Semiconductor Fuses DC Fuses Ferrule Fuses 2000V DC 2000 V DC gRB from 0.8 to 40 A Size 36 x 250 Dimensions blow Fuse indicator version = CC 209P 255 43 20 o12 CC 209P ... o 36 Weight 622 g Standard version without indicator = CC 2000 250 CC 2000 ... o 36 Weight 622 g Trip force: 15 N at 20 mm MAIN CHARACTERISTICS Size Current rating IN( A ) 36x250 0.8 1 1.5 2 3.15 4 5 6 8 10 12 16 20 25 32 40 10 12 20 25 32 40 Interrupting rating @ 2000 V DC 30 kA L/R = 20 ms Watts loss 0.8 IN IN 1 1.1 1.8 2 2.8 4 5 5.3 6 7 7.6 10.5 10 12 15.2 19.6 7.0 7.6 10 12 15.2 19.6 1.8 2 3 3.3 5 7 8.8 9 10 12 13 18 17.5 21 26 33.6 12 13 17.5 21 26 33.6 Catalog Number Ref number Pack. CC 2000 CP gRB 36x250/0.8 CC 2000 CP gRB 36x250/1 CC 2000 CP gRB 36x250/1.5 CC 2000 CP gRB 36x250/2 CC 2000 CP gRB 36x250/3.15 CC 2000 CP gRB 36x250/4 CC 2000 CP gRB 36x250/5 CC 2000 CP gRB 36x250/6 CC 2000 CP gRB 36x250/8 CC 2000 CP gRB 36x250/10 CC 2000 CP gRB 36x250/12 CC 2000 CP gRB 36x250/16 CC 2000 CP gRB 36x250/20 CC 2000 CP gRB 36x250/25 CC 2000 CP gRB 36x250/32 CC 2000 CP gRB 36x250/40 CC 209P CP gRB 36x250/10 CC 209P CP gRB 36x250/12 CC 209P CP gRB 36x250/20 CC 209P CP gRB 36x250/25 CC 209P CP gRB 36x250/32 CC 209P CP gRB 36x250/40 P 221135 R 093096 S 093097 T 093098 V 093099 N 084951 Q 221136 S 084955 V 090339 H 093157 3 W 093100 X 093101 pieces H 086257 Y 081441 X 081440 W 081439 L 084949 M 098497 M 084950 R 087461 L 081131 W 087373 Minimum trip voltage: 90 V These fuses can be fitted with a MC 1-5 Flex. microswitch (see Medium Voltage section) See Fuse Blocks and Fuse Holders, and Medium Voltage fuse clips 383 Semiconductor Fuses DC Fuses Ferrule Fuses 2000V DC ELECTRICAL CHARACTERISTICS DC application data Peak arc voltage vs. working voltage L/R (ms) Um(V) 90 80 70 60 50 40 30 20 10 0 1 4000 2 3000 U (V) 2000 1500 1000 1600 U (V) 500 2400 2300 2200 2100 2000 1900 1800 1700 1600 1500 1400 2000 1 : L/R = 45 ms 2 : L/R = 15 ms Above: Curve indicates the maximum permissible value of time constant L/R as a function of DC working voltage Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage Max. AC voltage (50/60 Hz): 3,000 V with interrupting rating of 50 kA 20 a= 130 A2=0.6 B1= 1.25 B2= 0.6 Cf3= 0.8 10 3 10 2 40 32 25 16 10 12 8 5 6 3.15 10 4 1.5 0.8 1 2 t (s) 4 Time vs. current characteristics a= 130 A2=0.6 B1= 1.25 B2= 0.6 Cf3= 0.8 a= 130 A2=0.6 B1= 1.25 B2= 0.6 Cf3= 0.8 10 1 10 -1 10 -2 10 -3 10 -4 1 10 10 2 10 3 1 10 2 10 Above: These curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. 384 10 3 1 10 10% tolerance for mean pre-arcing current 10 2 10 3 I (A)