Switched mode Power supplies Switched mode power supplies CP Range Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage P su owe pp r lie s 11 Special features of CP range primary switch power supplies * Primary switch mode power supplies - High efficiency of approximately 90 % - Low power dissipation and low heating - Long lifetime * Open-circuit, overload and short-circuit proof * Integrated input fuse * Wide range of AC or DC supply voltages - World wide use also in high fluctuating networks and battery-powered plants * Safety - Closed construction - Touch-proof connecting terminals - Electrical isolation * Constant or adjustable output voltage (depending on type) * Easy and fast mounting - Mounting on DIN rail * Use in very harsh industrial environments - Reliable construction - According to EMC Directives EN 61000-6-2 (Interference immunity) and EN 61000-6-4 (Interference emission) * Status LED * Example of application - Supply of programmable logic controllers (PLC) e. g. AC31, AC500 11.1 1SXU000023C0202 Primary switch mode power supplies CP Range Overview, Conversion table r we ies o P pl p su Overview Rated input voltage CP-D CP-E CP-S CP-C 100-240 V AC all CP-D all CP-E - - 110-240 V AC - - CP-S 24/5.0 all CP-C - 110-120 V AC / 220-240 V AC - - CP-S 24/10.0 CP-S 24/20.0 5 V DC - 3.0 A CP-E 5/3.0 - - 12 V DC 0.83 A (CP-D 12/0.83) 2.1 A (CP-D 12/2.1) 2.5 A (CP-E 12/2.5) - - 24 V DC 0.42 A (CP-D 24/0.42) 1.3 A (CP-D 24/1.3) 2.5 A (CP-D 24/2.5) 4.2 A (CP-D 24/4.2) 0.75 A (CP-E 24/0.75) 1.25 A CP-E 24/1.25) 2.5 A (CP-E 24/2.5) 5 A (CP-S 24/5.0) 10 A (CP-S 24/10.0 20 A (CP-S 24/20.0) 5 A (CP-C 24/5.0) 10 A (CP-C 24/10.0 20 A (CP-C 24/20.0) 48 V DC - 0.625 A (CP-E 48/0.62) 1.25 A (CP-E 48/1.25) - - 10 W CP-D 12/0.83 CP-D 24/0.42 - - - 15 W - CP-E 5/3.0 - - 18 W - CP-E 24/0.75 - - 30 W CP-D 12/2.1 CP-D 24/1.3 CP-E 12/2.5 CP-E 24/1.25 CP-E 48/0.62 - - 60 W CP-D 24/2.5 CP-E 24/2.5 CP-E 48/1.25 - - 100 W CP-D 24/4.2 - - - 120 W - - CP-S 24/5.0 CP-C 24/5.0 240 W - - CP-S 24/10.0 CP-C 24/10.0 480 W - - CP-S 24/20.0 CP-C 24/20.0 CP-A RU (+ CP-A CM) CP-C MM Rated output voltage / current 11 Rated output power Expandable Redundancy unit (+ Control module) - CP-RUD CP-A RU (+ CP-A CM) Messaging module - - - Conversion table: CP to CP-E, CP-S, CP-C Type old Order code old Type new / alternative Order code new / alternative Rated output voltage 5 V DC CP-5/3.0 1SVR 423 418 R3000 CP-E 5/3.0 1SVR 423 418 R4000 CP-E 5/3.0 Order code old 1SVR 427 033 R3000 Rated output voltage 12 V DC CP-12/2.0 1SVR 423 418 R1000 CP-E 12/2.5 1SVR 427 032 R1000 CP-12/2.0 adj 1SVR 423 418 R1100 CP-E 12/2.5 1SVR 427 032 R1000 Rated output voltage 24 V DC 1SVR 423 416 R1000 CP-S 24/5.0 1SVR 427 014 R0000 CP-24/5.0 1SVR 423 416 R0000 CP-S 24/5.0 1SVR 427 014 R0000 CP-24/1.5 adj 1SVR 423 418 R5000 CP-E 24/2.5 1SVR 427 032 R0000 CP-24/2.0 adj 1SVR 423 417 R1100 CP-E 24/2.5 1SVR 427 032 R0000 CP-24/5.0 adj 1SVR 423 416 R0100 CP-C 24/5.0 CP-S 24/5.0 1SVR 427 024 R0000 1SVR 427 014 R0000 CP-24/10 adj 1SVR 423 415 R0000 CP-C 24/10.0 CP-S 24/10.0 1SVR 427 025 R0000 1SVR 427 015 R0100 CP-24/20 adj 1SVR 423 415 R1000 CP-C 24/20.0 CP-S 24/20.0 1SVR 427 026 R0000 1SVR 427 016 R0100 1SVR 423 418 R2000 CP-E 24/0.75 1SVR 427 030 R0000 CP-24/0.5 1SVR 423 414 R0000 CP-E 24/0.75 1SVR 427 030 R0000 Rated output voltage 48 V DC CP-24/1.0 1SVR 423 418 R0000 CP-E 24/1.25 1SVR 427 031 R0000 CP-48/0.7 CP-24/2.0 1SVR 423 417 R0000 CP-E 24/2.5 1SVR 427 032 R0000 CP-24/2.0 1SVR 423 417 R1000 CP-E 24/2.5 1SVR 427 032 R0000 1SXU000023C0202 Order code new / alternative CP-24/4.2 CP-24/0.3 11.2 Type new / alternative Rated output voltage 24 V DC 1SVR 427 033 R3000 Rated output voltage 6 V DC CP-6/3.0 Type old 1SVR 423 418 R6000 CP-E 48/1.25 CP-E 48/0.62 1SVR 427 031 R2000 1SVR 427 030 R2000 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Primary switch mode power supplies CP range Approvals and marks existing pending CP-D 12/0.83 CP-D 12/2.1 CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 CP-D UL 508, CAN/CSA C22.2 No.14 1) 1) 1) 1) 1) 1) H UL 1310, CAN/CSA C22.2 No.223 (Class 2 Power Supply) 1) 1) 1) 1) 1) H UL 60950, CAN/CSA C22.2 No.60950 1) 1) 1) 1) 1) Approvals A P su owe pp r lie s 1) D GOST E CCC 1) 1) 1) 1) 1) 1) Marks a CE b C-Tick existing pending CP-E 24/1.25 CP-E 24/2.5 CP-E 48/0.62 CP-E 48/1.25 1) 1) 1) 1) 1) 1) 1) H UL 1310, CAN/CSA C22.2 No.223 (Class 2 Power Supply) B ANSI/ISA-12.12 (Class I, Div.2, hazardous locations) 1) 1) 1) 1) 1) 1) 1) H UL 60950, CAN/CSA C22.2 No.60950 D GOST E CCC 1) 1) 1) 1) 1) 1) 1) CP-RUD CP-E 24/0.75 UL 508, CAN/CSA C22.2 No.14 CP-E 12/2.5 A CP-E 5/3.0 Approvals CP-E 11 Marks a CE b C-Tick existing pending CP-S 24/20.0 CP-C 24/5.0 CP-C 24/10.0 CP-C 24/20.0 CP-C MM CP-A RU CP-A CM CP-A CP-S 24/10.0 CP-C CP-S 24/5.0 CP-S A UL 508, CAN/CSA C22.2 No.14 1) 1) 1) 1) 1) 1) A UL 1604 (Class I, Div. 2, hazardous locations), CAN/CSA C22.2 No.213 1) 1) 1) 1) 1) 1) UL 60950, CAN/CSA C22.2 No.60950 1) 1) 1) 1) 1) 1) Approvals H D GOST K CB scheme E CCC 1) 1) 1) 1) Marks 1) a CE b C-Tick Approvals refer to the rated input voltage UIN. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 11.3 1SXU000023C0202 r we ies o P pl p su Notes 11 11.4 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Switched mode power supplies CP-D Range Adjustable output voltage The CP-D range types > 10 W feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. Width and structural form With their width between 18 to 90 mm only, the CP-D range switch mode power supplies are ideally suited for installation in distribution panels. P su owe pp r lie s * Output voltages 12 V, 24 V * Adjustable output voltages (devices > 10 W) * Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A * Power range 10 W, 30 W, 60 W, 100 W * Wide range input 100-240 V AC (90-264 V AC, 120-370 V DC) * High efficiency of up to 89 % * Low power dissipation and low heating * Free convection cooling (no forced cooling with ventilators) * Ambient temperature range during operation -10...+70 C * Open-circuit, overload and short-circuit stable * Integrated input fuse * U/I characteristic (fold-forward behavior at overload - no switch-off) * LEDs for status indication * Light-grey enclosure in RAL 7035 * Approvals / Marks A, H, D, E / a, b Wide range input Optimised for world-wide applications: The CP-D power supplies can be supplied with 90-264 V AC or 120-370 V DC. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 11.5 1SXU000023C0202 11 r we ies o P pl p su Power supplies CP-D Rated input voltage Rated output voltage / current Order code Pack. unit pieces Weight 1 piece kg / lb CP-D 12/0.83 100-240 V AC 12 V DC / 0.83 A 1SVR 427 041 R1000 1 0.06 / 0.13 CP-D 12/2.1 100-240 V AC 12 V DC / 2.1 A 1SVR 427 043 R1200 1 0.19 / 0.41 CP-D 24/0.42 100-240 V AC 24 V DC / 0.42 A 1SVR 427 041 R0000 1 0.06 / 0.13 CP-D 24/1.3 100-240 V AC 24 V DC / 1.3 A 1SVR 427 043 R0100 1 0.19 / 0.41 CP-D 24/2.5 100-240 V AC 24 V DC / 2.5 A 1SVR 427 044 R0200 1 0.25 / 0.55 CP-D 24/4.2 100-240 V AC 24 V DC / 4.2 A 1SVR 427 045 R0400 1 0.32 / 0.71 Type CP-D 12/0.83, CP-D 24/0.42 11 CP-D 12/2.1 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 11.6 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-D range P su owe pp r lie s Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-D 12/0.83 CP-D 12/2.1 Input circuit - supply circuit L, N Rated input voltage UIN 100-240 V AC Input voltage range 90-264 V AC / 120-370 V DC Frequency range AC 47-63 Hz Typical input current / typical power consumption at 110 V AC 200 mA / 12.68 W 502 mA / 31.14 W at 230 V AC 128.3 mA / 13.01 W 277 mA / 31.2 W Inrush current at 230 V AC 30 A (max. 3 ms) Power failure buffering 50 A (max. 3 ms) > 30 ms Internal input fuse 1 A slow-acting / 250 V AC 2 A slow-acting / 250 V AC Indication of operational states Output voltage V: output voltage applied V: output voltage too low DC ON: green LED DC LOW: red LED Output circuit +, - ++, -- Rated output voltage 12 V DC Tolerance of the output voltage 1 % Adjustment range of the output voltage Rated output power Rated output current Ir Ta m 60 C - 12-14 V DC 10 W 30 W 0.83 A 2.1 A 60 C < Ta m 70 C Derating of the output current Deviation with load change 2.5 %/K statical 11 max. 1 % dynamical 10-90% change of input voltage within the input voltage range max. 1 % Control time < 1 ms Starting time after applying the supply voltage Response time Residual ripple and switching peaks at Ir 1000 ms at rated load typ. 1 ms BW = 20 MHz 50 mV Parallel connection no Series connection yes, to increase voltage Resistance to reverse feed 18 V / 1 s Power factor correction (PFC) no Output circuit - No-load, overload and short-circuit behaviour Output curve U/I curve Short-circuit protection continuous short-circuit statility Short-circuit behaviour continuation with current limitation Current limitation at short circuit typ. 1.4 A typ. 5.9 A Overload protection current limitation No-load protection continuous no-load stability Starting of capacitive loads unlimited Gerneral data Efficiency typ. 78 % Duty time Dimensions (WxHxD) 18 x 91 x 57.5 mm [0.71 x 3.58 x 2.26 in] Weight DIN rail (EN 60715), snap-on mounting without any tool Mounting position Protection class Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 0.19 kg (0.41 lb) plastic Mounting Degree of protection 53 x 91 x 57.5 mm [2.09 x 3.58 x 2.26 in] 0.06 kg (0.13 lb) Material of enclosure Minimum distance to other units typ. 82 % 100 % horizontal horizontal / vertical enclosure / terminals 25 mm / 25 mm (0.98 in / 0.98 in) IP20 / IP20 II 11.7 1SXU000023C0202 r we ies o P pl p su Technical data CP-D range Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-D 12/0.83 CP-D 12/2.1 Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule 0.2-2 mm2 (24-14 AWG) rigid Stripping length 6 mm (0.24 in) Tightening torque 0.36-0.56 Nm Environmental data Ambient temperature range operation -25...+70 C full load -25...+60 C storage -25...+85 C Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 C, 95 % RH Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s2, 10 Hz - 2 kHz 40 m/s2, 22 ms Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC Pollution category 2 Standards Product standard EN 61204 Low Voltage Directive 11 2006/95/EC EMC Directive 2004/108/EC Electrical safety UL 508, UL 60950-1, EN 60950-1 Protective low voltage SELV (EN 60950-1) Electromagnetic compatibility Interference immunity EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 4 (4 kV / 8 kV) Level 4 (8 kV / 15 kV) Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000-4-4 Level 4 (4 kV) powerful impulses (Surge) IEC/EN 61000-4-5 Level 4 (2 kV L-L) HF line emission IEC/EN 61000-4-6 Interference emission Level 3 (10 V) EN 61000-6-3 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 11.8 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-D range P su owe pp r lie s Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 Input circuit - supply circuit CP-D 24/4.2 L, N Rated input voltage UIN 100-240 V AC Input voltage range 90-265 V AC / 120-370 V DC Frequency range AC 47-63 Hz Typical input current / typical power consumption at 110 V AC Inrush current 184 mA / 11.62 W 600 mA / 37.92 W 1120 mA / 69.3 W at 230 V AC 120.6 mA / 12 W 344 mA / 38.16 W at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms) Power failure buffering 660 mA / 70.1 W 1 A slow-acting / 250 V AC 900 mA / 114.4 W 60 A (max. 3 ms) > 30 ms Internal input fuse 1800 mA / 117.3 W > 60 ms 2 A slow-acting / 250 V AC 3.15 A slow-acting / 250 V AC Indication of operational states Output voltage V: output voltage applied V: output voltage too low DC ON: green LED DC LOW: red LED Output circuit +, - ++, -- Rated output voltage 24 V DC Tolerance of the output voltage 1 % Adjustment range of the output voltage - Rated output power Rated output current Ir Ta m 60 C Derating of the output current Deviation with load change 24-28 V DC 10 W 30 W 60 W 100 W 0.42 A 1.3 A 2.5 A 4.2 A 60 C < Ta m 70 C 11 2.5 %/K statical max. 1 % dynamical 10-90% change of input voltage within the input voltage range max. 1 % Control time Starting time after applying the supply voltage Response time Residual ripple and switching peaks < 1 ms at Ir 1000 ms at rated load typ. 1 ms BW = 20 MHz 50 mV Parallel connection no Series connection yes, to increase voltage Resistance to reverse feed 35 V / 1 s Power factor correction (PFC) no Output circuit - No-load, overload and short-circuit behavior Output curve U/I curve Short-circuit protection continuous short circuit stability Short-circuit behavior continuation with current limitation Current limitation at short circuit typ. 0.78 A typ. 4.2 A typ. 6.05 A Overload protection current limitation No-load protection continuous no-load stability Starting of capacitive loads typ. 11.5 A unlimited General data Efficiency typ. 80 % Duty time Weight Material of enclosure Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18 x 91 x 57.5 mm [0.71 x 3.58 x 2.26 in] 53 x 91 x 57.5 mm [2.09 x 3.58 x 2.26 in] 71 x 91 x 57.5 mm [2.80 x 3.58 x 2.26 in] 89.9 x 91 x 57,5 mm [3.54 x 3.58 x 2.26 in] 0.06 kg (0.13 lb) 0.19 kg (0.41 lb) 0.25 kg (0.55 lb) 0.32 kg / (0.72 lb) DIN rail (EN 60715), snap-on mounting without any tool Mounting position Protection class typ. 89 % plastic Mounting Degree of protection typ. 75 % 100 % Dimensions (WxHxD) Minimum distance to other units typ. 83 % horizontal horizontal / vertical enclosure / terminals 25 mm / 25 mm (0.98 in / 0.98 in) IP20 / IP20 II 11.9 1SXU000023C0202 r we ies o P pl p su Technical data CP-D range Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule 0.2-2 mm2 (24-14 AWG) rigid Stripping length 6 mm (0.24 in) Tightening torque 0.36-0.56 Nm Environmental data Ambient temperature range operation -25...+70 C full load -25...+60 C storage -25...+85 C Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 C, 95 % RH Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s2, 10 Hz - 2 kHz 40 m/s2, 22 ms Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC Pollution category 2 Standards Product standard EN 61204 Low Voltage Directive 11 2006/95/EC EMC Directive 2004/108/EC Electrical safety UL 508, UL 60950-1, EN 60950-1 Protective low voltage SELV (EN 60950-1) Electromagnetic compatibility Interference immunity EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 fast transients (Burst) IEC/EN 61000-4-4 Level 4 (4 kV) powerful impulses (Surge) IEC/EN 61000-4-5 Level 4 (2 kV L-L) HF line emission IEC/EN 61000-4-6 Interference emission Level 4 (4 kV / 8 kV) Level 4 (8 kV / 15 kV) Level 3 (10 V/m) Level 3 (10 V) EN 61000-6-3 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 11.10 1SXU000023C0202 Level 4 (4 kV / 8 kV) Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical diagrams CP-D range P su owe pp r lie s Technical diagrams Output curve at Ta = 25 C Temperature curve at rated output voltage Uout [V] Uout [V] 12 11 10 9 8 7 6 5 4 3 2 1 0 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0.25 0.5 0.75 1 1.25 Iout [A] CP-D 12/0.83 Pout [%] 100 90 80 70 60 50 40 30 20 10 0.5 0 Uout [V] Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0.125 0.25 0.375 0.5 0.625 0.75 0.875 Iout [A] 0.5 0 Uout [V] Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 1 2.5 3 3.5 4 Iout [A] -10 0 10 20 30 40 50 60 70 Ta [C] CP-D 1 1.5 2 4 5 2.5 3 Iout [A] CP-D 24/1.3 24 22 20 18 16 14 12 10 8 6 4 2 0 0.5 2 11 CP-D 24/0.42 0 1.5 CP-D 12/2.1 24 22 20 18 16 14 12 10 8 6 4 2 0 0 1 1.5 2 2.5 3 CP-D 24/2.5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 3.5 4 Iout [A] 0 1 2 3 6 7 8 Iout [A] CP-D 24/4.2 11.11 1SXU000023C0202 Approximate dimensions CP-D range r we ies o P pl p su dimensions in mm 44,5 [1.75"] CP-D 12/0.83, CP-D 24/0.42 CP-D 12/2.1, CP-D 24/1.3 71,0 [2.80"] 44,5 [1.75"] 11.12 1SXU000023C0202 49,0 [1.93"] 32,1 [1.26"] 49,0 [1.93"] 32,1 [1.26"] CP-D 24/2.5 91,0 [3.58"] 67,0 [2.64"] 44,5 [1.75"] 57,5 [2.26"] 67,0 [2.64"] 57,5 [2.26"] 89,9 [3.54"] 91,0 [3.58"] 11 49,0 [1.93"] 32,1 [1.26"] 57,5 [2.26"] 49,0 [1.93"] 32,1 [1.26"] 91,0 [3.58"] 67,0 [2.64"] 44,5 [1.75"] 91,0 [3.58"] 67,0 [2.64"] 57,5 [2.26"] 53,0 [2.09"] 18,0 [0.71"] CP-D 24/4.2 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Switched mode power supplies CP-E Range "DC OK" output The CP-E range 24 V devices > 18 W offer a semiconductor output for function monitoring and remote diagnosis. Wide range input Optimized for world-wide applications: The CP-E power supplies can be supplied with 85-265 V AC or 90-375 V DC. Adjustable output voltage The CP-E range types feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. P su owe pp r lie s * Output voltages 5 V, 12 V, 24 V, 48 V DC * Adjustable output voltages * Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A * Power range 15 W, 18 W, 30 W, 60 W * Wide range input 100-240 V AC (90-265 V AC / 120-370 V DC, 85-265 V AC / 90-375 V DC) * High efficiency of up to 89 % * Low power dissipation and low heating * Free convection cooling (no forced cooling with ventilators) * Ambient temperature range during operation -10...+70 C * Open-circuit, overload and short-circuit stable * Integrated input fuse * U/I characteristic curve for devices > 18 W (fold-forward behavior at overload - no switch-off) * Redundancy unit CP-RUD offering true redundancy * LED(s) for status indication * Signalling output (transistor) for output voltage OK on 24 V devices > 18 W 11 * Approvals / Marks (depending on device, partly pending): A, H, B, D, E / a, b Redundancy unit CP-RUD 1SVR 423 418 R9000 For decoupling of parallellized power supply units. Thus, true redundancy can be achieved. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 11.13 1SXU000023C0202 r we ies o P pl p su Switched mode power supplies CP-E Rated input voltage Rated output voltage / current Order code Pack. unit pieces Weight 1 piece kg / lb CP-E 5/3.0 100-240 V AC 5 V DC / 3.0 A 1SVR 427 033 R3000 1 0.15 / 0.33 CP-E 12/2.5 100-240 V AC 12 V DC / 2.5 A 1SVR 427 032 R1000 1 0.29 / 0.64 CP-E 24/0.75 100-240 V AC 24 V DC / 0.75 A 1SVR 427 030 R0000 1 0.15 / 0.33 CP-E 24/1.25 100-240 V AC 24 V DC / 1.25 A 1SVR 427 031 R0000 1 0.29 / 0.64 CP-E 24/2.5 100-240 V AC 24 V DC / 2.5 A 1SVR 427 032 R0000 1 0.36 / 0.79 CP-E 48/0.62 100-240 V AC 48 V DC / 0.625 A 1SVR 427 030 R2000 1 0.29 / 0.64 CP-E 48/1.25 100-240 V AC 48 V DC / 1.25 A 1SVR 427 031 R2000 1 0.36 / 0.79 Type CP-E 5/3.0 CP-E 12/2.5 Redundancy module 11 The CP-RUD monitors two CP-E range power supplies with an output current of up to 5 A each. If one power supply fails, CP-RUD automatically switches to the alternate supply without interruption of the load current. Max. voltage 40 V. Type CP-RUD Description Order code Pack. unit pieces Weight 1 piece kg / lb Redundancy module 1SVR 423 418 R9000 1 0.15 / 0.33 CP-E 24/2.5 CP-E 48/0.62 CP-RUD 11.14 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-E Range P su owe pp r lie s Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-E 5/3.0 CP-E 12/2.5 CP-E 24/0.75 Input circuit CP-E 24/1.25 L, N Rated input voltage UIN 100-240 V AC Input voltage range 90-265 V AC / 120-370 V DC 85-264 V AC / 90-375 V DC at 110 V AC 310 mA / 19.65 W 580 mA / 35.18 W 336 mA / 22.6 W 568 mA / 36.38 W at 230 V AC 183.2 mA / 19.85 W 328 mA / 36.6 W 197.4 mA/ 23.0 W 326.6 mA / 37.05 W 18 A (max. 3 ms) 40 A (max. 3 ms) 18 A (max. 3 ms) 40 A (max. 3ms) min. 75 ms min. 30 ms min. 75 ms min. 30 ms Frequency range AC 90-265 V AC / 120-370 V DC 85-264 V AC / 90-375 V DC 47-63 Hz Typical input current / power consumption Inrush current Power failure buffering Internal input fuse 2 A slow-acting / 250 V AC Indication of operational states Output voltage V: output voltage OK OK: green LED LOW: red LED V: output voltage too low - V: output voltage too low 5 V DC 12 V DC Output circuit - L+,L- Rated output voltage 24 V DC Tolerance of the output voltage 1 % Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current 4.7-6 V DC 12-15 V DC 21.6-28.8 V DC 24-28 V DC 15 W 30 W 18 W 30 W Ta m 60 C 3.0 A 2.5 A 0.75 A 1.25 A 60 C < Ta m 70 C 3 %/K 2.5 %/K 3 %/K 2.5 %/K max. 2 % max. 0.5 % max. 2 % max. 0.5 % max. 1 % max. 0.5 % max. 1 % max. 0.5 % Signalling output for output voltage OK DC OK Deviation with load change statical - 11 yes dynamic 10-90 % change of input voltage within the input voltage range Control time Starting time after applying the supply voltage Response time Residual ripple and switching peaks < 2 ms max. 1 s at Ir at rated load max. 150 ms BW = 20 MHz 50 mV Parallel connection yes, to enable redundancy Series connection Resistance to reverse feed yes, to increase voltage approx. 9 V DC approx. 18 V DC Power factor correction (PFC) approx. 35 V DC no Output circuit - No-load, overload and short-circuit behavior Output curve Hiccup-mode Short-circuit protection Short-circuit behavior Overload protection Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Hiccup-mode U/I curve continuation with current limitation Hiccup-mode continuation with current limitation thermal protection with switch-off and restart current limitation thermal protection with switch-off and restart current limitation not possible unlimited Hiccup-mode No-load protection Starting of capacitive loads U/I curve continuous short circuit stability continuous no-load stability not possible unlimited 11.15 1SXU000023C0202 r we ies o P pl p su Technical data CP-E Range Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-E 5/3.0 CP-E 12/2.5 typ. 75 % typ. 84 % CP-E 24/0.75 CP-E 24/1.25 typ. 77 % typ. 86 % General data Efficiency Duty time 100 % Dimensions (W x H x D) Weight Material of enclosure 23.9 x 88.5 x 115 mm [0.94 x 3.48 x 4.53 in] 43.5 x 88.5 x 115 mm [1.71 x 3.48 x 4.53 in] 0.15 kg (0.33 lb) 0.29 kg (0.64 lb) 0.15 kg (0.33 lb) 0.29 kg (0.64 lb) DIN rail (EN 60715), snap-on mounting without any tool Mounting position Degree of protection 43.5 x 88.5 x 115 mm [1.71 x 3.48 x 4.53 in] plastic Mounting Minimum distance to other units 23.9 x 88.5 x 115 mm [0.94 x 3.48 x 4.53 in] horizontal horizontal / vertical enclosure / terminals Protection class 25 mm / 25 mm (0.98 in / 0.98 in) IP20 / IP20 I Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule 0.2-2 mm2 (24-14 AWG) rigid Stripping length 11 6 mm (0.24 in) Tightening torque 0.5-0.6 Nm Environmental data Ambient temperature range operation -10...+70 C full load -10...+60 C storage Damp heat (cyclic) (IEC/EN 60068-2-30) -25...+85 C 4 x 24 cycle, 40 C, 95 % RH 10 m/s2, 10...500 Hz Vibration (sinusoidal) (IEC/EN 60068-2-6) 40 m/s2, 22 ms, all directions Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui input circuit / output circuit Pollution category 3 kV AC 2 Standards Product standard EN 61204 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC Electrical safety EN 50178, EN 60950-1, UL 60950-1, UL 508 Protective low voltage SELV (EN 60950) Electromagnetic compatibility Interference immunity IEC/EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 4 (8 kV / 15 kV) electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000-4-4 Level 4 (4 kV) powerful impulses (Surge) IEC/EN 61000-4-5 Level 4 (2 kV / 4 kV) HF line emission IEC/EN 61000-4-6 Interference emission Level 3 (10 V) IEC/EN 61000-6-3 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 11.16 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-E Range P su owe pp r lie s Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-E 24/2.5 Input circuit CP-E 48/0.62 CP-E 48/1.25 L, N Rated input voltage UIN 100-240 V AC Input voltage range 85-264 V AC / 90-375 V DC Frequency range AC 47-63 Hz Typical input current / power consumption at 110 V AC 1080 mA / 69.4 W 566 mA / 35.34 W 1080 mA / 69.2 W at 230 V AC 570 mA / 69.0 W 320 mA / 36 W 573 mA / 68.8 W 60 A (max. 3 ms) 40 A (max. 3 ms) 60 A (max. 3 ms) Inrush current Power failure buffering min. 30 ms Internal input fuse 2 A slow-acting / 250 V AC Indication of operational states Output voltage V: output voltage OK OK: green LED LOW: LED rot - Output circuit L+,L- Rated output voltage 24 V DC Tolerance of the output voltage 24-28 V DC Rated output power Ta m 60 C Derating of the output current 48 V DC 1 % Adjustment range of the output voltage Rated output current Ir 48 V DC 30 W 60 W 2.5 A 0.625 A 1.25 A 60 C < Ta m 70 C Signalling output for output voltage OK DC OK Deviation with load change statical 48-55 V DC 60 W 11 2.5 %/K yes max. 0.5 % dynamic 10-90 % change of input voltage within the input voltage range Control time Starting time after applying the supply voltage Response time Residual ripple and switching peaks max. 1 % max. 0.5 % at Ir at rated load BW = 20 MHz max. 1 s max. 150 ms 50 mV Parallel connection yes, to enable redundancy Series connection yes, to increase voltage Resistance to reverse feed Power factor correction (PFC) max. 1 % < 2 ms approx. 35 V DC no Output circuit - No-load, overload and short-circuit behaviour Output curve U/I curve Short-circuit protection continuous short circuit proof Short-circuit behaviour continuation with current limitation Overload protection current limitation No-load protection continuous no-load stability Starting of capacitive loads Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage unlimited 11.17 1SXU000023C0202 r we ies o P pl p su Technical data CP-E Range Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-E 24/2.5 CP-E 48/0.62 CP-E 48/1.25 typ. 89 % typ. 86 % typ. 89 % General data Efficiency Duty time 100 % Dimensions (W x H x D) 43.5 x 88.5 x 115 mm (1.71 x 3.48 x 4.53 in) Weight 0.36 kg (0.79 lb) Material of enclosure DIN rail (EN 60715), snap-on mounting without any tool Mounting position Degree of protection 0.36 kg (0.79 lb) plastic Mounting Minimum distance to other units 0.29 kg (0.64 lb) horizontal horizontal / vertical enclosure / terminals Protection class 25 mm / 25 mm (0.98 in / 0.98 in) IP20 / IP20 I Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule 0.2-2 mm2 (24-14 AWG) rigid Stripping length 6 mm (0.24 in) Tightening torque 0.5-0.6 Nm Environmental data 11 Ambient temperature range operation -10...+70 C full load -10...+60 C storage Damp heat (cyclic) (IEC/EN 60068-2-30) -25...+85 C 4 x 24 cycle, 40 C, 95 % RH 10 m/s2, 10...500 Hz Vibration (sinusoidal) (IEC/EN 60068-2-6) 40 m/s2, 22 ms, all directions Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui input circuit / output circuit Pollution category 3 kV AC 2 Standards Product standard EN 61204 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC Electrical safety EN 50178, EN 60950-1, UL 60950-1, UL 508 Protective low voltage SELV (EN 60950) Electromagnetic compatibility Interference immunity IEC/EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 fast transients (Burst) IEC/EN 61000-4-4 Level 4 (4 kV) powerful impulses (Surge) IEC/EN 61000-4-5 Level 4 (2 kV / 4 kV) HF line emission IEC/EN 61000-4-6 Interference emission IEC/CISPR 22, EN 55022 HF line emission IEC/CISPR 22, EN 55022 1SXU000023C0202 Level 3 (10 V/m) Level 3 (10 V) IEC/EN 61000-6-3 electromagnetic field (HF radiation resistance) 11.18 Level 4 (8 kV / 15 kV) Class B Class B Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-E Range P su owe pp r lie s Data at Ta = 25 C, if nothing else indicated Type CP-RUD Input circuit - Supply circuit A: U1+/-U ; B: U2+/-U 24 V DC Rated input voltage UIN Input voltage range 5-35 V DC Rated input current IIN per channel 0.5-2.5 A Maximum input current per channel 10 A for 300 s Transient overvoltage protection no Output circuit L+, L+, L+, L-, L- , L24 V DC Rated output voltage UOUT Voltage drop typ. 0.6 V, max. 0.7 V 0.5-5 A Rated output current IOUT Peak output current 20 A for 150 s Resistance to reverse feed < 35 V General data Dimensions (W x H x D) 22.5 mm x 78 mm x 102 mm (0.89 x 3.07 x 4.02 in) Weight 0.135 kg (0.30 lb) Minimum distance to other units horizontal / vertical Degree of protection enclosure / terminals Material of enclosure enclosure shell / cover Protection class 10 mm / 10 mm (0.39 in / 0.39 in) IP20 / IP20 plastic / plastic - Mounting DIN rail Mounting position horizontal 11 Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length 2 x 0.75-2.5 mm2 (2 x 18-14 AWG) 2 x 0.5-4 mm2 (2 x 20-12 AWG) 7 mm (0.28 in) Tightening torque 0.6-0.8 Nm Environmental data Ambient temperature range operation -20...+60 C full load -20...+60 C storage Damp heat (IEC/EN 60068-2-3) -40...+85 C 93 % at 40 C, no condensation Climatic category (IEC/EN 60721) - Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Insulation voltage between input / output / enclosure Pollution degree (EN 50178) 2 Standards Product standard Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Electrical safety EN 50178 Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3 (air discharge w8 kV, contact discharge w6 kV) electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000-4-4 Level 3 (w2 kV) powerful impulses (Surge) IEC/EN 61000-4-5 Level 1 (w0.5 kV) HF line emission IEC/EN 61000-4-6 Interference emission Level 3 (10 V) IEC/EN 61000-6-3 electromagnetic field (HF radiation resistance) IEC/CISPR 22 / EN 55022 Class B HF line emission IEC/CISPR 22 / EN 55022 Class B Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 11.19 1SXU000023C0202 Technical diagrams, circuit diagrams CP-E Range r we ies o P pl p su Technical diagrams Output curve at Ta = 25 C Uout [V] Uout [V] Uout [V] 15 13 11 9 7 5 3 1 2.8 2.9 CP-E 12/2.5 11 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Iout [A] 1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15 Iout [A] CP-E 24/1.25 Uout [V] Uout [V] 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0.665 0.705 0.745 0.785 0.825 0.865 0.905 0.945 0.985 1.025 Iout [A] CP-E 48/0.62 2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Iout [A] CP-E 24/2.5 1.33 1.41 1.49 1.57 1.65 1.73 1.81 1.89 1.97 2.05 Iout [A] CP-E 48/1.25 Temperature curve at rated output voltage Pout [%] 100 90 80 70 60 50 40 30 20 10 -10 0 10 20 30 40 50 CP-E 60 70 Ta [C] Wiring instructions Relay 5 V Signal RL > 700 q DC OK DC OK L- L- 2.2 kq 0.5 W 5.1 V 0.3 W CP-E 24/1.25, CP-E 24/2.5 11.20 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions CP-E Range CP-E 5/3.0, CP-E 24/0.75 CP-E 12/2.5, CP-E 24/1.25, CP-E 24/2.5, CP-E 48/0.62, CP-E 48/1.25 115 [4.53"] 43,5 [1.71"] 115 [4.53"] 88,5 [3.48"] 88,5 [3.49"] 23,9 [0.94"] P su owe pp r lie s CP-RUD 109,5 102 22,5 [4.31"] [.886"] [4.02"] 78 [3.07"] 11 100 [3.94"] Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 11.21 1SXU000023C0202 r we ies o P pl p su Notes 11 11.22 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Switched mode power supplies CP-S, CP-C & CP-A Range P su owe pp r lie s CP-S and CP-C range * Output current 5 A, 10 A and 20 A * Integrated power reserve of up to 50 % * 5 A and 10 A devices with pluggable connecting terminals * Approvals / marks (depending on device, partly pending) A, H, D, K, E / a, b CP-S range * 10 A and 20 A devices with front-face selector switch to adjust rated input voltage range: 110-120 V AC or 220-240 V AC * Output voltage fixed at 24 V DC * Parallel operation for redundancy CP-C range * Wide range input 110-240 V AC (85-264 V AC, 100-350 V DC) * Output voltage adjustable in a range of 22-28 V DC * Parallel operation for increased capacity and redundancy * Power factor correction (PFC) acc. to EN 61000-3-2 * Function module pluggable onto the front side Messaging module CP-C MM: * LED for status indication * Relay outputs "Input OK" and "Output OK" * REMOTE ON/OFF function to switch on and off the power supply externally * Output voltage monitoring is only possible in decoupled parallel operation Integrated power reserve The new CP-S and CP-C range power supplies feature an integrated power reserve of up to 50 %. No oversized electricity supply is needed, especially under heavy load conditions. 11 Pluggable connecting terminals Extended flexibility in operation due to pluggable connecting terminals (this feature is not offered on all devices). Adjustable output voltage CP-A range Redundancy unit CP-A RU * Redundancy unit with 2 inputs / channels for decoupling of 2 CP-S or 2 CP-C power supplies * Up to 20 A per input / channel and output up to 40 A * True redundancy by 100 % decoupling with 2 integrated diodes The CP-C range types feature a continuously adjustable output voltage from 22 to 28 V. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by long line length. Control module CP-A CM * Pluggable onto redundancy unit CP-A RU * One relay output per monitored input / channel * Threshold values adjustable (14-28 V) * Indicates the presence of both input voltages (of the CP-A RU) via LEDs and energized output relays Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Pluggable function modules CP-A RU + CP-A CM The CP-C range power supplies can be equipped with pluggable modules to add additional functions (e.g. messaging module). Thus, the power supplies can be ideally adapted to the relevant application. 11.23 1SXU000023C0202 r we ies o P pl p su Switched mode power supplies CP-S, CP-C & CP-A Rated input voltage Rated output voltage / current Order code Pack. unit pieces Weight 1 piece kg / lb CP-S 24/5.0 110-240 V AC 24 V DC / 5A 1SVR 427 014 R0000 1 0.96 / 2.11 CP-S 24/10.0 110-120 V AC/ 220-240 V AC 24 V DC / 10 A 1SVR 427 015 R0100 1 1.07 / 2.35 CP-S 24/20.0 110-120 V AC/ 220-240 V AC 24 V DC / 20 A 1SVR 427 016 R0100 1 2.83 / 6.23 CP-C 24/5.0 110-240 V AC 24 V DC / 5A 1SVR 427 024 R0000 1 0.96 / 2.11 CP-C 24/10.0 110-240 V AC 24 V DC / 10 A 1SVR 427 025 R0000 1 1.34 / 2.95 CP-C 24/20.0 110-240 V AC 24 V DC / 20 A 1SVR 427 026 R0000 1 3.15 / 6.94 Order code Pack. unit pieces Weight 1 piece kg / lb 1SVR 427 081 R0000 1 1SVR 427 071 R0000 1 0.89 / 1.96 1 0.063 / 0.14 Type CP-S range CP-S 24/5.0 CP-C range 11 CP-C 24/10.0 Type Description Accessories for CP-C range CP-C MM Messaging module CP-S 24/20.0 0.065 / 0.14 Accessories for CP-S and C range CP-A RU CP-A CM Redundancy unit Control module 1SVR 427 075 R0000 CP-A RU CP-A CM 11.24 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-S, CP-C & CP-A Range P su owe pp r lie s Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type Input circuit - supply circuit Rated input voltage UIN Input voltage range CP-C 24/5.0 CP-S 24/5.0 L, N CP-C CP-S CP-C CP-S switch position 115 switch position 230 switch position 115 switch position 230 Frequency range AC Current consumption Power consumption Inrush current / I2t ( cold start) Power failure buffering at rated load at 110-240 V AC at 110-120 V AC at 220-240 V AC CP-C CP-S CP-C CP-S Transient overvoltage protection Internal input fuse (apparatus protection, not accessible) Indication of operational states Output voltage OUTPUT OK: green LED Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Peack output current (power reserve) Derating Deviation with Control time Starting time after applying supply voltage Response time 10-90 % CP-C CP-S CP-C CP-S Ta < 60 C Ta < 40 C 60 C < Ta < 70 C CP-C load change statical CP-S load change statical load change dynamical 10-90 % change of the input voltage of 10 % CP-C CP-S CP-C CP-S Residual ripple and switching peaks Parallel connection 20 MHz Series connection Resistance to reverse feed Power factor correction (PFC) CP-C CP-S Output circuit - No-load, overload and short-circuit behaviour Output curve Current limitation at short circuit Short-circuit protection Overload protection Starting of capacitive loads General data Power dissipation Efficiency Discharge current for PE MTBF Dimensions (W x H x D) Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage CP-C 24/10.0 CP-S 24/10.0 CP-C 24/20.0 CP-S 24/20.0 110-240 V AC 110-120 V AC 110-240 V AC 220-240 V AC 85-264 V AC / 100-350 V DC 1) 85-132 V AC 85-264 V AC / 100-350 V DC 1) 184-264 V AC / 220-350 V DC 1) 47-63 Hz approx. 2.2-1.2 A approx. 3.5-1.6 A approx. 5.5-2.5 A approx. 4.2-4.0 A approx. 9.0-8.0 A approx. 2.4-2.2 A approx. 4.5-4.0 A typ. 135 W typ. 269 W typ. 538 W < 40 A / approx. 1.9 A2s < 33 A / approx. 0.2 A2s < 23 A / approx. 0.9 A2s < 40 A / approx. 1.8 A2s < 70 A / approx. 8 A2s > 40 ms typ. > 40 ms > 100 ms > 50 ms typ. > 50 ms varistors 4 A (slow-acting) 6.3 A (slow-acting) 12 A (fast-acting) V: output voltage OK L+, L+, L-, L- : short-circuit, no-load and overload proof 24 V DC w1 % -1...+5 % 22-28 V DC, default setting 24 V 0.5 % fixed 120 W 240 W 480 W 5A 10 A 20 A typ. 7.25 A typ. 12.25 A typ. 22.5 A 2.5 % per Kelvin temperature increase typ. < 0.05 % typ. < 0.1 % typ. < 3 % typ. < 0,05 % typ. < 1 ms < 5 ms typ. < 370 ms < 100 ms < 10 ms typ. < 20 ms typ. < 4 ms typ. < 12 ms typ. < 30 ms typ. < 5 ms typ. < 15 ms typ. < 50 mVPP yes, up to 5 devices, to enable redundancy and to increase capacity, current not symmetrical (CP-S only redundancy) yes, to increase voltage approx. 35 V DC yes no see also U/I and I/T curves U/I curve with power reserve approx. 11 A approx. 19 A approx. 25 A continuous short-circuit stability thermal protection unlimited typ. < 15 W CP-C CP-S 56.5 (60 2)) x 130 x 137 mm [2.22 (2.36 2)) x 5.12 x 5.39 in] typ. < 29 W typ. 88-89 % < 3.5 mA 500.000 h 350.000 h 90 (93.5 2)) x 130x 137 mm [3.54 (3.68 2)) x 5.12 x 5.39 in] 11 typ. < 58 W 200 (203.5 2)) x 130 x 137 mm [7.87 (8.01 2)) x 5.12 x 5.39 in] 11.25 1SXU000023C0202 r we ies o P pl p su Technical data CP-S, CP-C & CP-A Range Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type Weight CP-C 24/5.0 CP-S 24/5.0 CP-C CP-S Minimum distance to other units Degree of protection Material of enclosure Protection class (EN 61140) Mounting Mounting position Electrical connection - Input circuit Wire size horizontal / vertical enclosure / terminals enclosure shell / cover CP-C 24/10.0 CP-C 24/20.0 CP-S 24/10.0 CP-S 24/20.0 approx. 1.34 kg (2.95 lb) approx. 3.15 kg (6.94 lb) approx. 0.96 kg (2.12 lb) approx. 1.07 kg (2.36 lb) approx. 2.83 kg (6.23 lb) 10 mm / 80 mm (0.39 in / 3.15 in) IP20 / IP20 aluminium / zinc-coated sheet steel I DIN rail (EN 50022), snap-on mounting horizontal 3) fine-strand with wire end ferrule fine-strand without wire end ferrule rigid 3) fine-strand with wire end ferrule fine-strand without wire end ferrule rigid 2.5-10 mm2 (14-8 AWG) 0.5-10 mm2 (20-8 AWG) 0.5-16 mm2 (20-6 AWG) 12 mm (0,47 in) 1.2-1.5 Nm 0.12-2.5 mm2 (26-14 AWG) 8 mm (0.31 in) 0.4 Nm Environmental data Ambient temperature range operation full load storage Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Rated impulse withstand voltage Uimp (type test) input / output input / PE input / output input / PE output / PE Power-frequency withstand voltage test (routine test) Pollution degree (EN 50178) Standards Product standard Low Voltage Directive EMC Directive Electrical safety Protective low voltage Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission electromagnetic field (HF radiation resistance) HF line emission 3) 7 mm (0.28 in) 0.4 Nm Stripping length Tightening torque 11 2.5-10 mm2 (14-8 AWG) 0.5-10 mm2 (20-8 AWG) 0.5-16 mm2 (20-6 AWG) 12 mm (0.47 in) 1.2-1.5 Nm 0.2-2.5 mm2 (24-14 AWG) Stripping length Tightening torque Electrical connection - Output circuit Wire size 3) -25...+70 C 0...+60 C (without derating) -40...+85 C 93 % at +40 C, no condensation 3K3 3 kV AC 1.5 kV AC 1.2 kV AC 1.2 kV AC 350 V AC 2 IEC/EN 61204 2006/95/EC 2004/108/EC EN 50178, EN 60950, UL 60950, UL 508 SELV (EN 60950) IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-6-2 Level 4 (8 kV / 15 kV) Level 3 (10 V/m) IEC/CISPR 22, EN 55022 Level 4 (4 kV) Level 4 (2 kV symmetrical, level 3 - 3 kV asymmetrical) Level 3 (10 V) IEC/EN 61000-6-3 Class B IEC/CISPR 22, EN 55022 Class B 1) at U > 264 V use additionally an appropriate external fuse with lateral screw 3) pluggable connecting terminals, actuate only when power is off 2) 11.26 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-S, CP-C & CP-A Range P su owe pp r lie s Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type Input circuit - Supply circuit Rated input voltage UIN Input voltage range Power consumption Input circuit - Control circuit Kind of triggering Control input, control function Remote OFF Threshold "Switching-off power supply unit" Threshold "Switching-on power supply unit" Input current Maximum cable length to the control input Measuring circuit - INPUT Monitoring function Thresholds Hysteresis, related to the threshold value Accuracy, tolerance Maximum measuring cycle Measuring circuit - OUTPUT Monitoring function Thresholds Hysteresis, related to the threshold value Accuracy, tolerance Maximum measuring cycle Indication of operational states Remote off REMOTE OFF: green LED Status of power supply input Status of power supply output Input OK: green LED OUTPUT OK: green LED Output circuits Kind of output Operating principle Contact material Rated voltage (VDE 0110, IEC/EN 60947-1) Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current Rated operating AC12 (resistive) 230 V current Ie AC15 (inductive) 230 V (IEC/EN 60947-1) DC12 (resistive) 24 V DC13 (inductive) 24 V Mechanical lifetime Electrical lifetime Short circuit proof, n/c contact maximum fuse rating n/o contact General data Duty time Dimensions (W x H x D, when mounted) Weight Degree of protection enclosure / terminals Material of enclosure Protection class (EN 61140) Mounting Mounting position Electrical connection Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length Tightening torque Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage CP-C MM powered by the input circuit of the power supply 70-264 V AC / 80-350 V DC 2.5 VA / 1.5 W volt-free triggering remote off R 1 k R 10 k typ. 1 mA (200 mA for 200 s) 25 m undervoltage monitoring of input voltage of the power supply unit 85 V AC / 90 V DC AC: typ. -8 % / DC -30 % -5 % at AC and DC typ. < 50 ms undervoltage monitoring of output voltage of the power supply unit 20 V DC typ. 5 % 1 % typ. < 10 ms 11 V: REMOTE OFF" input R 1k V: relay INPUT OK" energized V: relay OUTPUT OK" energized 11-12/14, 21-22/24 relays, 2 x 1 c/o contacts closed-circuit principle AgNi 250 V 24 V / 10 mA 250 V / 1 A 1A 1A 1A 1A 30 x 106 switching cycles 0.1 x 106 switching cycles 2 A, gL 2 A, gL 100 % 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in) 0.065 kg (0.14 lb) IP20 / IP20 UL94V0 II snap-on mounting, without any tool plugged onto the power supply unit 0.2-2.5 mm2 (24-14 AWG) 0.2-4 mm2 (24-12 AWG) 7.5 mm (0.3 inch) 0.4-0.6 Nm 11.27 1SXU000023C0202 r we ies o P pl p su Technical data CP-S, CP-C & CP-A Range Data at Ta = 25 C, UIN = 230 V AC and rated values, if nothing else indicated Type CP-C MM Environmental data Ambient temperature range operation storage Damp heat (IEC/EN 60068-2-3) -25...+70 C -40...+85 C 93 % at +40 C, no condensation Climatic category (IEC/EN 60721) 3K3 Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui (IEC/EN 60974-1, EN 50178, VDE 0160) 250 V Protective separation (EN 50178, EN 60950) supply / measuring circuits / relay outputs yes Rated impulse withstand voltage Uimp between all isolated circuits (IEC 664, VDE 0110) Test voltage between all circuits (type test) 4 kV; 1.2/50 s 2.5 kV AC Pollution degree (EN 60950) 2 Overvoltage category (EN 60950) II Standards Product standard 11 IEC/EN 61204 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Electrical safety EN 50178, EN 60950, UL 60950, UL 508 Elektromagnetic compatibility Inferference immunity electrostatic discharge (ESD) IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3 and 4 (6 kV / 8 kV) electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000-4-4 Level 4 and 2 (4 kV power input / 1 kV control input) powerful impulses (Surge) IEC/EN 61000-4-5 Level 3 and 2 (4 kV symmetrical power input / 1 kV control input) HF line emission IEC/EN 61000-4-6 Interference emission Level (10 V) IEC/EN 61000-6-3 HF line emission IEC/CISPR 22 / EN 55022 Class B electromagnetic field (HF radiation resistance) IEC/CISPR 22 / EN 55022 Class B 11.28 1SXU000023C0202 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Technical data CP-S, CP-C & CP-A Range P su owe pp r lie s Data at Ta = 25 C, if nothing else indicated Type Input circuit - Supply circuit Rated input voltage UIN Input voltage range Rated input current IIN per channel Maximum input current per channel Transient overvoltage protection Output circuit Rated output voltage Voltage drop Rated output current Peak output current Resistance to reverse feed General data Dimensions (W x H x D) CP-A RU (+/ -, +/ -) 24 V DC 10-40 V DC 1-20 A 30 A for 300 s yes (++/--) 24 V DC typ. 0.6 V, max. 0.9 V 1-40 A 60 A for 300 s < 40 V Weight Minimum distance to other units horizontal / vertical Degree of protection enclosure / terminals Material of enclosure enclosure shell / cover Protection class Mounting Mounting position Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length Tightening torque Environmental data Ambient temperature range operation full load storage Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Insulation voltage between input / output / enclosure Pollution degree (EN 50178) Standards Product standard Low Voltage Directive EMC Directive Electrical safety Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 fast transients (Burst) IEC/EN 61000-4-4 powerful impulses (Surge) IEC/EN 61000-4-5 HF line emission IEC/EN 61000-4-6 Interference emission IEC/CISPR 22 / EN electromagnetic field (HF radiation re55022 sistance) HF line emission 1) 2) IEC/CISPR 22 / EN 55022 56.5 (60 1)) x 130 x 137 mm (2.22 (2.36 1)) x 5.12 x 5.39 in) 0.89 kg (1.96 lb) 10 mm / 50 mm (0.39 in / 1.97 in) IP20 / IP20 aluminium / zinc-coated sheet steel III 2) DIN rail horizontal 11 2.5-10 mm2 (14-8 AWG) 0.5-10 mm2 (20-8 AWG) 0.5-16 mm2 (20-6 AWG) 12 mm (0.47 in) 1.2-1.5 Nm -25...+70 C -25...+60 C (without derating) -40...+85 C 93 % at 40 C, no condensation 3K3 500 V AC (routine test) 2 IEC/EN 61204 2006/95/EC 2004/108/EC EN 50178, EN 60950, UL 60950, UL 508 IEC/EN 61000-6-2 Level 3 (air discharge w8 kV, contact discharge w6 kV) Level 3 (10 V/m) Level 3 (w2 kV) Level 1 (w0.5 kV) Level 3 (10 V) IEC/EN 61000-6-3 Class B Class B includes lateral screw This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding of the enclosure (protection class I). Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 11.29 1SXU000023C0202 r we ies o P pl p su Technical data CP-S, CP-C & CP-A Range Data at Ta = 25 C, if noting else indicated 11 Type Input circuit - Supply circuit Rated input voltage UIN Input voltage range Power consumption Measuring circuit Monitoring function Measuring voltage Thresholds Hysteresis, related to the threshold value Accuracy, tolerance Maximum measuring cycle Indication of operational states Status of input 1 CP-A CM IN 1: green LED : voltage at input 1 > than threshold 1 = no faults present Status of input 2 IN 2: green LED : voltage at input 2 > than threshold 2 = no faults present Output status OUT: green LED at 24 V DC Output circuit Kind of output Contact material Operating principle Rated operational voltage Ue (IEC/EN 60947-1, VDE 0110) Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current Rated operational current Ie AC12 (resistive) (IEC/EN 60947-5-1) AC15 (inductive) DC12 (resistive) DC13 (inductive) Mechanical lifetime Electrical lifetime Short-circuit proof, maximum fuse rating General data Duty time Dimensions (W x H x D, when mounted) Weight Degree of protection Material of enclosure Protection class Mounting Mounting position Electrical conection Wire size 230 V 230 V 24 V 24 V n/c contact n/o contact enclosure / terminals fine-strand with wire end ferrule fine-strand without wire end ferrule rigid Stripping length Tightening torque Isolation data Rated insulation voltage Ui (IEC/EN 60947-1, EN 50178, VDE 0160) Rated impulse withstand voltage Uimp (type test) between all circuits (IEC 664, VDE 0110) Power-frequency withstand voltage test (routine test) between all circuits Protective separation (EN 50178) between input and output Pollution degree Overvoltage category Environmental data Ambient temperature range operation storage Damp heat (IEC/EN 60068-2-3) Climatic category (IEC/EN 60721) Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) 11.30 1SXU000023C0202 24 V DC 13-30 V DC approx. 1 W 11-12/14, 21-22/24 undervoltage monitoring rated operational voltage 14-28 V 3-5 % fixed 10 % of full-scale value 6 ms : UOUT > 3 V = no faults present +, +, relays, 2 x 1 c/o contact AgNi closed-circuit principle 250 V 24 V / 10 mA 250 V / 1 A 1A 1A 1A 1A 30 x 106 switching cycles 0.1 x 106 switching cycles 2 A, gL 2 A, gL 100 % 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 in) 0.063 kg (0.14 lb) IP20 / IP20 UL94V0 II snap-on mounting, without any tool plugged onto the redundancy unit CP-A RU 0.2-2.5 mm2 (24-14 AWG) 0.2-4 mm2 (24-12 AWG) 7.5 mm (0.3 in) 0.4-0.6 Nm 250 V 2.5 kV 1.2 kV AC yes 2 II -25...+70 C -40...+85 C 93 %at 40 C, no condensation 3K3 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage P su owe pp r lie s Technical diagrams CP-S, CP-C & CP-A Range Technical diagrams Output curve at 25 C Output curve at 25 C Uout [V] Temperature curve at Uout = 24 V DC Iout [A] Uout [V] Iout [A] Iout [A] CP-S 24/5.0 CP-C 24/5.0 Uout [V] Ta [C] CP-S 24/5.0, CP-C 24/5.0 Iout [A] Uout [V] 11 Iout [A] Iout [A] CP-C 24/10.0 CP-S 24/10.0 Uout [V] Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage CP-S 24/10.0, CP-C 24/10.0 Iout [A] Uout [V] Iout [A] CP-S 24/20.0 Ta [C] Iout [A] CP-C 24/20.0 Ta [C] CP-S 24/20.0, CP-C 24/20.0 11.31 1SXU000023C0202 Approximate dimensions CP-S, CP-C & CP-A Range r we ies o P pl p su Dimensional drawings dimensions in mm 60,0 [2.36"] 93,5 [3.68"] 203,5 [8.01"] 56,5 [2.22"] 90,0 [3.54"] 200,0 [7.87"] ABB 135,5 [5.33"] 130,0 [5.12"] 130,0 [5.12"] ABB CP-S 24/10.0 CP-C 24/10.0 CP-S 24/20.0 CP-C 24/20.0 54 [2.13"] CP-S 24/5.0 CP-C 24/5.0 CP-A RU ABB 130,0 [5.12"] 144,5 [5.69"] 137,0 [5.39"] 11 56,5 [2.22"] 11.32 1SXU000023C0202 24 ] 4" .9 [0 CP-C MM CP-A CM Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage