I/O I/O
V600-HAM42-DRT
(Amplifier)
V600-HS@@
(Sensors)
V600-D@@
(Data Carriers)
V600 RFID System
Master Unit Master Unit
CompoBus/D ( -compatible)
V600-HAM42-DRT
Intelligent Flag
Amplifier
for CompoBus/D
System Configuration
2Intelligent Flag III V600-HAM42-DRT
Intelligent Flag III
V600-HAM42-DRT
An RFID system that is as easy and simple to
use as a sensor. No programming required.
Conforms to DeviceNet standards.
Uses the same main functions (Read, Write, Bit Set, Bit Clear,
etc.) as those of the V600-HA Intelligent Flag Series.
Responds flexibly to applications with data reading up to 24 bits.
Allows data to be written in units of up to 16 bits.
CE marking/FCC approvals.
Ordering Information/Specifications
Amplifier
Item V600-HAM42-DRT
Communications power supply
voltage 11 to 25 VDC (provided from communications connector)
Internal circuit power supply voltage 18 to 26.4 VDC
Internal current consumption Communications power supply: 40 mA max.
Internal circuit power supply: 150 mA max.
Noise immunity Internal circuit power supply normal: ±600 V
Internal circuit power supply common: ±1,500 V
Dielectric strength 50/60 Hz at 500 V AC for 1 minute; leakage current 10 mA max.
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude, with 4 sweeps of 8 min each in 3 directions
Shock resistance 294 m/s2, 3 times each in 3 directions (18 times total)
Ambient temperature 0 to 55°C (with no icing)
Ambient humidity 35% to 85% RH (with no condensation)
Storage temperature 25 to 65°C
Degree of protection IEC 60529: IP20 (panel mounted)
Mounting method DIN track or direct mounting using accessory fittings (M4 screws)
Weight Approx. 150 g
Intelligent Flag III V600-HAM42-DRT 3
Sensor
Performance
Model V600-HS51 V600-HS61 V600-HS63 V600-HS67
Shape
Item
Oscillation frequency 530 kHz
Ambient temperature 10 to 60°C10 to 70°C
Storage temperature 25 to 75°C
Ambient humidity 35% to 95%
Insulation resistance 50 M (at 500 V DC) between cable terminal and case
Dielectric strength 1,000 V AC, 50/50 Hz for 1 min between cable terminal and cable (leakage current 1 mA max.)
Degree of protection IEC 60529: IP67
Vibration resistance 10 to 2,000 Hz, 3-mm double amplitude, with 2 sweeps
of 15 min each in 3 directions
10 to 500 Hz, 2-mm double amplitude, with 3 sweeps of
11 min each in 3 directions
Shock resistance 981 m/s2, 3 times each in 3 directions (18 times total) 490 m/s2, 3 times each in 3 directions (18 times total)
Cable length 2 m (fixed)
Wireless transmission
error direction
16-bit CRC (Cyclic Redundancy Check) in both directions
Indicator --- Power: green
Weight Approx. 70 g Approx. 190 g Approx. 540 g
Number of Master words Input: 2; output: 2 (total: 4 words)
Number of sensor connections 1 channel
Applicable sensors V600-HS51, V600-HS61, V600-HS63, V600-HS67
Read DATA READ mode Read 24 bits of data from the set address
Write BYTE mode Write 8-bit or 16-bit data from the set address
BIT SET mode Set (write “1”) only the data for the bits that are set (with “1”) at the set address
BIT CLEAR mode Clear (write “0”) only the data for the bits that are set (with “1”) at the set address
4Intelligent Flag III V600-HAM42-DRT
System Configuration
Programmable Controller
V600-HAM42-DRT
V600-HS51 V600-HS61 V600-HS63 V600-HS67
Programmable Controller
V600-HAM42-DRT
V600
-D23P53
V600
-D23P54
V600
-D23P55
V600
-D23P61
V600
-D23P66N
V600
-D23P66SP
V600
-D23P72
V600
-D23P71
V600
-D8KR12
V600
-D8KR13
V600
-D8KR04
V600
-D2KR16
I/OI/O
Amplifier Sensor Data Carriers
Host System
Master Unit Master Unit
Intelligent Flag III V600-HAM42-DRT 5
Transmission Distance Specifications
Note: 1. Sensor installation conditions
V600-HS51: When flush-mounted in iron
Axial offset from the Data Carrier ±2.0 mm
V600-HS61: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±2.0 mm
V600-HS63: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±10.0 mm
V600-HS67: When surface-mounted on metal (ferrous)
Axial offset from the Data Carrier: ±10.0 mm
2. Data Carrier installation conditions
V600-D23P53/-P54: When flush-mounted in iron
V600-D23P55: When flush-mounted in iron, the transmission distance decreases greatly.
V600-D23P66N/-P66SP/-P71/-P72: When surface-mounted on resin (no metal on the backside)
V600-D23P61: When surface-mounted on metal (ferrous)
V600-D8KR12/13/04: When surface-mounted on metal (ferrous)
V600-D2KR16: When the Data Carrier attached to the holder is mounted on metal (ferrous)
3. The transmission distance specified in the specifications is also applicable when the Data Carrier is mounted on non-metallic surfaces.
4. The Data Carrier is stationary.
Characteristic Data (Typical)
Transmission Range
Note: All units are in millimeters unless otherwise indicated.
Combinations with the V600-HS51 Sensor
Data Carrier
Amplifier V600-HAM42-DRT
Sensor V600-HS51 V600-HS61 V600-HS63 V600-HS67
Memory
EEP-ROM Type
V600-D23P53 0.5 to 3.0 mm 0.5 to 3.0 mm --- ---
V600-D23P54 0.5 to 5.0 mm 0.5 to 5.5 mm --- ---
V600-D23P55 0.5 to 7.0 mm 0.5 to 7.0 mm --- ---
V600-D23P61 0.5 to 8.0 mm 0.5 to 9.0 mm 2 to 16 mm ---
V600-D23P66N --- --- 5 to 30 mm 5 to 35 mm
V600-D23P66SP --- --- 5 to 25 mm 5 to 30 mm
V600-D23P71 --- --- 5 to 35 mm 10 to 65 mm
V600-D23P72 --- 0.5 to 18 mm 5 to 35 mm 10 to 45 mm
Memory
S-RAM Type
V600-D8KR12 5 to 15 mm 5 to 18 mm 5 to 45 mm 10 to 50 mm
V600-D8KR13 --- --- 2 to 15 mm ---
V600-D2KR16 --- --- 2 to 15 mm ---
V600-D8KR04 --- --- 10 to 65 mm 10 to 90 mm
0–4–8 4 8
4
8
X
YY
X
0–4–8–12 4
12
4
8
812
X
YY
X
0–5–10–15 5
10
15
5
10 15 X
YY
X
0–5–10–15 5 10 15 X
Y
X
5
10
15
Y
0–10–20–30 10 20 30
Y
X
10
20
30
X
Y
V600-HS51 & V600-D23P53 V600-HS51 & V600-D23P54 V600-HS51 & V600-D23P55
V600-HS51 & V600-D23P61 V600-HS51 & V600-D8KR12
6Intelligent Flag III V600-HAM42-DRT
Combinations with the V600-HS61 Sensor
Combinations with the V600-HS63 Sensor
0–5–10–15 5
10
15
5
10 15
Y
X
X
Y
0–4–8 4 8
Y
X
4
8
Y
X
0–4–8–12 4 8 12
Y
X
4
12
8
Y
X
0–5–10–15–20–25 5 10 15 20 25
Y
X
5
10
15
20
X
Y
0–10–20–30 10 20 30
Y
X
10
20
30
X
Y
0–10–20–30 10 20 30
Y
X
10
20
30
X
Y
V600-HS61 & V600-D23P53 V600-HS61 & V600-D23P54 V600-HS61 & V600-D23P55
V600-HS61 & V600-D23P61 V600-HS61 & V600-D23P72 V600-HS61 & V600-D8KR12
X0–10–20–30 10
20
30
10
20 30
YY
X
0–10–20–30–40 10 20 30 40
Y
X
10
20
30
X
Y
0–10–20–30–40–50 10 20 30 5040
Y
X
10
20
30
40
50 Y
X
X
0–10–20–30–4050 102030 5040
Y
X
10
20
30
40
50 Y
X
0–20–40–60 20 40 60
Y
X
20
40
60
X
Y
0–20–4060 204060
Y
X
20
40
60
X
Y
0–20–40–60 20 40 60
Y
X
20
40
60
Y
X
0–20–40–6080 20406080
Y
X
20
40
60
80
Y
X
0–20–40–60
80 20 40 60 80
Y
X
20
40
60
X
Y
V600-HS63 & V600-D23P55 V600-HS63 & V600-D23P61 V600-HS63 & V600-D23P66N
V600-HS63 & V600-D23P66SP V600-HS63 & V600-D23P71 V600-HS63 & V600-D23P72
V600-HS63 & V600-D8KR12 V600-HS63 & V600-D8KR13
V600-HS63 & V600-D2KR16
V600-HS63 & V600-D8KR04
0204060 20 40 60
Y
X
20
40
60
Y
X
Intelligent Flag III V600-HAM42-DRT 7
Combinations with the V600-HS67 Sensor
Transmission Time
The transmission time is the time required for transmission between the Sensor and the Data Carrier.
Battery-less type: V600-D23P53, V600-D23P54, V600-D23P55, V600-D23P61, V600-D23P66N, V600-D23P66SP, V600-D23P72, V600-
D23P71, V600-D23P72
Built-in battery type: V600-D8KR12, V600-D8KR13, V600-D8KR04, V600-D2KR16
Y
X
X020406080–20–40–60–80
60
20
40
Y
80
0–20–40–60–80 20 40 60 80
80
60
20
40
X
YY
XX
0–20–40–60–80–100 20 40 60 80 100
100
80
60
20
40
X
YY
X
0–20–40–60–80–100 20 40 60 80 100
100
80
60
20
40
X
YY
X
0–20–40–60–80 20 40 60 80
80
60
20
40
X
YY
X
0–20–40–60–80 20 40 60 80
80
60
20
40
X
YY
X
0–40–80
120 40 80 120
120
40
80
X
YY
X
V600-HS67 & V600-D23P66N V600-HS67 & V600-D23P66SP V600-HS67 & V600-D23P71
V600-HS67 & V600-D23P72 V600-HS67 & V600-D8KR12 V600-HS67 & V600-D8KR13
V600-HS67 & V600-D8KR04
Model V600-HAM42-DRT
Read Write
Mode type DATA READ mode BYTE mode BIT SET mode, BIT CLEAR
mode
Data Carrier type Battery-less type 79 ms 140 ms 152 ms
Built-in battery type 64 ms 97 ms 109 ms
8Intelligent Flag III V600-HAM42-DRT
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Amplifier
V600-HAM42-DRT
Sensor
V600-HS51
V600-HS61
35.2
24.1
23.3
2.2
7.3
4.9
23.15.5
38.85
48.6
65
4
8
50.85
65
42.5
2.2X7=15.4
40.3
7.67.6
3
60
48
66
55
55±0.2
16.7
Two, 4.5-dia. mounting holes
2-M4
35
Communications
connector
3-way operating
indicator
16-way operating
indicator
Three terminals Sensor connector
Mounting bracket
Mounting Hole Dimensions
35
49.5
33
7
M12X1
9.6 dia. 13.7 dia.
Vinyl-insulated round cord (4-mm dia.)
Connector
2 lock washers
2 lock nuts
49.5
30.5
18
18
10
4.5
8.5
6.5
13.7 dia.
Vinyl-insulated round cord (4-mm dia.
)
Connector
Detection surface
12±0.2
2-3.5X5
(mounting holes)
Intelligent Flag III V600-HAM42-DRT 9
V600-HS63
V600-HS67
V600-series Data Carrier
Built-in-battery DCs
V600-D8KR12 V600-D8KR04
51.5
10
2053
27 6
40 28
23
11
5
5
18
135
13.8 dia.
Two, 4.5-dia. mounting holes
Vinyl-insulated round cord 6-mm dia
(7/0.18-mm dia.), 8-conductor cable,
standard length: 2 m
Connector
4-R1 2-R5
Bushing
Power indicator (green)
Connector
Bushing
Vinyl-insulated round cord (6-mm dia.)
51.5
25
13.8 dia.
10
10
11
30
20
Power indicator
(green)
100
90±0.2
50
55
50
100
90±0.2
Four, 4.5-dia.
mounting holes
14
40 30±0.2
10
65
55±0.2
5
27 10
Two, 4.5-dia. mounting holes
15 8Case: ABS resin
Filler: Epoxy resin
54
20
44±0.2
10
86
31
Four, 4.5-dia. mounting holes
55 76±0.2
Case: ABS resin
Filler: Epoxy resin
10 Intelligent Flag III V600-HAM42-DRT
V600-D8KR13 Replaceable-battery DCs
V600-D2KR16
Battery-less DCs
V600-D23P66N
V600-D23P66SP
V600-D23P71
V600-D23P72
86
27 Two, 4.5-dia. mounting holes
10
54 44±0.2
10.3 5
576±0.2
10
Case: ABS resin
Filler: Epoxy resin
65
4-R1.5
40
5
R0.5 Case: ABS resin
5 0
– 0.1 6 0
– 0.2
5 0
– 0.1
24
2.2
6
36
30±0.1
24
R0.2
8 0
– 0.1 dia.
2-R1.0
R0.3
12 0
– 0.2 dia. R0.2
8 0
– 0.1 dia.
Two, 3.5-dia. mounting holes
V600-D23P53 V600-D23P54 V600-D23P55 V600-D23P61
Case: ABS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
Case: PPS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
4-R4
32
34
25±0.2 4-R3
32
34
25±0.2
Two, 6-dia.
3.5±0.1
Two, 3.5-dia.
25±0.2
25±0.2
2-M3
Case: PPS resin
Mounting Hole Dimensions
2-M5
4-R6
6.5
2.5 max.
34
36.5
34
80±0.2
95
1.3
80±0.2
Mounting Hole Dimensions
Coating: PFA resin
Two, 5.5-dia.
mounting holes
54
1.5
86
4-R2
Case: Glass epoxy resin
Coating: Polyurethane resin
50
4-R2
34
1.5
Case: Glass epoxy resin
Coating: Polyurethane resin
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of
sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate
catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use
of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the
products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,
and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or
proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. Q115-E1-02
Printed in Japan
1004 (0203)
OMRON Corporation
Industrial Automation Company
Application Sensors Division
Sensing Devices and Components Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
2007.3
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.