Du line Supply Coupling Unit Type G 3485 0000 (R) Fieldbus Installationbus * For systems using a combined communication-supply bus (3-wires) * Input from a standard 15... 30 VDC power supply * Coupling of transmission- and supply-common * Output current 4 A max. * H4-housing Product Description The supply coupling unit is mainly used in those applications, where multiple Dupline(R) modules of the type G21...700 are to be supplied through a DC-bus. Since these modules use the same wire for the common of the transmission signal and the Ordering Key "minus" of the DC-supply, the G 3485 000 assures proper coupling of the supply to maximise the noise immunity of the entire installation. To supply a current 4 A (up to 25C) / 3 A (under 50C), multiple coupling units may be installed in parallel. Type Selection G 3485 0000 700 Type: Dupline(R) H4-Housing Power supply Output Specifications Supply Ordering no. 15 to 30 VDC G 3485 0000 700 Output Output voltage VBB Output current Short-circuit protection Output voltage drop 15 to 30 VDC (pulsating) 4 A (up to 25C) 3 A (under 50C None 1 VDC Supply Specifications General Specifications Power supply Operational voltage through term. 7 (+) & 8 Ripple Reverse polarity protection Current consumption Power consumption Inrush current Transient protection voltage Indication for Dupline(R) carrier Supply Environment Degree of protection Pollution degree Operating temperature Storage temperature Humidity (non-condensing) Mechanical resistance Shock Vibration Dimensions Material (See "Technical information") Weight Insulation voltage Supply - Dupline(R) Supply - output Installation cat. III (IEC 60664) 15 to 30 VDC (ripple included) 3V Yes 30 mA 0,5 W 200 mA 800 V None None Specifications are subject to change without notice (30.04.03) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group LED, yellow LED, green IP 20 B 3 (IEC 60664) -20 to +50C (-4 to +122F) -50 to +85C (-58 to +185F) 20 to 80% 15 G (11 ms) 2 G (6 to 55 Hz) H4-housing 200 g 1 Du line G 3485 0000 (R) Fieldbus Wiring Diagram Mode of Operation The supply coupling unit was designed for all those applications where DC-supplied Dupline(R) modules of the type G 21...700 are used. The characteristic of these modules is, that the common of the transmission signal is identical to the minus of the supply. The catalogue states that such modules shall not be supplied by a DC-bus which exceeds the distance of 3 m. In the worst case this means that an individual DC-supply unit must be used for every module. In some applications this is impossible because there is no power available at site. The supply of such units through a DC-bus can now be done through the use of the G 3485 0000. S S(Dupline(R)) I1 I2 GND + O1 O2 G2140 5520 700 S(Dupline(R)) I1 I2 GND + O1 O2 G2140 5520 700 1 2 3 4 5 6 7 8 Dupline(R) Installationbus The supply voltage at the input terminals of the unit is coupled to the output terminals via a switching device that is synchronised by the Dupline(R) signal carrier. The supply is decoupled from the 3-wire during the short periods of signal transmission where a load current could cause disturbances. The maximum current per coupling unit is 4 A (up to 25C) / 3 A (under 50C). Multiple coupling units may be connected to the same supply in parallel if the maximum current consumption of the system (supply of Dupline(R) modules and supply of load) exceeds the maximum output for a single unit. Accessories = G3485 0000 700 DIN-rail ~ FMD 411 For further information refer to "Accessories". 21 22 23 24 25 26 27 28 D34900000 S: signal wire Dimensions (mm) Design Rules Note the output voltage drop of 1.0 V. This, together with the output voltage drop of G 2140 5507 00, should be taken into consideration when selecting the output voltage of the standard DC-supply. Also, the DC-supply must be able to supply twice the total load current, since the output voltage of G 3485 0000 700 is pulsating. There is a limit for the voltage drop VCW in the common wire. If the entire load is in the far end from the G34850000700, then the max. VCW is 2.0 V. H4-housing The above limitations can be overcome by adding another DC-supply with G34850000 700 along the line. Whenever another pair (G3485000700 and DC-supply) is added the two pairs will supply half the load current running in half the wire resistance and hereby the VCW - limit is increased by a factor of 4. VCW = RCW x ITL RCW : Resistance in the common wire ITL = Total load current If the load is distributed uniformly along the 3-wire, then max. VCW is 3.5 V. 2 Specifications are subject to change without notice (22.03.2006) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group