https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Hybrid motor starter for reversing 3~AC motors up to 550VAC, 2.4A output current, adjustable overload TM shutdown and safe emergency stop up to PLe/SIL 3 and SmartWire-DT adapter as a set. Your advantages 22.5 mm wide Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e Reduction in wiring Long service life Space saving Adjustable current for bimetal function Low-wear switching Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356712811 Weight per Piece (excluding packing) 360.000 g Custom tariff number 85371098 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 165 mm Depth 114 mm 04/18/2021Page1/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Technical data Ambient conditions Ambient temperature (operation) -5 C ... 55 C (observe derating) Ambient temperature (storage/transport) -40 C ... 80 C Maximum altitude 2000 m Degree of protection IP20 Device supply Rated control circuit supply voltage US 24 VDC Control supply voltage range 19.2 VDC ... 30 VDC Rated control supply current IS 40 mA Type of protection Surge protection Reverse polarity protection Input data Input name Control input right/left Rated actuating voltage UC 24 VDC Triggering voltage range 19.2 VDC ... 30 VDC Rated actuating current IC 5 mA Switching threshold 9.6 V ("0" signal) 19.2 V ("1" signal) Switching level < 5 VDC (For EMERGENCY STOP) Typical turn-off time < 30 ms Output data load output Output name AC output Rated operating voltage Ue 500 VAC Operating voltage range 42 VAC ... 550 VAC Mains frequency 50/60 Hz Load current range 180 mA ... 2.4 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 changeover contact Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) 04/18/2021Page2/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Technical data General Motor starter type Reversing starter Switching frequency 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 4.1 W Minimum power dissipation 0.88 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data Connection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm ... 2.5 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm 5 lbf-in. ... 7 lbf-in. Connection data 2 Connection name Load circuit Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm ... 2.5 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm 5 lbf-in. ... 7 lbf-in. Insulation characteristics Rated insulation voltage 500 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 04/18/2021Page3/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Technical data Insulation characteristics Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1) at operating voltage 300 V AC Safe isolation (EN 50178) at operating voltage 300 V AC Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300...500VAC Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit 300 V AC Safe isolation (EN 50178) in the auxiliary circuit 300 V AC Standards and Regulations Designation Standards/regulations Standards/regulations IEC60947-1 EN60947-4-2 IEC61508 ISO13849 Conformance/approvals Designation ATEX Identification II (2) G [Ex e] [Ex d] [Ex px] II (2) D [Ex t] [Ex p] Certificate PTB 07 ATEX 3145 Designation UL approval Certificate NLDX.E228652 NRNT.E172140 Designation Safety Integrity Level (SIL, IEC61508) Identification 3 Additional text Safe shutdown Designation Safety Integrity Level (SIL, IEC61508) Identification 2 Additional text Motor protection Designation Performance Level (ISO13849) Identification e Additional text Safe shutdown Designation Category (ISO13849) Identification 3 Additional text Safe shutdown UL data 04/18/2021Page4/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Technical data UL data SCCR 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) FLA 2.4 A (480VAC) Group installation 20 A (class RK5, SCCR 5kA, 24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, 24 - 14 AWG max, solid and stranded) Category code NLDX / NRNT Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram EM-SWD Dimensional drawing CONTACTRON n in 1" " 114,5 22,5 + RESET MAN. AUTO 1/L1 I RESET 3/L2 Us R L 5/L3 2/T1 4/T2 & Error EN EN Logic & P 6/T3 165 SmartWire-DT TM SWD - EN EN+ EN- 04/18/2021Page5/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Application drawing Controller MRESET STOP RUN/PROG RESET PRG 1.1 2.1 1.1 2.1 1.1 2.1 1.1 2.1 1.2 2.2 1.2 2.2 1.2 2.2 1.2 2.2 1.3 2.3 1.3 2.3 1.3 2.3 1.3 2.3 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 LINK TM SmartWireDT line Start Ethernet connection Stop Reset 0511 01 SWD EN EN EN SWD EN EN EN SWD EN EN EN SWD EN EN EN EN EN SWD EN +15V A1 S34 S33 S11 24V 0V S12 S21 S22 A2 M1 M2 US R L MAN RES AUT E 97 96 95 US R L MAN RES AUT E 97 96 95 SWD POW DP Config. M3 M5 M4 Power Config. PSR-ESA4 AUX Gateway Reset 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 4,0 2,4 0,18 2,4A PWR Err L R Reset max. 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 4,0 9,0 PWR Err L R Reset max. Network termination plug 1,5 9A PWR Err L R Reset 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 Emergency stop 9,0 1,5 2,4A max. 9A PWR Err L R Reset 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 ELRH5-IES-SC-24DC/500AC-9 0,87 2,4 0,18 K2 6,5 ELRH5-IES-SC-24DC/500AC-9 0,87 max. PWR Err L R US R L MAN RES AUT E 97 96 95 6,5 ELRH5-IES-SC-24DC/500AC-2 24V 0V 0,6 0,6A 0,075 US R L MAN RES AUT E 97 96 95 1,63 ELRH5-IES-SC-24DC/500AC-2 POW 0,25 max. US R L MAN RES AUT E 97 96 95 1,63 ELRH5-IES-SC-24DC/500AC-0,6 ETH1 ETH2 FOR LAN ONLY EU5C-SED-EIP-MODTCP PXC RS232 K1 0,39 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 31 13 14 32 33 24 PSR safety relays Hybrid motor starters TM with SmartWireDT connection Circuit diagram F1 L1 F2 L2 F3 L3 SWD SWD + EN+ EN- - SWD EN SWD AUX EM SWD-ADAPTER GND_E MAN RES AUT CONTACTRON N in1 6/T3 2/T1 4/T2 POW 96 95 97 EU5C SWD-DP PXC L PROFIBUS-DP 5/L3 1/L1 3/L2 Config. US GND R M 3~ PE Wiring example without EMERGENCY STOP 04/18/2021Page6/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Circuit diagram F1 L1 F2 L2 F3 L3 +24V DC GND S22 S12 S21 S11 S1 PSR-SCP-24UC/ESA4/2x1/1x2 A1 A2 13 23 14 24 S33 S34 SWD SWD + EN+ EN- - SWD EN SWD AUX EM SWD-ADAPTER GND_E MAN RES AUT CONTACTRON N in1 6/T3 2/T1 4/T2 POW 96 95 97 EU5C SWD-DP PXC L PROFIBUS-DP 5/L3 1/L1 3/L2 Config. US GND R M 3~ PE EMERGENCY STOP wiring example (two-channel) Classifications eCl@ss eCl@ss 10.0.1 27370905 eCl@ss 11.0 27370905 eCl@ss 4.0 27021100 eCl@ss 4.1 27021100 eCl@ss 5.0 27024000 eCl@ss 5.1 27024000 04/18/2021Page7/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Classifications eCl@ss eCl@ss 6.0 27024000 eCl@ss 7.0 27024002 eCl@ss 9.0 27370905 ETIM ETIM 2.0 EC001037 ETIM 3.0 EC001037 ETIM 4.0 EC001037 ETIM 6.0 EC001037 ETIM 7.0 EC001037 UNSPSC UNSPSC 6.01 30211915 UNSPSC 7.0901 39121514 UNSPSC 11 39121514 UNSPSC 12.01 39121514 UNSPSC 13.2 25173902 UNSPSC 18.0 25173902 UNSPSC 19.0 25173902 UNSPSC 20.0 25173902 UNSPSC 21.0 25173902 Accessories Accessories Assembly adapter Power distribution board-EM-CPS-225-1002634 (R) Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 225 mm 04/18/2021Page8/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Power distribution board-EM-CPS-405-1002635 (R) Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 405 mm Connection module-EM-CPS-TB3/63A-1002633 Connection module with integrated spring-loaded terminals for cables from 1.5 to 16mm, 3-pos., maximum 63A Assembly tool Tool-SWD4-CRP-1 PXC-2903110 SmartWire DTTM pliers for device plugs Bridge Jumper-BRIDGE- 4-3M-2901659 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Cover 04/18/2021Page9/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Covering hood-BRIDGE COVER-2906240 The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge. Device marking Plastic label-US-EMLP (15X5)-0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 Plastic label-UC-EMLP (15X5)-0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 Loop bridge Jumper-BRIDGE- 2-2900746 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE- 3-2900747 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. 04/18/2021Page10/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Jumper-BRIDGE- 4-2900748 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE- 5-2900749 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE- 6-2900750 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE- 7-2900751 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE- 8-2900752 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. 04/18/2021Page11/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Jumper-BRIDGE- 9-2900753 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE-10-2900754 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 0.3m, with ferrules. Jumper-BRIDGE- 2-1M-2901542 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 1m Jumper-BRIDGE- 3-1M-2901655 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 1m Jumper-BRIDGE- 4-1M-2901658 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 1m 04/18/2021Page12/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Jumper-BRIDGE- 5-1M-2901544 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 1m Jumper-BRIDGE- 6-1M-2901649 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 1m Jumper-BRIDGE- 2-3M-2901543 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Jumper-BRIDGE- 3-3M-2901656 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Jumper-BRIDGE- 5-3M-2901545 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m 04/18/2021Page13/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Jumper-BRIDGE- 6-3M-2901697 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Jumper-BRIDGE- 7-3M-2901698 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Jumper-BRIDGE- 8-3M-2901700 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Jumper-BRIDGE- 9-3M-2901701 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m Jumper-BRIDGE-10-3M-2901702 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting cable: 3m 04/18/2021Page14/15 https://www.phoenixcontact.com/us/products/2903117 Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117 Accessories Jumper-BRIDGE- 2- 2M/0,3M-2909897 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, cable length between the modules: 0.3m, connecting cable: 2m Jumper-BRIDGE- 3- 2M/0,3M-2909898 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, cable length between the modules: 0.3m, connecting cable: 2m Jumper-BRIDGE- 4- 2M/0,3M-2909899 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, cable length between the modules: 0.3m, connecting cable: 2m Mounting material Plug-SWD4-8SF2-5 PXC-2903107 TM SmartWire DT device plug, 8-pos. Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 04/18/2021Page15/15