89
RFI Power Line Filters
1
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
WG Series
WG Series
High Performance, Low Cost Filter Ideal for Appliance Equipment
Maximum leakage current each Line to Ground:
A, B & C Models D, E & F Models
@ 120 VAC 60 Hz: .76 mA .10 mA
@250 VAC 50 Hz: 1.27 mA .20 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 16A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (T
a) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io= Ir(85-Ta)/45
• Cost-effective
• Tubular design
• WGA, WGB and WGC versions designed to
comply with leakage current for fixed appliances
not easily moved from one place to another
• WGD, WGE and WGF versions designed to comply
with leakage current requirements for appliances
which may be easily moved from one place to
another
• Available in a variety of styles
Ordering Information
16 WG A 1
Input / Output Style
1 – .250 [6.3] spade terminals
3 – Wire Leads
7 – RAST 5 connection
Leakage Current & Performance
A, B & C: for fixed appliances
A = Standard
B = Enhanced
C = High performance
D, E & F: for mobile appliances
D = Standard
E = Enhanced
F = High performance
WG Series
Current Rating
16A
Specifications
UL Recognized
CSA Certified
VDE Approved
Electrical Schematics
N(4)
GND
U (3)
Available Part Numbers
16WGA1 16WGA3 16WGA7
16WGB1 16WGB3 16WGB7
16WGC1 16WGC3 16WGC7
16WGD1 16WGD3 16WGD7
16WGE1 16WGE3 16WGE7
16WGF1 16WGF3 16WGF7
N
GND
With RAST 5 Connector (style 7)
WG_1 Style