Auxiliary Contact Blocks Front Mounting Application The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. Description Types of auxiliary contact blocks in standard version for general use: SB8099C2 CA... 1 or 4-pole block, instantaneous with N.O., N.C. contacts. CC... 1-pole block, with N.O. leading contact or N.C. lagging contact. Type of auxiliary contact block for low current and voltage levels (PLC's outputs) and for use in dusty or humid environments: CE... 1-pole block, instantaneous with N.O. contact or N.C. contact, designed in 2 protection versions: CA 5-10 - CE 5-.. D with built-in microswitch IP 40, degree of protection (IP 20 on terminals) - CE 5-.. W with bulit-in microswitch IP 67, degree of protection (IP 20 on terminals). The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking. Fitting Details SB7379C4 Refer to the table below CA 5-40 E For further information about fitting details compatibility with contactors and other types of accessories please refer to: - page 4/37 for A... and AF... 3-pole contactors - page 4/38 for AE..., TAE..., BC... and TBC... 3-pole contactors - page 4/39 for AE... and TAE... 4-pole contactors - page 4/40 for BC... and TBC... 4-pole contactors - page 3/15 for N... and NE..., KC... and TKC... contactor relays Ordering Details For contactors Max. number of blocks Contacts blocks Type Order code Packing Weight pieces kg SB8108C1 1-pole auxiliary contact blocks A 9 ... A 26(1) ................ A 30, A 40(1) ................. A 45 ... A 110 ............... AF 50 ... AF 110 .......... AE 9 ... AE 26 .............. AE 30, AE 40 ............... AE 45 ... AE 110 .......... TAE 45 ... TAE 110 ..... BC 9 ... BC 30 ............. TBC 9 ... TBC 30 ......... KC .., TKC ................... N ..(1), NE ..................... 4 blocks 5 blocks 6 blocks 6 blocks 4 blocks 5 blocks 6 blocks 6 blocks 4 blocks 4 blocks 4 blocks 4 blocks CE 5-01 W 1 - - 1 - - - - CA 5-10 CA 5-01 1SBN 01 0010 R1010 1SBN 01 0010 R1001 10 10 0.014 0.014 - - - - 1 - - 1 CC 5-10 CC 5-01 1SBN 01 0011 R1010 1SBN 01 0011 R1001 10 10 0.014 0.014 1 - 1 - - 1 - 1 - - - - - - - - CE 5-10 D 0.1 CE 5-01 D 0.1 CE 5-10 D 2 CE 5-01 D 2 1SBN 01 0015 R1010 1SBN 01 0015 R1001 1SBN 01 0017 R1010 1SBN 01 0017 R1001 1 1 1 1 0.020 0.020 0.020 0.020 1 - 1 - - 1 - 1 - - - - - - - - CE 5-10 W 0.1 CE 5-01 W 0.1 CE 5-10 W 2 CE 5-01 W 2 1SBN 01 0016 R1010 1SBN 01 0016 R1001 1SBN 01 0018 R1010 1SBN 01 0018 R1001 1 1 1 1 0.020 0.020 0.020 0.020 4-pole auxiliary contact blocks A 9 ... A 26-40-00 .......... 1 block A 45 ... A 110 ................ 1 block AE 9 ... AE 26-40-00 ..... 1 block AE 45 ... AE 110 ............ 1 block BC 9 ... BC 25-40-00 ..... 1 block BC 30-30-00 .................. 1 block 4 3 2 0 1 - 1 2 4 1 - - - - 1 - - - - 1 CA 5-40 E CA 5-31 E CA 5-22 E CA 5-04 E CA 5-11/11 E 1SBN 01 0040 R1040 1SBN 01 0040 R1031 1SBN 01 0040 R1022 1SBN 01 0040 R1004 1SBN 01 0040 R1018 2 2 2 2 2 0.060 0.060 0.060 0.060 0.060 A 9 ... A 40-30-10 .......... 1 block BC 9 ... BC 25-30-10 ..... 1 block 3 2 0 1 1 2 4 1 - - - 1 - - - 1 CA 5-31 M CA 5-22 M CA 5-04 M CA 5-11/11 M 1SBN 01 0040 R1131 1SBN 01 0040 R1122 1SBN 01 0040 R1104 1SBN 01 0040 R1118 2 2 2 2 0.060 0.060 0.060 0.060 N and KC 4-pole ............ 1 block 4 3 2 0 - 1 2 4 - - - - - - - - CA 5-40 N CA 5-31 N CA 5-22 N CA 5-04 N 1SBN 01 0040 R1240 1SBN 01 0040 R1231 1SBN 01 0040 R1222 1SBN 01 0040 R1204 2 2 2 2 0.060 0.060 0.060 0.060 (1) In mounting position 5, there should be no more than 2 N.C. front-mounted auxiliary contacts on types A 9 to A 40-30-01, A 9 to A 26-22-00, A 30-30-32, A 40-30-32, N 22 E, N 31 E. The side-mounted blocks offer additional N.C. contacts. Whatever the mounting position, there should be no more than 2 N.C. front-mounted auxiliary contacts on types A 45 to A 75-22-00. The side-mounted blocks offer additional N.C. contacts. Note: The auxiliary contact blocks provided for the A... contactors can be used for the UA..., GA... and GAE types. >> Auxiliary Contacts for Safety Circuits ................ page 7/4 >> Side Mounted Aux. Contact Blocks ................... page 4/4 >> Mounting and Compatibility of Accessories ............................................................................................................ pages 4/37 to 4/40 4/2 1SBC100122C0201 Low Voltage Products Auxiliary Contact Blocks Front Mounting Technical Data Types 1-pole CA 5, 4-pole CA 5, 1-pole CC 5 Compliance with standards IEC 60947-5-1 and EN 60947-5-1 Certification and approvals section 7 Rated insulation voltage Ui according to IEC 60947-5-1 according to UL/CSA V V 690 600 1-pole CE 5-..0.1 1-pole CE 5-..2 250 250 250 250 24 to 690 125 250 Conventional thermal current Ith A 16 0.1 2 Rated operational current Ie according to IEC 60947-5-1 in a.c. 24 to 127 V 220 to 240 V 380 to 440 V 500 to 690 V A A A A AC-15 6 4 3 2 AC-14 0.1 - - - AC-15 2 2 - - A A A A A A A DC-13 6 2.8 1 0.55 0.55 0.3 0.3 DC-12 0.1 0.1 0.1 0.1 - - - DC-12 2 1 0.3 0.2 0.2 0.1 - A 10 (gG fuses) 0.1 (FF fuses*) 10 (FF fuses*) Rated making capacity 10 x Ie AC-15 6 x Ie AC-14 10 x Ie AC-15 Rated breaking capacity 10 x Ie AC-15 6 x Ie AC-14 10 x Ie AC-15 Rated operational voltage Ue V a.c. in d.c. 24 V 48 V 72 V 110 V 125 V 220 V 250 V Short circuit protection Rated short-time withstand current Icw 1 s = 40 C 0.1 s A A 100 140 - - - - Power loss per pole at 6 A W 0.15 - - 4 17 / 5 (A 9 ... A 75) - 24 / 50 (A 95, A 110) 3/1 17 / 5 Reliability for min. switching capacity - 10-8 10-8 Mechanical durability - millions of operating cycles 10 (A 9 ... A 75) - max. mech. switching frequency cycles/h 3600 5 for CE 5-.. D 2.5 for CE 5-.. W 3600 5 for CE 5-.. D 2.5 for CE 5-.. W 3600 Electrical durability - millions of operating cycles page 4/35 2.5 for CE 5-.. D 0.1 0.7 for CE 5-.. W 0.1 1200 1 for CE 5-.. D 2 0.3 for CE 5-.. W 2 1200 Min. switching capacity V / mA - max. elec. switching frequency cycles/h Connecting terminals (Delivered in open position. Screws of unused terminals should be tightened.) Tightening torque - recommended - max. Nm Nm Connecting capacity (min. ... max.) - Rigid solid 1 or 2 x mm2 - Flexible with cable end - Lugs 1 or 2 x mm l L 2 L mm < l mm > Degree of protection acc. to IEC 60529, IEC 60144, DIN 40050 and NFC 20-010 3 (A 95, A 110) 1200 M3.5 (+,-) pozidriv 2 screw with cable clamp 1.00 1.20 1 ... 4 0.75 ... 2.5 8 3.7 IP 20 for the terminals * HRC fuses for very fast action (6.3 x 32 mm size) >> Terminal Marking and Positioning ............................................................. section 8 Low Voltage Products >> Dimensions .................................................................................................. section 9 4/3 1SBC100122C0201 Auxiliary Contact Blocks Side Mounting Application The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. Description SB7375C2 Types of auxiliary contacts blocks in standard version for general use: CAL 5-11 CAL... 2-pole block instantaneous N.O. + N.C. contacts. CCL ... 2-pole block N.O. leading + N.C. lagging contacts. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact, and bear the corresponding function marking. Fitting Details Clipped onto the right and/or lefthand side of the contactors. The CAL 5-11B is a second block for mounting in addition to a first CAL 5-11 block, right and/or lefthand of the A 145 ... A 300 and AF 145 ... AF 750 contactors. Refer to the table below For further information about fitting details compatibility with contactors and other types of accessories please refer to: - page 4/37 for A... and AF... 3-pole contactors - page 4/38 for AE..., TAE... 3-pole contactors - page 4/39 for AE... and TAE... 4-pole contactors - page 3/15 for N... and NE... contactor relays Ordering Details For contactors Max. number of blocks Contacts blocks Type Packing Weight pieces kg Order code 1 piece 2-pole auxiliary contacts N.O. + N.C. A 9 ... A 110 ............ 2 blocks A 145 ... A 300 ........ 2 blocks (1) AF 50 ... AF 110 ..... 2 blocks AF 145 ... AF 750 ... 2 blocks (1) AE 9 ... AE 40 ......... 2 blocks AE 45 ... AE 110 ..... 1 block TAE 45 ... TAE 110 ... 1 block N ............................. 2 blocks NE ........................... 1 block 1 1 - - CAL 5-11 1SBN 01 0020 R1011 2 0.050 A 145 ... A 300 ........ 2 blocks (1) AF 145 ... AF 750 ... 2 blocks (1) 1 1 - - CAL 5-11B 1SBN 01 0420 R3311 2 0.050 CCL 5-11 1SBN 01 1421 R1008 2 0.050 N.O. leading + N.C. lagging contacts A 9 ... A 16 .............. 2 blocks AE 9 ... AE 16 ......... 2 blocks N ............................. 2 blocks NE .............................. 2 blocks (1) - - 1 1 2 blocks CAL 5-11 + 2 blocks CAL 5-11 B Notes: The auxiliary contact blocks provided for the A... contactors can be used for the UA... and UA..-R contactors. Only one contact block can be mounted on GA... type. >> Auxiliary Contacts for Safety Circuits ................ page 7/4 >> Front Mounted Aux. Contact Blocks .................. page 4/2 >> Mounting and Compatibility of Accessories ............................................................................................................ pages 4/37 to 4/39 4/4 1SBC100122C0201 Low Voltage Products Auxiliary Contact Blocks Side Mounting Technical Data Types CAL 5-11 Compliance with standards IEC 60947-5-1, EN 60947-5-1 Certification and approvals section 7 Rated insulation voltage Ui according to IEC 60947-5-1 according to UL/CSA V V Rated operational voltage Ue V a.c. Conventional free air thermal current Ith A CAL 5-11B CCL 5-11 (1) 690 690 24 to 690 16 Rated operational current Ie acc. to IEC 60947-5-1 AC-15 24-127 V a.c. 220-240 V a.c. 380-440 V a.c. 500-690 V a.c. A A A A 6 4 3 2 DC-13 24 V d.c. 48 V d.c. 72 V d.c. 125 V d.c. 250 V d.c. A A A A A 6 2.8 1 0.55 0.3 A 10 Short-circuit protection - gG type fuses 10 x Ie AC-15 Rated making capacity 4 10 x Ie AC-15 Rated breaking capacity Rated short-time withstand current Icw 1 s = 40 C 0.1 s A A 100 140 Power loss per pole at 6 A W 0.15 Min. switching capacity V / mA 17 / 5 (A 9 ... A 75) - 24 / 50 (A 95 ... AF 750) Mechanical durability - millions of operating cycles - max. mech. switching frequency cycles / h 10 millions (A 9 ... A 75), 3 millions (A 95 ... A 110), 2 millions (A 145 ... AF 750) 3600 Electrical durability - millions of operating cycles - max. elec. switching frequency cycles / h page 4/35 1200 M3.5 (+,-) pozidriv 2 screw with cable clamp Connecting terminals (Delivered in open position. Screws of unused terminals should be tightened.) Tightening torque - recommended - max. Nm Nm 1.00 1.20 Rigid solid 1 or 2 x mm2 1 ... 4 Flexible with cable end 1 or 2 x mm2 0.75 ... 2.5 Connecting capacity (min. ... max.) Lugs l L L mm l mm > Degree of protection according to IEC 60529, IEC 60144, DIN 40050 and NFC 20-010 8 3.7 IP 20 (1) CCL 5-11 auxiliary contact, only for A 9 ... A 16 and AE 9 ... AE 16 contactors and N... contactor relays. >> Terminal Marking and Positioning ............................................................. section 8 Low Voltage Products >> Dimensions .................................................................................................. section 9 4/5 1SBC100122C0201