Hybrid motor starter for reversing 3~AC motors up to 550VAC, 2.4A output current, adjustable overload
shutdown and safe emergency stop up to PLe/SIL 3 and SmartWire-DT adapter as a set.
Your advantages
22.5 mm wide
Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e
Reduction in wiring
Long service life
Space saving
Adjustable current for bimetal function
Low-wear switching
Key Commercial Data
Packing unit 1 pc
GTIN
GTIN 4046356712811
Weight per Piece (excluding packing) 360.000 g
Custom tariff number 85371098
Country of origin Germany
Technical data
Dimensions
Width 22.5 mm
Height 165 mm
Depth 114 mm
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page2/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Technical data
Ambient conditions
Ambient temperature (operation) -5 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum altitude ≤ 2000 m
Degree of protection IP20
Device supply
Rated control circuit supply voltage US24 VDC
Control supply voltage range 19.2 VDC ... 30 VDC
Rated control supply current IS40 mA
Type of protection Surge protection
Reverse polarity protection
Input data
Input name Control input right/left
Rated actuating voltage UC24 VDC
Triggering voltage range 19.2 VDC ... 30 VDC
Rated actuating current IC5 mA
Switching threshold 9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level < 5 VDC (For EMERGENCY STOP)
Typical turn-off time < 30 ms
Output data load output
Output name AC output
Rated operating voltage Ue500 VAC
Operating voltage range 42 VAC ... 550 VAC
Mains frequency 50/60 Hz
Load current range 180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10A
Cooling time 20 min. (for auto reset)
Leakage current 0 mA
Type of protection Surge protection
Output data reply output
Output name Acknowledge output
Note Confirmation: floating change-over contact, signal contact
Contact type 1 changeover contact
Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15)
2 A (24 V, DC13)
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page3/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Technical data
General
Motor starter type Reversing starter
Switching frequency ≤ 2 Hz (Load-dependent)
Mounting position vertical (horizontal DIN rail, motor output below)
Mounting type DIN rail mounting
Assembly instructions alignable, for spacing see derating
Operating mode 100% operating factor
Maximum power dissipation 4.1 W
Minimum power dissipation 0.88 W
Operating voltage display Green LED
Status display Yellow LED
Indication Red LED
Connection data
Connection name Control circuits
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Connection data 2
Connection name Load circuit
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Insulation characteristics
Rated insulation voltage 500 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page4/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Technical data
Insulation characteristics
Designation Insulation characteristics between the control input and control supply
voltage, and auxiliary circuit to the main circuit
Insulation Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
Safe isolation (EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300...500VAC
Designation Isolation characteristics between the control input and control supply
voltage to auxiliary circuit
Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Standards and Regulations
Designation Standards/regulations
Standards/regulations IEC60947-1
EN60947-4-2
IEC61508
ISO13849
Conformance/approvals
Designation ATEX
Identification  II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]
Certificate PTB 07 ATEX 3145
Designation UL approval
Certificate NLDX.E228652
NRNT.E172140
Designation Safety Integrity Level (SIL, IEC61508)
Identification ≤3
Additional text Safe shutdown
Designation Safety Integrity Level (SIL, IEC61508)
Identification 2
Additional text Motor protection
Designation Performance Level (ISO13849)
Identification e
Additional text Safe shutdown
Designation Category (ISO13849)
Identification ≤3
Additional text Safe shutdown
UL data
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page5/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Technical data
UL data
SCCR 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
FLA 2.4 A (480VAC)
Group installation 20 A (class RK5, SCCR 5kA, 24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, 24 - 14 AWG max, solid and stranded)
Category code NLDX / NRNT
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Block diagram
MAN.
AUTO
SmartWire-DT
Us
L
R
RESET
Logic
& µP
RESET
1/L1
3/L2
5/L3
2/T1
4/T2
6/T3
& Error
I
EN+
EN-
TM
+
-
EM-SWD CONTACTRON n in 1"
"
Dimensional drawing
SWD
EN
EN
EN
22,5
114,5
165
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page6/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Application drawing
AUX
ETH2 ETH1
FORLANONLY
EU5C-SED-EIP-MODTCPPXC
RS232
24V
0V
POW 24V
0V
DP Config.
Config.
SWD
POW
1.1 2.1
1.2 2.2
1.3 2.3
1.4 2.4
1.1 2.1
1.2 2.2
1.3 2.3
1.4 2.4
1.1 2.1
1.2 2.2
1.3 2.3
1.4 2.4
1.1 2.1
1.2 2.2
1.3 2.3
1.4 2.4
RESET
PRG
RUN/PROG
MRESET
STOP
LINK
PSR-ESA4
A1 S34 S33
S22S21
S12 A2
S11
13
33
31
32 24
14
Power
K1
K2
0511
01
+15V
UR L
E
AUTRES
MAN
97 96 95
S
max.
PWR
Err
L
R
Reset
ELRH5-IES-SC-24DC/500AC-0,6
0,6A
M1
EN
EN
EN
SWD
1/L1 3/L2 5/L3
2/T1 4/T2 6/T3
0,39
0,6
0,25
0,075
UR L
E
AUTRES
MAN
97 96 95
S
max.
PWR
Err
L
R
Reset
ELRH5-IES-SC-24DC/500AC-2
2,4A
M2
EN
EN
EN
SWD
1/L1 3/L2 5/L3
2/T1 4/T2 6/T3
1,63
2,4
0,87
0,18
UR L
E
AUTRES
MAN
97 96 95
S
max.
PWR
Err
L
R
Reset
ELRH5-IES-SC-24DC/500AC-2
2,4A
M3
EN
EN
EN
SWD
1/L1 3/L2 5/L3
2/T1 4/T2 6/T3
1,63
2,4
0,87
0,18
UR L
E
AUTRES
MAN
97 96 95
S
max.
PWR
Err
L
R
Reset
ELRH5-IES-SC-24DC/500AC-9
9A
M4
EN
EN
EN
SWD
1/L1 3/L2 5/L3
2/T1 4/T2 6/T3
6,5
9,0
4,0
1,5
UR L
E
AUTRES
MAN
97 96 95
S
max.
PWR
Err
L
R
Reset
ELRH5-IES-SC-24DC/500AC-9
9A
M5
EN
EN
EN
SWD
1/L1 3/L2 5/L3
2/T1 4/T2 6/T3
6,5
9,0
4,0
1,5
Controller
SmartWireDT line
TM
Emergencystop
Start
Hybridmotorstarters
withSmartWireDT connection
TM
Stop Reset
Networktermination
plug
PSRsafetyrelays
Ethernetconnection
Gateway
Circuit diagram
L1
L2
L3
F1
F2
F3
M
3~
PE
EM SWD-ADAPTER
CONTACTRON N in1
EU5C SWD-DP PXC
2/T1 1/L1
3/L2
5/L3
4/T2
6/T3
96 95 97
USGND R
+
L
EN+ EN–
GND_E MAN RES AUT
SWD
SWD EN
SWD
AUX
Config.
PROFIBUS-DP
POW
SWD
Wiring example without EMERGENCY STOP
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page7/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Circuit diagram
L1
L2
L3
+24V DC
GND
F1
F2
F3
S11
S21
S12
S22
13
14
23
24
A1 S33A2 S34
M
3~
PE
EM SWD-ADAPTER
CONTACTRON N in1
EU5C SWD-DP PXC
PSR-SCP-24UC/ESA4/2x1/1x2
2/T1 1/L1
3/L2
5/L3
4/T2
6/T3
96 95 97
USGND R
+
L
EN+ EN–
GND_E MAN RES AUT
SWD
SWD EN
SWD
S1
AUX
Config.
PROFIBUS-DP
POW
SWD
EMERGENCY STOP wiring example (two-channel)
Classifications
eCl@ss
eCl@ss 10.0.1 27370905
eCl@ss 11.0 27370905
eCl@ss 4.0 27021100
eCl@ss 4.1 27021100
eCl@ss 5.0 27024000
eCl@ss 5.1 27024000
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page8/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Classifications
eCl@ss
eCl@ss 6.0 27024000
eCl@ss 7.0 27024002
eCl@ss 9.0 27370905
ETIM
ETIM 2.0 EC001037
ETIM 3.0 EC001037
ETIM 4.0 EC001037
ETIM 6.0 EC001037
ETIM 7.0 EC001037
UNSPSC
UNSPSC 6.01 30211915
UNSPSC 7.0901 39121514
UNSPSC 11 39121514
UNSPSC 12.01 39121514
UNSPSC 13.2 25173902
UNSPSC 18.0 25173902
UNSPSC 19.0 25173902
UNSPSC 20.0 25173902
UNSPSC 21.0 25173902
Accessories
Accessories
Assembly adapter
Power distribution board-EM-CPS-225-1002634
Modular power distribution board with CrossLink® interface, 125 A, 3-pos., touch-proof and protection against polarity
reversal, width: 225 mm
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page9/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Power distribution board-EM-CPS-405-1002635
Modular power distribution board with CrossLink® interface, 125 A, 3-pos., touch-proof and protection against polarity
reversal, width: 405 mm
Connection module-EM-CPS-TB3/63A-1002633
Connection module with integrated spring-loaded terminals for cables from 1.5 to 16mm², 3-pos., maximum 63A
Assembly tool
Tool-SWD4-CRP-1 PXC-2903110
SmartWire DT™ pliers for device plugs
Bridge
Jumper-BRIDGE- 4-3M-2901659
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Cover
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page10/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Covering hood-BRIDGE COVER-2906240
The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently
be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.
Device marking
Plastic label-US-EMLP (15X5)-0828790
Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID, THERMOMARK
PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm,
Number of individual labels: 189
Plastic label-UC-EMLP (15X5)-0819301
Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARKIDCOLOR, BLUEMARKID, BLUEMARK CLED,
PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels:
10
Loop bridge
Jumper-BRIDGE- 2-2900746
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE- 3-2900747
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page11/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Jumper-BRIDGE- 4-2900748
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE- 5-2900749
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE- 6-2900750
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE- 7-2900751
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE- 8-2900752
3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page12/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Jumper-BRIDGE- 9-2900753
3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE-10-2900754
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 0.3m, with ferrules.
Jumper-BRIDGE- 2-1M-2901542
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 1m
Jumper-BRIDGE- 3-1M-2901655
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 1m
Jumper-BRIDGE- 4-1M-2901658
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 1m
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page13/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Jumper-BRIDGE- 5-1M-2901544
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 1m
Jumper-BRIDGE- 6-1M-2901649
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 1m
Jumper-BRIDGE- 2-3M-2901543
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Jumper-BRIDGE- 3-3M-2901656
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Jumper-BRIDGE- 5-3M-2901545
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page14/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Jumper-BRIDGE- 6-3M-2901697
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Jumper-BRIDGE- 7-3M-2901698
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Jumper-BRIDGE- 8-3M-2901700
3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Jumper-BRIDGE- 9-3M-2901701
3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
Jumper-BRIDGE-10-3M-2901702
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5mm housing width, connecting
cable: 3m
https://www.phoenixcontact.com/us/products/2903117
04/18/2021Page15/15
Hybrid motor starter-ELR H5-IES-SC-SWD/500AC-2-2903117
Accessories
Jumper-BRIDGE- 2- 2M/0,3M-2909897
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5mm housing width, cable length
between the modules: 0.3m, connecting cable: 2m
Jumper-BRIDGE- 3- 2M/0,3M-2909898
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5mm housing width, cable length
between the modules: 0.3m, connecting cable: 2m
Jumper-BRIDGE- 4- 2M/0,3M-2909899
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5mm housing width, cable length
between the modules: 0.3m, connecting cable: 2m
Mounting material
Plug-SWD4-8SF2-5 PXC-2903107
SmartWire DT device plug, 8-pos.
Phoenix Contact 2021 © - all rights reserved