Telecom-, Signal and RF Relays
AXICOM
Cradle Relay S V23054 / V23062
108-98014 • Nov. 07 • Rev. C • ECOC: JM10
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 2 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Index
Dimensions 4
Coil Data and operating range 6
Relay Code 7
Coil Data and Ordering Information 9
Instructions for Impulse Operation 12
Contact Data 13
Insulation / General Data 16
Disclaimer
While Tyco Electronics has made every reasonable effort
to ensure the accuracy of the information in this datasheet,
Tyco Electronics does not guarantee that it is error-free,
nor does Tyco Electronics make any other representati-
on, warranty or guarantee that the information is accurate,
correct, reliable or current. Tyco Electronics reserves the
right to make any adjustments to the information contai-
ned herein at any time without notice. Tyco Electronics
expressly disclaims all implied warranties (and all express
warranties, except as otherwise stated in this datasheet)
regarding the information contained herein, including but
not limited to any implied warranties or merchantability or
tness for a particular purpose. It is recommended that
you test any new or replacement product before incorpo-
rating into a system.
The dimensions in this datasheet are for reference purpo-
se only and are subject to change without notice. Speci-
cations are subject to change without notice.
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 3 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Hand solder and plug-in relay,
for DC operation,
non-polarized, non-latching
ROHS compliant (Directive 2002/95/EC) as per
product date code 0501.
Features
Stronger magnet system and thus wider voltage range
than cradle relay N
highly reliable
Contacts for signal loads and currents up to 5 A
AC and DC, latching and non-latching,
coils operating voltage 6 V ... 220 V
Multi purpose relay
Great variety of contact arrangements and
materials to meet specic applications
Sockets for easy and quick mounting of relays (see
data sheet Accessories)
Typical applications
Press controls with high safety requirements
(forcibly guided springs)
Trafc and railroad signalling
Motor vehicle trafc controls
Relay types
Size I or II, depending on contact set
Standard contact sets with max. 6 changeover contacts
or 6 make contacts
Single or bifurcated contacts
Hand solder terminals also for plug-in
connection with screw xing
Dust-protected with plastic cover, V23054-XXX
Hermetically sealed with metal enclosure, V23062-XXX
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 4 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Dimensions Dimensions in mm
Type V23054-Exxx Size III
Hand solder terminals, silver-plated
Also for plug-in connection and screw xing
With earth terminal
Dust-protected
Type V23054-Cxxx Size I Type V23054-Dxxx Size II
Hand solder terminals, silver-plated
Also for plug-in connection and screw xing
With earth terminal
Dust-protected
For sockets and hold-down springs see data sheet Accessories
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Dimensions Dimensions in mm
Type V23062-Axxx Size I Type V23062-Bxxx Size II
Hand solder terminals, silver-plated
Also for plug-in connection and screw xing
With earth terminal
hermeticaly sealed with metal enclosure
For sockets and hold-down springs see data sheet Accessories
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 6 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Coil Data and operating range
Nominal voltage from 6 Vdc to 220 Vdc
Typical nominal power consumption, at 20 °C 1 W
Class of the operative range
acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 2
Operating voltage (according to the coil type) max. 92% of the nominal voltage
Terminals:
Coil with 1 winding
Start 4 End 1
Coil with 2 windings (upon request)
Start 3 End 2 for winding I
Start 4 End 1 for winding II
The minimum voltage UI depends on the contact set and the ambient temperature, the maximum voltage UII
only depends on the ambient temperature.
Between minimum voltage UI tamb and operating voltage U a safety margin of approx. 20% is recommended.
UI tamb (1.2) < UI
UII tamb
UI tamb = UI · U20 °C · kI tamb
UII tamb = UIl 20 °C · kII tamb
tamb = Ambient temperature
U = Operating voltage
UI tamb = Minimum voltage at ambient temperature, tamb
UII tamb = Maximum voltage at ambient temperature, tamb
kI and kII = Factors
Note: Instructions for impulse operation
see data sheet cradle relay N
Ambient temperature tamb [°C]
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 7 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Coil number
Version see page 9
011 = 6V
015 = 12V
020 = 24V
026 = 60V Nominal voltage
004 = 110V
013 = 125V
003 = 220V
V23054
Identication of the
cradle relay S, dust protected
Relay type
C = Size I
D = Size II
E = Size III
Contact set / type of contact
see page 13/14
Ordering example:
V23054-D0020-B110
Cradle relay S, size II, standard version, coil 24 Vdc, 4 changeover contact set, single contacts,
contact material silver, gold-ashed
Note:
The ordering scheme enables a multitude of variations. However, not all variations are dened as construction
specications (ordering code) and thus in the current delivery program.
Special design can be carried out to customer specications. Please contact your local representative.
Relay Code
0 = standard version
1 = tted with contact sets F (block 3)
2 = for higher test voltage
3 = contact sets F and higher test voltage winding / frame
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 8 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Coil number
Version see page 11
011 = 6V
015 = 12V
020 = 24V
026 = 60V Nominal voltage
004 = 110V
013 = 125V
003 = 220V
V23062
Identication of the
cradle relay S, hermetically sealed
Relay type
A = Size I
B = Size II
Contact set / type of contact
see page 13/14
Ordering example:
V23062-B0020-C110
Cradle relay S, size II, standard version, coil 24 Vdc, 4 changeover contact set, bifurcated contacts,
contact material silver, gold-ashed
Note:
The ordering scheme enables a multitude of variations. However, not all variations are dened as construction
specications (ordering code) and thus in the current delivery program.
Special design can be carried out to customer specications. Please contact your local representative.
Relay Code
0 = standard version
1 = tted with contact sets F (block 3)
2 = for higher test voltage
3 = contact sets F and higher test voltage winding / frame
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 9 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Coil Data (values at 23 °C) Ordering Information
Nominal
voltage
Unom
Operate/set voltage range Coil
power
Coil
Resistance
Relay
code
Tyco part
number
Minimum
voltage Umin
Maximum
voltage Umax
Vdc Vdc Vdc mW Ω / ± 15 %
V23054-CXXXX standard, size I
125 59 190 1‘008 15500 V23054C13B104 2-1419172-8
12 4.7 18 1‘108 130 V23054C15B104 1393812-6
12.5 5.4 21.5 845 185 V23054C16B104 1393812-7
20 10.5 31 1‘026 390 V23054C19C104 1422019-3
220 98 240 1‘936 25000 V23054C2003C404 3-1393812-2
110 44 145 1‘315 9200 V23054C2004B104 3-1393812-3
125 59 190 1‘008 15500 V23054C2013B104 3-1393812-4
24 10.5 39 914 630 V23054C2020B104 3-1393812-5
60 36 94 947 3800 V23054C2026C104 3-1393812-6
24 10.5 39 914 630 V23054C20B104 1-1393812-0
24 13 39 914 630 V23054C20C104 1-1393812-1
32 14.5 50 975 1050 V23054C21B104 1-1393812-2
32 17.5 50 975 1050 V23054C21C104 1-1393812-3
32 17.5 50 975 1050 V23054C21C404 1-1393812-4
45 19 66 1‘066 1900 V23054C22B104 1-1393812-5
45 24 66 1‘066 1900 V23054C22C104 1-1393812-6
60 29 94 947 3800 V23054C26B104 2-1393812-0
60 36 94 947 3800 V23054C26C104 2-1393812-3
60 36 94 947 3800 V23054C26C404 2-1393812-4
220 79 240 1‘936 25000 V23054C3B104 1393812-2
220 98 240 1‘936 25000 V23054C3C104 1393812-3
110 44 145 1‘315 9200 V23054C4B104 1393812-4
110 53.5 145 1‘315 9200 V23054C4C104 1393812-5
V23054-CXXXX 5A, size I
32 14.5 50 975 1050 V23054C1021F106 3-1393812-0
45 19 66 1‘066 1900 V23054C1022F105 3-1393812-1
12 4.7 18 1‘108 130 V23054C3015F105 1422019-5
32 14.5 50 975 1050 V23054C3021F106 3-1393812-7
Further coil versions are available on request.
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 10 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
V23054-DXXXX standard, size II
125 59 190 1‘008 15500 V23054D13B110 4-1419172-5
12 4.7 18 1‘108 130 V23054D15B112 6-1422019-5
12.5 5.4 21.5 845 185 V23054D16C110 4-1393812-2
16 7 25.5 948 270 V23054D17B110 4-1393812-3
16 7 25.5 948 270 V23054D17B110 4-1393812-4
20 10.5 31 1‘026 390 V23054D19B110 4-1393812-6
20 10.5 31 1‘026 390 V23054D19C110 4-1393812-7
20 10.5 31 1‘026 390 V23054D19C410 5-1393812-0
220 79 240 1‘936 25000 V23054D2003B110 1393813-1
125 59 190 1‘008 15500 V23054D2013B110 1393813-2
24 10.5 39 914 630 V23054D2020B110 1393813-3
32 14.5 50 975 1050 V23054D2021B110 1393813-4
32 14.5 50 975 1050 V23054D2021B112 1393813-5
60 29 94 947 3800 V23054D2026B110 1393813-6
60 29 94 947 3800 V23054D2026B112 1393813-7
24 10.5 39 914 630 V23054D20B110 5-1393812-1
24 10.5 39 914 630 V23054D20B112 5-1393812-2
24 13 39 914 630 V23054D20C110 5-1393812-3
24 13 39 914 630 V23054D20C410 3-1419137-7
32 14.5 50 975 1050 V23054D21B110 5-1393812-4
32 17.5 50 975 1050 V23054D21C112 5-1393812-5
45 19 66 1‘066 1900 V23054D22B110 5-1393812-8
45 24 66 1‘066 1900 V23054D22C110 5-1393812-9
60 29 94 947 3800 V23054D26B110 6-1393812-2
60 29 94 947 3800 V23054D26B112 6-1393812-3
60 43 94 947 3800 V23054D26C110 6-1393812-4
60 36 94 947 3800 V23054D26C112 6-1393812-5
60 29 94 947 3800 V23054D26C114 6-1393812-6
220 79 240 1‘936 25000 V23054D3B110 3-1393812-8
110 44 145 1‘315 9200 V23054D4C110 3-1393812-9
V23054-DXXXX 5A, size II
220 98 240 1‘936 25000 V23054D1003F104 8-1393812-6
110 53.5 145 1‘315 9200 V23054D1004F104 8-1393812-7
6 2.9 9 1‘091 33 V23054D1011F104 8-1393812-8
8.4 4.4 13 1‘008 70 V23054D1012F104 8-1393812-9
12 5.8 18 1‘108 130 V23054D1015F104 9-1393812-0
16 8.7 25.5 948 270 V23054D1017F104 9-1393812-1
20 10.5 31 1‘026 390 V23054D1019F104 9-1393812-2
24 13 39 914 630 V23054D1020F104 9-1393812-3
32 17.5 50 975 1050 V23054D1021F104 9-1393812-4
45 24 66 1‘066 1900 V23054D1022F104 9-1393812-5
60 36 94 947 3800 V23054D1026F104 9-1393812-8
220 98 240 1‘936 25000 V23054D3003F104 1393813-9
110 53.5 145 1‘315 9200 V23054D3004F104 1-1393813-1
24 13 39 914 630 V23054D3020F104 1-1393813-4
60 36 94 947 3800 V23054D3026F104 1-1393813-6
Coil Data (values at 23 °C) Ordering Information
Nominal
voltage
Unom
Operate/set voltage range Coil
power
Coil
Resistance
Relay
code
Tyco part
number
Minimum
voltage Umin
Maximum
voltage Umax
Vdc Vdc Vdc mW Ω / ± 15 %
Further coil versions are available on request.
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 11 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
V23054-EXXXX standard, size III
8.4 4.4 13 1‘008 70 V23054E12B133 2-1393813-5
12 5.8 18 1‘108 130 V23054E15B133 2-1393813-6
12 8.8 18 1‘108 130 V23054E15C133 2-1393813-7
12.5 6.9 21.5 845 185 V23054E16B133 2-1393813-8
12.5 10 21.5 845 185 V23054E16C133 3-1393813-0
16 8.7 25.5 948 270 V23054E17B133 3-1393813-1
16 13 25.5 948 270 V23054E17C133 3-1393813-2
20 10.5 31 1‘026 390 V23054E19B133 3-1393813-3
20 15.5 31 1‘026 390 V23054E19C133 3-1393813-4
20 15.5 31 1‘026 390 V23054E19C433 3-1393813-5
110 53.5 145 1‘315 9200 V23054E2004B133 9-1393813-0
125 73 190 1‘008 15500 V23054E2013B133 1422019-2
60 36 94 947 3800 V23054E2026B133 9-1393813-4
24 13 39 914 630 V23054E20B133 3-1393813-6
24 13 39 914 630 V23054E20B533 3-1393813-9
24 13 39 914 630 V23054E20B633 4-1393813-0
24 20 39 914 630 V23054E20C133 4-1393813-1
24 20 39 914 630 V23054E20C433 4-1393813-2
32 17.5 50 975 1050 V23054E21B133 4-1393813-3
45 24 66 1‘066 1900 V23054E22B133 4-1393813-4
45 24 66 1‘066 1900 V23054E22B633 4-1393813-5
45 35 66 1‘066 1900 V23054E22C133 4-1393813-6
60 36 94 947 3800 V23054E26B133 4-1393813-8
60 55 94 947 3800 V23054E26C133 4-1393813-9
60 43 94 947 3800 V23054E26C148 5-1393813-2
V23054-EXXXX 5A, size III
220 118 240 1‘936 25000 V23054E1003F110 5-1393813-9
110 66 145 1‘315 9200 V23054E1004F110 6-1393813-0
6 3.5 9 1‘091 33 V23054E1011F110 6-1393813-1
8.4 5.3 13 1‘008 70 V23054E1012F110 6-1393813-2
12 718 1‘108 130 V23054E1015F110 6-1393813-3
12.5 8.1 21.5 845 185 V23054E1016F110 6-1393813-6
16 10.5 25.5 948 270 V23054E1017F110 6-1393813-8
20 13 31 1‘026 390 V23054E1019F110 7-1393813-2
24 15.5 39 914 630 V23054E1020F110 7-1393813-6
32 21 50 975 1050 V23054E1021F110 8-1393813-1
45 29 66 1‘066 1900 V23054E1022F110 8-1393813-2
60 43 94 947 3800 V23054E1026F110 8-1393813-5
24 15.5 39 914 630 V23054E3020F110 1-1393814-0
V23062-AXXXX standard, size I
76 32 110 996 5800 V23062A14C404 1393815-1
28 15 40 980 800 V23062A25C104 1393815-2
29 13 43 945 890 V23062A46C104 1393815-3
V23062-BXXXX standard, size II
20 13 31 1‘026 390 V23062B19C410 1393815-4
24 15.5 39 914 630 V23062B20C110 1393815-5
45 29 66 1‘066 1900 V23062B22C110 1393815-7
60 29 94 947 3800 V23062B26B610 1393815-8
V23062-BXXXX 5A, size II
110 53.5 145 1‘315 9200 V23062B1004F104 1-1393815-1
60 36 94 947 3800 V23062B1026F104 1-1393815-7
Coil Data (values at 23 °C) Ordering Information
Nominal
voltage
Unom
Operate/set voltage range Coil
power
Coil
Resistance
Relay
code
Tyco part
number
Minimum
voltage Umin
Maximum
voltage Umax
Vdc Vdc Vdc mW Ω / ± 15 %
Further coil versions are available on request.
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 12 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Instructions for Impulse Operation
The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows:
UII Impuls = UII tamb . q
UII tamb = Maximum continuous voltage at ambient temperature t amb
q = Factor
The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or not to exceed the
max. voltage as listed in the table (page 6) by no more than 2.3 told.
Ift ED
3 s then q =
Ift ED = Pulse width
t2 = Cycle time
If tED > 3 s the value of q must be obtained from the nomograph (next page).
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
tED = tI + tII
tI + tII = Pulse widths within one cycle
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 13 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Contact Data
Ordering code block 3 B104/B110/
B112/B133
B604/B610/
B612/B633
C104/C110/
C112/C133
C404/C410
C412/C433
F104/F105
F110
Number of contacts and Type max. 6 changeover contacts or 6 make contacts
Contact assembly single contacts bifurcated contacts single contacts
Contact material silver,
gold-ashed gold F silver,
gold-ashed gold F silver,
gold-ashed
Max. switching voltage 150 Vdc 36 Vdc 150 Vdc 36 Vdc 260 Vdc
125 Vac 30 Vac 125 Vac 30 Vac 250 Vac
Max. switching current 2 A 0.2 A 2 A 0.2 A 5 A
Max. switching capacity
35 to 70 W
see load limit
curve below
50 VA
5 W
5 VA
35 to 70 W
see load limit
curve below
50 VA
5 W
5 VA
50 to 140 W
see load limit
curve below
500 VA
Max. continuous current at
max. ambient temperature 2 A 5 A
70 W
40 W
150
120
100
80
60
50
40
30
V_
U
0,3 0,4 0,5 0,6 0,8 1 1,5 2A
I
250
200
150
100
80
60
50
40
30
20
V_
100 W
140 W
50 W
0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 4 5A
I
U
Max. DC Load Breaking Capacity
Safe breaking, no stationary arc
Contact material silver, gold-ashed
for contact sets F1xx
I = switching current
U = switching voltage
for contact sets B1xx and C1 xx
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 14 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Contact sets
Size I
Number of contacts and type 2 changeover contacts 2 make contacts
Symbols with base conncections
3 2 4 1
- + - +
coil I coil II
Contacts in release condition,
coil polarity to set the relay
Contact assembly single
contacts
bifurcated
contacts single contacts
Contact material silver, gold-ashed
Ordering code block 3 B104 C104 F105
Contact material gold F
Ordering code block 3 B604 C404
Size II
Number of contacts and type 6 make contacts 4 changover contacts 2 changover
contacts
Symbols with base conncections
3 2 4 1
- + - +
coil I coil II
Contacts in release condition,
coil polarity to set the relay
Contact assembly single
contacts
bifurcated
contacts
single
contacts
bifurcated
contacts
single
contacts
Contact material silver, gold-ashed
Ordering code block 3 B112 C112 B110 C110 F104
Contact material gold F
Ordering code block 3 B612 C412 B610 C410
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 15 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Size III
Number of contacts and type 6 changeover contacts 4 changeover contacts
Symbols with base conncections
3 2 4 1
- + - +
coil I coil II
Contacts in release condition,
coil polarity to set the relay
Contact assembly single
contacts
bifurcated
contacts single contacts
Contact material silver, gold-ashed
Ordering code block 3 B133 C133 F110
Contact material gold F
Ordering code block 3 B633 C433
Contact sets
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 16 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Insulation
General Data
Ordering code block 3 B1xx B6xx C1xx C4xx F1xx
Test voltage (1 min)
winding / frame
contact / contact
contact / frame
500 Vacrms
500 Vacrms
500 Vacrms
500 Vacrms
1000 Vacrms
1000 Vacrms
Ordering code block 3 B1xx B6xx C1xx C4xx F1xx
Operate time at Unom and 20 °C, typical 16 ms
Reset time typical 2 ms
Maximum switching rate without load 50 operations/s 10
operations/s
Ambient temperature range
acc. to EN 61810-1 / IEC 61810-1 and
VDE 0435 part 201
-40 °C ... +70 °C
Thermal resistance 40 K/W
Maximum temperature 100 °C
Continuous thermal load 2.1 W
Degree of protection acc. to EN 60529 /
IEC 60529 / VDE 0470 part 1 dust-protected IP 30 or hermetically sealed IP 67
Mechanical endurance approx.108
operations
approx. 107
operations
Mounting position any
Weight
V23054
Size I
Size II
Size III
V23062
Size I
Size II
approx. 20 g
approx. 25 g
approx. 27 g
approx. 30 g
approx. 35 g
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 17 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
IM Relays
4th generation slim line – low prole polarized 2 c/o telecom signal relay
with bifurcated contacts, available as non latching or latching relay with
1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ...
200 mW, latching relays with 1 coil 100 mW. The IM relay is available as
through hole and surface mount type (J-Legs and Gull Wings) and capable
to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G
relay on the market. Dielectric strength fullls the Telcordia requirements
according GR 1089 (2,5 kV 2 / 10 µs) and FCC part 68 (1,5 kV 10 / 160 µs).
The IM relay is tested according CECC/IECQ and certied in accordance
with IEC/EN 60950 and UL 60950.
Dimensions approx. 10 x 6 mm board space and 5.65 mm height.
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal voltage
range from 3 ... 24 V, coil power consumption 140 mW, latching relays
with 1 coil 70 mW. The P2 Relay is available as through hole or surface
mount type and capable to switch currents up to 5 A. Dielectric strength
fullls the Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 µs)
and FCC part 68 (1,5 kV – 10 / 160 µs). The P2 relay is tested according
CECC/IECQ and certied in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
FX2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 coil. Nominal voltage
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high
sensitive version, 140... 300 mW for the standard version, latching relays
with 1 coil 100 mW. The FX2 relay is available as through hole type and
capable to switch loads up to 60 W/62,5 VA. Dielectric strength fullls the
Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC
part 68 (1,5 kV – 10 / 160 µs). The FX2 relay is tested according CECC/
IECQ and certied in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height.
FT2 / FU2 Relays
3rd generation non polarized, non latching 2 c/o telecom relay with bifurca-
ted contacts. Nominal voltage range from 3 ... 48 V, coil power consumption
200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and
surface mount type. Dielectric strength fullls the Telcordia requirements
according GR 1089 (2,5 kV 2 / 10 µs) and FCC part 68 (1,5 kV 10 /
160 µs). The FT2/FU2 relay is tested according CECC/IECQ and certied
in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
FP2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal voltage
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the
high sensitive version, 140... 300 mW for the standard version, latching
relays with 1 coil 100 mW.. The FP2 Relay is available as through hole
type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength
fullls FCC part 68 (1,5 kV 10 / 160 µs). The FP2 is tested according
CECC/IECQ approved.
Dimensions approx. 14 x 9 mm board space and 5 mm height.
MT2
2nd generation non polarized, non latching 2 c/o telecom and si-
gnal relay with bifurcated contacts. Nominal voltage range from 3
... 48 V, coil power consumption 150/200/300/400 and 550 mW.
Dielectric strength fulfills the requirements according FCC part 68
(1,5 kV – 10 / 160 µs).
Dimensions approx. 20 x 10 mm board space and 11 mm height.
D2n Relays
2nd generation non polarized 2 c/o relay for telecom and various other ap-
plications. Nominal voltage range from 3 ... 48 V, coil power consumption from
150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric
strength fullls the requirements according FCC part 68 (1,5 kV 10 / 160 µs).
Dimensions approx. 20 x10 mm board space and 11 mm height.
P1 Relays
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a
wide range of applications, available as non latching or latching relay with
1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption
65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as
through hole or surface mount type and capable to switch currents up to 1
A. Dielectric strength fullls the requirements according FCC part 68 (1,5
kV 10 / 160 µs). Dimensions approx. 13 x 7,6 mm board space and 7
mm height for THT or 8 mm height for SMT version.
W11 Relays
Low cost, non polarized 1 c/o relay for various applications. Nominal
voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive
versions 200 mW. The W11 relay is capable to switch currents up to 3 A.
Dielectric strength 1000 Vrms.
Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height.
Reed Relays
High sensitive, non polarized relay for telecom and various other applica-
tions, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range
from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ...
280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or
SIL housing and capable to switch currents up to 0,5 A. Integrated diode
and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimen-
sions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or
19,8 x 5 mm board space and 7,8 mm height for SIL version.
Cradle Relays
Extremely reliable and mature relay family of 1st generation for various signal
switching applications. Available as non polarized, polarized / latching and
relay with AC coil. The benet is the possibility of combining various contact
sets from 1 up to 6 poles, single and bifurcated contacts, different contact
materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are
available as dust protected and hermetically sealed versions, with plug in or
solder terminals and are capable to switch currents up to 5 A. Forcibly guided
(linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from
approx. 19 x 24 to 19x35 mm board space and 30 mm height.
Other Relays
We offer a variety of different relay families for maintenance and replace-
ment purposes. These relays are up to 60 years old now, such as Card
Relay SN (V23030 series), Small General Purpose Relay (V23006 series),
Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series).
Accessories like sockets, hold down springs, etc. optional.
High Frequency Relays
HF3 / HF3S / HF6 series RF relays offering excellent RF characteristics
in a small package. All HF series relays are suitable for SMD soldering
processes. Available as non latching or latching versions with 1 or 2 coils
and a nominal coil voltage range from 3 24 V, a coil power consumption
of 140 mW or 70 mW (single coil latching types).
HF3: Low cost RF relay suitable up to 3 GHz. Impedance 50 and 75 Ohm.
50 W hot switching and 50 W RF power carry capability.
Dimensions 14.6 x 7.3 x 10.3 mm.
HF3S: High performance, high power RF relay suitable up to 3 GHz,
50 W hot switching and 150 W RF power carry capability.
Dimensions 15 x 7.6 x 10.6 mm.
HF6: High performance, high power RF relay suitable up to 6 GHz,
50 W hot switching and 50 W RF power carry capability.
Dimensions 15 x 7.6 x 10.6 mm.
Telecom-, Signal and RF Relays
AXICOM
Tyco Electronics Logistics AG
Werk Axicom Au
Seestrasse 295
CH-8804 Au-Wädenswil / Switzerland
Phone +41 44 782 91 11
Fax +41 44 782 90 00
E-mail: axicom@tycoelectronics.com
Tyco Electronics
Paulsternstrasse 26
D-13629 Berlin / Germany
Phone +49 30 386 38573
Fax +49 30 386 38575
E-mail: axicom@tycoelectronics.com
Tyco Electronics EC Trutnov s.r.o.
Komenského 821
CZ-541 01 Trutnov / Czech Republic
E-mail: axicom@tycoelectronics.com
Tyco Electronics Corporation
POB 3608,
Harrisburg, PA 17105, USA
Phone +1 800-522-6752