DMU-30DCV Series www.murata-ps.com Ruggedized DC Voltmeters with Daylight Readable Auto-Dimming LED Displays FEATURES Measure and accurately display dc voltages in harsh environments Four input ranges: 200mVdc, 2Vdc, 20Vdc, and 200Vdc Daylight-readable LED display with automatic brightness adjustment Moisture & impact resistant package offers NEMA-4/IP65 protection Operates from universal 85-264Vac mains, or 110-300Vdc supplies Input circuit fully isolated from ac power supply Murata Power Solutions' DMU-30DCV series of daylight-readable dc voltmeters measure and display dc signals as low as 200mV and as high as 200V. Their large 0.56" (14.2mm) high super-bright red LED-display is readable in full sunlight. An auto-dimming circuit automatically adjusts the display brightness for all viewing conditions. DMU-30DCV series dc voltmeters are packaged in a rugged, one-piece polycarbonate plastic housing that features an integrated bezel and gasket assembly. In a typical installation, the housing is secured to a panel with six metallic threaded inserts, allowing the unit to meet NEMA-4 / IP65 requirements for moisture and impact resistance in outdoor applications. DMU-30DCV series dc voltmeters are available in a choice of four input ranges: 200mVdc (with 0.1mV resolution); 2Vdc (0.001V resolution); 20Vdc (0.01V resolution); and 200Vdc (0.1V resolution). The dc signal under measurement is electrically isolated from the unit's operating power source. DMU-30DCV series' miniature size and rugged package are perfect for industrial and high-reliability instrumentation, alternative power generators, and any other application which requires daylight readability and precise monitoring of dc voltages in harsh indoor / outdoor environments. Simply connect the input signal and an 85-264Vac source of operating power to the two rear-mounted terminal blocks and the unit is fully operational. TECHNICAL NOTES IMPORTANT! To ensure safe and reliable operation, DMU-30DCV dc voltmeters must be installed and serviced by qualified technical personnel. Contact Murata Power Solutions if there is any doubt regarding installation and/or operation. 1. Measurement Type: All DMU-30DCV series dc voltmeters achieve their excellent performance by employing a precision integrating analog-to-digital converter, metal film resistor dividers, and a high-stability voltage reference IC. The LED display is updated approximately 2.5 to 3 times per second. However, while some input filtering is provided, noisy signals may cause the displayed reading to vary by a few counts. CAL 1 2. Wiring: All ac supply (TB1) and input signal (TB2) wiring must be adequately rated for the voltages and currents they will carry, and must comply with any code or applicationmandated requirements pertaining to the user's specific installation. BRIGHTNESS ADJUST 2 1 2 TB1 TB2 + - REAR VIEW 85-264Vac Power Source Input Signal Figure 1. DMU-30DCV wiring diagram For full details go to www.murata-ps.com/rohs 3. Power Supply Polarity, Fusing, Wiring and Grounding: The power supply inputs (TB1-1 and TB1-2) on DMU-30DCV voltmeters are not polarity sensitive, that is, they have no "AC LO" or "AC HI" designations. These units do not include or require a connection to earth/chassis ground. Refer to Figure 1 for a typical wiring diagram. Wires specified in the Functional Specifications section must be used for making connections to DMU-30DCV series voltmeters. All power-supply and load wiring must be rated for the supply voltages and currents they will conduct and must comply with any code or application-mandated requirements pertaining to the user's specific installation. DMU-30DCV voltmeters are not internally fused. Terminal block TB1 is to be used only for powering the power meter's internal circuitry; it must not be used to supply power to external loads. The supply wires feeding these power meters must be fused with a 0.5A/250V time delay/time lag fuse, in accordance with applicable regulatory codes. Wire insulation must be stripped to within 10% of the stated dimensions, and wires should be inserted into TB1 such that their insulation is not pinched by the screw terminal. www.murata-ps.com/support MPM_DMU_30DCV.B01 Page 1 of 3 DMU-30DCV Series Ruggedized DC Voltmeters with Daylight Readable Auto-Dimming LED Displays TECHNICAL NOTES (continued) Performance/Functional Specifications Typical at TA = +25C, unless otherwise noted. 4. Calibration: Periodic recalibration of DMU-30DCV voltmeters is not required under normal indoor operating environments. However, operation in environments subject to vibration and/or extreme temperature variations should have their accuracy verified on a yearly basis. If recalibration is necessary, it should only be performed by qualified technical personnel. Calibration is performed with potentially lethal voltages applied to the DMU-30DCV and its associated wiring. A plastic, fully-insulated adjusting tool must be used to access the recessed calibration potentiometer located on the back of the unit (see Mechanical Specifications). Contact Murata Power Solutions if additional information is required regarding calibration, setup, or any other technical issue pertaining to DMU-30DCV dc voltmeters. 5. Minimum-Intensity Adjustment Potentiometer: Users can adjust the DMU-30DCV's minimum LED display brightness to suit their indoor viewing requirements by adjusting the 3/4-turn, rear-mounted intensity adjustment potentiometer. Please note, this potentiometer will have minimal impact on display brightness in high ambient light environments. The intensity adjustment potentiometer is factory preset to its mid-point position. As viewed from the rear of the meter, and with the model number label facing up, turning the potentiometer clockwise increases the LED display's intensity. See the Mechanical Specifications section for potentiometer locations. 6. Operation with Power Supplies Lower than 85Vac: In indoor applications where daylight readability (i.e., maximum display brightness) is not required, DMU-30DCV meters will meet their specified accuracy with ac supply voltages (TB1) well below 85Vac. While performance is not guaranteed, DMU30DCV voltmeters remain easily readable and accurate with ac supplies as low as 20Vac. 7. Panel Installation: All electrical connections to DMU-30DCV must be made after the meter is securely attached to the panel and with all input and supply voltages de-energized (off). Care must be exercised when attaching conductors to terminal blocks TB1 and TB2. The installed wire-positions should be such that minimal forces are applied to the terminal blocks or the voltmeter. In high-vibration environments, adequate strain reliefs must be used on all input and supply wiring. To ensure a secure and moisture/vibration resistant installation, use only the supplied hardware. Following the four-step sequence shown--being careful not to apply excessive force or twisting motions--insert the voltmeter into the panel opening. Tighten all six M3 metric screws to 3 inch-pounds (0.34Nm). See the Mechanical Specifications section for panel cutout, drill dimensions, and panel installation information. Ordering Information Model Input Range DMU-30DCV-0-DR-C 0 to 199.9mVdc DMU-30DCV-1-DR-C 0 to 1.999Vdc DMU-30DCV-2-DR-C 0 to 19.99Vdc DMU-30DCV-3-DR-C 0 to 199.9Vdc Min. Typ. Max. Units DMU-30DCV-0-DR-C 0 - 199.9 mVdc DMU-30DCV-1-DR-C 0 - 1.999 Vdc DMU-30DCV-2-DR-C 0 - 19.99 Vdc DMU-30DCV-3-DR-C 0 - 199.9 Vdc Input (TB2) Full Scale Input Range: Performance Sampling Rate 2.5 readings per second Accuracy Zero Reading (within 30 sec.) Temperature Drift (0 to +60C) Breakdown Voltage (TB1 to TB2) 0.4%FS 2 counts "-001" "000" "001" Cnts - 0.2 0.4 Cnts/C 2000 - - Vdc Supply Voltage (TB1) DMU-30DCV 85 - 264 Vac/4763Hz DMU-30DCV (total darkness) - 4 6 mA/4763Hz DMU-30DCV (full sunlight) - 40 50 mA/4763Hz Supply Current (TB1) Terminal Block Wiring (TB1 & TB2) Wire Size 16-22 AWG, Solid or stranded Insulation Strip Length 0.250 inches (6.35) Screw Tightening Torque 2.2 lb*in (0.25 N*m) 20% Rated Voltage 300Vac Display Display Type and Size Daylight readable, auto-dimming, 31/2 digit, 0.56"/14.2mm high red LED Decimal Point Fixed, model dependent Overrange Indication "1_ _ _" Physical/Environmental Operating Temperature -25 - +60 C Storage Temperature -40 - +75 C 0 - 85 % Humidity (non-condensing) Dimensions See mechanical specifications Weight 1.3 ounces (36 grams) nominal Display reading is set to "1888". Specified power supply currents are steady state; larger surge currents can occur at initial application of ac power. Power supply input (TB1) set to 120Vac/60 Hz. See www.murata-ps.com/dpm-availability for model-specific availability. www.murata-ps.com/support MPM_DMU_30DCV.B01 Page 2 of 3 DMU-30DCV Series Ruggedized DC Voltmeters with Daylight Readable Auto-Dimming LED Displays Mechanical Dimensions: Inches (mm) Tolerances: 2 PL DEC 0.02 (0.51) 3 PL DEC 0.010 (0.254) 2.85 (72.39) M3 INSERT 0.10 (2.54) DEPTH 1.5 (38.1) 1.60 (40.64) CAL BRIGHTNESS ADJUST 1.97 (50.0) 0.26 (6.6) 1 2 1 TB1 PWR SUPPLY INPUT FRONT VIEW 2 TB2 REAR VIEW + VIN - SIGNAL INPUT RECOMMENDED DRILL AND PANEL CUTOUT 2.118 (53.8) Note: The supplied M3 screws and washers will accommodate panel thicknesses from 0.060 to 0.090 inches (1.52 to 2.28 mm). 1.30 (33.02) Tighten screws to 3.5-4.5 in-lbs (0.4-0.5 Nm). PANEL CUTOUT 0.136 (3.45) DIA (6 REQUIRED) 0.878 (22.3) INTERNAL CORNER RADII 0.032 (0.81) MAX. 1.26 (32.00) 2.52 (64.00) PANEL INSTALLATION Step 1. Step 2. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Step 3. Step 4. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2015 Murata Power Solutions, Inc. www.murata-ps.com/support MPM_DMU_30DCV.B01 Page 3 of 3 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Murata: DMU-30DCV-0-DR-C DMU-30DCV-1-DR-C DMU-30DCV-2-DR-C DMU-30DCV-3-DR-C