* to be noted : 2 x 18 V and 2 x 24 non safety transformer approved,
conform to EN 61558-2-6 (Isolating transformer).
PRIMARY VOLTAGE
Protection Reference
Secondary
voltage
V
Secondary
Current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
44121 6 333 10,4 T 70 B 2
44122 9 222 15,5 T 70 B 2
44123 12 167 20,7 T 70 B 2
44124 15 133 25,8 T 70 B 2
44125 18 111 30,8 T 70 B 2
44126 24 83 41,4 T 70 B 2
44127 2 x 6 2 x 167 2 x 10,4 T 70 B 2
44128 2 x 9 2 x 111 2 x 15,4 T 70 B 2
44129 2 x 12 2 x 83 2 x 20,7 T 70 B 2
44130 2 x 15 2 x 67 2 x 25,8 T 70 B 2
44131* 2 x 18 2 x 56 2 x 30,8 T 70 B 2
44132* 2 x 24 2 x 42 2 x 41,4 T 70 B 2
lVacuum filling
lTwo compartments bobbins
lSelf-extinguishing plastics UL 94
VO
lDegree of protection IP 00
l100 grams weight
lResin class B CEI 85 (20 000 h
testing to CEI 126)
lInherently short-circuits proof
transformer
l30 V model is VDE EN 61558-2-6
certified (production on request)
lInsulation voltage 4 KV (6 KV
MYRRA test)
l100% tested production
lCertification : CCA procedure on
request