Features
75 Ohm Impedance
Input Terminated
Positive Voltage Control
High Isolation: 65 dB at 870 MHz
0.5 micron GaAs PHEMT Process
Lead-Free 4 mm 20-Lead PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
M/A-COM’s MASWSS0103 is a GaAs PHEMT
MMIC single pole double throw (SPDT) switch in a
lead-free 4 mm 20-lead PQFN package. The
MASWSS0103 is ideally suited for applications
where low control voltage, high isolation, small size
and low cost are required.
Typical applications are to replace mechanical
relays in CATV systems. This part can be used in
all 75 Ω systems operating up to 1 GHz.
The MASWSS0103 is fabricated using a 0.5 micron
gate length GaAs PHEMT process. The process
features full passivation for performance and
reliability.
Functional Schematic
GND
G1
GND
V2
V1
RF1
GND
GT1
GI1 GND RFC GND GI2
GT2
GND
RF2
GND
GND
V1 G2
GND
G1
GND
V2
V1
RF1
GND
GT1
GI1 GND RFC GND GI2
GT2
GND
RF2
GND
GND
V1 G2
Ordering Information
Part Number Package
MASWSS0103TR-3000 13 inch, 3000 piece reel
MASWSS0103SMB Sample Test Board
(Includes 5 Samples)
1: Reference Application Note M513 for reel size information.
Pin Configuration 1
Pin No. Pin Name Description
1 GND Ground
2 GND Ground
3 RF1 RF Port 1
4 GND Ground
5 GT1 RF Ground
6 GI1 RF Ground
7 GND Ground
8 RFC RF Common Port
9 GND Ground
10 GI2 RF Ground
11 GT2 RF Ground
12 GND Ground
13 RF2 RF Port 2
14 GND Ground
15 GND Ground
16 G2 RF Ground
17 V1 Control 1
18 V2 Control 2
19 V1 Control 1
20 G1 RF Ground
1. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
MASWSS0103
2
SPDT High Isolation CATV Switch
5 1000 MHz
Rev V1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Parameter Absolute Maximum
Input Power
(5 - 1000 MHz, 2.9 V Control)
+32 dBm
Operating Voltage +8.5 volts
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
Absolute Maximum Ratings 3,4
3. Exceeding any one or combination of these limits may cause
permanent damage.
4. M/A-COM does not recommend sustained operation near
these survivability limits.
5. 1 = +2.9 to +5 V, 0 = 0 + 0.2 V.
Truth Table 5
V1 V2
RFC - RF1 RFC - RF2
1 0 On Off
0 1 Off On
Electrical Specifications: TA = 25°C, Z0 = 75 Ω2, VC = 0 V / 2.9 V, PIN = 10 dBm
Parameter Test Conditions Units Min. Typ. Max.
Insertion Loss 5 - 50 MHz
50 - 1000 MHz
dB
dB
0.75
1.0
1.2
Isolation 5 - 50 MHz
50 - 1000 MHz
dB
dB
60
100
63
Return Loss (On) 5 - 50 MHz
50 - 1000 MHz
dB
dB
28
16
Return Loss (Off) 5 - 50 MHz
50 - 1000 MHz
dB
dB
26
16
IP3 Two Tone, +15 dBm/tone, 6 MHz spacing, > 50 MHz
VC = 0 V / 2.9 V
VC = 0 V / 5.0 V
dBm
dBm
47
52
Trise, Tfall 10% to 90% RF, 90% to 10% RF nS 8
Ton, Toff 50% control to 90% RF, 50% control to 10% RF nS 18
Transients In Band mV 70
Control Current |VC| = 2.9 V µA 5 10
Application Schematic
G1
GND
V1
RF1
GND
GT1
GI1
GND
RFC
GND
GI2
GT2
GND
RF2
GND
V1 G2
GND
V2
GND
GND GND
GND
GND
C1 C2
C3
C5
C6
C4 C9
C8
C7
C10 C11
G1
GND
V1
RF1
GND
GT1
GI1
GND
RFC
GND
GI2
GT2
GND
RF2
GND
V1 G2
GND
V2
GND
GND GND
GND
GND
C1 C2
C3
C5
C6
C4 C9
C8
C7
C10 C11
C1 - C9 = 0.01 µF, RF Bypass Capacitors
C10 - C11 = 0.01 µF, Logic Control Decoupling Capacitors
2. External 0.01 µF DC blocking capacitors are required on all RF In/Out and RF ground ports. See Application Schematic.
MASWSS0103
3
SPDT High Isolation CATV Switch
5 1000 MHz
Rev V1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Typical Performance Curves RF1 Isolation
Off Return Loss
RF2 Isolation
Insertion Loss
0.0
0.5
1.0
1.5
0200 400 600 800 1000 1200
+25°C
+85°C
-40°C
Frequency (MHz)
-40
-30
-20
-10
0
0200 400 600 800 1000 1200
+25°C
+85°C
-40°C
Frequency (MHz)
-40
-30
-20
-10
0
0200 400 600 800 1000 1200
+25°C
+85°C
-40°C
Frequency (MHz)
50
60
70
80
90
0200 400 600 800 1000 1200
+25°C
+85°C
-40°C
Frequency (MHz)
50
60
70
80
90
0200 400 600 800 1000 1200
+25°C
+85°C
-40°C
Frequency (MHz)
On Return Loss
MASWSS0103
4
SPDT High Isolation CATV Switch
5 1000 MHz
Rev V1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Lead-Free 4 mm 20-Lead PQFN
Reference Application Note M538 for lead-free solder reflow recommendations.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
MASWSS0103
5
SPDT High Isolation CATV Switch
5 1000 MHz
Rev V1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.