PFC375 AC-DC Series Data Sheet Features * RoHS lead-solder-exempt compliant * Greater than 1 million hours demonstrated MTBF * Power Factor Correction (PFC) meets EN61000-3-2 * Fully-regulated outputs * Main output remote sense * Current Share, Power Fail, and Power Good signals * Overtemperature, overvoltage, and overcurrent protected * Available with metric and SAE mountings * Input transient & ESD compliance to EN61000-4-2/-3/-4/-5 * Fan output voltage and optional fan Description The PFC375 products of the PerFormanCe Power Series incorporate high performance midrange power, active Power Factor Correction (PFC), and high reliability to meet varied commercial and industrial requirements. Providing tightly-regulated DC power in a wide variety of single and multiple output configurations, the PFC375 is designed to provide full output power with only 300 Linear Feet per Minute (LFM) forced-air cooling (factory installed fan optional). Other features include remote sense, power fail, logic level inhibit, and DC power good. Main channel current sharing is provided for redundant applications. The PFC375 is available with SAE mountings or optional metric mountings. The PFC375 product line is approved to the latest international regulatory standards and displays the CE Mark. Single-Output Model Selection MODEL PFC375-1012 PFC375-1015 PFC375-1024 PFC375-1028 PFC375-1048 OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY 12V 15V 24V 28V 48V 10.8V to 13.5V 12.0V to 17.0V 21.6V to 26.4V 25.2V to 30.8V 46.0V to 56.0V 30A 25A 15A 13.4A 7.8A 0.2% 0.2% 0.5% 0.5% 0.5% 0.8% 0.6% 0.8% 0.9% 1.0% 1% 1% 1% 0.9% 1% 11.94V to 12.06V 14.94V to 15.06V 23.88V to 24.12V 27.86V to 28.14V 47.52V to 48.48V NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10156 Rev. 1.0, 20-Apr-10 Page 1 of 5 www.power-one.com PFC375 AC-DC Series Data Sheet Multiple-Output Model Selection MODEL PFC375-4000 PFC375-4001 (Note 4) PFC375-4002 (Note 5) PFC375-4004 PFC375-4005 (Note 6) PFC375-4200 PFC375-4201 PFC375-4500 NOTES: 1) 2) 3) 4) 5) 6) Isolated V3 and V4 Can Be Used as Positive Or Negative Output OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY +5V +12V 12V 5V +5V +12V 12V 12V +5V +12V 12V 24V +5V +12V 15V 15V +5V +12V 24V 24V +24V +5V 12V 12V +24V +5V 15V 15V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V Fixed 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 11.0V to 15.8V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 22.0V to 28.0V 4.5V to 5.5V 11.3V to 12.6V 14.2V to 15.8V 14.2V to 15.8V 4.5V to 5.5V 11.3V to 12.6V 22.0V to 28.0V 22.0V to 28.0V 21.5V to 26.4V 4.5V to 5.5V 11.4V to 12.6V 11.4V to 12.6V 21.5V to 26.4V 4.5V to 5.5V 14.2V to 16.0V 13.7V to 16.0V 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 4A 4A 3.5 - 40A 10A 3A 3A 1 - 10A 10A 4A 4A 1 - 10A 10A 4A 4A 40A 16A 6A 3A 40A 16A 6A 3A 40A 16A 6A 3A 40A 16A 4A 4A 40A 16A 3A 3A 10A 16A 4A 4A 10A 16A 4A 4A 0.4% 0.9% 0.9% 2% 0.4% 0.9% 0.9% 0.9% 0.4% 0.9% 0.9% 0.5% 0.4% 0.9% 0.7% 0.7% 0.4% 0.9% 0.5% 0.5% 0.5% 0.4% 0.5% 0.5% 0.5% 0.4% 0.5% 0.5% 0.8% 0.9% 0.9% 2% 0.8% 0.9% 0.9% 0.9% 0.8% 0.9% 0.9% 0.8% 0.8% 0.9% 0.7% 0.7% 0.8% 0.9% 0.8% 0.8% 0.8% 0.8% 1% 1% 0.8% 0.8% 0.8% 0.8% 1% 1% 1% 2.4% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.9V to 5.1V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 11.9V to 12.1V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 14.9V to 15.1V 14.9V to 15.1V 4.98V to 5.02V 11.9V to 12.1V 23.8V to 24.2V 23.8V to 24.2V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 14.9V to 15.1V 14.9V to 15.1V +5V +12V 12V 5V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 4.5V to 5.5V 3.5 - 50A 10A 6A 3A 50A 16A 6A 3A 0.4% 0.9% 0.9% 2% 0.8% 0.9% 0.9% 0.9% 1% 1% 1% 1% 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.9V to 5.1V Output currents ratings are expressed with 300 LFM forced air. Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts. V4 can be adjusted to 16V with a minimum load of 5A on V1. For operation of V4 greater than 24V, consult factory. V3 and V4 may be series connected to obtain 48V. Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10156 Rev. 1.0, 20-Apr-10 Page 2 of 5 www.power-one.com PFC375 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Brown Out Protection Hold-Up Time Input Current Input Protection Inrush Surge Current Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse, F10A, 250V. Internally limited by thermistor, one cycle, 25C. 110 VAC 220 VAC Per EN61000-3-2. Switching frequency of main transformer. 85 47 85 20 Power Factor Operating Frequency NOM MAX UNITS 264 63 VAC Hz VAC ms ARMS 6 35 65 0.98 APK W/VA kHz 100 Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Efficiency Minimum Loads Full rated load, 110 VAC. Varies with distribution of loads among outputs. Single output models. Multiple output models, 5V main output only. Multiple output models, 24V main output only. Full load, 20MHz bandwidth. 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. Peak power, all models. Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. (Main output only on multi-output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 68 0 3.5 1 See Model Selection Charts Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-On Delay Turn-On Rise Time MCD10156 Rev. 1.0, 20-Apr-10 Page 3 of 5 NOM MAX 375 450 0 UNITS % Amps Watts V See Model Selection Charts 1 ms 1 10 Sec ms www.power-one.com PFC375 AC-DC Series Data Sheet Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Provided on single output units and the main output only of multiple output units. PFC375-30XX, PFC375-40XX, PFC375-45XX 6.0 6.4 PFC375-1012 13.5 15.5 PFC375-1015 17.0 19.5 PFC375-1024 27.0 30.7 PFC375-1028 30.8 35.0 PFC375-1048 60.0 70.0 PFC375-42XX 27.0 30.7 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. Total voltage compensation for cable losses with respect to the main output. 250 Accuracy of shared current with up to 6 parallel units. 10 TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. TTL compatible logic signal. Time before regulation dropout due to 5 loss of input power at 110 VAC. TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal. Provides 170 mA current to user-supplied fan, if fan option is not selected. 12 Overload Protection Overtemperature Protection Remote Sense Current Share Inhibit Input Power Fail Warning Power Good Fan Voltage MIN NOM MAX UNITS V mV % ms V Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection UL1950. CSA 22.2 NO. 234/950. EN60950 (TUV). Input to output. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5 class 3. Insulation Resistance Leakage Current Input to output. Per EN60950, 264 VAC. Dielectric Withstand Voltage Electromagnetic Interference MIN NOM MAX UNITS Approved Line to Line Line to Ground 2600 B B 8 10 4 1 2 VDC Class kV V/M kV kV 10 2.0 M mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. MIN Operating Temperature Derate linearly above 50C by 2.5% per C. Storage Temperature Forced Air Cooling Temperature Coefficient Relative Humidity Shock Vibration At 100% load At 50% load Forced air cooling of 300 LFM is required if the internal fan option is not specified. Cooling air velocity is measured 1/4" above, at the middle of the chassis. Airflow direction is from the input section to the output section. 0C to 70C (after 15-minute warmup). Non-Condensing. Operating: 103mS, 3 axis, Halfsine. Non-operating: 103mS, 3 axis, Halfsine. Operating: 5-32 Hz 32-2000 Hz Sinusoidal Non-operating: MCD10156 Rev. 1.0, 20-Apr-10 Page 4 of 5 NOM 0 0 -55 0.02 5 MAX UNITS 10k 40k 50 70 85 ASL Ft. ASL Ft. C C C 0.05 95 20 40 0.02 1 6.15 %/C %RH G in (DA) GRMS GRMS www.power-one.com PFC375 AC-DC Series Data Sheet Options DESCRIPTION NOTES Fan Add "F" as a suffix to the model number to order integral fan. (provides required 300 LFM of forced air cooling). Add "M" as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric Mounting SIZE IMPACT 10.50" x 5.00" x 2.50" (266.7mm x 127.0mm x 63.5mm) 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm) Overall Size: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm) Input and Output Connections: 6-32 Screw Terminal on 0.375" (9.5mm) Centers Overall Length With Fan: 10.50" (266.7mm) Bus Bar Main Output, E1 & E2, 10-32 Screw Terminal Weight: 4.3 lb (1.95 kg) TERMINAL BLOCKS have 6-32 (PHILSLOT) screw connections on 0.375" (9.53mm) centers; open space clearance for connections is 0.31" (7.87mm). Rated current per connection is 20 Amps maximum. UL94V-0 thermoplastic rating. Recommended torque is 6-8 inch lbs. Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10156 Rev. 1.0, 20-Apr-10 Page 5 of 5 www.power-one.com