Power
supplies
Low Voltage Products & Systems 11.25
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202
11
Data at Ta = 25 °C, UIN = 230 V AC and rated values, if nothing else indicated
Type CP-C 24/5.0
CP-S 24/5.0
CP-C 24/10.0
CP-S 24/10.0
CP-C 24/20.0
CP-S 24/20.0
Input circuit - supply circuit L, N
Rated input voltage UIN CP-C 110-240 V AC
CP-S switch position 115 110-240 V AC 110-120 V AC
switch position 230 220-240 V AC
Input voltage range CP-C 85-264 V AC / 100-350 V DC 1)
CP-S switch position 115 85-264 V AC /
100-350 V DC 1)
85-132 V AC
switch position 230 184-264 V AC / 220-350 V DC 1)
Frequency range AC 47-63 Hz
Current consumption at 110-240 V AC approx. 2.2-1.2 A approx. 3.5-1.6 A approx. 5.5-2.5 A
at 110-120 V AC - approx. 4.2-4.0 A approx. 9.0-8.0 A
at 220-240 V AC - approx. 2.4-2.2 A approx. 4.5-4.0 A
Power consumption typ. 135 W typ. 269 W typ. 538 W
Inrush current / I2t ( cold start) CP-C < 23 A / approx. 0.9 A2s< 33 A / approx. 0.2 A2s< 40 A / approx. 1.9 A2s
CP-S < 40 A / approx. 1.8 A2s< 70 A / approx. 8 A2s
Power failure buffering at rated load CP-C > 100 ms > 40 ms typ. > 40 ms
CP-S > 50 ms typ. > 50 ms
Transient overvoltage protection varistors
Internal input fuse (apparatus protection, not accessible) 4 A (slow-acting) 6.3 A (slow-acting) 12 A (fast-acting)
Indication of operational states
Output voltage OUTPUT OK: green LED V: output voltage OK
Output circuit L+, L+, L-, L- : short-circuit, no-load and overload proof
Rated output voltage 24 V DC
Tolerance of the output voltage CP-C w1 %
CP-S -1...+5 %
Adjustment range of the output
voltage
CP-C 22-28 V DC, default setting 24 V w0.5 %
CP-S xed
Rated output power 120 W 240 W 480 W
Rated output current Ta < 60 °C 5 A 10 A 20 A
Peack output current (power reserve) Ta < 40 °C typ. m 7.25 A typ. m 12.25 A typ. m 22.5 A
Derating 60 °C < Ta < 70 °C 2.5 % per Kelvin temperature increase
Deviation with CP-C load change statical typ. < w0.05 %
CP-S load change statical typ. < w0.1 %
load change dynamical 10-90 % typ. < w3 %
change of the input voltage of w10 % typ. < w0,05 %
Control time typ. < 1 ms
Starting time after applying
supply voltage
CP-C < 100 ms < 5 ms typ. < 370 ms
CP-S < 10 ms typ. < 20 ms
Response time 10-90 % CP-C typ. < 30
ms
typ. < 4 ms typ. < 12 ms
CP-S
typ. < 5 ms
typ. < 15 ms
Residual ripple and switching peaks 20 MHz typ. < 50 mVPP
Parallel connection yes, up to 5 devices, to enable redundancy and to increase
capacity, current not symmetrical (CP-S only redundancy)
Series connection yes, to increase voltage
Resistance to reverse feed approx. 35 V DC
Power factor correction (PFC) CP-C yes
CP-S no
Output circuit - No-load, overload and short-circuit behaviour see also U/I and I/T curves
Output curve U/I curve with power reserve
Current limitation at short circuit approx. 11 A approx. 19 A approx. 25 A
Short-circuit protection continuous short-circuit stability
Overload protection thermal protection
Starting of capacitive loads unlimited
General data
Power dissipation typ. < 15 W typ. < 29 W typ. < 58 W
Efciency typ. 88-89 %
Discharge current for PE < 3.5 mA
MTBF CP-C 500.000 h
CP-S 350.000 h
Dimensions (W x H x D) 56.5 (60 2)) x 130 x 137
mm [2.22 (2.36 2)) x 5.12
x 5.39 in]
90 (93.5 2)) x 130x 137
mm [3.54 (3.68 2)) x 5.12
x 5.39 in]
200 (203.5 2)) x 130 x 137
mm [7.87 (8.01 2)) x 5.12
x 5.39 in]
Technical data
CP-S, CP-C & CP-A Range