1 Pt100 KN 1510 E
The KN Series Ceramic Wire Wound PRTDs are suitable for
general applications requiring temperature stability.
Applications: Industrial resistance thermometers, especially
in chemical, power generation plants and analytical
equipment.
Construction: A platinum coil is sealed inside a high purity
aluminum oxide ceramic body. Lead wires are shear force
resistant and assure proper connection to extension leads
and cables.
Models
1Pt100 KN 1510 E
32.206.681
32.206.682
32.206.683
W0.3
W0.15
W0.1
15+2
- 0 10.0±0.5
1.0±0.15 0.20±0.01
Temperature stability:
Excellent long-term stability
Tolerance class:
Also available:
Temperature range:
Temperature
coefficient: Tc = 3916 ppm/K
Leads: Palladium-gold alloy
Measuring current: 1 mA
Insulation resistance
after assembly: > 100 MOhm @ 25 °C
Nominal resistance:
100 Ohm @ 0 °C
W0.3 (Class B) = -196 to +660 °C
W0.15 (Class A) = -196 to +600 °C
W0.1 (Class 1/3 B) = -100 to +350 °C
- According to old JIS
- Other standards and narrower
tolerances are available on request
- Platinum-gold alloy
- Different temperature coefficients
(3850 ppm/K - IEC 60751:2008)
- Extension leads
- Two separated coils can be embedded
in one ceramic body
The measuring point is located at 8 mm from the end of the sensor body
Models
Technical Specification
0.14 0.2 3.0 9.0 0.3
Status 01/2009. Technical modifications reserved.
Self Heating
0°C (K/mW) Water current
V=0.4m/s
Air stream
V=3m/s
t
0.5 t
0.9 t 0.9
t
0.5
Description Tolerance
IEC 60751 Order No. Dimensions
mm
L D d l
Response time
Status: HSTUSA 10/09
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400 Fax 732-940-4445
Email info.hst-us@heraeus.com
www.hst-us.com
Heraeus Sensor Technology USA
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Heraeus:
32206683 32206682 32206681