02/11/2015 www.crouzet.com V4 83170 Dual-current 831708 Part number made to order Nominal ratings 0.1 A to 10 A / 250 VAC Minimum rating 1 mA / 4 VDC Operating temperature up to +125 C Conforming to standards EN 61058 and UL 1054 Choice of actuators with 2 possible fixing positions Part numbers MADE TO ORDER Type Function Connections Dual-current 831708 I (changeover) X1S - X2 - X2S - X3 - X3S Specifications Electrical characteristics Rating nominal / 250 VAC (A) Rating thermal / 250 VAC (A) 0,1 6 Mechanical characteristics Maximum operating force (N) Min. Release force (N) Maximum total travel force (N) Max. permitted overtravel force (N) Maximum rest position (mm) Operating position (mm) Max. differential travel mm Min. overtravel (mm) Ambient operating temperature (C) Mechanical life (operations) Contact gap (mm) Weight (g) 1,5 0,3 1,8 10 9,2 8,40,3 0,15 0,5 -20 +125 106 0,4 1,7 Additional specifications Components Material - Case : polyester UL 94 VO - Button : Glass-filled polyamide - Contacts : AgNi, gold-plated AgNi (dual-current) - Terminals : cupro-nickel (except W7A5 in brass) Levers - Flat : stainless steel - Roller : stainless steel, polyamide roller Approvals NF - UL - cUL Principles Dimensions (mm) Product 83170 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Asymmetrical version No Legend OL = 7.6 Dimensions (mm) Product 83170 Symmetrical version Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 Dimensions (mm) Connections W2 Dimensions (mm) Connections W7A5 Dimensions (mm) Connections X1 - X1S Dimensions (mm) Connections Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 www.crouzet.com X2 - X2S Dimensions (mm) Connections X3 - X3S Dimensions (mm) Drilling Printed circuit board mounting Asymmetrical X1 - X2 - X3 No Legend 1.C 4.NO 2.NC Dimensions (mm) Drilling Printed circuit board mounting Symmetrical X1S - X2S - X3S Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 No www.crouzet.com Legend 1.C 4.NO 2.NC Dimensions (mm) Drilling Mounting on a printed circuit board with fixing pins Asymmetrical Dimensions (mm) Drilling Mounting on a printed circuit board with fixing pins Symmetrical Dimensions (mm) Actuator mounting positions Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Fixing position Except where otherwise indicated, levers are supplied unmounted. For factory mounting, specify fixing position A or B. To calculate force : divide the switch force by the coefficient in the table. To calculate travel : multiply the switch travel by the same coefficient. Dimensions (mm) Actuators 170A Fixing position Except where otherwise indicated, levers are supplied unmounted. For factory mounting, specify fixing position A or B. To calculate force : divide the switch force by the coefficient in the table. To calculate travel : multiply the switch travel by the same coefficient. Dimensions (mm) Actuators 170E Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Fixing position Except where otherwise indicated, levers are supplied unmounted. For factory mounting, specify fixing position A or B. To calculate force : divide the switch force by the coefficient in the table. To calculate travel : multiply the switch travel by the same coefficient. Dimensions (mm) Actuators 170F Fixing position Except where otherwise indicated, levers are supplied unmounted. For factory mounting, specify fixing position A or B. To calculate force : divide the switch force by the coefficient in the table. To calculate travel : multiply the switch travel by the same coefficient. Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Dimensions (mm) Actuators Fixing pins Fixing position Except where otherwise indicated, levers are supplied unmounted. For factory mounting, specify fixing position A or B. To calculate force : divide the switch force by the coefficient in the table. To calculate travel : multiply the switch travel by the same coefficient. No Legend Output on unit side : X2 Dimensions (mm) Actuators Fixing pins Fixing position Except where otherwise indicated, levers are supplied unmounted. For factory mounting, specify fixing position A or B. To calculate force : divide the switch force by the coefficient in the table. To calculate travel : multiply the switch travel by the same coefficient. No Legend Output on cover side : X3 Curves Operating curve for types 831708 / 831709 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Models 831708 and 831709 are designed to operate equally well on dual-current (1 mA 4 V minimum) or medium-current (5 A maximum) circuits. However, a given product should only be used to switch one type of circuit during its working life. No Legend Number of cycles Resistive circuit Mechanical life limit Current in Amps Connections Actuators and fixing positions Other information Mounting - Operation See basic technical concepts Product adaptations Special levers Special connections Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 831708A1.0 831708A2.0 831708C1.0 831708C1.BL 831708C5.0 831708B2.0 831708C1.AL 831708C1.EL 831708C2.0 831708C2.FL 831708C4.0 831708C1.FL 831708C2.AL 831708C2.CL 831708C3.0 831708C2.EL 831708B1.0