GLQ110 Series Installation & Operating Instructions
P/N: A272-168 Rev 2 12/29/09 Ref: 03361001602
Installation & Safety
To comply with the published safety standards, the following must be observed when
using this power supply:
1. Maximum ambient temperature for the power supply must not exceed 50°C.
2. When installing the power supply in the end-use equipment, special attention
is required to ensure safety compliance with the following safety standards:
UL60950, EN60950-1, IEC60950-1, and CSA22.2 No. 234-M90; including the
requirements for creepage distances, clearances, and distance through insulation
between primary wiring and earth or secondary (SELV) wiring.
3. The power supply’s rated input voltage is automatically selected. Please refer to
the specication sheet for the input voltage range.
4. The maximum output power of the supply must not exceed the rating indicated in
the specication sheet.
5. The earth ground wire must be connected only to the point marked with the earth
ground symbol (on the unit).
6. Hazardous voltages exist in the primary circuits. Disconnect the power supply
before servicing.
7. When operating with a dc input voltage range, the unit input must be protected by
a dc rated fuse in the end-use installation system.
8. The internal fuse should only be replaced with a 4 A, 250 V ac, Type SP0001.1010
manufactured by Schurter AG, Type 216004 manufactured by Littelfuse or Type
S501 manufactured by Cooper.
9. This power supply is marked following the provisions of the Low Voltage
Directive, 2006/95/EC.
For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or
send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for
additional product information and specication sheets.
Output Ratings
Model OutputVoltage
(V)
ConvectionCooling 30CFMForcedAirCooling
Max.Output
Current(A)
Max.Output
Power(W)
Max.Output
Current(A)
Max.Output
Power(W)
GLQ112
+5 9.0
80
11.0
110
+12 4.5 5
-12 0.7 1.0
±5 to ±25 2.5 3.0
GLQ113
+5 9.0 11.0
+15 4.5 5.0
-15 0.7 1.0
±5 to ±25 2.5 3.0
GLQ114
+5 9.0 11.0
+12 4.5 5.0
-12 0.7 1.0
+24 3.5 4.5
Connector PIN Designation
InputConnector PIN GLQ112 GLQ113 GLQ114
SK1
1 GND
3 Neutral
5 Line
OutputConnector PIN GLQ112 GLQ113 GLQ114
SK2
1
+5 V2
3
4
Common
5
6
7
8 +12 V +15 V +12 V
9 +12 V +15 V +12 V
10 -12 V -15 V -12 V
11 +5 V to +25 V +5 V to +25 V +24 V
12 -5 V to -25 V -5 V to -25 V Common
SK201 1 +Sense
2 -Sense
SK202 1 P OK
2 GND
GLQ110 Series Installation & Operating Instructions
GLQ112, GLQ113, and GLQ114 are commercial designations of model numbers LPQ112, LPQ113, and LPQ114 respectively.
While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Ofce. All other product or service names are the property of their registered owners. ©2009 EGS Electrical Group, LLC. All rights reserved. Specications subject to change without notice.
Mechanical Outline
4.00
[101.6]
3.50
[88.9]
.25 [6.35]
.25 [6.35]
6.50 [165.1]
7.00 [177.8]
1
12
±5 ~ ±25 V
O/P ADJ
SK201
SK202
5 V O/P ADJ
1
3
5SK1
SK2
Top View
Mechanical Dimensions
4.28
[108.6]
2.50
[63.5]
6.40 [162.6]
7.30 [185.5]
2.20
[56.0]
5.90 [150.0]
.86
[21.8]
All dimensions are in inches [mm]
Screw size: #6-32
Bottom View with Optional L-Bracket
Side View with Optional L-Bracket
GLQ110 Series Specifications
Input
Input ra nge 85-264 Vac; 120-300 Vdc
Frequency 47-440 Hz
Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25°C
Efficiency 70% typical at full load
EMI filter Meets FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Safety ground
leakage current <0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power 80 W for convection; 110 W with 30 CFM forced air
Adjustment range ±5% min. on main; 5-25 V on 4th output on GLQ112 and GLQ113
Cross regulation ±2% on output 1; ±3% on outputs 2, 3 & 4
Hold-up time 20 ms @ 80 W load, 115 Vac nominal line
Overload protection Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5.7 to 6.7 Vdc on main output; Latching type, recycle AC to reset
Minimum Load 2 A for the first output, 0.5 A for the 4th output of GLQ114
Logic Control
Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation.
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Operating temperature 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C (except for -C version).
Storage temperature -40°C to 85°C
Temperature coefficient ±0.04% per °C
Electromagnetic
susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational
MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions
Mating Connectors
AC Input Molex 09-50-8051 (USA)
09-91-0500 (UK); PINS: 08-58-0111
DC Outputs Molex 09-50-8121 (USA)
09-91-1200 (UK); PINS: 08-58-0111
Remote Sense/
Power Fail
Molex 22-01-1022 (USA)
22-01-1023 (UK); PINS: 08-50-0114
Connector Kit #70-841-008, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm).
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L bracket mounting (6-32) maximum insertion depth is .20”.
7. Warranty: 2 year
8. Weight: 1.25 lbs/0.57 kg
Phone: (800) 377-4384
Email: tech@solahd.com
www.solahd.com
Electrical Specifications
Environmental Specifications
GLQ123 Installation & Operating Instructions
Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-189 Rev 0 5/21/09 Ref: NTQ123\OP
To comply with the published safety standards, the following must be observed when using
this power supply:
1. Maximum ambient temperature for the power supply must not exceed 50°C.
2. When installing the power supply in the end-use equipment, special attention is required
to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1,
IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage
distances, clearances, and distance through insulation between primary wiring and earth
or secondary (SELV) wiring.
3. The power supply’s rated input voltage is automatically selected. Please refer to the
specication sheet for the input voltage range.
4. The maximum output power of the supply must not exceed the rating indicated in the
specication sheet.
5. The earth ground wire must be connected only to the point marked with the earth ground
symbol (on the unit).
6. The disconnection from the line must be in the end system.
7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before
servicing.
8. The unit must be protected by a fuse in the end system. Components, such as capacitors,
may be positioned in front of the internal fuse.
9. The internal fuse should only be replaced with a F4AL, 250 V ac, type 19370 manufac-
tured by Wickmann.
10. This equipment is considered Class I according to protection against electric shock.
11. This power supply is marked following the provisions of the Low Voltage Directive,
2006/95/EC.
12. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an
e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional
product information and specication sheets.
Output Ratings
Output Voltage (V) 30 CFM Forced Air Cooling (unit not convection rated)
Max. Output Current (A) Max. Output Power (W)
+5 24.0
120
+3.3 25.0
+12 2.0
-12 1.0
Mechanical Outline
SK1
SK4
SK3
SK2
SK5
SK6
5
3
1
1
2
3
6
10
1
5
5 V Adj.
3.3 V Adj.
Connector PIN Designation
Input Connector PIN Designation
SK1 1 Earth GND
3 Neutral
5 Line
Output Connector PIN Designation
SK2 +5 V
SK3 Common
SK4 +3.3 V
SK5 1 +12 V
2 Common
3 -12 V
SK6
1 +3.3 V SWP (Single Wire Parallel)
2 -Sense
3 +3.3 V +Sense
4 +5 V SWP (Single Wire Parallel)
5 Common
6 +5 V +Sense
7 -Sense
8 +Inhibit
9 -Inhibit
10 Power Fail
GLQ123 Installation & Operating Instructions
Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions
©2009 EGS Electrical Group, LLC. All rights reserved. Specications subject to change without notice.
While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC.
assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
GLQ123 is a commercial designation of model number NTQ123.
Typical Ventilation Setup
1.00 [25.4]
11.81 [300.0]
4.72 [120.0]
1.13 [28.7]
1.72 [43.8]
10.43 [265.0]
2.85 [72.5]
F
A
N
Air Flow
System Chassis
Ac Input
Output
F
A
N
F
A
N
30 CFM forced air cooling
NOTE: Dimensions and fan used are for reference only
Mechanical Dimensions
4.00 [101.6]
2.50 [63.5]
7.00 [177.8]
5.50 [139.7]
4.71 [119.6]
6.50 [165.1]
1.50[38.1]
.75 [19.0]
a a
a
aa b b
Side View
Bottom View
All dimensions are in inches [mm]
Screw size: a = #6-32 (U.S.); b = M3 (International)
Maximum screw protrusion: 0.6″ [1.5 mm]
GLQ123 Specifications
Input
Input ra nge 85-264 Vac; 120-300 Vdc
Frequency 47-63 Hz
Inrush current 38 A max, cold start @ 25°C
Efficiency 65% typical at full load
EMI filter FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated;
EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated
Power factor 0.99 typical
Safety ground
leakage current <1 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power 70 W for convection; 120 W with 30 CFM forced air
Adjustment range ±5% min. on outputs one and two
Hold-up time 20 ms @ 120 W load, 120 Vac input
Overload protection Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overvoltage protection 3.3 to 5 V output; 20% to 35% above nominal output
Minimum Load 2 A for the second output
Logic Control
Power failure TTL logic signal goes high 100-500 msec after 5 V output. It goes low at least 4 msec before loss of regulation.
Remote inhibit Requires an external TTL Signal to inhibit outputs
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Operating temperature 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C
Storage temperature -40°C to 85°C
Temperature coefficient ±0.04% per °C
Electromagnetic
susceptibility Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.7G peak 5Hz to 500Hz, operational
MTBF demonstrated >1 million hours at full load and 25°C ambient conditions
Mating Connectors
(SK1)
AC Input
Molex 09-50-8051 (USA)
09-91-0500 (UK); PINS: 08-58-0111
SK2,3,4 Molex series 19141-0058/0063
(SK5)± 12 V Molex 09-50-8031 (USA)
09-91-0300 (UK); PINS: 08-58-0111
(SK6) Control
Signals
Molex 90142-0010; PINS: 90119-2110 or
Amp: 87977-3; PINS: 87309-8
Connector Kit #70-841-012, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm).
3. Remote inhibit requires an external 5 V @ 10 mA to activate.
4. Mounting maximum insertion depth is 0.12”.
5. Warranty: 1 year
6. Weight: 1.38 lbs/0.63 kg
Phone: (800) 377-4384
Email: tech@solahd.com
www.solahd.com
Electrical Specifications
Environmental Specifications
GLQ142 Installation & Operating Instructions
Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-177 Rev 0 6/1/09 Ref: LPQ142/OP.C
To comply with the published safety standards, the following must be observed when using
this power supply:
1. Maximum ambient temperature for the power supply must not exceed 50°C. Derate
each output 2.5% per degree from 50°C to 70°C ambient temperature.
2. When installing the power supply in the end-use equipment, special attention is
required to ensure safety compliance with the following safety standards: UL60950-1,
EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements
for creepage distances, clearances, and distance through insulation between primary
wiring and earth or secondary (SELV) wiring.
3. The ac-dc input connector is approved as a component of the power supply, however, it
was not specically evaluated to IEC60320.
4. This power supply is approved and certied for the rated voltage range of 100 V ac to
250 V ac and/or 120 V dc (minimum) to 370 V dc (maximum).
5. The earth ground wire must be connected only to the point marked with the earth
ground symbol (on the unit).
6. The disconnection from the line must be in the end system.
7. When operating with a dc input voltage range, the dc source must be rectied from a
mains supply not exceeding 250 V ac. The unit input must also be protected by a dc
rated fuse in the end-use installation system.
8. The internal fuse (F1) should only be replaced by a 4 A, 250 V ac, type GDA-V/S501
manufactured by Bussman.
9. This equipment is considered Class I according to protection against electric shock.
10. This power supply is marked following the provisions of the Low Voltage Directive,
2006/95/EC.
11. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send
an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for addi-
tional product information and specication sheets.
Output Ratings
Output Voltage (V)
Convection Cooling 30 CFM Forced Air Cooling
Max. Output
Current (A) Max. Output
Power (W) Max. Output
Current (A) Max. Output
Power (W)
V1: +3.3 to +5.7 12.0
80 without cover
60 with cover
25.0 145 with or without
cover
145 with cover &
internal fan
V2: +12.0 to +12.7 5.0 6.0
V3: -12.0 to -15.0 1.0 1.5
V4: +3.3 to +25.0 1.5 4.5
Mechanical Outline
SK5
SK2
SK6
1
2
6
1
P252
P251
SK3
10
6
5
1
V4 Adj.
Fine Course
V1
Adj.
5
3
1
SK1
Connector PIN Designation
Input Connector PIN Designation
SK1 1 Earth GND
3 Neutral
5 Line
Output Connector PIN Designation
SK2
1 V2
2, 4 Common
3 V3
5 V4
6 V4 (Return)
SK3 P251 Common
P252 V1
SK5
(optional for units with cover & fan) 1 V2
2 Common
SK6
1 V4 SWP (Single Wire Parallel)
2 Dc OK
3 +V4 Sense
4 V1 SWP (Single Wire Parallel)
5 Common
6 +V1 Sense
7 Sense Common
8 +Inhibit
9 -Inhibit
10 Power Fail
GLQ142 Installation & Operating Instructions
Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions
©2009 EGS Electrical Group, LLC. All rights reserved. Specications subject to change without notice.
While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC.
assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
GLQ142 is a commercial designation of model number LPQ142.
Typical Ventilation Setup
AIR FLOW
MIN 30 CFM
AIR FLOW
MIN 30 CFM
VENTILATION BOX
A
F
N INPUT CONNECTOR
1.77 [45.0]
5.00 [127.0]
14.37 [365.0]
3.07 [78.0]
2.36 [60.0]
3.35 [85.1]
1.54 [39.1]
1.54 [39.1]
5.04 [128.1]
INPUT CONNECTOR
FAN
.39 [9.9] .39 [9.9]
POWER SUPPLY
POWER SUPPLY
Top View
Side View
30 CFM forced air cooling
NOTE: Dimensions and fan used are for reference only
Mechanical Dimensions
4.71 [119.6]
5.50 [139.7]
7.00 [177.8]
2.50 [63.5]
6.75 [171.5]
6.36 [161.5]
1.50 [38.1]
0.75 [19.1]
1.15 [29.1]
0.25 [6.4]
4.00 [101.6]
B
A
B A
BAAB
AB
AB
Bottom View
All dimensions are in inches [mm]
Screw sizes: A = M3 (International); B = #6-32 (U.S.)
Recommended maximum screw protrusion: 0.06″ [1.5 mm]
Side View
GLQ142 Specifications
Input
Input ra nge 85-264 Vac; 120-300 Vdc
Frequency 47-67 Hz
Inrush current 38 A max, cold start @ 25°C
Efficiency 75% typical at full load
EMI filter FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Power factor 0.99 typical
Safety ground
leakage current 1.0 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power 80 W convection (60 W with cover)
145 W with 30 CFM forced air (100 W with cover)
Adjustment range 3.3 - 5.5 V on main; -12 - 15 V on 3rd output; 3.3 - 25 V on 4th output
Hold-up time 20 ms @ 175 W load at nominal line
Overload protection Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overvoltage protection Tracks outputs 1, 3 & 4; 10 to 35%
Minimum Load 0.5 A for the 4th output
Logic Control
AC Power failure TTL logic signal goes high 100-500 msec after V1 output. It goes low at least 4 msec before loss of regulation.
Remote inhibit Requires contact closure to inhibit outputs
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
DC - OK TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation.
Operating temperature 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C (except for -C version).
Storage temperature -40°C to 85°C
Temperature coefficient ±0.4% per °C
Electromagnetic
susceptibility Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational
MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions
Mating Connectors
(SK1) AC Input Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK); PINS: 08-58-0111
(SK2) Aux DC Output Molex 09-50-8061 (USA); Molex 09-91-0600 (UK); PINS: 08-58-0111
(SK6) Control Signals Molex 90142-0010 (USA); PINS: 90119-2110 or Amp: 87977-3, PINS: 87309-8
(SK4) Main Output Molex BB-19141-0058
Connector Kit #70-841-017, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm).
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 years
6. Weight: 1.63 lbs/0.74 kg
Phone: (800) 377-4384
Email: tech@solahd.com
www.solahd.com
Electrical Specifications
Environmental Specifications