection against direct contact where operating elements such as push-buttons and switches are located in the vicinity of live parts. In this test, the effects of a constant high level of humidity (93 +2/-3%) and a constant temperature (40 2)C over a prescribed duration, are observed. "Finger-proofing" relates only to the operating device, and only in the normal direction of operation. A clearance of at least 30 mm radius from the centre point of the device to any live parts, must be ensured. This test is used to assess the suitability of electrical products for operation and storage at high relative humidity levels, in conjunction with cyclic temperature fluctuation. A test cycle consists of 12 hours at 40 2C, with relative humidity of 93 3%, and 12 hours at 25 3C, with the relative humidity of at least 95%. The IP 20 degree of protection is superior to "finger-proofing" in that it embodies protection against contact with electrical apparatus in any direction. Devices which are "finger-proof" and of IP 00 degree of protection can be provided with further protection against contact in the form of shrouding, if so desired. H-88 Appendix Damp heat, cyclic, to IEC 68 Part 2 - 30, Test Db Ambient temperature Ambient temperature is the temperature of the room (e.g. factory bay or switchgear room), in which the open or enclosed device is installed, a prerequisite being that this temperature is not significantly influenced by the heat losses from the device. Glossary of standard terms This Glossary offers brief expIanations of some of the standard terms used in this catalogue. However, it must not be regarded as a substitute for the actual text of the standard, especially where the new terms used in IEC 947 are concerned. Reference is therefore made aIongside each such term to the reIevant section of the standard, e.g. IEC 947-1 in addition, IEV numbers are given to enable you to find foreign language equivalents in the International EIectrotechnicaI Vocabulary (IEG 50), if required. Rated conditional short-circuit current Iq Rated operational current Ie The prospective current which a switching device, e.g. a circuitbreaker, protected by a short-circuit protective device such as a motor-protective circuit-breaker, can carry for the duration of the protective device tripping time. The current which an equipment is capabIe of carrying taking into account the rated operational current, duration of operation, utilization category and ambient temperature. Mininum command time Minimum duration for a trip-initiating factor (controI puIse, short circuit) to effect the corresponding reaction, e.g. the short-circuit duration necessary to initiate tripping. Rated breaking capacity (IEC 947-1; 4.3.5.3) The r.m.s. value of current which a switching device is capable of breaking according to its utiIization category. The rated breaking capacity is stated by reference to the rated operational voltage and the rated operational current. The equipment must be capable of breaking any value of current up to and incIuding its rated breaking capacity stated. Rated actuating voltage Uc (rated control circuit voltage) (IEC 947-1; 4.5.1) The voltage which is applied to the actuating make contact in a control circuit. Due to the presence in the controI circuit of transformers or resistors, this voltage may differ from the rated control supply voltage. Rated service short-circuit breaking capacity Ics (IEC 947-2; 4.3.5.2.2) The prospective short-circuit current which, depending on the rated operationaI voltage, a circuit-breaker is capable of breaking repeatedly (test cycle: O - CO - CO; previousIy P-2). After interrupting this current vaIue, the circuit-breaker must be capable, despite its own thermal level having increased, of continuing to carry and disconnect in the event of overIoading, the rated uninterrupted current. Rating or rated power (IEC 947-1; 4.3.2.3) The rated operational power which an equipment is capable of switching at the associated rated operational voItage in accordance with the utilization category. For example: motor contactor utilization category AC-3: 37 kW at 400 V. Rated operational voltage Ue (IEC 947-1; 4.3.1.1) The voItage to which the characteristics of an equipment are referred. The rated operational current must not in any case exceed the rated insulation voltage. (IEC 947-1; 4.3.2.3) Rated uninterrupted current Iu (IEC 947-1; 4.3.2.4) The vaIue of current which an equipment can carry in uninterrupted duty (i.e. for weeks, months or years). Rated making capacity (IEC 947-1; 4.3.5.2) The vaIue of current which an equipment is capabIe of switching On in accordance with the utilization category and at the rated operational voltage. Rated frequency (IEC 847-1; 4,3.3) The frequency for which an equipment is designed and to which the other characteristic vaIues are referred. Rated ultimate short-circuit breaking capacity Icu (IEC 947-2; 4.3.5.2.1) The maximum prospective fault current which a circuit-breaker is capable of interrupting (test cycIe: O - CO; previously P-1) Rated insulation voltage Ui (IEG 947-1; 4.3.1 .2) The voltage to which insulation tests and creepage distances of an equipment are referred. The maximum operationaI voltage must not in any case exceed the rated insulation voltage. Rated short-circuit breaking capacity Icn (IEC 947-1; 4.3.6.3) The maximum value of current which an equipment is capable of switching Off at rated operational voItage and rated frequency, and without sustaining damage. It is expressed as r.m.s. value. Motor rating (IEC 947-1; 4.3.2.3) Power output of a motor at the associated operational voltage. Rated control supply voltage Us (IEC 947-1; 4.5.1) The voltage applied to the input terminals of the control circuit of an equipment. Due to the presence of transformers or resistors in the control circuit, this may differ from the rated actuating (control circuit) voltage. Appendix H-89 LVSG (IEC 947-1; 2.5.29/IEV 441-17-20) Rated impulse withstand voltage Uimp Finger proof Measures the stability of the internal clearances of an equipment against overvoltage peaks. The utilization of suitable switchgear can ensure that overvoltages are prevented from transferring from the mains to deenergized system sections within it. An equipment whose live parts cannot be touched by the operator during actuation is termed finger proof. This also affects operator activity on neighbouring switching devices. The finger proof area of a push-actuated operating medium is a circular area of at least 30 mm radius around the actuating element, and vertical to the direction of actuation. Rated current In Within this circular area, touch-critical parts must be located at not less than 80 mm depth under the actuating level. (IEC 947-1; 4.3.1 .3) (of a circuit-breaker) (IEC 947-2; 4.3.2.3) For circuit-breakers, this current value is equal to the uninterrupted current and the conventional free air thermaI current. Protection against direct contact Design measures incorporated into equipment in order to prevent direct contact, i.e. without tools, with live parts of a system (finger proof, back-of-hand proof). Control circuit reliability Measures the probability of switching states arising during the lifespan of a contact, which would be interpreted as faults by downstream electronic controllers (PLCs). Control circuit reliability is expressed in values based on tests using standard limit values for signal inputs. Utilization category (IEC 947-1; 2.1 .18/IEV 441-17-19) A combination of specified requirements relating to the condition in which the switching device or the fuse fulfills its purpose, selected to represent a characteristic group of practical applications. The specified requirements may concern, e.g. the values of making capacities, breaking capacities and other characteristic values, data concerning associated circuits, and the relevant conditions of use and behaviour. (IEC 947-2; 4.4) For circuit-breakers, the utilization category denotes whether the equipment is designed for selectivity using time delay (category B) or not (category A). Back-of-hand proof Damp heat, constant An equipment whose live parts cannot be touched by a sphere of 50 mm diameter, is regarded as back-of-hand proof. This test subjects the equipment to an ambient temperature of 40C at a constant humidity of 93%. At set intervals during the test, the electrical and mechanical function of the equipment are examined. Altitude Damp heat, cyclic This test subjects the equipment to cyclically changing climatic conditions: a cycle applies 40C ambient temperature at 93% relative humidity for 12 hours, followed by 12 hours of 25C at 95% relative humidity. At set intervals during the test, the electrical and mechanical function of the equipment are examined. The density of air decreases with increasing altitude, and this reduces its insulating capacity as well as its heat transfer capability. The rated operational voltage and current of switching devices, conductors and motors as well as the tripping behaviour of thermal overload relays are affected by this. Upon request, OMRON ELECTRONICS will supply information as to the suitability or otherwise of switchgear for operation at altitudes above the 2000 m limit specified by the standard. Conventional free air thermal current (IEC 947-1; 4.3.2.1) The maximum value of current which an equipment is capable of carrying for a minimum of eight hours without thermal overloading. As a rule, it corresponds to the maximum operational current. Creepage path (IEC 947-1; 2.5.51/IEV 151-03-37) The shortest distance along the surface of the insulating material between two conductive parts. The creepage distance is determined by the rated insulation voltage, the pollution degree and the creepage current resistance of the material used. Clearance (IEC 947-1; 2.5.46/IEV 441-17-31) The distance between two conductive parts along a string stretched the shortest way between these conductive parts. The clearance in air is determined by the rated impulse withstand voltage, overvoltage category and pollution degree. H-90 Appendix Emergency-stop switching device Overvoltage category Switching device within an emergency-stop circuit which is intended to prevent danger to persons, damage to machinery or working materials. (IEC 947-1; 2.5.60) Opening delay (IEV 441-17-36) Conventional number for prospective overvoltages at the point of installation, as might be caused for example by the effect of lightning or switching processes. The overvoltage category applicable to industrial switchgear is III. The applicability of switchgear according to the overvoltage categories is defined as follows: The interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles. The opening time is the sum of the tripping time and the inherent delay of the contacts. Overvoltage category IV: Closing delay Overvoltage category III: The interval of time between the instant of command and the first make operation of the contacts of the first pole to close. The closing delay is made up of the response delay and the closing time. Operating media with special requirements as to the serviceability for connection in fixed installations, which are protected by overvoltage diversion measures, e.g. circuit-breakers in low-voltage distribution systems or in control systems for industrial use. Shock resistance Overvoltage category II: The capacity of an equipment to withstand pulse-like motions without changing its operating status or sustaining damage. No contact lifting must take place on devices in the On position, the main contacts must not knock against each other in the Off position. A safety switch must not trip, and control circuit switches must not change their switching status. Power consumers for connection to fixed installations, e. g. household appliances, electrical tools. Safe isolation Ambient temperature, open (IEC 536, DIN VDE 0106 Part 101) (IEV 441-11-13) Isolation of circuits not carrying dangerous voltages (e.g. protective extra-low voltage) from circuits in which dangerous voltages flow. Such isolation is achieved by means of reinforced or double insulation which reliably prevents voltage transfer from one circuit to another. This might otherwise take place between main circuits and control circuits in switching devices or between transformer primary and secondary. "Safe isolation" is a priority requirement for safety circuits and functional low-voltage circuits. Room temperature for example of the workshop or switch room in which the switching device is located. (IEC 947-1; 2.1.19) Equipments are deemed to possess this isolating function provided their switching contacts when in the open position, achieve the separation distance prescribed for the isolation of electrical circuits, and their creepage paths and clearance distances are of the required size. The power supply to the entire installation or a section of the installation can thus be cut off for safety reasons, e.g. during maintenance. Tamper proof An emergency-stop switching device is regarded as tamper proof provided it cannot be reset without tools or via a prescribed procedure, after tripping has taken place. The device latches in the tripped position. Accidental or deliberate manipulation (inching) is thus ruled out. Overvoltage category I: Operating media for connection to circuits containing overvoltage protection schemes, e.g. electronic devices. Ambient temperature, enclosed (IEV 441-11-13) Temperature at which the switching device is capable of being operated within a closed housing. For this purpose, it must be taken into account that the heat losses of the device will add to the internal temperature rise within the enclosure. Losses LVSG Isolating function Use allowed directly at the termination point of the installation (directly affected by any lightning), e.g. at an overhead line connection point. (IEV 151-03-18) The difference between the input power and the output power of a device. The main type of loss in electrical power distribution switchgear and operating media is current heat loss. Pollution degree (IEC 947-1; 6./1.3.2) Conventional number for the prospective quantities of conductive dust and humidity which can lead to a reduction in the control circuit reliability of a device. The pollution degree is described by the following influencing factors: Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution does not affect the control circuit reliability. Pollution degree 2: Usually, only non-conductive pollution. However, transient conductivity through condensation is to be expected. Pollution degree 3: (switchgear for industrial use) Conductive pollution or dry, non-conductive pollution which is rendered conductive through condensation. Pollution degree 4: The pollution leads to long-term conductivity, e.g. pollution by conductive dust, rain or snow. Appendix H-91 Coordination type Status of a switchgear combination (motor starter) during and after testing at rated conditional current: Coordination Type "1": - No risk to persons or installations - No requirement for immediate readiness for renewed operation - Damage to the starter is permissible Coordination type "2": - No risk to persons or installations - Starter is capable of renewed operation - No damage to the starter with the exception of a slight welding of the contacts, provided they can be separated without significant deformation. Positive opening operation vided they are mechanically linked in such a way as to ensure that normally open and normally closed contacts can never be closed simultaneously. This arrangement must also ensure that minimum contact separation of 0.5 mm is maintained over the entire lifespan of the device, even during a fault, e.g. the welding of one contact. The relevant German Trade Association requires the use of contactors with interlocked opposing contacts for control systems on power presses in the metal processing industry. Positive/enforced operation/actuation This describes an arrangement where a link between the actuator and the switching element ensures that the force exerted on the actuator is transferred directly, i.e. without the intervention of sprung parts, onto the switching element. (IEC 947-1; 2.4.11/IEV 441-16-12) Positive opening This opening operation is designed to ensure that auxiliary contacts of a switching device are always in the respective positions corresponding to the open or closed position of the main contacts. The contacts of a contactor are interlocked opposing contacts, pro- (IEC 947-1; 2.4.10/IEV 441-16-11) An opening operation which ensures that the main contacts of a mechanical switching device have attained the open position when the actuator is in the Off-position. Symbols used in Technical Data and Formulae DF Icn Duty factor Rated short-circuit breaking capacity Ith Conventional free air thermal current Ithe Conventional thermal current of enclosed devices Ics Rated service short-circuit breaking capacity Iu Rated uninterrupted current Icu Rated ultimate short-circuit breaking capacity SNT Transformer rating Ie Rated operational current Uc Rated actuating voltage I"sc Transformer initial short-circuit current AC Ue Rated operational voltage In Rated current Ui Rated insulation voltage INT Rated transformer current Uimp Rated impulse withstand voltage Iq Rated conditional short-circuit current uk Transformer short-circuit voltage Ir Set value of overcurrent release Us Rated control voltage Irm Response value of non-delayed short-circuit release H-92 Appendix Additional ordering information for contactors CE-Marking The manufacturer has to sign his products with the CE-Marking. With the CE-Marking the manufacturer confirms the accordance with the different EEC Directives. The CE-Marking is absolutely necessary to sell the products in the EEC. Attached you find the EEC Directives concerning our products. Low Voltage Directive (73/23/EEC) EMC Directive (89/336/EEC) Declarations of Conformity art. no. D586.. on request. Test Authorities, Registration Mark, Approvals OMRON Low voltage switchgear is built and tested to national and international specifications. All devices suit all important specifications without any test obligation, like VDE, BS and also relative to IEC Recommendations and to European Standards like IEC 947 and EN 60947. It is for this reason OMRON Low voltage switchgear is used all over the world. In order to provide special versions, limitations to the max. voltages, currents and power ratings or special markings are sometimes necessary. Canada State deputy or private examination CSA UL (state admitted) USA Switzer- Denland mark UL SEV They are classified in "Lloyds Register of Shipping" and in the "Maritime Register of Shipping" (GUS). The "American Bureau of Shipping" does not claim a general approval for single components, the complete electrical equipment on board has to be approved. The devices should have UL- and CSA-approvals. Further information for Guide-No. and File-No. (CSA, UL) you will find on page 95. For approved values see technical data of the devices.State deputy Norway Sweden Finland Poland DEMKO NEMKO SEMKO SETI SEP Slowakia Czech Hungaria SKTC EZU MEEI *1 Label marking of examination boards Duty of approvals or R Approval of All switchgear switchgear commendable Specification UL is authorised for approvals Marking with approbation label is no longer acc. to Canadian Standards necessary No approval since 1.1.1994 Our devices are according to the harmonised European Standards e.g. EN 60947 (IEC 947, VDE 0660) and can be used generally *1) CSA-approvals are replaced by UL-approvals valid for USA and Canada. From 1. 1. 2000 switchgear will be marked with the combined approval. UL-mark or only. Explanations for choice and supply of low voltage switchgears in Canada and USA Marking of auxiliary contacts At several devices in UL-data are two voltages for auxiliary contacts mentioned (e. g.: 600 volts at same potential, 150 volts at different potentials). That means, if the voltage is higher than 150 volts, the control voltage applied to input terminals must be at the same potential Low voltage switchgear for auxiliary circuits (e. g. contactor relays, control units, auxiliary contacts in general) usually approved for "Heavy Duty" or "Standard Duty" UL and besides these marked with the admissible max. voltage or with short codes (see table). Marking of auxiliary contacts according to CSA and UL Contact Rating Code Designation Marking of auxiliary contacts according to CSA and UL Max. rated values per pole Voltage Current Make Break A150 A300 A600 A600 N150 N300 N600 B150 B300 B600 B600 P150 P300 P600 - AC 120 AC 240 AC 480 AC 600 DC 125 DC 250 DC 600 AC 120 AC 240 DC 125 DC 250 AC 120 Max. rated values per pole Voltage Current Make Break Cont. Current V A Heavy Duty AC 120 (HD or HVY DTY) AC 240 AC 480 AC 600 DC 125 DC 250 DC 600 Standard Duty AC 120 (SD or STD DTY) AC 240 AC 480 AC 600 DC 125 DC 250 DC 600 A 60 30 15 12 2,2 1,1 0,4 30 15 7,5 6 1,1 0,55 0,2 A 6 3 1,5 1,2 2,2 1,1 0,4 3 1,5 0,75 0,6 1,1 0,55 0,2 10 10 10 10 10 10 10 5 5 5 5 5 5 5 - - V A 15 7,5 3,75 3 0,55 0,27 0,1 3,6 1,8 0,22 0,11 1,8 A 1,5 0,75 0,375 0,3 0,55 0,27 0,1 0,6 0,3 0,22 0,11 0,3 A Contact Rating Code Designation 2,5 2,5 2,5 2,5 2,5 2,5 2,5 1 1 1 1 0,5 C150 C300 C600 C600 Q150 Q300 Q600 D150 D300 R150 R300 E150 Cont. Current Appendix H-93 LVSG Country OMRON Low voltage switchgear is also suitable for applications in marine environments. Discernment at UL-Standards Recognized Component Industrial Control Equipment Listed Industrial Control Equipment UL issues yellow "Guide cards" with Guide- and File-No. UL issues white "Guide cards" with Guide- and File-No. Devices have permission to be marked with Devices have to be marked with the "UL-Listing Mark" on the label Devices approved for "field wiring", Devices as components approved for "factory wiring": a) devices for employment in control panels, when they are mounted devices for employment in control panels, when they are selected, and wired by skilled worker. mounted and wired according to the charging conditions by skilled worker. b) devices for retail in USA Valid UL-Standards: UL 508Standard for Industrial Control Equipment" (partly limited) Are devices approved as "Listed Equipment" Valid UL-Standards: UL 508Standard for Industrial Control Equipment" (unlimited) UL 486"Standard for Wire Connectors and Soldering Lugs" the approval is also valid for using as "Recognized Component" R. Approvals Country USA, Canada Switzerland UL SEV Europe Type Register of Shipping CENELEC CB-Certificates Great Britain LRS GUS MRS Italy RINA Mini Contactors J7KNA and Accessories J7KNA-AR..(D) o - - o - - - o J7KNA-09..(D) o - - o - - - o J7KNA-12..(D) o - - o - - - - J73KN-A..., J73KN-AM o - - o - - - o Contactors Series J7KN J7KN-10...(D) o - - o - - - o J7KN-14...(D) o - - o - - - o J7KN-18...(D) o - - o - - - o J7KN-22...(D) o - - o - - - o J7KN-24...(D) o - - o - - - o J7KN-32...(D) o - - o - - - o J7KN-40...(D) o - - o - - - o J7KN-50...(D) o - - o - - - o J7KN-62...(D) o - - o - - - o J7KN-74...(D) o - - o - - - o J7KN-85...(D) o - - o - - - o J7KN-110...(D) o - - o - - - o J7KN-150... - - - o - - - - J7KN-175... - - - o - - - - J7KN-200... - - - o - - - - J73N-KB... o - - o - - - o J73N-KC-115 o - - o - - - x J74KN-B-PT... o - - o - - - - J74KN-A-VG... o - - o - - - - J74KN-B-VG - - - o - - - - Accessories Thermal Overload Relays J7TKN-B o - - o - - - x J7TKN-C o - - o - - - x J7TKN-D o - - o - - - x J7TKN-A o - - o - - - o J7TKN-E o - - o - - - o J7TKN-F - - - o - - - - o In Standard version approved H-94 Appendix x In Test - Not provided for test until now and R-Guide- and File-No. These data are important for UL-inspecting Guide-No. Kanada USA Kanada USA Contactors NLDX7 NLDX NLDX8 NLDX2 Accessories NKCR7 NKCR NKCR8 NKCR2 Thermal Overload Relays NKCR7 NKCR - - Circuit Breakers J7MN as Manual Motor Controller NLRV7 NLRV - - Circuit Breakers J7MN as Combination Motor Controller NKJH7 NKJH - - J7MN Bus Bar Assemblies NLRV7 NLRV - - J7MN Accessories NKCR7 NKCR - - LVSG Devices Appendix H-95 Technical information Degree of protection acc. to EN60947 Protection ratings are prefixed by the internationally agreed letters IP followed by two digits. 1st digit: Pertains to solid objects 2nd digit Short description 1 Protected against- Dripping water (vertically falling drops) dripping water shall have no harmful effect. 2 Protected against dripping water when tilted up to 15 Vertically dripping water shall have no harmful effect when the enclosure is tilted at any angle up to 15 from its normal position. 3 Protected against spraying water Water falling as a spray at an angle up to 60 from the vertical shall have no harmful effect. 4 Protected against splashing water Water splashed against the enclosure from any direction shall have no harmful effect. 5 Protected against water jets Water protected by a nozzle against the enclosure from any direction shall have no harmful effect. 2nd digit: Pertains to water. 1st digit Short description 1 Protected against Excludes solid objects exceeding solid objects great- 50 mm in diameter and protects against er than 50 mm contact with live and moving parts by a large body surface such as a hand (but not against deliberate access). 2L Protected against solid objects greater than 12,5 mm and against contact by standard test finger Definition Excludes solid objects exceeding 12,5 mm in diameter and protects against contact with live and moving parts by a standard test finger or similar objects not exceeding 80 mm in length. Definition 3 Protected against Excludes solid objects exceeding solid objects great- 2,5 mm in diameter or thickness. er than 2,5 mm 6 Protected against heavy seas Water from heavy seas or water projected in powerful jets shall not enter the enclosure in harmful quanties. 4 Protected against Excludes solid objects exceeding 1 mm solid objects great- in diameter or thickness. er than 1 mm 7 Protected against the effects of immersion 5 Dust protected Prevents ingress of dust in quantities and locations that would interfere with the intended operation of the equipment. Ingress of water in a harmful quantity shall not be possible when the enclosure is immersed in water under standard conditions of pressure and time. 8 Protected against submersion No ingress of water. 6 Dust tight Prevents ingress of dust. Terminal markings acc. to EN50011 Resistance to climatic conditions acc. to IEC 68 Auxiliary contacts of AC contactors and contacts of contactor relays and thermal overload relays are particularly marked. The terminal markings of normally-open contacts are printed as positive figures, they of normally-closed contacts as negative figures. Open-type devices are climate-resistant in the constant climate according to IEC 68-2-3 (this is a climate with an ambient temperature of 40C and an atmospheric humidity of 90 to 95%). This gives a clear indication of the function of the contacts. The figure below illustrates the determination of terminal markings for contactors with auxiliary contact blocks. Sequence number Enclosed devices are climate-resistant in an alternating climate according to IEC 68-2-30 (this is a moist alternating climate with a 24-hour cycle between climates with an ambient temperature of 25C, and an atmospheric humidity of 95 to 100% and an ambient temperature of 40C, and an atmospheric humidity of 90 to 96% in the presence of condensation during rises in temperature). Data are valid up to an altitude of 2000m above sea level. Short circuit protection Function number The complete terminal marking according to EN 50011 and EN 50012 results from the sequence numbers on the contactor relay or ac contactor (2., 3.) and the function numbers on the auxiliary contact blocks (e. g. .1, .2, or .3, .4). H-96 Appendix Back up fuses should be used to protect contactors and starters against short circuits. For starters the device with the smaller admissible fuse at the main and at the control circuit (contactor or thermal overload) determines the fuse size. After a short circuit devices have to be checked for correct operation. Disconnect power before proceeding with any work on the equipment! Mounting positions of contactors J7KNA-AR... and J7KNA-12... J7KN-10 to J7KN-74, J7KN-85 to J7KN-110 J7KN-150... to J7KN-200 Terminal screws Devices Kind of connection Devices Kind of connection Type Screw with washer Type Screw with washer Screw with clamp box M3,5 - Screw with clamp box Mini Contactors Coil conductor All conductors J7KN-10... to J7KN-110... J7KN-AR...; J7KNA-09...; J7KNA-12... Accessories M3,5 - Contactors Main conductor J73KNA(M)... M3,5 - J73KN-B, J73KN-C M3,5 - - Thermal Overload Relays J7KN-10... to J7KN-22... M3,5 - Main conductor J7KN-24... to J7KN-40... - M5 J7TKN-A M4 J7KN-50... to J7KN-74... - M6 J7TKN-B M3,5 - J7KN-85..., J7KN-110... - M8 J7TKN-C M5 - J7TKN-D - M6 J7KN-10... to J7KN-22... M3,5 - Auxiliary conductor J7KN-85... to J7KN-110 M3,5 - All devices M3,5 - Auxiliary conductor Terminal screws in relation to screwdriver sizes and tightening torques Pozidriv Screw driver Nm lb. inch Pz 1 Size 1 0,6 - 1,2 5 - 11 M3,5 Pz 2 Size 2, 3 0,8 - 1,4 7 - 12 M4 Pz 2 Size 3, 4 1,2 - 1,8 11 - 16 M5 Pz 2 Size 3, 4, 5 2,5 - 3 22 - 26 M6 Pz 3 Size 4, 5 3,5 - 4,5 31 - 40 M8 - - 6 - 10 53 - 88 Version Size Screw with Pozidriv and slot M3 Screw or nut with hexagonal-head Tightening torque Appendix LVSG Terminal screws H-97 General technical information Current carrying capacities of PVC insulated 600/1000 Volt cables with copper or aluminium conductors. In accordance with the 16th edition of the "Wiring Regulations for Electrical Installations". Basic assumptions: Ambient temperature of 30C. Circuit of protected by a OMRON circuit-breaker to IEC 947-2, or a fuse to BS 88 or BS 1361. Figures must be adjusted by the correction factors for ambient temperature and/or cable grouping as detailed in the IEE regs. Conductor In conduit or trunking (enclosed) size mm Clipped to surface or cable tray, bunched, embedded in plaster (unenclosed) Fixed to vertical surface of wall or open cable trench with 20 mm separation between cables and wall Single-phase Three-phase Single-phase Three-phase Single-phase Three-phase Cu [A] Cu [A] Cu [A] Cu [A] Cu [A] Cu [A] Al [A] Al [A] Al [A] Al [A] Al [A] Al [A] Single core, PVC insulated cable non-armoured, copper or aluminium conductors. 1.0 13.5 - 12.0 - 15.5 - 14.0 - - - - - 1.5 17.5 - 15.5 - 20.0 - 18.0 - - - - - 2.5 24.0 - 21.0 - 27.0 - 25.0 - - - - - 4.0 32.0 - 28.0 - 37.0 - 33.0 - - - - - 6.0 41.0 - 36.0 - 47.0 - 43.0 - - - - - 10.0 57.0 - 50.0 - 65.0 - 59.0 - - - - - 16.0 76.0 - 68.0 - 87.0 - 79.0 - - - - - 25.0 101.0 - 89.0 - 114.0 - 104.0 - 126.0 - 112.0 - 35.0 125.0 - 110.0 - 141.0 - 129.0 - 156.0 - 141.0 - 50.0 151.0 118.0 134.0 104.0 182.0 134.0 167.0 123.0 191.0 144.0 172.0 132.0 70.0 192.0 150.0 171.0 133.0 234.0 172.0 214.0 156.0 246.0 185.0 223.0 169.0 95.0 232.0 181.0 207.0 161.0 284.0 210.0 261.0 194.0 300.0 225.0 273.0 206.0 120.0 296.0 210.0 239.0 186.0 330.0 245.0 303.0 226.0 349.0 261.0 318.0 240.0 150.0 300.0 234.0 262.0 204.0 381.0 283.0 349.0 261.0 404.0 301.0 369.0 277.0 185.0 341.0 266.0 296.0 230.0 436.0 324.0 400.0 299.0 463.0 344.0 424.0 317.0 240.0 400.0 312.0 346.0 269.0 515.0 384.0 472.0 354.0 549.0 407.0 504.0 375.0 300.0 458.0 358.0 394.0 306.0 594.0 444.0 545.0 410.0 635.0 469.0 584.0 435.0 400.0 546.0 - 467.0 - 694.0 - 634.0 - 732.0 - 679.0 - 500.0 626.0 - 533.0 - 792.0 - 723.0 - 835.0 - 778.0 - 630.0 720.0 - 611.0 - 904.0 - 826.0 - 953.0 - 892.0 - Twin and multi-core PVC insulated cable, non-armoured, copper or aluminium conductors. 1.0 11.0 - 11.5 - 15.0 - 13.5 - 17.0 - 14.5 - 1.5 14.0 - 15.0 - 19.5 - 17.5 - 22.0 - 18.5 - 2.5 18.5 - 20.0 - 27.0 - 24.0 - 30.0 - 25.0 - 4.0 25.0 - 27.0 - 36.0 - 32.0 - 40.0 - 34.0 - 6.0 32.0 - 34.0 - 46.0 - 41.0 - 51.0 - 43.0 - 10.0 43.0 - 46.0 - 63.0 - 57.0 - 70.0 - 60.0 - 16.0 57.0 54.0 62.0 48.0 85.0 66.0 76.0 59.0 94.0 73.0 80.0 61.0 78.0 25.0 75.0 71.0 80.0 62.0 112.0 83.0 96.0 73.0 119.0 89.0 101.0 35.0 92.0 86.0 99.0 77.0 138.0 103.0 119.0 90.0 148.0 111.0 126.0 96.0 50.0 110.0 104.0 118.0 92.0 168.0 125.0 144.0 110.0 180.0 135.0 153.0 117.0 70.0 139.0 131.0 149.0 116.0 213.0 160.0 184.0 140.0 232.0 173.0 196.0 150.0 95.0 167.0 157.0 179.0 139.0 258.0 195.0 261.0 170.0 282.0 210.0 238.0 183.0 120.0 192.0 - 206.0 160.0 299.0 245.0 259.0 197.0 328.0 - 276.0 212.0 150.0 219.0 - 225.0 184.0 344.0 283.0 299.0 227.0 379.0 - 319.0 245.0 185.0 248.0 - 255.0 210.0 392.0 324.0 341.0 259.0 434.0 - 364.0 280.0 240.0 291.0 - 297.0 248.0 461.0 384.0 403.0 305.0 514.0 - 430.0 330.0 300.0 334.0 - 339.0 258.0 530.0 444.0 464.0 351.0 593.0 - 497.0 381.0 400.0 - - 402.0 - 634.0 - 557.0 - 715.0 - 597.0 - H-98 Appendix Overall diameter of cables (Copper) The dimensions are based on BS specification or the average values as given by the manufacturers. The overall diameters given are for cables of 600/1000 V grade. Number and nominal Approx. overall diameter in mm area of cables (mm2) PVC/SWA PVC Number and nominal Approx. overall diameter in mm area of cables (mm2) PVC/SWA PVC 1 x 1.0 - 4.5 2 x 1.0 - 1 x 1.5 - 4.9 2 x 1.5 11.7 - 1 x 2.5 - 5.8 2 x 2.5 13.1 8.6 1 x 4.0 - 6.8 2 x 4.0 15.1 10.7 7.2 1 x 6.0 - 7.4 2 x 6.0 16.5 12.0 1 x 10.0 - 8.8 2 x 10.0 20.1 14.9 1 x 16.0 - 10.5 2 x 16.0 21.9 17.2 1 x 25.0 - 12.5 2 x 25.0 23.0 18.4 1 x 35.0 - 13.5 2 x 35.0 24.9 20.1 1 x 50.0 19.1 15.1 2 x 50.0 27.8 22.8 1 x 70.0 21.1 16.9 2 x 70.0 30.4 25.5 1 x 95.0 23.4 19.4 2 x 95.0 35.5 29.3 1 x 120.0 26.3 21.0 2 x 120.0 38.0 31.8 1 x 150.0 28.3 23.2 2 x 150.0 41.3 35.1 1 x 185.0 30.8 25.8 2 x 185.0 46.4 39.1 1 x 240.0 34.1 29.0 2 x 240.0 51.2 43.9 1 x 300.0 37.0 32.1 2 x 300.0 56.4 48.7 1 x 400.0 42.0 35.8 2 x 400.0 61.9 54.2 1 x 500.0 45.6 39.6 - - - 1 x 630.0 49.7 43.8 - - - 3 x 1.0 - 3 x 1.5 12.3 3 x 2.5 3 x 4.0 Number and nominal Approx. overall diameter in mm area of cables (mm2) PVC/SWA PVC - 4 x 1.0 - 7.6 4 x 1.5 13.0 8.3 - 13.6 9.1 4 x 2.5 14.5 10.0 15.8 11.5 4 x 4.0 17.8 12.6 3 x 6.0 18.0 12.8 4 x 6.0 19.2 14.2 3 x 10.0 21.2 15.8 4 x 10.0 22.8 17.7 3 x 16.0 23.1 19.7 4 x 16.0 26.3 20.6 3 x 25.0 25.0 20.4 4 x 25.0 27.8 22.9 3 x 35.0 27.3 22.4 4 x 35.0 30.5 25.4 3 x 50.0 30.5 25.5 4 x 50.0 35.4 29.2 3 x 70.0 35.0 28.7 4 x 70.0 39.2 33.0 3 x 95.0 39.3 33.3 4 x 95.0 44.3 38.3 3 x 120.0 42.2 36.3 4 x 120.0 49.3 41.8 3 x 150.0 47.5 40.0 4 x 150.0 53.6 46.3 3 x 185.0 51.9 44.6 4 x 185.0 59.0 61.3 3 x 240.0 57.8 50.1 4 x 240.0 65.7 58.0 3 x 300.0 63.2 55.6 4 x 300.0 72.0 64.6 3 x 400.0 69.6 62.2 4 x 400.0 81.3 72.0 Appendix LVSG Number and nominal Approx. overall diameter in mm area of cables (mm2) PVC/SWA PVC H-99 Conversion table To convert Multiply by Inches to millimeters (mm) 25.4 Millimeters to inches (In.) 0.03937 Feet to meters (m) 0.3048 Conversion table for: Centigrade/Fahrenheit BP-212 meters to feet (ft) 3.2808 200 Yards to meters (m) 0.9144 190 meters to yards (yd) 1.0936 180 Miles to kilometers (km) 1.6093 Kilometers to miles (mil.) 0.6214 Square inches to square millimeters (mm2) 645.16 160 0.00155 150 Square yards to square meters (m2) 0.8361 140 Square meters to square yards (yd2) 1.196 Cubic inches to cubic centimeters (cm3) 16.387 120 0.06102 Pounds to kilogrammes (kg) 0.4536 110 Kilogrammes to pounds (lb) 2.2046 100 1,016.05 Kilogrammes to tons (240 lb) 90 0.0009842 Ounces (avoirdpois) to grammes (g) 0.0353 70 Gallons to litres (l) 4.561 60 Litres to gallons 0.220 50 Force N (newtons) to lbft 1 N = 1 kg (mass) accelerated at 1 metre/sec. 0.225 1 Nm = 1 J (joule) to calorie 0.239 30 Horse-power to kilowatts (kW) 0.7458 20 Kilowatts to horse-power (h.p.) 1 W (watt) = 1J/s 1.3408 10 Atmospheres to lb per square inch (lb/inch2) 1 bar = 1 kg/cm2 = 735.6 mm Hg = 14.2 lb/inch2 FP- 14.68 Conversion table for mm/AWG cable sizes mm2 H-100 AWG 0.75 18 1.0 17 1.5 16 2.5 13 4.0 12 6.0 10 10.0 8 Appendix 70 60 50 40 30 80 28.3495 Grammes to ounces 80 130 Cubic centimeters to cubic inches (inch3) Tons (2,240 lb) to kilogrammes (kg) 90 170 Square millimeters to square inches (inch ) 2 100 40 0 F 20 10 0 10 20 C Rated currents of 3-phase motors (approx. figures for squirrel-cage motors) Minimum fuse size for protection of 3-phase motors The maximum size is determined by the requirements of the switchgear or overload relay. The rated motor currents are for standard 1500 r.p.m. 3-phase enclosed ventilated and totally enclosed fan-cooled motors. D.O.L. starting: Maximum starting current 6 x rated motor current. Maximum starting time 5 s. Y/D starting: Maximum starting current 2 x rated motor current. Maximum starting time 15 s. Set overload relay in the phase lead to 0.58 x rated motor current. Rated fuse currents for Y/D starting are also valid for 3-phase motors with slip-ring motors. For higher rated currents, starting currents and/or longer starting times, larger fuses are required. Table is valid for "slow" and/or "gL" fuses (DIN VDE 0636). For NH fuses with aM characteristics, fuses = rated current is selected. cos kW % 400 V Rated motor current Fuse starting D.O.L. A A 415 V Y/ Rated motor current Fuse starting D.O.L. Y/ Rated motor current Fuse starting D.O.L. Y/ A A A A A A, BS A, BS 0.06 0.7 58 0.37 2.0 - 0.21 2.0 - 0.21 2.0 2 0.09 0.7 60 0.54 2.0 - 0.31 2.0 - 0.30 2.0 2 0.12 0.7 60 0.72 4.0 2 0.41 2.0 - 0.40 2.0 2 0.18 0.7 62 1.04 4.0 2 0.6 2.0 - 0.58 2.0 2 0.25 0.7 62 1.4 4.0 2 0.8 4.0 2 0.8 4.0 2 0.37 0.72 66 2.0 6.0 4 1.1 4.0 2 1.1 4.0 2 0.55 0.75 69 2.7 10.0 4 1.5 4.0 2 1.5 6.0 4 0.75 0.79 74 3.2 10.0 4 1.9 6.0 4 1.8 6.0 4 1.1 0.81 74 4.6 10.0 6 2.6 6.0 4 2.6 10.0 6 1.5 0.81 74 6.3 16.0 10 3.6 6.0 4 3.5 16.0 10 2.2 0.81 78 8.7 20.0 10 5.0 10.0 6 4.8 16.0 10 3.0 0.82 80 11.5 25.0 16 6.6 16.0 10 6.4 20.0 16 4.0 0.82 83 14.8 32.0 16 8.5 20.0 10 8.2 20.0 16 5.5 0.82 86 19.6 32.0 25 11.3 25.0 16 10.9 25.0 20 7.5 0.82 87 26.4 50.0 32 15.2 32.0 16 14.6 35.0 25 11.0 0.84 87 38.0 80.0 40 21.7 40.0 25 20.9 50.0 32 15.0 0.84 88 51.0 100.0 63 29.3 63.0 32 28.2 80.0 40 18.5 0.84 88 63.0 125.0 80 36.0 63.0 40 35.0 80.0 50 22.0 0.84 92 71.0 125.0 80 41.0 80.0 50 40.0 80.0 50 30.0 0.85 92 96.0 200.0 100 55.0 100.0 63 53.0 100.0 80 37.0 0.86 92 117.0 200.0 125 68.0 125.0 80 65.0 125.0 80 45.0 0.86 93 141.0 250.0 160 81.0 160.0 100 78.0 125.0 80 55.0 0.86 93 173.0 250.0 200 99.0 200.0 125 96.0 160.0 100 75.0 0.86 94 233.0 315.0 250 134.0 200.0 160 129.0 250.0 160 90.0 0.86 94 279.0 400.0 315 161.0 250.0 200 155.0 250.0 160 110.0 0.86 94 342.0 500.0 400 196.0 315.0 200 189.0 315.0 200 132.0 0.87 95 401.0 630.0 500 231.0 400.0 250 222.0 355.0 250 160.0 0.87 95 486.0 630.0 630 279.0 400.0 315 269.0 355.0 315 200.0 0.87 95 607.0 800.0 630 349.0 500.0 400 337.0 450.0 355 250.0 0.87 95 - - - 437.0 630.0 500 421.0 500.0 450 315.0 0.87 96 - - - 544.0 800.0 630 525.0 630.0 560 400.0 0.88 96 - - - 683.0 1000.0 800 - - - 450.0 0.88 96 - - - 769.0 1000.0 800 - - - 500.0 0.88 97 - - - - - - - - - 560.0 0.88 97 - - - - - - - - - 630.0 0.88 97 - - - - - - - - - Appendix H-101 LVSG 230 V Motor rating Minimum fuse size for protection of 3-phase motors The maximum size is determined by the requirements of the switchgear or overload relay. The rated motor currents are for standard 1500 r.p.m. 3-phase enclosed ventilated and totally enclosed fan-cooled motors. D.O.L. starting: Maximum starting current 6 x rated motor current. Maximum starting time 5 s. Y/D starting: Maximum starting current 2 x rated motor current. Maximum starting time 15 s. Set overload relay in the phase lead to 0.58 x rated motor current. Rated fuse currents for Y/D starting are also valid for 3-phase motors with slip-ring motors. For higher rated currents, starting currents and/or longer starting times, larger fuses are required. Table is valid for "slow" and/or "gL" fuses (DIN VDE 0636). For NH fuses with aM characteristics, fuses = rated current is selected. 500 V Motor rating cos kW % 600 V Rated motor current Fuse starting Y/ D.O.L. A A A Rated motor current Fuse starting Y/ D.O.L. A A A 0.06 0.7 58 0.17 2.0 - 0.12 2.0 - 0.09 0.7 60 0.25 2.0 - 0.18 2.0 - 0.12 0.7 60 0.33 2.0 - 0.24 2.0 - 0.18 0.7 62 0.48 2.0 - 0.35 2.0 - 0.25 0.7 62 0.70 2.0 - 0.50 2.0 - 0.37 0.72 66 0.90 2.0 2 0.70 2.0 - 0.55 0.75 69 1.20 4.0 2 0.90 4.0 2 0.75 0.79 74 1.50 4.0 2 1.10 4.0 2 1.1 0.81 74 2.1 6.0 4 1.5 4.0 2 1.5 0.81 74 2.9 6.0 4 2.1 6.0 4 2.2 0.81 78 4.0 10.0 4 2.9 10.0 4 3.0 0.82 80 5.3 16.0 6 3.8 10.0 4 4.0 0.82 83 6.8 16.0 10 4.9 16.0 6 5.5 0.82 86 9.0 20.0 16 6.5 16.0 10 7.5 0.82 87 12.1 25.0 16 8.8 20.0 10 11.0 0.84 87 17.4 32.0 20 12.6 25.0 16 15.0 0.84 88 23.4 50.0 25 17.0 32.0 20 18.5 0.84 88 28.9 50.0 32 20.9 32.0 25 22.0 0.84 92 33.0 63.0 32 23.8 50.0 25 30.0 0.85 92 44.0 80.0 50 32.0 63.0 32 37.0 0.86 92 54.0 100.0 63 39.0 80.0 50 45.0 0.86 93 65.0 125.0 80 47.0 80.0 63 55.0 0.86 93 79.0 160.0 80 58.0 100.0 63 75.0 0.86 94 107.0 200.0 125 78.0 160.0 100 90.0 0.86 94 129.0 200.0 160 93.0 160.0 100 110.0 0.86 94 157.0 250.0 160 114.0 200.0 125 132.0 0.87 95 184.0 250.0 200 134.0 250.0 160 160.0 0.87 95 224.0 315.0 250 162.0 250.0 200 200.0 0.87 95 279.0 400.0 315 202.0 315.0 250 250.0 0.87 95 349.0 500.0 400 253.0 400.0 315 315.0 0.87 96 436.0 630.0 500 316.0 500.0 400 400.0 0.88 96 547.0 800.0 630 396.0 630.0 400 450.0 0.88 96 615.0 800.0 630 446.0 630.0 630 500.0 0.88 97 - - - 491.0 630.0 630 560.0 0.88 97 - - - 550.0 800.0 630 630.0 0.88 97 - - - 618.0 800.0 630 H-102 Appendix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|7HUPVDQG&RQGLWLRQVRI6DOHIRUSURGXFWSXUFKDVHDQGXVHDUHRQ2PURQ(c)VZHEVLWH DWZZZRPURQFRPRHLXQGHUWKH|$ERXW8VWDELQWKH/HJDO0DWWHUVVHFWLRQ $//',0(16,2166+2:1$5(,10,//,0(7(56 7RFRQYHUWPLOOLPHWHUVLQWRLQFKHVPXOWLSO\E\7RFRQYHUWJUDPVLQWRRXQFHVPXOWLSO\E\ 20521(/(&7521,&6//& 20521&$1$'$,1& 2QH&RPPHUFH'ULYH 6FKDXPEXUJ,/ )RU86WHFKQLFDOVXSSRUWRURWKHULQTXLULHV 0LOQHU$YHQXH 7RURQWR2QWDULR0%9 2052121/,1( *OREDOKWWSZZZRPURQFRP 86$KWWSZZZRPURQFRPRHL &DQDGDKWWSZZZRPURQFD Cat. No. J7cntctr 09/04 Specifications subject to change without notice Printed in USA Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: J7KNA-09-10 230 J73KN-A-02 J7KN-24 24D J7KN-40 230 J7KNA-09-01 24D J7KNA-09-01W 24 J7KNA-12-01 24VS J7KNA-AR-22 125VS J7KNA-AR-22 230 J7KNA-AR-31 110 J7KNA-AR-31 230 J7KNA-AR-31 24 J7KNA-AR31 24VS J7KNA-AR-40 230 J7KNA-AR-40 24VS J7TKN-A-11 J7TKN-A-1E2 J7TKN-A-1E8 J7TKN-A-23 J7TKN-A2E7 J7TKN-A-30 J7TKN-A-6 J7TKN-A-E6 J7TKN-A-E9 J7TKN-B-11 J7TKN-B-18 J7TKN-B-1E8 J7TKN-B-24 J7TKN-B-4 J7TKN-C-42 J7KN-62 24D J7TKN-B-6