MS5806-02BA Miniature Altimeter Module * * * * * * * * * * * High resolution module, 20cm Fast conversion down to 1 ms Low power, 1 A (standby < 0.15 A) Integrated digital pressure sensor (24 bit ADC) Supply voltage 1.8 to 3.6 V Operating range: 300 to 1100 mbar, -40 to +85 C Extended Pressure Range: 10 to 2000mbar 2 I C or SPI interface (Mode 0, 3) No external components (Internal oscillator) Excellent long term stability Hermetically sealable for outdoor devices DESCRIPTION The MS5806-02BA is a new generation of high resolution altimeter sensors from MEAS Switzerland with SPI 2 and I C bus interface. It is optimized for altimeters and variometers with an altitude resolution of 20cm. The sensor module includes a high linearity pressure sensor and an ultra low power 24 bit ADC with internal factory calibrated coefficients. It provides a precise digital 24 Bit pressure and temperature value and different operation modes that allow the user to optimize for conversion speed and current consumption. A high resolution temperature output allows the implementation of an altimeter/thermometer function without any additional sensor. The MS5806-02BA can be interfaced to virtually any microcontroller. The communication protocol is simple, without the need of programming internal registers in the device. The gel protection and antimagnetic stainless steel cap allows the use in 100m water resistant altimeter/compass watches. This new sensor module generation is based on leading MEMS technology and latest benefits from MEAS Switzerland proven experience and know-how in high volume manufacturing of altimeter modules, which has been widely used for over a decade. The sensing principle employed leads to very low hysteresis and high stability of both pressure and temperature signal. FEATURES FIELD OF APPLICATION TECHNICAL DATA * * * * * Sensor Performances (VDD = 3 V) Pressure Min 10 Range ADC Mobile altimeter / barometer systems Bike computers Adventure or multi-mode watches Variometers Dataloggers Resolution (1) FUNCTIONAL BLOCK DIAGRAM VDD Meas. MUX SENSOR CSB +IN Digital Interface PGA -IN ADC Sensor Interface IC Response time SDI/SDA SDO dig. Filter Accuracy 25C, 750 to 1100 mbar Accuracy -20C to + 85C, 300 to 1100 mbar (2) SCLK Memory (PROM) 128 bits SGND Long term stability Temperature Range Resolution Accuracy at 25C Typ Max 2000 24 0.13 / 0.084 / 0.054 / 0.036 / 0.024 Unit mbar bit mbar -1.5 +1.5 mbar -2.5 +2.5 mbar 0.5 / 1.1 / 2.1 / 4.1 / 8.22 +1 Min Typ Max -40 +85 <0.01 -0.8 +0.8 ms mbar/yr Unit C C C GND Note: the communication protocol is defined by hardware (I2c: version 52 and SPI: version 42) DA5806-02BAxx_007 000058061951 ECN2205 Notes: (1) Oversampling Ratio: 256 / 512 / 1024 / 2048 / 4096 (2) With autozero at one pressure point ww.meas-spec.com 1/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module PERFORMANCE SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS Parameter Supply voltage Storage temperature Overpressure Maximum Soldering Temperature Symbol VDD TS Pmax Conditions Tmax Min. -0.3 -40 ISO 2281 Max +3.6 +85 10 Unit V C bar 40 sec max 250 C -4 +4 kV -100 +100 mA Typ. 3.0 +25 12.5 6.3 3.2 1.7 0.9 1.4 0.02 Max 3.6 +85 Unit V C Typ. 24 8.22 4.13 2.08 1.06 0.54 Max Human Body Model JEDEC standard No 78 ESD rating Latch up Typ. ELECTRICAL CHARACTERISTICS Parameter Operating Supply voltage Operating Temperature Symbol VDD T Conditions Min. 1.8 -40 OSR Supply current (1 sample per sec.) IDD Peak supply current Standby supply current VDD Capacitor 4096 2048 1024 512 256 during conversion at 25c From VDD to GND 100 Conditions Min. A 0.14 mA A nF ANALOG DIGITAL CONVERTER (ADC) Parameter Output Word Symbol OSR Conversion time DA5806-02BAxx_007 000058061951 ECN2205 tc 4096 2048 1024 512 256 ww.meas-spec.com 2/18 7.40 3.72 1.88 0.95 0.48 9.04 4.54 2.28 1.17 0.60 Unit bit ms February 25th, 2014 MS5806-02BA Miniature Altimeter Module PERFORMANCE SPECIFICATIONS (CONTINUED) PRESSURE OUTPUT CHARACTERISTICS (VDD = 3 V, T = 25C UNLESS OTHERWISE NOTED) Parameter Operating Pressure Range Extended Pressure Range Absolute Accuracy, no autozero Absolute Accuracy, autozero at one pressure point Maximum error with supply voltage (1) Maximum error with supply voltage compensation (1) (2) Long-term stability Conditions Prange Full Accuracy Pext Linear Range of ADC at 25C, 700..1100 mbar at 0..50C, 300..1100 mbar at -20..85C, 300..1100 mbar at 25C, 700..1100 mbar at 0..50C, 300..1100 mbar at -20..85C, 300..1100 mbar Min. 300 10 -1.5 -2.0 -3.5 -0.5 -1.0 -2.5 Typ. Max 1100 2000 +1.5 +2.0 +3.5 +0.5 +1.0 +2.5 Unit mbar mbar mbar mbar VDD = 1.8 V ... 3.6 V +/- 3 mbar VDD = 2.2 V ... 3.0 V +/-0.6 mbar +1 0.024 0.036 0.054 0.084 0.130 mbar/yr OSR 4096 2048 1024 512 256 Resolution RMS (1) With autozero at 3V point (2) With voltage compensation for accumulator application mbar TEMPERATURE OUTPUT CHARACTERISTICS (VDD = 3 V, T = 25C UNLESS OTHERWISE NOTED) Parameter Absolute Accuracy Maximum error with supply voltage(1) Conditions 700 ... 1100mbar -20..85C VDD = 1.8 V ... 3.6 V OSR Resolution RMS Min. -0.8 -2.0 4096 2048 1024 512 256 Typ. Max +0.8 +2.0 Unit C +/- 0.5 C 0.002 0.003 0.005 0.008 0.012 C (1) With autozero at 3V point DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 3/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module PERFORMANCE SPECIFICATIONS (CONTINUED) DIGITAL INPUTS (CSB, DIN, SCLK, SDA, SCL) Parameter Serial data clock Input high voltage Input low voltage Input leakage current Load capacitance Symbol SCLK VIH VIL Ileak25C CIN Conditions SPI protocol Pins CSB Min. Typ. 80% VDD 0% VDD at 25c Max 10 100% VDD 20% VDD 0.15 Unit MHz V V A pF Max 100% VDD 20% VDD Unit V V pF 8 DIGITAL OUTPUTS (DOUT, SDA, SCL) Parameter Output high voltage Output low voltage Load capacitance DA5806-02BAxx_007 000058061951 ECN2205 Symbol VOH VOL CLOAD Conditions Isource = 0.6 mA Isink = 0.6 mA Min. 80% VDD 0% VDD Typ. 16 ww.meas-spec.com 4/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module PERFORMANCE CHARACTERISTICS PRESSURE ERROR VS PRESSURE AND TEMPERATURE Absolute pressure accuracy with 2nd order compensation Typical Pressure accuracy vs temperature Typical 3.0 85C 1.0 25C 0C 0.0 -20C -1.0 -2.0 -3.0 0 200 400 600 800 1000 Pressure error [mbar] Pressure error [mbar] 2.0 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 -1.0 -2.0 1200mbar 2nd order 900 mbar 2nd order 600mbar 2nd order 1200mbar 1st order 900mbar 1st order 600mbar 1st order -20 1200 0 20 40 60 80 Temperature [C] Pressure [mbar] TEMPERATURE ERROR VS TEMPERATURE AND EXTENDED PRESSURE RANGE (TYPICAL ERROR) Temperature accuracy vs temperature Typical Absolute pressure accuracy with 2nd order compensation Typical in extended pressure range 2.0 10.0 0.0 8.0 900mbar 2nd order 6.0 900mbar 1st order 4.0 2.0 Pressure error [mbar] Temperature error [C] 12.0 85 -2.0 -25 -4.0 25 -6.0 -8.0 0.0 -2.0 -10.0 -40 -20 0 20 40 60 80 0 200 Temperature [C] 400 600 800 1000 1200 1400 1600 1800 2000 Pressure [mbar] PRESSURE AND PSRR TEMPERATURE VS SUPPLY VOLTAGE Pressure error vs supply voltage at 25C Typical Pressure error [mbar] 3.0 2.0 1000 mbar 1.0 compensation 0.0 -1.0 -2.0 -3.0 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 Supply voltage [V] DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 5/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module FUNCTIONAL DESCRIPTION VDD Meas. MUX CSB +IN SENSOR Digital Interface PGA -IN ADC SDI/SDA SDO dig. Filter SCLK Memory (PROM) 128 bits Sensor Interface IC SGND GND Figure 1: Block diagram of MS5806-02BA GENERAL The MS5806-02BA consists of a piezo-resistive sensor and a sensor interface IC. The main function of the MS5806-02BA is to convert the uncompensated analogue output voltage from the piezo-resistive pressure sensor to a 24-bit digital value, as well as providing a 24-bit digital value for the temperature of the sensor. FACTORY CALIBRATION Every module is individually factory calibrated at two temperatures and two pressures. As a result, 6 coefficients necessary to compensate for process variations and temperature variations are calculated and stored in the 128-bit PROM of each module. These bits (partitioned into 6 coefficients W1 to W6) must be read by the microcontroller software and used in the program converting D1 and D2 into compensated pressure and temperature values. The 2 coefficients W0 and W7 are for factory configuration and CRC. SERIAL INTERFACE 2 The MS5806-02BA has built in two types of serial interfaces: SPI and I C. The pin PS is factory connected to GND or VCC to define the Protocol Select: Module ref MS5806-02BA52 MS5806-02BA42 Mode 2 IC SPI Pins used SDA, SCL, CSB SDI, SDO, SCLK, CSB SPI MODE The external microcontroller clocks in the data through the input SCLK (Serial CLocK) and SDI (Serial Data In). In the SPI mode module can accept both mode 0 and mode 3 for the clock polarity and phase. The sensor responds on the output SDO (Serial Data Out). The pin CSB (Chip Select) is used to enable/disable the interface, so that other devices can talk on the same SPI bus. The CSB pin can be pulled high after the command is sent or after the end of the command execution (for example end of conversion). The best noise performance from the module is obtained when the SPI bus is quiet and without communication to other devices during the ADC conversion in progress. DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 6/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module 2 I C MODE The external microcontroller clocks in the data through the input SCLK (Serial CLocK) and SDA (Serial DAta). 2 The sensor responds on the same pin SDA which is bidirectional for the I C bus interface. So this interface type uses only 2 signal lines and does not require a chip select, which can be favorable to reduce board space. In 2 2 I C-Mode the complement of the pin CSB (Chip Select) represents the LSB of the I C address. It is possible to 2 use two sensors with two different addresses on the I C bus. The pin CSB shall be connected to VDD or GND (do not leave unconnected!). Pin CSB High Low Address (7 bits) 0x76 (1110110 b) 0x77 (1110111 b) COMMANDS The MS5806-02BA has only five basic commands: 1. Reset 2. Read PROM (128 bit of calibration words) 3. D1 conversion 4. D2 conversion 5. Read ADC result (24 bit pressure / temperature) Bit number Bit name Command byte 0 1 2 PRM COV - 3 Typ 4 5 6 7 Ad2/ Ad1/ Ad0/ Stop Os2 Os1 Os0 Command Reset Convert D1 (OSR=256) Convert D1 (OSR=512) Convert D1 (OSR=1024) Convert D1 (OSR=2048) Convert D1 (OSR=4096) Convert D2 (OSR=256) Convert D2 (OSR=512) Convert D2 (OSR=1024) Convert D2 (OSR=2048) Convert D2 (OSR=4096) ADC Read PROM Read 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 1 1 1 1 1 0 0 1 0 0 0 0 1 0 0 0 0 1 0 Ad2 0 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 hex value 1 0 0 1 1 0 0 0 1 1 0 0 Ad1 1 0 1 0 1 0 0 1 0 1 0 0 Ad0 0 0 0 0 0 0 0 0 0 0 0 0 0 0x1E 0x40 0x42 0x44 0x46 0x48 0x50 0x52 0x54 0x56 0x58 0x00 0xA0 to 0xAE Figure 2: Command structure PRM COV Typ ADx / OSx Stop DA5806-02BAxx_007 000058061951 ECN2205 PROM read bit Conversion selection bit D1 or D2 selection bit (Conversion mode) Address PROM or OSR configuration Stop bit Figure 2a: Bit description ww.meas-spec.com 7/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module PRESSURE AND TEMPERATURE CALCULATION Start Maximum values for calculation results: PMIN = 10mbar PMAX = 2000mbar TMIN = -40C TMAX = 85C TREF = 20C Convert calibration datadata into coefficients (see bit pattern W1 to W4) Read calibration (factory calibrated) from of PROM Variable Description | Equation Recommended variable type Size [1] [bit] min max Example / Typical 46372 Value C1 Pressure sensitivity | SENST1 unsigned int 16 16 0 65535 C2 Pressure offset | OFFT1 unsigned int 16 16 0 65535 43981 C3 Temperature coefficient of pressure sensitivity | TCS unsigned int 16 16 0 65535 29059 C4 Temperature coefficient of pressure offset | TCO unsigned int 16 16 0 65535 27842 C5 Reference temperature | TREF unsigned int 16 16 0 65535 31553 C6 Temperature coefficient of the temperature | TEMPSENS unsigned int 16 16 0 65535 28165 Read digitalpressure pressure and and temperature data Read digital temperature data D1 Digital pressure value unsigned int 32 24 0 16777216 6465444 D2 Digital temperature value unsigned int 32 24 0 16777216 8077636 68 Calculate temperature dT Difference between actual and reference temperature [2] dT = D2 - TREF = D2 - C5 * 2 8 signed int 32 25 -16776960 16777216 TEMP Actual temperature (-40...85C with 0.01C resolution) TEMP = 20C + dT * TEMPSENS = 2000 + dT * C6 / 223 signed int 32 41 -4000 8500 2000 = 20.00 C Calculate temperature compensated compensated pressure Calculate temperature pressure OFF Offset at actual temperature [3] OFF = OFFT1 + TCO * dT = C2 * 217 + (C4 * dT ) / 26 signed int 64 41 -17179344900 25769410560 5764707214 SENS Sensitivity at actual temperature [4] SENS = SENST1 + TCS * dT = C1 * 2 16 + (C3 * dT ) / 27 signed int 64 41 -8589672450 12884705280 3039050829 P Temperature compensated pressure (10...1200mbar with 0.01mbar resolution) P = D1 * SENS - OFF = (D1 * SENS / 2 21 - OFF) / 2 15 signed int 32 58 1000 120000 110002 = 1100.02 mbar Display pressure and temperature value Notes [1] [2] [3] [4] Maximal size of intermediate result during evaluation of variable min and max have to be defined min and max have to be defined min and max have to be defined Figure 3: Flow chart for pressure and temperature reading and software compensation. DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 8/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module SECOND ORDER TEMPERATURE COMPENSATION Figure 4: Flow chart for pressure and temperature to the optimum accuracy. PRESSURE COMPENSATION WITH SUPPLY VOLTAGE It is recommended to use this formula only in the specified voltage range. During the ADC conversion, the power supply VDD must be stable. Calculate pressure vs. Supply voltage Power supply compensation from 2.2V to 3.0V P [mbar] P = P + ((3.0-VDD) * C7 / 26 ) Figure 5: Flow chart for pressure compensation VS supply voltage. DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 9/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module SPI INTERFACE (MS5806-02BA42 ONLY) RESET SEQUENCE The Reset sequence shall be sent once after power-on to make sure that the calibration PROM gets loaded into the internal register. It can be also used to reset the device ROM from an unknown condition Figure 6: Reset command sequence SPI mode 0 0 1 2 3 4 5 6 7 SCLK CSB SDI 2.8ms RELOAD SDO PS Figure 6a: Reset command sequence SPI mode 3 DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 10/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module CONVERSION SEQUENCE The conversion command is used to initiate uncompensated pressure (D1) or uncompensated temperature (D2) conversion. The chip select can be disabled during this time to communicate with other devices. After the conversion, using ADC read command the result is clocked out with the MSB first. If the conversion is not executed before the ADC read command, or the ADC read command is repeated, it will give 0 as the output result. If the ADC read command is sent during conversion the result will be 0, the conversion will not stop and the final result will be wrong. Conversion sequence sent during the already started conversion process will yield incorrect result as well. 0 1 2 3 4 5 6 7 SCLK CSB SDI 8.22ms ADC CONVERSION SDO PS Figure 7: Conversion out sequence, Typ=d1, OSR = 4096 Figure 8: ADC Read sequence PROM READ SEQUENCE The read command for PROM shall be executed once after reset by the user to read the content of the calibration PROM and to calculate the calibration coefficients. There are in total 8 addresses resulting in a total memory of 128 bit. Address 0 contains factory data and the setup, addresses 1-6 calibration coefficients and address 7 contains the serial code and CRC. The command sequence is 8 bits long with a 16 bit result which is clocked with the MSB first. Figure 9: PROM Read sequence, address = 011 (Coefficient 3) DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 11/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module I2C INTERFACE (MS5806-02BA52 ONLY) COMMANDS 2 Each I C communication message starts with the start condition and it is ended with the stop condition. The MS5806-02BA address is 111011Cx, where C is the complementary value of the pin CSB. Since the IC does 2 not have a microcontroller inside, the commands for I C and SPI are quite similar. RESET SEQUENCE The reset can be sent at any time except when the power on did not work it could be possible that the acknowledge blocks the SDA. When SDA is blocked by an undefined state the only way to get the MS5806-02BA to work is to send a power on reset. 1 1 1 0 1 1 CSB 0 0 0 0 0 1 1 1 1 0 0 command Device Address A P S Device Address W A cmd byte From Master From Slave S = Start Condition P = Stop Condition W = Write R = Read A = Acknowledge N = Not Acknowledge 2 Figure 10: I C Reset Command CONVERSION SEQUENCE A conversion can be started by sending the command to MS5806-02BA. When command is sent to the system it stays busy until conversion is done. When conversion is finished the data can be accessed by sending a Read command, when an acknowledge appears from the MS5806-02BA, you may then send 24 SCLK cycles to get all result bits. Every 8 bit the system waits for an acknowledge signal. 1 1 1 0 1 1 CSB 0 0 0 1 0 0 1 0 0 0 0 Device Address command S Device Address A P W A cmd byte From Master From Slave S = Start Condition P = Stop Condition W = Write R = Read A = Acknowledge N = Not Acknowledge 2 Figure 11: I C Command to initiate a pressure conversion (OSR=4096, typ=D1) 1 1 1 0 1 1 CSB 0 0 0 0 0 0 0 0 0 0 0 Device Address command S W A cmd byte Device Address A P From Master From Slave S = Start Condition P = Stop Condition W = Write R = Read A = Acknowledge N = Not Acknowledge 2 Figure 12: I C ADC read sequence 2 Figure 13: I C pressure response (D1) on 24 bit from MS5806-02BA DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 12/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module PROM READ SEQUENCE The PROM Read command consists of two parts. First command sets up the system into PROM read mode. The second part gets the data from the system. 1 1 1 0 1 1 CSB 0 0 1 0 1 0 0 1 1 0 0 Device Address command S Device Address W A cmd byte A P From Master From Slave S = Start Condition P = Stop Condition W = Write R = Read A = Acknowledge N = Not Acknowledge 2 Figure 14: I C Command to read memory address= 011 (Coefficient 3) 2 Figure 15: I C answer from MS5806-02BA CYCLIC REDUNDANCY CHECK (CRC) MS5806-02BA contains a PROM memory with 128-Bit. A 4-bit CRC has been implemented to check the data validity in memory. The application note AN520 describes in detail CRC-4 code used. A d d D B 1 5 0 1 2 3 4 5 6 16 bit reserved for manufacturer Coefficient 1 (16 bit unsigned) Coefficient 2 (16 bit unsigned) Coefficient 3 (16 bit unsigned) Coefficient 4 (16 bit unsigned) Coefficient 5 (16 bit unsigned) Coefficient 6 (16 bit unsigned) Coefficient 7 - - - CRC (8 bit unsigned) 7 D B 1 4 D B 1 3 D B 1 2 D B 1 1 D D D D D D D D D D D B B B B B B B B B B B 1 9 8 7 6 5 4 3 2 1 0 0 Figure 16: Memory PROM mapping DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 13/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module APPLICATION CIRCUIT The MS5806-02BA is a circuit that can be used in conjunction with a microcontroller in mobile altimeter applications. It is designed for low-voltage systems with a supply voltage of 3 V. SPI protocol communication I2C protocol communication 2 Figure 17: Typical application circuit with SPI / I C protocol communication DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 14/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module PIN CONFIGURATION AND DEVICE PACKAGE OUTLINE Figure 18: Pin configuration and package outlines, recommended PCB footprint PIN 1 2 3 4 5 6 NAME: I2C - SPI SDI - SDA CSB VDD GND SCLK - SCL SDO - NU TYPE I I P G I O FUNCTION Serial Data Input Chip Select (Active low) Positive Supply Voltage Ground Serial Data Clock Serial Data Out RECOMMENDED PAD LAYOUT Figure 19: Pin configuration and package outlines, recommended PCB footprint DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 15/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module SHIPPING PACKAGE Figure 20: Tape & reel DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 16/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module MOUNTING AND ASSEMBLY CONSIDERATIONS SOLDERING Please refer to the application note AN808 available on our website for all soldering issues. MOUNTING The MS5806-02BA can be placed with automatic Pick & Place equipment using vacuum nozzles. It will not be damaged by the vacuum. Due to the low stress assembly the sensor does not show pressure hysteresis effects. It is important to solder all contact pads. CONNECTION TO PCB The package outline of the module allows the use of a flexible PCB for interconnection. This can be important for applications in watches and other special devices. SEALING WITH O-RINGS In products like outdoor watches the electronics must be protected against direct water or humidity. For those products the MS5806-02BA provides the possibility to seal with an O-ring. The protective cap of the MS5806-02BA is made of special anticorrosive stainless steel with a polished surface. In addition to this the MS5806-02BA is filled with silicone gel covering the sensor and the bonding wires. The O-ring (or O-rings) shall be placed at the outer diameter of the metal cap. This method avoids mechanical stress because the sensor can move in vertical direction. CLEANING The MS5806-02BA has been manufactured under cleanroom conditions. It is therefore recommended to assemble the sensor under class 10'000 or better conditions. Should this not be possible, it is recommended to protect the sensor opening during assembly from entering particles and dust. To avoid cleaning of the PCB, solder paste of type "no-clean" shall be used. Cleaning might damage the sensor! ESD PRECAUTIONS The electrical contact pads are protected against ESD up to 4 kV HBM (human body model). It is therefore essential to ground machines and personnel properly during assembly and handling of the device. The MS5806-02BA is shipped in antistatic transport boxes. Any test adapters or production transport boxes used during the assembly of the sensor shall be of an equivalent antistatic material. DECOUPLING CAPACITOR Particular care must be taken when connecting the device to the power supply. A 100 nF ceramic capacitor must be placed as close as possible to the MS5806-02BA VDD pin. This capacitor will stabilize the power supply during data conversion and thus, provide the highest possible accuracy. DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 17/18 February 25th, 2014 MS5806-02BA Miniature Altimeter Module ORDERING INFORMATION Product Code MS5806-02BA52 MS5806-02BA42 Product MS5806-02BA I2C Miniature Altimeter Module MS5806-02BA SPI Miniature Altimeter Module Art. No MS580602BA52-51 MS580602BA42-51 Delivery Form Tape& reel TOP-UP Tape& reel TOP-UP FACTORY CONTACTS NORTH AMERICA EUROPE Measurement Specialties 45738 Northport Loop West Fremont, CA 94538 MEAS Switzerland Sarl Ch. Chapons-des-Pres 11 CH-2022 Bevaix Tel: +1 800 767 1888 Fax: +1 510 498 1578 e-mail: pfg.cs.amerameas-spec.com Website: www.meas-spec.com Tel: +41 32 847 9550 Fax: + 41 32 847 9569 e-mail: sales.chameas-spec.com Website: www.meas-spec.com ASIA Measurement Specialties (China), Ltd. No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen, 518057 China Tel: +86 755 3330 5088 Fax: +86 755 3330 5099 e-mail: pfg.cs.asiaameas-spec.com Website: www.meas-spec.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer's technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. DA5806-02BAxx_007 000058061951 ECN2205 ww.meas-spec.com 18/18 February 25th, 2014 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: MS5806-02BA42