Thumbwheel Switch A7PS/A7PH CSM_A7PS_A7PH_DS_E_3_2 Dust-tight, Easy-to-Use, Push-operated Switches with Large Display Characters * Simple push mechanism and large, easy-to-view numeric display make setting easy. * Dust penetration prevented with seal for the display windows. Ordering Information Switches (Single Switch Units) Model A7PS A7PH Snap-in (front mounting) Snap-in (front mounting) Classification (See note 1.) Long-life type Character height Terminals Color Output code number 03 (decimal code) 06 (binary coded decimal) 07 (binary coded decimal, with componentadding provision) *2 19 (decimal code, with component-adding provision) 54 (binary coded hexadecimal) 55 (binary coded hexadecimal, with component adding provision) *2 Light gray A7PS-203 A7PS-206 Decimal: 6.8 mm Hexadecimal: 4.0 mm Solder terminals *1 Black Light gray Model A7PS-203-1 A7PH-203 A7PS-206-1 A7PH-206 Black A7PH-203-1 A7PH-206-1 A7PS-207 A7PS-207-1 A7PH-207 A7PH-207-1 A7PS-219 A7PS-219-1 A7PH-219 --- A7PS-254 A7PS-254-1 A7PH-254 A7PH-254-1 A7PS-255 A7PS-255-1 --- --- Note: 1. The classification diagrams show 4 Switch Units combined with End Caps to create 4-digit displays. 2. The model numbers given above are for 1 Switch Unit. 3. Models with stoppers are also available. Add "-S@@" after the "203," "206," "207," "219," "254," or "255" in the model number and specify the display range in the @@. For example, to specify the range 0 to 6, add "-S06" to the model number (e.g., A7PS-206-S06-1). 4. Models with +, - displays can also be produced. Add "-PM" after the "206" in the model number (e.g., A7PS-206-PM or A7PS-206-PM-1) *1. Models with PCB terminals are available. *2. Models with diodes are available. Add "-D" to the model number (e.g., A7PS-207-D or A7PS-207-D-1). Accessories (Order Separately) End Caps Use accessories, such as End Caps and Spacers, with the Switch Units. End Caps are used on the Switch Units at each end and allow all the Switch Units to be securely mounted to a panel. They come in pairs, one for the left and one for the right. Accessory End Caps Color Spacer Connectors Solder terminals PCB terminals Light gray Black A7P-M * A7P-M-1 * A7P-P@ A7P-P@-1 (See note.) (See note.) NRT-C NRT-CN NRT-CP Note: The @ in the Spacer model number stands for a letter in the range A to U. (Refer to the table in the following explanation about Spacers.) * The minimum order is for 10 End Caps. Spacers * Spacers are used for creating extra space or gaps between the Switch Units and have the same dimensions as the Switch Units themselves. * There are also Spacers with engraved characters or symbols that can be used for indicating units, such as time and length. (Refer to the following table.) Consult your OMRON representative for details. Symbol A No desStamp ignation B C D E F G SEC MIN H g kg mm Q x 10 SEC T U 0 * Symbol H J K L Stamp cm m C PCS 1 A7PS/A7PH Specifications Item Model A7PS A7PH 50 VAC or 5 to 28 VDC 125 VAC or 5 to 28 VDC Switching capacity (resistive load) 1 mA to 0.1 A 10 A to 0.15 A Continuous carry current 1 A max. 3 A max. Contact resistance 300 m max. 10 M min. (at 500 VDC) 100 M min. (at 500 VDC) Insulation Between non-connected terminals resistance Between terminal and non-current carrying part 1,000 M min. (at 500 VDC) 600 VAC, 50/60 Hz for 1 min Dielectric Between non-connected terminals strength Between terminal and non-current carrying part 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours min. Shock resistance 490 m/s2 min. Mechanical 100,000 operations min. 2,000,000 operations min. Durability Electrical 50,000 operations min. 1,000,000 operations min. Ambient temperature Operating: -10C to 65C Ambient humidity Operating: 45% to 85% Max. operating force 6.37 N max. Dimensions (Unit: mm) Switches A7PS-2@@(-1) A7PH-2@@(-1) Solder Terminal 7.2 A 10 0.1 Number of Switches (n) * 33.5 3 22.6 33 30 Solder terminal 3 4.6 4.3 Panel thickness: 1 to 3 *If the output code is 03,06 or 54, the dimension is 43; if the output code is 07,19 or 55, the dimension is 55. Panel Cutout 31 - 00.4 4.5 8.6 1 B +10 P= 10 0.2 B Size A (n x 10 + 12) Size B (n x 10 + 9) 1 22 19 2 32 29 3 42 39 4 52 49 5 62 59 6 72 69 7 82 79 8 92 89 9 102 99 10 112 109 Note: 1. The dimensions above include both End Caps, and will increase 10 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. The tolerance for multiple connection is (number of units x 0.4) mm. Accessories (Order Separately) End Caps for Push-operated Switches A7P-M(-1) Snap-in Panel Mounting Left Side (39) Right Side 33 (39) 33 4 3 6 6 3 4 4 33.5 33.5 4.4 (4.3) 30 4.5 (4.3) 4.5 30 4.5 Spacers for Push-operated Switches A7P-P@(-1) Snap-in Panel Mounting 30 0.1 32.7 (36.5) 4.5 10 0.05 The @ in the Spacer model number stands for a letter in the range A to U. (Refer to the table under the explanation about Spacers on page 1.) Note: Unless otherwise indicated, dimensional tolerances for dimensions in the models above are 0.4 mm. 2 A7PS/A7PH Connectors (These devices allow Switches to be quickly removed for maintenance and inspection of connectivity, and quickly re-installed.) NRT-C Solder Terminals 48 42 0.15 34 30.2 0.1 NRT-CN Solder Terminals NRT-CP PCB Terminals 34 30.2 0.1 25.4 0.2 34 30 + 0.3 0 Two, 3.3 dia. 7.8 +- 00.3 7.8 - 00.1 0 7.8 - 0.1 UP 9 20.5 P= 2.54 25.4 0.2 1 13.5 1x2 elliptic hole 1 3 0.15 3 2 5 4 32 7 6 9 17.5 3 0.15 P= 2.54 25.4 0.2 13.5 0.6 x 0.6 P= 2.54 3 0.15 25.4 0.2 9 11 8 10 1 3 2 32 9 11 106 3 2 13.5 UP UP 9 20.5 5 4 7 6 9 11 10 8 32 Note: Unless otherwise indicated, dimensional tolerances for dimensions in the models above are 0.4 mm. Inserting Connectors Insert Connectors with the "UP" arrow pointing up. Connector Output Codes/Terminals * Switches with output codes 06 or 07 both use binary coded decimal but Switches with output code 07 have a componentadding provision. Similarly, Switches with output codes 54 or 55 both use binary coded hexadecimal but Switches with output code 55 have a componentadding provision. * How to Read Output Codes For example, when the dial position is "3," the common terminal C on the Switch is connected to terminals 1 and 2. When the Switch is inserted into the Connector, the common terminal C becomes connector terminal 3, and terminals 1 and 2 become connector terminals 5 and 7 respectively. Output code number Terminals Output codes 9 8 7 6 P= 2.54 5 C 30 4 3 2 1 0 03 Twenty -two, 1.1-dia. holes Model 03,19 Switch Unit or Connector Switch Unit Connector C 6 Terminals connected to common 0 1 2 3 4 5 6 7 8 1 2 3 4 5 7 8 9 10 11 1 2 Forty-four, 1-dia. holes 9 8 7 P= 6 5 C 4 3 2 1 0 19 8.5 3 2.54 12.7 30 7 8 9 8 Note: The solid dot indicates that the internal switch is ON (i.e., connected to the common terminal). Model P= 5.08 2 30 1 C 06 07 2.5 3 6 12.7 Component-adding provision Ten, 1.1-dia. holes 5 2.5 06 4 4.5 4 3 Dial 9 0 2.5 3 Common terminal number Switch Unit or Connector Switch Unit Connector Connector Common terminal number C Terminals connected to common 1 2 4 8 5 7 9 11 3 1 0 8 4 P= 5.08 2 Dial Twenty -three, 1.1-dia. holes C 8.5 3 2.5 4.5 Component-adding provision 3 30 1 4 07 1 2 4 5 6 7 8 9 Note: The solid dot indicates that the internal switch is ON (i.e., connected to the common terminal). 3 A7PS/A7PH Output code number Terminals Output codes Switch Unit or Connector Common terminal number Switch Unit C 54 Connector 3 55 Connector 1 Model 54 Ten, 1.1-dia. holes Terminals connected to common 1 2 4 8 5 7 9 11 0 1 2 3 4 5 Dial 6 7 8 9 55 A B C Twenty -three, 1.1-dia. holes D Component-adding provision E F Note: 1. The solid dot l indicates that the internal switch is ON (i.e., connected to the common terminal). Ordering Procedure Place orders as shown in the example below, specifying the model and number. 7 1. 2. 3. 4. 5. 6. A7P-M (End Caps): 1 set A7PS-203 (Switch Unit): 1 piece A7PS-206 (Switch Unit): 1 piece A7P-PA (Spacer): 1 piece A7PS-207 (Switch Unit): 1 piece A7PS-219 (Switch Unit): 1 piece Note: Standard products are not factory-assembled for shipment. Contact your OMRON representative for details on ordering factory-assembled sets. 7. NRT-C (Connector): 4 pieces 1 2 3 4 5 6 1 Safety Precautions Refer to Precautions for Correct Use on in the Technical Guide for Thumbwheel Switches. Precautions for Correct Use Handling * The molded components of the Switch use polyacetal resin and ABS resin. It is recommended that alcohol is used to wipe off dirt and smudges from the molded components. Take care to prevent the alcohol from getting inside. * A7P Thumbwheel Switches are dust-proof, but they are not dripproof. Do not use them in areas subject to water or oil exposure. * Do not allow solder flux or alcohol to enter the Switch. * Do not push the (+) and (-) operating push-buttons at the same time. 4 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.