Standard Unshrouded Header Plug XG8 1
Standard Unshrouded Header Plug
XG8
Standard Plugs can be used in a wide
range of applications.
The XG8 2 row plugs mates with different Omron 2 row Sockets:
XG4M Flat Cable Connector, XG4H Board to Board Connector
and XG5 Discrete-wire IDC Connector
XG8A and XG8B Header / Plugs are sold in strips of 50 (single row)
or 100 (double row) terminals. Simply cut the strips to the desired
length / number of contacts.
XG5Z-0002 Top Lock Levers (sold separately) ensure secure connec-
tion to Omron Sockets when used with double row, right-angle XG8W.
RoHS Compliant
Unshrouded Plugs
Original Header / Plug
Header / Plug Strips
Note: 1. See the following pages for exact part numbers
Ratings and Characteristics
Note: 1. The rated current will depend on the Socket you are using.
It is 1A if using the XG4M and 3A if using XG5, for example.
2. The contact resistance is measured with the Plug mated to
an XG5M-N.
Materials and Finish
Note: Two types of contacts and mating ends, one with gold plating and
the other with tin plating, are available. (XG8V and XG8W)
Applicable Sockets
Model XG8V XG8W
Single Row Double Row
Straight Right-angle Straight Right-angle
Appearance
Model XG8A XG8B
Single Row Double Row
Straight Right-angle Straight Right-angle
Appearance
Rated current 3 A (See note 1.)
Rated voltage 300 VAC
Contact
resistance
20 mΩmax. (at 20 mV, 100 mA max.) (See note 2.)
Insulation
resistance
1,000 MΩmin. (at 500 VDC)
Dielectric
strength
650 VAC for 1 min. (leakage current: 1 mA max.)
Ambient
temperature
Operating: 55°Cto105°C (with no icing)
Model XG8V and XG8W XG8A and XG8B
Base
Fiber-glass reinforced PBT resin (UL94V-0)/black
Contacts
Mating end
1) Brass/nickel base,
0.15-μm gold plating
2) Brass/nickel base,
2.0-μm tin plating
Brass/nickel base,
0.15-μm gold plating
Terminal Brass/nickel base,
2.0-μm tin plating
XG8W and XG8B
(Double Row)
XG4M Flat Cable Connectors (Sockets)
XG4H Board-to-Board Connectors (Sockets)
XG5M-N Discrete-wire IDC Connectors
(Double-row Sockets)
XG5N Discrete-wre IDC Sockets
2Standard Unshrouded Header Plug XG8
XG8V Single-row Header Plugs
Dimensions
Ordering Information
0.635 0.635
Mounting holes (bottom view)
0.8 +0.1 dia.
0
XG8V-@@31
(With gold-plated straight terminals)
XG8V-@@41
(With tin-plated straight terminals)
No. of
contacts
Dimensions (mm)
AB
2 5.1 2.54
3 7.6 5.08
4 10.2 7.62
5 12.7 10.16
6 15.2 12.70
7 17.8 15.24
8 20.3 17.78
10 25.4 22.86
12 30.5 27.94
13 33.0 30.48
15 38.1 35.56
16 40.6 38.10
17 43.2 40.64
20 50.8 48.26
36 91.4 88.90
0.635 0.635
Mounting holes (bottom view)
0.8 +0.1 dia.
0
4 to 11
XG8V-@@34
(With gold-plated right-angle terminals)
XG8V-@@44
(With tin-plated right-angle terminals)
No. of
contacts
Dimensions (mm)
AB
2 5.1 2.54
3 7.6 5.08
4 10.2 7.62
5 12.7 10.16
6 15.2 12.70
7 17.8 15.24
8 20.3 17.78
10 25.4 22.86
12 30.5 27.94
13 33.0 30.48
15 38.1 35.56
16 40.6 38.10
17 43.2 40.64
20 50.8 48.26
36 91.4 88.90
Appearance Plugs with straight terminals Plugs with right-angle terminals
No. of contacts Model (gold plated) Model (tin plated) Model (gold plated) Model (tin plated)
2XG8V-0231 --- --- XG8V-0244
3XG8V-0331 XG8V-0341 XG8V-0334 XG8V-0344
4XG8V-0431 XG8V-0441 XG8V-0434 XG8V-0444
5XG8V-0531 XG8V-0541 XG8V-0534 XG8V-0544
6XG8V-0631 XG8V-0641 XG8V-0634 XG8V-0644
7XG8V-0731 XG8V-0741 XG8V-0734 XG8V-0744
8XG8V-0831 XG8V-0841 XG8V-0834 XG8V-0844
10 XG8V-1031 XG8V-1041 XG8V-1034 XG8V-1044
12 XG8V-1231 XG8V-1241 XG8V-1234 XG8V-1244
13 XG8V-1331 --- XG8V-1334 ---
15 XG8V-1531 --- XG8V-1534 ---
16 XG8V-1631 XG8V-1641 XG8V-1634 XG8V-1644
17 XG8V-1731 --- XG8V-1734 ---
20 XG8V-2031 XG8V-2041 XG8V-2034 XG8V-2044
36 XG8V-3631 XG8V-3641 XG8V-3634 XG8V-3644
Standard Unshrouded Header Plug XG8 3
XG8W Double Row Plugs for MIL Connectors
Dimensions
Ordering Information
0.635 × 0.635
Mounting holes (bottom view)
0.8 +0.1 dia.
0
XG8W-@@31
(With gold-plated straight terminals)
XG8W-@@41
(With tin plated straight terminals)
Dimensions
No. of
contacts
Dimensions (mm)
AB
10 12.7 10.16
14 17.8 15.24
16 20.3 17.78
20 25.4 22.86
26 33.0 30.48
30 38.1 35.56
34 43.2 40.46
40 50.8 48.26
50 63.5 60.96
60 76.2 73.66
0.635 × 0.635
Mounting holes (bottom view)
0.8 +0.1 dia.
0
4 to 11
XG8W-@@34
(With gold-plated right-angle terminals)
XG8W-@@44
(With tin-plated right-angle terminals)
Dimensions
No. of
contacts
Dimensions (mm)
AB
20 25.4 22.86
26 33.0 30.48
30 38.1 35.56
34 43.2 40.64
40 50.8 48.26
50 63.5 60.96
Appearance Plugs with straight terminals Plugs with right-angle terminals
No. of contacts Model (gold plated) Model (tin plated) Model (gold plated) Model (tin plated)
10 XG8W-1031 XG8W-1041 ⎯⎯
14 XG8W-1431 XG8W-1441 ⎯⎯
16 XG8W-1631 XG8W-1641 ⎯⎯
20 XG8W-2031 XG8W-2041 XG8W-2034 XG8W-2044
26 XG8W-2631 XG8W-2641 XG8W-2634 XG8W-2644
30 XG8W-3031 XG8W-3041 XG8W-3034 XG8W-3044
34 XG8W-3431 XG8W-3441 XG8W-3434 XG8W-3444
40 XG8W-4031 XG8W-4041 XG8W-4034 XG8W-4044
50 XG8W-5031 XG8W-5041 XG8W-5034 XG8W-5044
60 XG8W-6031 XG8W-6041 ⎯⎯
4Standard Unshrouded Header Plug XG8
XG8A (Single-row)/XG8B (Double-row)
Header Plug Strips for MIL Connectors
Dimensions
Single-row Plugs
Double-row Plugs
Ordering Information
Mounting holes (bottom view)
0.635 × 0.635
0.8
+0.1
dia.
0
XG8A-5031
(With straight terminals)
Mounting holes (bottom view)
0.635 × 0.635
0.8
+0.1
dia.
0
4 to 11
XG8A-5034
(With right-angle terminals)
Mounting holes (bottom view)
0.635 × 0.635
0.8 +0.1 dia.
0
XG8B-0131
(With straight terminals)
Mounting holes (bottom view)
0.635 × 0.635 0.8
+0.1
dia.
0
4 to 11
XG8B-0134
(With right-angle terminals)
Terminal type Plugs with straight terminals Plugs with right-angle terminals
No. of contacts Model (gold plated contacts) Model (gold plated contacts)
50 (Single-row) XG8A-5031 XG8A-5034
100 (Double-row) XG8B-0131 XG8B-0134
Standard Unshrouded Header Plug XG8 5
Accessories
Top Lock Levers
XG5Z-0002 - “Lock Lever”
Can be used to lock XG8W Double-row Right-angle Terminal Plugs
to XG4M Flat Cables and XG5M-N Discrete-wire IDC Connectors.
(See XG4 and XG5 Datasheets).
They cannot be used with XG8W Double-row Straight Terminal Plugs.
Note: Order the above model in multiples of 10 pieces.
Mounting the Lock Lever
Insert the tab on the Lock Lever into the hole on a Socket with a
polarity guide. In this way, it can be locked with XG8W Right-angle
Terminal Plugs.
Precautions
Correct Use
Dividing the XG8W (with Straight Terminals), XG8V,
XG8A, and XG8B
The above mentioned models may have the number of terminals and
rows reduced prior to pcb assembly, using the following method:
Using a Cutter, make a cut on the slot as indicated by the dotted
line in the diagram. Then fold the Plug manually in the direction of
the arrows.
XG8W’s with right-angle terminals are not designed to be divided in
this manner. Do not divide the XG8W with right-angle terminals.
Instead, use the XG8B Header Plug Strip with right-angle termi-
nals, if a double-row header plug with right-angle terminals must be
divided to reduce the number of terminal rows.
Automated Soldering Conditions (Jet Flow)
1. Soldering temperature: 250 ±5°C
2. Continuous soldering time: Within 5 s
Cross-sectional View of Terminal
XG8
Polarizing guide hole XG4M
Ta b
Lock lever
(1) Using a cutter,
make a cut along
the dotted line.
(2) Manually fold in
the direction of the
arrows.
0.65 dia.
XG4H
0.7 dia.
XG4A
XG4C
6Standard Unshrouded Header Plug XG8
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No.G043-E-01 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/14 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.