2-line filters SIFI-G for enhanced insertion loss 250 V DC/AC, 50/60 Hz, 3 ... 36 A Series/Type: B84112G0000* Date: 2008-10-01 Version: 09 EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Construction 2-line filter Metal case Polyurethane potting (UL 94 V-0) Features Easy to install Compact design Cost optimized construction Medical version with low leakage current ENEC10, UL and cUL approval c us Applications Switched-mode power supplies for - industrial electronics - telecom systems - data systems DC applications Medical engineering Type M Terminals Filters up to 16A tab connectors 6.3 x 0.8 mm Threaded studs M5 for filters from 20A to 36A Marking Marking on component: manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: maufacturer's logo, ordering code, date code, quantity Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Typical circuit diagram of B84112G0000B* and B84112G0000G* LINE LOAD L L' PE N N' Technical data and measuring conditions of B84112G0000B* and B84112G0000G* Rated voltage UR 250 V DC/AC Rated frequency fR 50/60 Hz Test voltage line to line for 2 s Utest 1770 V DC Test voltage line to case for 2 s Utest 2700 V DC Leakage current Ileak At 230 V AC, 50 Hz Rated temperature TR 40 Climatic category (IEC 60068-1) Please read and Cautions and warnings and Important notes at the end of this document. C 25/100/21 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Typical circuit diagram of B84112G0000M* (for medical applications) LINE LOAD L L' PE N N' Technical data and measuring conditions of B84112G0000M* Rated voltage UR 250 V DC/AC Rated frequency fR 50/60 Hz Test voltage line to line for 2 s Utest 1770 V DC Test voltage line to case for 2 s Utest 2500 V AC Leakage current Ileak At 230 V AC, 50 Hz Rated temperature TR 40 Climatic category (IEC 60068-1) Please read and Cautions and warnings and Important notes at the end of this document. C 25/100/21 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Characteristics and ordering codes of B84112G0000B* and B84112G0000G* IR CR A LR Ileak mH mA Case Approx. Ordering code style weight Approvals g 3 2 x 0,22 F (X2) 2 x 10 < 0,5 2 x 4700 pF (Y2) 1 200 B84112G0000B030 6 2 x 0,47 F (X2) 2 x 3,3 < 0,5 2 x 4700 pF (Y2) 1 200 B84112G0000B060 10 2 x 0,68 F (X2) 2 x 1,8 < 0,5 2 x 4700 pF (Y2) 1 200 B84112G0000B110 16 2 x 0,47 F (X2) 2 x 1,8 < 0,5 2 x 4700 pF (Y2) 1 210 B84112G0000B116 20 2 x 1,0 F (X2) 2 x 1,8 < 0,5 2 x 4700 pF (Y2) 2 440 B84112G0000G120 25 2 x 1,0 F (X2) 2 x 1,6 < 0,5 2 x 4700 pF (Y2) 2 440 B84112G0000G125 36 2 x 1,5 F (X2) 2 x 0,8 < 0,5 2 x 4700 pF (Y2) 2 470 B84112G0000G136 X X X X X X X X X X X X X X X X X X X X X Characteristics and ordering codes of B84112G0000M* IR CR A LR Ileak mH A Case Approx. Ordering code style weight Approvals g 3 2 x 0,22 F (X2) 2 x 10 <2 1 200 B84112G0000M030 X X X 6 2 x 0,47 F (X2) 2 x 3,3 <2 1 200 B84112G0000M060 X X X 10 2 x 0,68 F (X2) 2 x 1,8 <2 1 200 B84112G0000M110 X X X 16 2 x 0,47 F (X2) 2 x 1,8 <2 1 210 B84112G0000M116 X X X 20 2 x 1,0 F (X2) 2 x 1,8 <2 2 440 B84112G0000M120 X X X 25 2 x 1,0 F (X2) 2 x 1,6 <2 2 440 B84112G0000M125 X X X 36 2 x 1,5 F (X2) 2 x 0,8 <2 2 470 B84112G0000M136 X X X X = approval granted Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Dimensional drawing (case style 1) B84112G0000B030...B84112G0000B116 B84112G0000M030...B84112G0000M116 X Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Dimensional drawing (case style 2) B84112G0000G120...B84112G0000G136 B84112G0000M120...B84112G0000M136 Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84112G0000B030 B84112G0000B060 100 dB 100 dB 80 80 60 60 40 40 20 20 0 104 105 106 107 0 104 Hz 108 105 106 107 f Hz 108 f B84112G0000B110 B84112G0000B116 100 dB 100 dB 80 80 60 60 40 40 20 20 0 104 105 106 107 Hz 108 f Please read and Cautions and warnings and Important notes at the end of this document. 0 104 105 106 107 Hz 108 f 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84112G0000G120 B84112G0000G125 100 dB 100 dB 80 80 60 60 40 40 20 20 0 104 105 106 107 Hz 108 f 0 104 105 106 107 Hz 108 f B84112G0000G136 100 dB 80 60 40 20 0 104 105 106 107 Hz 108 f Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84112G0000M030 B84112G0000M060 100 dB 100 dB 80 80 60 60 40 40 20 20 0 104 105 106 107 0 104 Hz 108 105 106 107 f Hz 108 f B84112G0000M110 B84112G0000M116 100 dB 100 dB 80 80 60 60 40 40 20 20 0 104 105 106 107 Hz 108 f Please read and Cautions and warnings and Important notes at the end of this document. 0 104 105 106 107 Hz 108 f 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84112G0000M120 B84112G0000M125 100 dB 100 dB 80 80 60 60 40 40 20 20 0 104 105 106 107 Hz 108 f 0 104 105 106 107 Hz 108 f B84112G0000M136 100 dB 80 60 40 20 0 104 105 106 107 Hz 108 f Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Caution and warnings Please note the advices in our data book "EMC Filters" (latest edition); attention should be paid to the chapter "General safety notes". It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter housing). EMC filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective. In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents IL 4) < 10 mA the PE conductor must have a KU value 3) of 4.5; for leakage currents IL 10 mA the PE conductor must have a KU value of 6. 3) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous body currents and excessive heating. A value of KU = 4.5 with respect to interruptions is attained: - with a permanently connected protective earth circuit 1.5 mm2 - with a protective earth circuit 2.5 mm2 connected via shroud connectors (IEC 60309-2). KU = 6 with respect to interruptions is achieved for fixed-connection lines 10 mm2 where the type of connection and line layout correspond to the requirements for PEN conductors as specified in relevant standards. 4) IL = leakage current let-go Please read and Cautions and warnings and Important notes at the end of this document. 2-line filters B84112G0000* SIFI-G for enhanced insertion loss Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statement cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before end of their usual service life time cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCAP, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 1 Please read and Cautions and warnings and Important notes at the end of this document. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: EPCOS: B84112GB110 B84112GB116 B84112GB30 B84112GB60 B84112GG120 B84112GG125 B84112GG136 B84112G0000M030 B84112G0000M060 B84112G0000M110 B84112G0000M116