Terminals (R) (R) Non-Insulated Ring Cat. No. These non-insulated ring terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is stamped on the tongue of each terminal. Most standard bulk catalog numbers can be put on Mylar Tape for reel fed applications (i.e. 12050 tool and applicaton dies). See page 57. Please put the suffix M for Mylar Tape RA2573M. (Bulk number 1000 and 500 packages.) Stock Thickness: A & B = .03 BC = .05 C = .04 Wt./Lbs. Per 1000 Pkg. Qty. Wire Range Bolt Hole A18-4 A18-6 A85 A18-8 A86 A18-10 A87 A18-14 A71 A72 A73 A18-12 A75 100 100 1000 100 1000 100 1000 100 1000 1000 1000 100 1000 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 22-16 #4 #6 #6 #8 #8 #10 #10 b" b" j" c" d" d" 2 2 2 2 2 2 2 3 3 3 3 3 3 B14-4 B132 B14-6 B133 B14-8 B86 B14-10 B87 B14-14 B71 B14-516 B72 B14-38 B73 B14-12 B75 B85 B134 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 100 1000 1000 1000 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 18-14 #4 #4 #6 #6 #8 #8 #10 #10 b" b" j" j" c" c" d" d" #6 #8 50 500 50 500 50 500 50 500 50 500 50 500 50 500 heavy duty 16-14 use C tooling heavy duty 16-14 use C tooling heavy duty 16-14 use C tooling heavy duty 16-14 use C tooling heavy duty 16-14 use C tooling heavy duty 16-14 use C tooling heavy duty 16-14 use C tooling 50 500 50 500 50 500 1000 50 500 50 500 1000 50 500 50 500 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 12-10 BC14-6 BC85 BC14-8 BC86 BC14-10 BC87 BC14-14 BC71 BC14-516 BC72 BC14-38 BC79 BC14-12 BC75 C10-6 C33 C10-8 C77 C10-10 C26 C36 C10-14 C71 C10-516 C70 C72 C10-38 C73 C10-12 C75 Dimensions A B C M .75 .72 .72 .75 .75 .75 .75 .92 .92 .92 .99 1.06 1.06 .31 .25 .25 .31 .31 .31 .31 .50 .50 .50 .54 .72 .72 .27 .27 .27 .27 .27 .27 .27 .37 .37 .37 .35 .38 .38 .59 .59 .59 .59 .59 .59 .59 .67 .67 .67 .67 .70 .70 2 2 2 2 3 3 3 3 6 6 6 6 6 6 6 6 6 6 .72 .72 .75 .75 .75 .75 .75 .75 .93 .93 .93 .93 .96 .96 1.06 1.06 .75 .72 .25 .25 .31 .31 .31 .31 .31 .31 .50 .50 .50 .50 .54 .54 .72 .72 .31 .25 .27 .27 .27 .27 .27 .27 .27 .27 .38 .38 .38 .38 .35 .35 .38 .38 .27 .27 .59 .59 .59 .59 .59 .59 .59 .59 .68 .68 .68 .68 .68 .68 .70 .70 .59 .59 #6 #6 #8 #8 #10 #10 b"" b" j" j" c" c" d" d" 4 4 4 4 5 5 5 5 6 6 6 6 6 6 .81 .81 .87 .87 .87 .87 .93 .93 1.04 1.04 1.09 1.09 1.32 1.32 .25 .25 .39 .39 .39 .39 .51 .51 .54 .54 .63 .63 .76 .76 .29 .29 .29 .29 .29 .29 .29 .29 .38 .38 .38 .38 .54 .54 .68 .68 .68 .68 .68 .68 .68 .68 .77 .77 .77 .77 .94 .94 #6 #6 #8 #8 #10 #10 #10 b" b" j" j" j" c" c" d" d" 4 4 5 5 5 5 7 7 7 8 8 7 7 7 7 7 .82 .82 .82 .82 .85 .85 .82 .91 .91 .98 .98 1.10 1.10 1.10 1.21 1.21 .31 .31 .31 .31 .38 .38 .31 .50 .50 .50 .50 .59 .59 .59 .72 .72 .27 .27 .27 .27 .27 .27 .27 .27 .27 .38 .38 .45 .45 .45 .38 .38 .66 .66 .66 .66 .66 .66 .66 .66 .66 .73 .73 .80 .80 .80 .84 .84 U.L. Listed E9809 Installing tools: WT111M, WT112M, WT110M, ERG-2002, WT2000 M C B A (c) 2000 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 13 Terminals (R) (R) Non-Insulated Ring Pkg. Qty. Wire Range Bolt Hole Wt./Lbs. Per 1000 A B C M D8-10* D36* D8-14* D71* D8-516* D72* D8-38* D73* D8-12* D75* 25 200 25 200 25 200 25 200 25 200 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 #10 #10 b" b" j" j" c" c" d" d" 16 16 14 14 16 16 14 14 14 14 1.13 1.13 1.13 1.13 1.32 1.32 1.32 1.32 1.49 1.49 .48 .48 .48 .48 .59 .59 .59 .59 .82 .82 .36 .36 .36 .36 .49 .49 .49 .49 .55 .55 .90 .90 .90 .90 1.03 1.03 1.03 1.03 1.09 1.09 D10161 D10361 D10711 D10721 D10731 D975* 200 200 200 200 200 200 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 9-8-7 #8 #10 b" j" c" d" 12 12 12 12 12 12 1.15 1.15 1.20 1.28 1.28 1.46 .41 .41 .45 .56 .56 .83 .28 .28 .36 .36 .36 .49 .95 .95 .97 1.00 1.00 1.06 E6-10* E26* E6-14* E71* E6-516* E72* E6-38* E73* E6-12* E75* 20 200 20 200 20 200 20 200 20 200 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 6-5 #10 #10 b" b" j" j" c" c" d" d" 17 17 20 20 20 20 20 20 20 20 1.13 1.13 1.13 1.13 1.32 1.32 1.32 1.32 1.49 1.49 .48 .48 .48 .48 .60 .60 .60 .60 .82 .82 .36 .36 .36 .36 .49 .49 .49 .49 .55 .55 .90 .90 .90 .90 1.03 1.03 1.03 1.03 1.08 1.08 E10261 E10711 E10721 E10731 200 200 200 200 6-5 6-5 6-5 6-5 #10 b" j" c" 14 14 14 14 1.26 1.26 1.38 1.38 .49 .49 .60 .60 .24 .27 .34 .34 1.02 .99 1.04 1.04 F4-10* F26* F4-14* F71* F4-516* F72* F4-38* F73* F4-12* F75* 20 200 20 200 20 200 20 200 20 200 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 #10 #10 b" b" j" j" c" c" d" d" 24 24 25 25 25 25 25 25 25 25 1.16 1.16 1.16 1.16 1.35 1.35 1.35 1.35 1.52 1.52 .48 .48 .48 .48 .60 .60 .60 .60 .82 .82 .36 .36 .36 .36 .49 .49 .49 .49 .55 .55 .93 .93 .93 .93 1.06 1.06 1.06 1.06 1.11 1.11 F10261 F10711 F10721 F10731 F975* 100 100 100 100 200 4-3 4-3 4-3 4-3 4-3 #10 b" j" c" d" 20 20 20 20 20 1.37 1.37 1.42 1.42 1.49 .55 .55 .62 .62 .83 .30 .30 .34 .34 .45 1.07 1.07 1.08 1.08 1.10 Cat. No. These non-insulated ring terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (recommended for solid wire). Serrated barrel increases grip on wire. Wire range identification is stamped on the tongue of each terminal. Stock Thickness: D & E = .06 F = .07 D10, E10, F10 = .04 D975 & F975 = .04 *Brazed Seam, Lolly-Pop Style Tongue Dimensions Installing tools: ERG-2005 (D Series only), WT115A D, E, F and G, TBM6/TBM6S, WT3185 Installing dies: 11802 INDENTOR (D-E-F-G), D-11803-NEST, E-11805-NEST, F-11806-NEST (all ordered separately) * Not available on Mylar Tape. M C B A 14 (c) 2000 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com Terminals (R) (R) Non-Insulated Ring Pkg. Qty. Wire Range Bolt Hole Wt./Lbs. Per 1000 A B C M G2-14 G2-516 G2-38 G2-12 10 10 10 10 2-1 2-1 2-1 2-1 b" j" c" d" 50 50 50 50 1.59 1.59 1.59 1.79 .69 .69 .69 .80 .40 .40 .40 .49 1.26 1.26 1.26 1.36 H10-14 J20-38 K30-38 L40-38 M250-38 10 10 5 5 5 1/0 2/0 3/0 4/0 250MCM b" c" c" c" c" 50 70 82 100 135 1.65 1.84 2.08 2.25 2.40 .77 .83 .93 1.04 1.12 .43 .46 .54 .57 .65 1.32 1.46 1.69 1.77 1.91 G926 G971 G972 G973 G975 100 100 100 100 100 1-2 1-2 1-2 1-2 1-2 #10 b" j" c" d" 40 40 40 40 40 1.59 1.59 1.59 1.59 1.79 .69 .69 .69 .69 .80 .40 .40 .40 .40 .49 1.26 1.26 1.26 1.26 1.36 H971 H972 H973 H975 100 100 100 100 1AN-1/0 1AN-1/0 1AN-1/0 1AN-1/0 b" j" c" d" 50 50 50 50 1.65 1.65 1.65 1.85 .77 .77 .77 .77 .43 .43 .43 .54 1.32 1.32 1.32 1.41 J971 J972 J973 J974 J975 100 100 100 100 100 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 1/0AN-2/0 b" j" c" k" d" 60 60 60 60 60 1.94 1.94 1.99 1.99 1.99 .84 .84 .84 .89 .89 .48 .48 .53 .51 .51 1.53 1.53 1.58 1.56 1.56 K971 K972 K973 K974 K975 100 100 100 100 100 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 2/0AN-3/0 b" j" c" k" d" 76 76 76 76 76 2.08 2.08 2.08 2.08 2.08 .93 .93 .93 .93 .93 .54 .54 .54 .54 .54 1.69 1.69 1.69 1.70 1.70 L973 L974 L975 100 100 100 3/0AN-4/0 3/0AN-4/0 3/0AN-4/0 c" k" d" 92 92 92 2.25 2.25 2.25 1.04 1.04 1.04 .57 .57 .57 1.77 1.77 1.77 M972 M973 M974 M975 100 100 100 100 4/0AN-250MCM 4/0AN-250MCM 4/0AN-250MCM 4/0AN-250MCM j" c" k" d" 112 112 112 112 2.28 2.40 2.40 2.40 1.12 1.12 1.12 1.12 .62 .65 .65 .65 1.90 1.91 1.91 1.91 Cat. No. These non-insulated ring terminals are made of electrolytic copper for high conductivity. They can be installed with crimping tools having a single indentor or double indentor (re commended for solid wire). Serrated barrel increases grip on wire. Wire range identification is stamped on the tongue of each terminal. Stock Thickness: G & H = .05 J & K = .06 L & M = .07 Dimensions AN - Aircraft Wire Installing tools: TBM6/TBM6S, WT3185 (G, H, J Series only) Note: Not available on Mylar Tape. M C B A (c) 2000 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 15