Protection Reference 44121 44122 44123 44124 44125 44126 44127 44128 44129 44130 44131* 44132* PRIMARY VOLTAGE Secondary Secondary No-load voltage Current voltage V mA V 6 333 10,4 9 222 15,5 12 167 20,7 15 133 25,8 18 111 30,8 24 83 41,4 2x6 2 x 167 2 x 10,4 2x9 2 x 111 2 x 15,4 2 x 12 2 x 83 2 x 20,7 2 x 15 2 x 67 2 x 25,8 2 x 18 2 x 56 2 x 30,8 2 x 24 2 x 42 2 x 41,4 Ambient Temperature C T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B T 70 B Rating VA 2 2 2 2 2 2 2 2 2 2 2 2 * to be noted : 2 x 18 V and 2 x 24 non safety transformer approved, conform to EN 61558-2-6 (Isolating transformer). l l l l l l Vacuum filling Two compartments bobbins Self-extinguishing plastics UL 94 VO Degree of protection IP 00 100 grams weight Resin class B CEI 85 (20 000 h testing to CEI 126) l l l l l Inherently short-circuits proof transformer 30 V model is VDE EN 61558-2-6 certified (production on request) Insulation voltage 4 KV (6 KV MYRRA test) 100% tested production Certification : CCA procedure on request