SWS Series Single Output General Purpose Power Supplies Low Cost Power Factor Correction to EN61000-3-2 Universal Input (85 - 265VAC) Input Transient Protected IEC61000-4 Enclosed Key Market Segments & Applications SWS Features and Benefits Feature Meets IEC61000-4 Global safety Approvals Power Factor Corrected Level B EMI Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Test & Measurement Burn-in & Test, Automated, Detection Test, Instrumentation, Measurement Automated Service Vending Machines, Elevators, Video Gaming, Point of Sale Equipment Benefit Greater reliability Supports Global Use Supports Global Use Assists System Compliance Specifications MODEL ITEMS Input Voltage range (1) Inrush Current (115/230VAC) A Power Factor Input Current (115/230VAC) A Temperature Coefficient Total Regulation Overcurrent Protection Overvoltage Protection V Hold Up Time (Typ) ms Leakage Current (typ@230VAC) mA Remote Sense LED Indicator Operating Temperature Storage Temperature Operating Humidity (2) Storage Humidity (2) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Recommended EMI Filter Immunity Weight (Typ) g Size (WxHxD) in Warranty (1) Derate to 85% load below 100VAC input SWS50 SWS75 SWS100 SWS150 85 - 265VAC (47 - 63Hz) or 120 - 370VDC 20/40 16/32 Meets EN61000-3-2 1.2/0.6 1.6/0.8 1.2/0.6 1.8/0.9 <0.02%/C <5% >105%, Constant Current Style 115 -135%, Cycle AC line to reset 20ms at 115VAC 0.6 Not Available Green LED = On -10 to +70C (See table for derating - model specific) -30 to +85C 30 - 90% RH 10 - 95% RH Convection Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 19.6m/s2(10 - 55Hz (constant sweep 1 min) X, Y, Z for 1 hour) < 196.1 m/s2 (20G) UL60950, CSA60950, EN60950, CE Mark, EN50178 EN55011 / EN55022-B, FCC Class B, VCCI-B MAW1202-22 MAW1203-22 MAW1202-22 MAW1203-22 EN61000-4-2,-3,-4,-5,-6,-8,-11 400 480 600 750 3.62 x 1.46 x 6.26 3.7 x 1.69 x 6.69 3.78 x 1.77 x 7.4 3.9 x 2 x 7.8 Two Years (2) non condensing 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 SWS Series Model Selector Model Voltage SWS50-3 SWS75-3 SWS100-3 SWS150-3 SWS50-5 SWS75-5 SWS100-5 SWS150-5 SWS50-12 SWS75-12 SWS100-12 SWS150-12 SWS50-15 SWS75-15 SWS100-15 SWS150-15 SWS50-24 SWS75-24 SWS100-24 SWS150-24 3.3V 3.3V 3.3V 3.3V 5V 5V 5V 5V 12V 12V 12V 12V 15V 15V 15V 15V 24V 24V 24V 24V SWS50 Outline Drawing Adjust Range Max Load Line Ripple Eff. Curr. Reg mV Reg mV Noise (typ)% 3-3.6V 3-3.6V 3-3.6V 3-3.6V 4.5-5.5V 4.5-5.5V 4.5-5.5V 4.5-5.5V 10.8-13.2V 10.8-13.2V 10.8-13.2V 10.8-13.2V 13.5-16.5V 13.5-16.5V 13.5-16.5V 13.5-16.5V 21.6-26.4V 21.6-26.4V 21.6-26.4V 21.6-26.4V Veritcal Mount Convection 25C 30C SWS50 100% 100% SWS75 (5V model) 100% 100% SWS75 (12V & 24V) 100% 100% SWS100 100% 100% SWS150 (5V model) 100% 95% SWS150 (12V & 24V) 100% 100% 1.2m/s Forced Air 50C 35C 100% 100% 100% 100% 90% 100% 55C SWS50 SWS75 SWS100 SWS150 100% 100% 100% 100% 100% 100% 100% 100% 10 15 20 30 10 15 20 30 4.3 6.3 8.5 12.5 3.5 5 6.7 10 2.1 3.2 4.3 6.3 40 40 40 40 50 50 40 40 96 96 96 96 120 120 120 120 144 144 144 144 20 20 20 20 20 20 20 20 48 48 48 48 60 60 60 60 96 96 96 96 80 80 100 100 80 80 100 100 80 80 100 100 100 100 100 100 100 100 150 150 73/70 72/68 69/70 70/72 77/75 77/74 75/77 76/78 82/79 83/81 79/81 79/82 84/80 85/82 81/83 81/83 84/80 85/82 82/84 82/85 SWS75 Outline Drawing 40C 45C 50C 55C 60C 100% 100% 100% 93% 85% 100% 93% 85% 73% 60% 100% 100% 93% 85% 60% 100% 100% 87% 73% 60% 85% 73% 60% 100% 100% 100% 80% 60% 60C 65C 70C 100% 90% 90% 90% 80% 80% 80% 70% 70% 70% Derate to 80% load from 0 to -10C SWS150 Outline Drawing SWS100 Outline Drawing Other Lambda Industrial Products RWS JWS, JWS-P & JWT JFS 15W & 30W Single output 50W to 600W Single and triple output 500W to 2000W Single output For Additional Information, please visit www.lambdapower.com/products/sws-series.htm 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 Revision A3: October 2004