Quick Start Procedure
Refer to Figure 1 for proper measurement equipment setup and follow the procedure below:
1. Set the jumpers on the board as follows:
VRON DPSLP# DPRSLPVR GMUXSEL
OFF ON OFF ON
VID0 VID1 VID2 VID3 VID4
OFF OFF OFF ON ON
DLC ON
ON
VBIAS
E
FCB
L
2. Apply input voltage 7~24V across the VIN+ and VIN– terminals.
3. Apply +3.3V logic voltage across +3.3V and SGND terminals.
4. Apply 5V across EXTVCC and SGND terminals if needed.
5. Select VID code using the jumpers VID0–VID4.
6. Select the GMUXSEL/DPRSLPVR/DPSLP# combination using the appropriate jumpers.
7. Replace the VRON jumper
8. Apply the test load across VCC+ and VCC–. Do not exceed a 25A load.
Transient Test
This demo board has a built-in dynamic load test circuit. To test load transients, review Figure 1
and follow this procedure:
1. Shut down the converter by removing the VRON jumper.
2. Apply ±12V supply to the +12V, PGND and –12V terminals.
3. To monitor load current waveforms, connect an oscilloscope to J5 (BNC terminal).
4. Replace the VRON jumper.
5. Remove the DLC ON (Dynamic Load Circuit) jumper.
6. Tune R41, R43 and R39 to program the step amplitude, up-slope and down-slope of the load
step, respectively.
DC377B-A Quick Start Guide Page 2 of 3