AXICOM Telecom-, Signal and RF Relays Cradle Relay S V23054 / V23062 108-98014 * Nov. 07 * Rev. C * ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties (and all express warranties, except as otherwise stated in this datasheet) regarding the information contained herein, including but not limited to any implied warranties or merchantability or fitness for a particular purpose. It is recommended that you test any new or replacement product before incorporating into a system. The dimensions in this datasheet are for reference purpose only and are subject to change without notice. Specifications are subject to change without notice. Index Dimensions Coil Data and operating range Relay Code Coil Data and Ordering Information Instructions for Impulse Operation Contact Data Insulation / General Data All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 6 7 9 12 13 16 2 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Hand solder and plug-in relay, for DC operation, non-polarized, non-latching ROHS compliant (Directive 2002/95/EC) as per product date code 0501. Features * Stronger magnet system and thus wider voltage range than cradle relay N * highly reliable * Contacts for signal loads and currents up to 5 A * AC and DC, latching and non-latching, coils operating voltage 6 V ... 220 V * Multi purpose relay * Great variety of contact arrangements and materials to meet specific applications * Sockets for easy and quick mounting of relays (see data sheet Accessories) Typical applications * Press controls with high safety requirements (forcibly guided springs) * Traffic and railroad signalling * Motor vehicle traffic controls Relay types * Size I or II, depending on contact set * Standard contact sets with max. 6 changeover contacts or 6 make contacts * Single or bifurcated contacts * Hand solder terminals also for plug-in connection with screw fixing * Dust-protected with plastic cover, V23054-XXX * Hermetically sealed with metal enclosure, V23062-XXX All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Dimensions Type V23054-Cxxx Size I Dimensions in mm Type V23054-Dxxx Size II Hand solder terminals, silver-plated Also for plug-in connection and screw fixing With earth terminal Dust-protected Type V23054-Exxx Size III Hand solder terminals, silver-plated Also for plug-in connection and screw fixing With earth terminal Dust-protected For sockets and hold-down springs see data sheet Accessories All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Dimensions Type V23062-Axxx Size I Dimensions in mm Type V23062-Bxxx Size II Hand solder terminals, silver-plated Also for plug-in connection and screw fixing With earth terminal hermeticaly sealed with metal enclosure For sockets and hold-down springs see data sheet Accessories All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data and operating range Nominal voltage from 6 Vdc to 220 Vdc Typical nominal power consumption, at 20 C Class of the operative range acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 Operating voltage (according to the coil type) 1W 2 max. 92% of the nominal voltage Terminals: Coil with 1 winding Start 4 End 1 Coil with 2 windings (upon request) Start 3 End 2 for winding I Start 4 End 1 for winding II The minimum voltage UI depends on the contact set and the ambient temperature, the maximum voltage UII only depends on the ambient temperature. Between minimum voltage UI tamb and operating voltage U a safety margin of approx. 20% is recommended. UI tamb (1.2) < UI UII tamb UI tamb = UI * U20 C * kI tamb UII tamb = UIl 20 C * kII tamb tamb = Ambient temperature U = Operating voltage UI tamb = Minimum voltage at ambient temperature, tamb UII tamb = Maximum voltage at ambient temperature, tamb kI and kII = Factors Note: Instructions for impulse operation see data sheet cradle relay N Ambient temperature tamb [C] All specifications subject to change. Consult Tyco Electronics for latest specifications. 6 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Relay Code V 2 3 0 5 4 Identification of the cradle relay S, dust protected Relay type C = D = E = Size I Size II Size III 0 1 2 3 standard version fitted with contact sets F (block 3) for higher test voltage contact sets F and higher test voltage winding / frame = = = = Coil number Version see page 9 011 = 6V 015 = 12V 020 = 24V 026 = 60V 004 = 110V 013 = 125V 003 = 220V Nominal voltage Contact set / type of contact see page 13/14 Ordering example: V23054-D0020-B110 Cradle relay S, size II, standard version, coil 24 Vdc, 4 changeover contact set, single contacts, contact material silver, gold-flashed Note: The ordering scheme enables a multitude of variations. However, not all variations are defined as construction specifications (ordering code) and thus in the current delivery program. Special design can be carried out to customer specifications. Please contact your local representative. All specifications subject to change. Consult Tyco Electronics for latest specifications. 7 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Relay Code V 2 3 0 6 2 Identification of the cradle relay S, hermetically sealed Relay type A = B = Size I Size II 0 1 2 3 standard version fitted with contact sets F (block 3) for higher test voltage contact sets F and higher test voltage winding / frame = = = = Coil number Version see page 11 011 = 6V 015 = 12V 020 = 24V 026 = 60V 004 = 110V 013 = 125V 003 = 220V Nominal voltage Contact set / type of contact see page 13/14 Ordering example: V23062-B0020-C110 Cradle relay S, size II, standard version, coil 24 Vdc, 4 changeover contact set, bifurcated contacts, contact material silver, gold-flashed Note: The ordering scheme enables a multitude of variations. However, not all variations are defined as construction specifications (ordering code) and thus in the current delivery program. Special design can be carried out to customer specifications. Please contact your local representative. All specifications subject to change. Consult Tyco Electronics for latest specifications. 8 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data (values at 23 C) Nominal voltage Unom Vdc Operate/set voltage range Ordering Information Coil power Coil Resistance / 15 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc mW 190 18 21.5 31 240 145 190 39 94 39 39 50 50 50 66 66 94 94 94 240 240 145 145 1`008 1`108 845 1`026 1`936 1`315 1`008 914 947 914 914 975 975 975 1`066 1`066 947 947 947 1`936 1`936 1`315 1`315 15500 130 185 390 25000 9200 15500 630 3800 630 630 1050 1050 1050 1900 1900 3800 3800 3800 25000 25000 9200 9200 V23054C13B104 V23054C15B104 V23054C16B104 V23054C19C104 V23054C2003C404 V23054C2004B104 V23054C2013B104 V23054C2020B104 V23054C2026C104 V23054C20B104 V23054C20C104 V23054C21B104 V23054C21C104 V23054C21C404 V23054C22B104 V23054C22C104 V23054C26B104 V23054C26C104 V23054C26C404 V23054C3B104 V23054C3C104 V23054C4B104 V23054C4C104 2-1419172-8 1393812-6 1393812-7 1422019-3 3-1393812-2 3-1393812-3 3-1393812-4 3-1393812-5 3-1393812-6 1-1393812-0 1-1393812-1 1-1393812-2 1-1393812-3 1-1393812-4 1-1393812-5 1-1393812-6 2-1393812-0 2-1393812-3 2-1393812-4 1393812-2 1393812-3 1393812-4 1393812-5 50 66 18 50 975 1`066 1`108 975 1050 1900 130 1050 V23054C1021F106 V23054C1022F105 V23054C3015F105 V23054C3021F106 3-1393812-0 3-1393812-1 1422019-5 3-1393812-7 V23054-CXXXX standard, size I 125 59 12 4.7 12.5 5.4 20 10.5 220 98 110 44 125 59 24 10.5 60 36 24 10.5 24 13 32 14.5 32 17.5 32 17.5 45 19 45 24 60 29 60 36 60 36 220 79 220 98 110 44 110 53.5 V23054-CXXXX 5A, size I 32 14.5 45 19 12 4.7 32 14.5 Further coil versions are available on request. All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data (values at 23 C) Nominal voltage Unom Operate/set voltage range Ordering Information Coil power Coil Resistance / 15 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc mW V23054-DXXXX standard, size II 125 59 12 4.7 12.5 5.4 16 7 16 7 20 10.5 20 10.5 20 10.5 220 79 125 59 24 10.5 32 14.5 32 14.5 60 29 60 29 24 10.5 24 10.5 24 13 24 13 32 14.5 32 17.5 45 19 45 24 60 29 60 29 60 43 60 36 60 29 220 79 110 44 190 18 21.5 25.5 25.5 31 31 31 240 190 39 50 50 94 94 39 39 39 39 50 50 66 66 94 94 94 94 94 240 145 1`008 1`108 845 948 948 1`026 1`026 1`026 1`936 1`008 914 975 975 947 947 914 914 914 914 975 975 1`066 1`066 947 947 947 947 947 1`936 1`315 15500 130 185 270 270 390 390 390 25000 15500 630 1050 1050 3800 3800 630 630 630 630 1050 1050 1900 1900 3800 3800 3800 3800 3800 25000 9200 V23054D13B110 V23054D15B112 V23054D16C110 V23054D17B110 V23054D17B110 V23054D19B110 V23054D19C110 V23054D19C410 V23054D2003B110 V23054D2013B110 V23054D2020B110 V23054D2021B110 V23054D2021B112 V23054D2026B110 V23054D2026B112 V23054D20B110 V23054D20B112 V23054D20C110 V23054D20C410 V23054D21B110 V23054D21C112 V23054D22B110 V23054D22C110 V23054D26B110 V23054D26B112 V23054D26C110 V23054D26C112 V23054D26C114 V23054D3B110 V23054D4C110 4-1419172-5 6-1422019-5 4-1393812-2 4-1393812-3 4-1393812-4 4-1393812-6 4-1393812-7 5-1393812-0 1393813-1 1393813-2 1393813-3 1393813-4 1393813-5 1393813-6 1393813-7 5-1393812-1 5-1393812-2 5-1393812-3 3-1419137-7 5-1393812-4 5-1393812-5 5-1393812-8 5-1393812-9 6-1393812-2 6-1393812-3 6-1393812-4 6-1393812-5 6-1393812-6 3-1393812-8 3-1393812-9 V23054-DXXXX 5A, size II 220 98 110 53.5 6 2.9 8.4 4.4 12 5.8 16 8.7 20 10.5 24 13 32 17.5 45 24 60 36 220 98 110 53.5 24 13 60 36 240 145 9 13 18 25.5 31 39 50 66 94 240 145 39 94 1`936 1`315 1`091 1`008 1`108 948 1`026 914 975 1`066 947 1`936 1`315 914 947 25000 9200 33 70 130 270 390 630 1050 1900 3800 25000 9200 630 3800 V23054D1003F104 V23054D1004F104 V23054D1011F104 V23054D1012F104 V23054D1015F104 V23054D1017F104 V23054D1019F104 V23054D1020F104 V23054D1021F104 V23054D1022F104 V23054D1026F104 V23054D3003F104 V23054D3004F104 V23054D3020F104 V23054D3026F104 8-1393812-6 8-1393812-7 8-1393812-8 8-1393812-9 9-1393812-0 9-1393812-1 9-1393812-2 9-1393812-3 9-1393812-4 9-1393812-5 9-1393812-8 1393813-9 1-1393813-1 1-1393813-4 1-1393813-6 Vdc Further coil versions are available on request. All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data (values at 23 C) Nominal voltage Unom Operate/set voltage range Ordering Information Coil power Coil Resistance / 15 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc mW V23054-EXXXX standard, size III 8.4 4.4 12 5.8 12 8.8 12.5 6.9 12.5 10 16 8.7 16 13 20 10.5 20 15.5 20 15.5 110 53.5 125 73 60 36 24 13 24 13 24 13 24 20 24 20 32 17.5 45 24 45 24 45 35 60 36 60 55 60 43 13 18 18 21.5 21.5 25.5 25.5 31 31 31 145 190 94 39 39 39 39 39 50 66 66 66 94 94 94 1`008 1`108 1`108 845 845 948 948 1`026 1`026 1`026 1`315 1`008 947 914 914 914 914 914 975 1`066 1`066 1`066 947 947 947 70 130 130 185 185 270 270 390 390 390 9200 15500 3800 630 630 630 630 630 1050 1900 1900 1900 3800 3800 3800 V23054E12B133 V23054E15B133 V23054E15C133 V23054E16B133 V23054E16C133 V23054E17B133 V23054E17C133 V23054E19B133 V23054E19C133 V23054E19C433 V23054E2004B133 V23054E2013B133 V23054E2026B133 V23054E20B133 V23054E20B533 V23054E20B633 V23054E20C133 V23054E20C433 V23054E21B133 V23054E22B133 V23054E22B633 V23054E22C133 V23054E26B133 V23054E26C133 V23054E26C148 2-1393813-5 2-1393813-6 2-1393813-7 2-1393813-8 3-1393813-0 3-1393813-1 3-1393813-2 3-1393813-3 3-1393813-4 3-1393813-5 9-1393813-0 1422019-2 9-1393813-4 3-1393813-6 3-1393813-9 4-1393813-0 4-1393813-1 4-1393813-2 4-1393813-3 4-1393813-4 4-1393813-5 4-1393813-6 4-1393813-8 4-1393813-9 5-1393813-2 V23054-EXXXX 5A, size III 220 118 110 66 6 3.5 8.4 5.3 12 7 12.5 8.1 16 10.5 20 13 24 15.5 32 21 45 29 60 43 24 15.5 240 145 9 13 18 21.5 25.5 31 39 50 66 94 39 1`936 1`315 1`091 1`008 1`108 845 948 1`026 914 975 1`066 947 914 25000 9200 33 70 130 185 270 390 630 1050 1900 3800 630 V23054E1003F110 V23054E1004F110 V23054E1011F110 V23054E1012F110 V23054E1015F110 V23054E1016F110 V23054E1017F110 V23054E1019F110 V23054E1020F110 V23054E1021F110 V23054E1022F110 V23054E1026F110 V23054E3020F110 5-1393813-9 6-1393813-0 6-1393813-1 6-1393813-2 6-1393813-3 6-1393813-6 6-1393813-8 7-1393813-2 7-1393813-6 8-1393813-1 8-1393813-2 8-1393813-5 1-1393814-0 V23062-AXXXX standard, size I 76 32 28 15 29 13 110 40 43 996 980 945 5800 800 890 V23062A14C404 V23062A25C104 V23062A46C104 1393815-1 1393815-2 1393815-3 V23062-BXXXX standard, size II 20 13 24 15.5 45 29 60 29 31 39 66 94 1`026 914 1`066 947 390 630 1900 3800 V23062B19C410 V23062B20C110 V23062B22C110 V23062B26B610 1393815-4 1393815-5 1393815-7 1393815-8 145 94 1`315 947 9200 3800 V23062B1004F104 V23062B1026F104 1-1393815-1 1-1393815-7 Vdc V23062-BXXXX 5A, size II 110 53.5 60 36 Further coil versions are available on request. All specifications subject to change. Consult Tyco Electronics for latest specifications. 11 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Instructions for Impulse Operation The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows: UII Impuls = UII tamb = q = UII tamb . q Maximum continuous voltage at ambient temperature t amb Factor The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or not to exceed the max. voltage as listed in the table (page 6) by no more than 2.3 told. Ift ED 3 s then q Ift ED t2 If tED = = > = Pulse width Cycle time 3 s the value of q must be obtained from the nomograph (next page). Examples of various periodic pulse trains (energizing side) 1. Periodic recurrence of one energizing pulse 2. Periodic recurrence of two unequal energizing pulses tED tI + tII = = tI + tII Pulse widths within one cycle All specifications subject to change. Consult Tyco Electronics for latest specifications. 12 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Contact Data B104/B110/ B112/B133 Ordering code block 3 B604/B610/ C104/C110/ C404/C410 B612/B633 C112/C133 C412/C433 max. 6 changeover contacts or 6 make contacts Number of contacts and Type Contact assembly single contacts silver, gold F gold-flashed 150 Vdc 36 Vdc Contact material Max. switching voltage Max. switching current Max. switching capacity F104/F105 F110 bifurcated contacts silver, gold F gold-flashed 150 Vdc 36 Vdc single contacts silver, gold-flashed 260 Vdc 125 Vac 30 Vac 125 Vac 30 Vac 250 Vac 2A 35 to 70 W see load limit curve below 50 VA 0.2 A 2A 35 to 70 W see load limit curve below 50 VA 0.2 A 5A 50 to 140 W see load limit curve below 500 VA 5W 5 VA Max. continuous current at max. ambient temperature 5W 5 VA 2A 5A Max. DC Load Breaking Capacity for contact sets F1xx for contact sets B1xx and C1 xx 250 V_ 150 V_ 200 120 140 W U U 70 W 150 100 100 W 100 80 80 60 60 50 50 40 50 W 40 30 40 W 30 0,3 0,4 0,5 0,6 0,8 1 1,5 I 2A 20 0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 I 4 5A Safe breaking, no stationary arc Contact material silver, gold-flashed I U = switching current = switching voltage All specifications subject to change. Consult Tyco Electronics for latest specifications. 13 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Contact sets Size I Number of contacts and type 2 changeover contacts 2 make contacts Symbols with base conncections coil I 3 - coil II + 2 4 - + 1 Contacts in release condition, coil polarity to set the relay Contact assembly Contact material silver, gold-flashed Ordering code block 3 Contact material gold F Ordering code block 3 single contacts bifurcated contacts single contacts B104 C104 F105 B604 C404 Size II Number of contacts and type 6 make contacts 4 changover contacts 2 changover contacts Symbols with base conncections coil I 3 - coil II + 2 4 - + 1 Contacts in release condition, coil polarity to set the relay Contact assembly Contact material silver, gold-flashed Ordering code block 3 Contact material gold F Ordering code block 3 single contacts bifurcated contacts single contacts bifurcated contacts single contacts B112 C112 B110 C110 F104 B612 C412 B610 C410 All specifications subject to change. Consult Tyco Electronics for latest specifications. 14 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Contact sets Size III Number of contacts and type 6 changeover contacts 4 changeover contacts Symbols with base conncections coil I 3 - coil II + 2 4 - + 1 Contacts in release condition, coil polarity to set the relay Contact assembly Contact material silver, gold-flashed Ordering code block 3 Contact material gold F Ordering code block 3 single contacts bifurcated contacts single contacts B133 C133 F110 B633 C433 All specifications subject to change. Consult Tyco Electronics for latest specifications. 15 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Insulation Ordering code block 3 Test voltage (1 min) winding / frame contact / contact contact / frame B1xx B6xx C1xx C4xx 500 Vacrms 500 Vacrms 500 Vacrms F1xx 500 Vacrms 1000 Vacrms 1000 Vacrms General Data Ordering code block 3 Operate time at Unom and 20 C, typical Reset time typical B1xx B6xx C1xx 16 ms 2 ms Maximum switching rate without load 50 operations/s Ambient temperature range acc. to EN 61810-1 / IEC 61810-1 and VDE 0435 part 201 -40 C ... +70 C Thermal resistance 40 K/W Maximum temperature 100 C Continuous thermal load 2.1 W Degree of protection acc. to EN 60529 / IEC 60529 / VDE 0470 part 1 C4xx F1xx 10 operations/s dust-protected IP 30 or hermetically sealed IP 67 Mechanical endurance Mounting position approx.108 operations approx. 107 operations any Weight V23054 Size I Size II Size III approx. 20 g approx. 25 g approx. 27 g V23062 Size I Size II approx. 30 g approx. 35 g All specifications subject to change. Consult Tyco Electronics for latest specifications. 16 of 18 AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 IM Relays D2n Relays 4th generation slim line - low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The IM relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height. 2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x10 mm board space and 11 mm height. P2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The P2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. FX2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FX2 relay is tested according CECC/ IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height. FT2 / FU2 Relays P1 Relays Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version. W11 Relays Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height. Reed Relays High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version. Cradle Relays 3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FT2/FU2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height. FP2 Relays Other Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP2 Relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV - 10 / 160 s). The FP2 is tested according CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height. We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional. MT2 2nd generation non polarized, non latching 2 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x 10 mm board space and 11 mm height. High Frequency Relays HF3 / HF3S / HF6 series RF relays offering excellent RF characteristics in a small package. All HF series relays are suitable for SMD soldering processes. Available as non latching or latching versions with 1 or 2 coils and a nominal coil voltage range from 3 ... 24 V, a coil power consumption of 140 mW or 70 mW (single coil latching types). HF3: Low cost RF relay suitable up to 3 GHz. Impedance 50 and 75 Ohm. 50 W hot switching and 50 W RF power carry capability. Dimensions 14.6 x 7.3 x 10.3 mm. HF3S: High performance, high power RF relay suitable up to 3 GHz, 50 W hot switching and 150 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. HF6: High performance, high power RF relay suitable up to 6 GHz, 50 W hot switching and 50 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. All specifications subject to change. Consult Tyco Electronics for latest specifications. 17 of 18 Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wadenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenskeho 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com AXICOM Telecom-, Signal and RF Relays Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752