GORDOS SOLID STATE RELAYS G SERIES POWER RELAYS GA5 SERIES POWER RELAYS Back-to-back (dual) SCR output for severe Economical triac output for general inductive loads. purpose applications @ Superior False turn-on immunity and positive turn-off at high dv/dt. FEATURES = Current ratings to 90A = Quiput voltage rating to 660 VAC with 24 VAC minimum @ AC or DC inputs m 4KV optical isolation m Zero AC or random turn-on models m= RC snubber network for inductive loads m@ UL recognized (E46203, E79183), CSA certified (38595) m VDE approval on many models (37421) 8-32 PAN HEAD SCREW =+ 1.75 (44,5) LARGE SADDLE 0.187 (4,5) DIA LAMP 1.1 (27,9) tap (4,5) hr (S, i oe Df Pd oS N Aw _ = ~ -~ ld 5 2 = wo of TRIGGER 1 a S 3 = z N CIRCUIT r q TA 2 a a \ ' i ! } afsy el 6-32 PAN HEAD SCREW | 1.0 (25,4) BY 0.265 (6,7) R SMALL SADDLE CLAMP { G SERIES AC INPUT EQUIVALENT CIRCUIT | 0.09 (2,3) > Le 0.95 (24,1) >| nd TRIGGER |__14 CIRCUIT r=] r MAX G SERIES DC INPUT DIMENSIONS: INCHES (MILLIMETERS) EQUIVALENT CIRCUIT TOLERANCE:+0.020 (+0,50) TRIGGER TRIGGER > z of CIRCUIT CIRCUIT oc w a ZS a f 3 Zz a pw GA5 SERIES AC INPUT GAS SERIES DC INPUT EQUIVALENT CIRCUIT . EQUIVALENT CIRCUIT Products and specifications subject to change without notice. Consult factory for application assistance. 1000 N. SECOND ST., ROGERS, AR 72756 USA / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 60 GORDOS ioe) ' ie SOLID STATE RELAYS ae oS [7p] i a G, GA5 SERIES POWER RELAYS m =) G SERIES (1) MODEL NUMBER Output Control m Rating Voltage = na OUTPUT Gi20a10 | G2aoato | Gasoaio | Gasoaio | @s7vsaio | 10a | 90-280 VAC SPECIFICATIONS G120A25 | G240A25 | G280A25 | G480A25 | G575A25 25A 90-280 VAC CIFICATIO G120A45 | G240A45 | G280A45 | | | 45A | 90-280 VAC * | gasoaso | gszsaso | soa 90-280 VAC | | G280A75 | G4s0A75 | G575A75 | 75A | 90-280 VAC | G280A90 | G480A90 | G575A90 | 90A | 90-280 VAC G120D10* G240D10" | G280D10* G480D10 G575D10 10A | 3-32 VDC G120D25* | G24op25* | qG2sop25* | Gasop25 | G575De25 25A 3-32 VDC G120D45* | G2aop45* | G2sopas | | | 45a | 3-32 vbc 6) l | G480D50 | GS575D50 | SOA | 3-32 VDC G2sop75 | Gasop75 | @575D75 75A 3-32 VDC | | G2sops0 | Gasops0 | Gs575D90 | 90a | 3-32 voc Gi20E10 | G24oe10 | G2soeio | Gasoeio | asvseio |! 10a | ieaevac G120E25 | G240E25 | G2B0E25 | G480E25 | Gs75E25 | 254 | 18-36 VAC Gi20E45 | G240E45 | G280E45 | 454 | 18-36 VAC | | | Gasoeso | as7sEs0 50A 18-36 VAC | | G280E75 | G480E75 | q@s75E7=5 | 754 | 18-36 VAC | G280E90 | G480E90 | G575E90 90A | 18-36 VAC i T qT T Maximum Line Voltage (VRMS) 140 | 250 | 280 | 480 | 660 Minimum line voltage (Vrms) 24 l 24 l 24 l 36 | 48 Max. off-state voltage (Vpeak)? +250 +500 +600 +1200 +1200 Max. off-state leakage (mArms)* 7.5 | 15.0 | 15.0 | 15.0 | 20.0 Static (off-state) dv/dt (V/s)4 200 | 200 200 l 200 | 200 Specify suffix R for random turn-on models. GA5 SERIES (1) MODEL NUMBER Output Control Rating Voltage OUTPUT GA5-2A10 | GAS5-4A10 | GA5-6A10 | 10A | 90-280 VAC SPECIFICATIONS GAS5-2A25 | GAS-4A25 | GA5-GA25 | 25A | 90-280 VAC GA5-2D10* | GAs-4D10* | GA5-6D10* 10A 3-32 VDC | | GA5-2D25* | GA5-4D25* | GA5-6D25* 25A 3-32 VDC GAS-2E10 | GAS5-4E10 | GA5-6E1I0 =| ion =! 18-36 vac GAS-2E25 | GA5-4E25 | GAS5-6E25 25A | 18-36 VAC Maximum Line Voltage (VRMS) 140 | 250 | 280 Minimum line voltage (Vrms) 24 | 24 | 24 Max. off-state voltage (Vpeak) +250 +400 +600 Max. off-state leakage (mArms) 7.5 | 15.0 | 15.0 Static (off-state) dv/dt (V/s) 200 | 200 | 200 Specify suffix R for random turn-on models. Specify suffix V for VDE approved models. (120, 250, 280 D input versions only) (1) Specifications apply to TA from -30 to +80 C unless otherwise noted. (2) One minute maximum duration if applied as a DC voltage. (3) At TA of 25 C and maximum line voltage. (4) Minimum dv/dt per EIA/NARM RS443, method RS397, 25 C. (5) G480D and G575D series DC input range is 4.0 to 32.0 VDC. Products and specifications subject to change without notice. Consult factory for application assistance. 1000 N. SECOND ST., ROGERS, AR 72756 USA / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 61 GORDOS SOLID STATE RELAYS G, GA5 SERIES POWER RELAYS INPUT SPECIFICATIONS (1) Parameter A D E Control Voltage 90-280 VAC 3-32 VDC 18-36 VAC Drop Out Voltage 10 Vrms 1.0DC 2.0 Vrms Maximum Input Current (2) 10 mArms 34 mADC 7 mArms Nominal Input Resistance (3) 40K 0 KO 8K Turn-On Time (4) 20 mS 0.5 Cycle Max 20 mS Turn-Off Time 30 mS 0.5 Cycle Max 30 mS OUTPUT SPECIFICATIONS Parameter G Series GAS5 Series Units Maximum On-State Current (5) 10 25 45 50 75 90 10 25 Arms Minimum On-State Current 100 100 100 100 100 100 50 50 mArms Maximum 1-Cycle Surge (6) 100 250 500 750 750 1000 100 250 Apeak Maximum 1-Second Surge (7) 30 75 135 145 200 280 30 75 Apeak On-State Voltage Drop (8) 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 Vpeak lt (60 Hz, Half Cycle) 200 260 1040 2345 2345 4165 40 260 Asec Rjb (140, 250, 280,V Models) 1.8 1.8 0.65 = = - 0.25 0.25 3.0 2.0 C/W Rib (480, 660V Models) 0.8 0.8 - 060 025 0.25 - - C/W GENERAL SPECIFICATIONS (1) Parameter All Devices Units Operating Temperature Range -20 to +80 C Storage Temperature Range -40to+100 C Input to Output Isolation Voltage (9) 4000 Vrms Input/Output to Ground Isolation Voltage 2500 Vrms Capacitance Input to Output (Typical) 8 pF Line Frequency Range 47 to 80 Hz Notes. (1) Specifications apply to Ta -30 to +80 unless otherwise noted. (2) At maximum input voltage. (3) Does not include IRED impedance (drop). (4) At 60 Hz 100us for random turn-on (suffix R) models. (5) With relay properly mounted on an adequate heatsink. See thermal derating charts. (6) At Ta of 25 C, non-repetitive. (7) At Ta of 25 C. (8) At Ta of 25 C and maximum on-state current. (9) At TA of 25 C for one second, maximum leakage 1 MA. (10) Control voltage range for G480D and G575D series is 4.0 to 32.0 VDC. Products and specifications subject to change without notice. Consult factory for application assistance. 1000 N. SECOND ST., ROGERS, AR 72756 USA / TEL: 800-643-3500 / 501-636-5000 / FAX: 501-636-2305 62