60 SRIES General purpose relays 6 - 10 A Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control systems FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 60 SERIES General purpose relays 6 - 10 A 60 SERIES 60.12 Plug-in mount 10 A General purpose relay 60.13 Type 60.12 A - 2 pole, 10 A Type 60.13 - 3 pole, 10 A * 2 & 3 pole changeover contacts * Cadmium Free contacts (preferred version) * AC coils & DC coils * UL Listing (certain relay/socket combinations) * Contact material options * Lockable test button with mechanical flag * 2 pole, 10 A * 8 pin plug-in * 3 pole, 10 A * 11 pin plug-in indicator (preferred version) * 90 series sockets * Coil EMC suppression * Timer accessories 86 series * European Patent For UL ratings see: "General technical information" page V For outline drawing see page 8 Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A V AC 2 CO (DPDT) 3 CO (3PDT) 10/20 10/20 250/400 250/400 Rated load AC1 VA 2500 2500 Rated load AC15 (230 V AC) VA 500 500 Single phase motor rating (230 V AC) kW 0.37 0.37 Breaking capacity DC1: 30/110/220 V A 10/0.4/0.15 10/0.4/0.15 mW (V/mA) 500 (10/5) 500 (10/5) AgNi AgNi Minimum switching load Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 2.2/1.3 2.2/1.3 AC (0.8...1.1)UN (0.8...1.1)UN DC (0.8...1.1)UN (0.8...1.1)UN Holding voltage AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 20 * 106 / 50 * 106 20 * 106 / 50 * 106 Electrical life at rated load AC1 cycles 200 * 103 200 * 103 ms 11/4 11/4 kV 4 3.6 1000 1000 -40...+70 -40...+70 RT I RT I Technical data I-2018www.findernet.com Operate/release time Insulation between coil and contacts (1.2/50 s) Dielectric strength between open contacts Ambient temperature range Environmental protection V AC C Approvals (according to type) 3 60 SERIES 60 SERIES General purpose relays 6 - 10 A 60.12 - 52xx Plug-in mount - 6 A Bifurcated contacts for low level switching Type 60.12 - 52xx - 2 pole, 6 A Type 60.13 - 52xx - 3 pole, 6 A * 2 & 3 pole changeover contacts * Cadmium Free contacts (Gold plated Silver Nickel) * AC coils & DC coils * Lockable test button with mechanical flag * 2 pole, 6 A * Bifurcated contacts with AgNi + Au * 8 pin plug-in indicator (preferred version) * 90 series sockets * Coil EMC suppression * Timer accessories 86 series * European Patent * 3 pole, 6 A * Bifurcated contacts with AgNi + Au * 11 pin plug-in For UL ratings see: "General technical information" page V For outline drawing see page 8 Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A 3 CO (3PDT) 6/10 6/10 250/400 250/400 Rated load AC1 VA 1500 1500 Rated load AC15 (230 V AC) VA 250 250 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load V AC 2 CO (DPDT) mW (V/mA) Standard contact material 0.185 0.185 6/0.3/0.12 6/0.3/0.12 50 (5/5) 50 (5/5) AgNi + Au AgNi + Au Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC Rated power AC/DC Operating range VA (50 Hz)/W 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 2.2/1.3 2.2/1.3 AC (0.8...1.1)UN (0.8...1.1)UN DC (0.8...1.1)UN (0.8...1.1)UN Holding voltage AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 20 * 106 / 50 * 106 20 * 106 / 50 * 106 Electrical life at rated load AC1 cycles 250 * 10 250 * 103 ms 11/4 11/4 kV 4 3.6 Technical data Operate/release time Insulation between coil and contacts (1.2/50 s) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 4 V AC C 3 1000 1000 -40...+70 -40...+70 RT I RT I I-2018www.findernet.com A 60.13 - 52xx 60 SERIES General purpose relays 6 - 10 A 60 SERIES 60.62 Flange mount - General purpose relay 10 A 60.63 Type 60.62 - 2 pole, 10 A A Type 60.63 - 3 pole, 10 A * Faston 187, (4.8 x 0.8 mm) * 2 & 3 pole changeover contacts * AC coils & DC coils * Cadmium Free contacts * Contacts material options * 2 pole, 10 A power contacts * Flange mount * Faston 187 * 3 pole, 10 A power contacts * Flange mount * Faston 187 For UL ratings see: "General technical information" page V For outline drawing see page 8 Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A 3 CO (3PDT) 10/20 10/20 250/400 250/400 Rated load AC1 VA 2500 2500 Rated load AC15 (230 V AC) VA 500 500 Single phase motor rating (230 V AC) kW 0.37 0.37 Breaking capacity DC1: 30/110/220 V A 10/0.4/0.15 10/0.4/0.15 mW (V/mA) 500 (10/5) 500 (10/5) AgNi AgNi Minimum switching load V AC 2 CO (DPDT) Standard contact material Coil specification Nominal voltage (UN) Rated power AC/DC Operating range V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 VA (50 Hz)/W AC DC 2.2/1.3 2.2/1.3 (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN Holding voltage AC/DC 0.8 UN / 0.5 UN 0.8 UN / 0.5 UN Must drop-out voltage AC/DC 0.2 UN / 0.1 UN 0.2 UN / 0.1 UN Mechanical life AC/DC cycles 20 * 106 / 50 * 106 20 * 106 / 50 * 106 Electrical life at rated load AC1 cycles 200 * 103 200 * 103 ms 11/4 11/4 kV 4 3.6 Technical data I-2018www.findernet.com Operate/release time Insulation between coil and contacts (1.2/50 s) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) V AC C 1000 1000 -40...+70 -40...+70 RT I RT I Z 5 60 SERIES General purpose relays 6 - 10 A 60 SERIES Ordering information Example: 60 series plug-in relay, 3 CO (3PDT), 12 V DC coil, test button and mechanical indicator. A 6 0 . 1 A B C D 3 . 9 . 0 1 2 . 0 0 4 0 A: Contact material 0 = Standard 5 = AgNi + Au Series Type 1 = 8/11 pin plug-in 6 = Faston 187 (4.8 x 0.8 mm) with flange mount D: Special versions 0 = Standard C: Options 0 =None 2 =Mechanical indicator 3 =LED (AC) 4 =Lockable test button + mechanical indicator 5* =Lockable test button + LED (AC) 54* =Lockable test button + LED (AC) + mechanical indicator 6* =LED + diode (DC, polarity positive to pin 2) 7* =Lockable test button + LED + diode (DC, polarity positive to pin 2) 74* =Lockable test button + LED + diode (DC, polarity positive to pin 2) + mechanical indicator * Options not available for 220 V DC and 400 V AC versions. B: Contact circuit 0 = CO (nPDT) 2 = Bifurcated contacts 60.12/13 - 6 A only No. of poles 2 = 2 pole 3 = 3 pole Coil version 4 = Current sensing (60.12/13 only) 8 = AC (50/60 Hz) 9 = DC Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 60.12/13 AC 0 0 0-2-3-4-5 0 AC 0 0 54 / AC 5 0-2 0-2-3-4-5 0 AC 5 0-2 54 / DC 0 0 0-2-4-6-7 0 DC 0 0 74 / DC 5 0-2 0-2-4-6-7 0 DC 5 0-2 74 / current sensing 0 0 4 0 AC-DC 0-5 0 0 0 60.62/63 C: Option 3, 5, 54 LED (AC) C: Option 6, 7, 74 LED + diode (DC, polarity positive to pin 2) R Descriptions: Options and Special versions OP EAN EU N T T E P A 2 6 I-2018www.findernet.com EAN 3 OP 1 EUR Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 60 SERIES General purpose relays 6 - 10 A 60 SERIES Technical data Insulation according to EN 61810-1 2 pole Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 250 Pollution degree 3 pole 230/400 3 400 250 400 2 3 2 A Insulation between coil and contact set Type of insulation Basic Basic Overvoltage category III III Rated impulse voltage kV (1.2/50 s) 4 Dielectric strength 3.6 V AC 2000 2000 Type of insulation Basic Basic Overvoltage category III III Insulation between adjacent contacts Rated impulse voltage kV (1.2/50 s) 4 Dielectric strength 3.6 V AC 2000 2000 Insulation between open contacts Type of disconnection Micro-disconnection Dielectric strength Micro-disconnection V AC/kV (1.2/50 s) 1000/1.5 Insulation between coil terminals Rated impulse voltage (surge) differential mode (according to EN 61000-4-5) Other data 1000/1.5 kV(1.2/50 s) 4 Bounce time: NO/NC ms 1/4 Vibration resistance (5...55)Hz: NO/NC g 22/22 Shock resistance g 20 Power lost to the environment without contact current W 1.3 1.3 with rated current W 2.7 (60.12, 60.62) 3.4 (60.13, 60.63) Contact specification H 60 -Maximum DC1 breaking capacity Resistive load - cos = 1 Inductive load - cos = 0.4 Cycles contacts in series DC breaking current (A) F 60 -Electrical life (AC) v contact current DC voltage (V) * When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100 * 103 can be expected. * In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. Coil specifications AC coil data DC coil data I-2018www.findernet.com Nominal voltage Coil code Operating range Resistance Rated coil absorption UN Umin Umax R I at UN V V V mA 6 9.006 4.8 6.6 28 214 12 9.012 9.6 13.2 110 109 Nominal voltage UN Coil code V 6 8.006 Operating range Umin Umax V V 4.8 6.6 Resistance R Rated coil absorption I at UN (50 Hz) mA 4.6 367 12 8.012 9.6 13.2 19 24 8.024 19.2 26.4 74 90 48 8.048 38.4 52.8 290 47 183 24 9.024 19.2 26.4 445 53.9 48 9.048 38.4 52.8 1770 27.1 60 9.060 48 66 2760 21.7 120 8.120 96 132 1940 18.6 110 9.110 88 121 9420 11.7 230 8.230 184 253 7250 10.5 125 9.125 100 138 12000 10.4 240 8.240 192 264 8500 9.2 220 9.220 176 242 37300 5.8 400 8.400 320 440 19800 60 8.060 48 66 450 37 110 8.110 88 121 1600 20 6 7 60 SERIES 60 SERIES General purpose relays 6 - 10 A Coil specifications R 60 - DC coil operating range v ambient temperature R 60 - AC coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. A Current sensing version Current sensing DC coil data Typical application with current sensing relays. An open circuit filiment of lamp L1 is detected by the current sensing relay coil (K1) which causes the back-up safety lamp L2 to be energised, and indication of failure at the control panel via lamp S1. Example: navigation light. L1 = Light L2 = Safety light S1= Control light K1 = Relay Coil code Imin (A) IN (A) Imax (A) 4202 1.7 2.0 2.4 0.15 4182 1.5 1.8 2.2 0.19 4162 1.4 1.6 1.9 0.24 4142 1.2 1.4 1.7 0.31 4122 1.0 1.2 1.4 0.42 4102 0.85 1.0 1.2 0.61 4092 0.8 0.9 1.1 0.75 4062 0.5 0.6 0.7 1.70 4032 0.25 0.3 0.4 4012 0.085 0.1 0.15 R () 6.70 61 Current sensing AC coil data Coil code Imin (A) IN (A) Imax (A) 4251 2.1 2.5 3.0 0.05 4181 1.5 1.8 2.2 0.10 4161 1.4 1.6 1.9 0.12 4121 1.0 1.2 1.4 0.22 4101 0.85 1.0 1.2 0.32 4051 0.42 0.5 0.6 1.28 4041 0.34 0.4 0.5 2.00 4031 0.25 0.3 0.4 3.57 4021 0.17 0.2 0.25 8.0 4011 0.085 0.1 0.15 32.1 R () Other types of current sensing relays are available on request. Outline drawings Type 60.13/60.13 - 52xx Type 60.62 Type 60.63 I-2018www.findernet.com Type 60.12/60.12 - 52xx 8 90 SERIES Socket overview for 60 series relays 60 SERIES Accessories Module Socket Relay Description Mounting Accessories 99.02 90.02 90.03 60.12 60.13 Screw terminal (Box clamp) socket Double A1 terminal Panel or 35 mm rail (EN 60715) mount -C oil indication and EMC suppression modules - J umper link - Timer modules -M etal retaining clip Module Socket Relay Description Mounting Accessories 99.01 90.20 90.21 60.12 60.13 Screw terminal (Box clamp) socket Panel or 35 mm rail (EN 60715) mount -C oil indication and EMC suppression modules -M etal retaining clip Module Socket Relay Description Mounting Accessories -- -- 90.82.3 90.83.3 60.12 60.13 Screw terminal (Box clamp) socket Panel or 35 mm rail (EN 60715) mount -M etal retaining clip Module Socket Relay Description Mounting Accessories -- -- 90.22 90.23 60.12 60.13 Screw terminal (Box clamp) socket Panel or 35 mm rail (EN 60715) mount -M etal retaining clip Module Socket Relay Description Mounting Accessories -- -- 90.26 90.27 60.12 60.13 Screw terminal (Plate clamp) socket Panel or 35 mm rail (EN 60715) mount -M etal retaining clip Module Socket Relay Description Mounting Accessories -- -- 90.12 90.13 60.12 60.13 Flange mount solder socket M3 screw fixing -- Module Socket Relay Description Mounting Accessories -- -- -- -- 90.14 90.14.1 90.15 90.15.1 60.12 60.12 60.13 60.13 PCB socket PCB -- 90.03 See page 10 See page 11 See page 12 See page 12 See page 13 See page 13 I-2018www.findernet.com See page 14 A 90.21 90.83.3 90.23 90.26 90.12 90.15 Sheet of marker tags (CEMBRE Thermal transfer printers) for relay types 60.12 and 60.13, plastic, 48 tags, 6 x 12 mm 060.48 060.48 9 90 SERIES Sockets and accessories for 60 series relays 60 SERIES A Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount 90.02 Blue For relay type 60.12 90.02.0 Black 90.03 Blue 90.03.0 Black 60.13 Accessories 90.03 Approvals (according to type): Metal retaining clip 090.33 6-way jumper link 090.06 Identification tag 090.00.2 Modules (see table below) 99.02 Timer modules (see table below) 86.00, 86.30 Technical data Certain relay/socket combinations Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category Ambient temperature Screw torque Wire strip length IP 20 C -40...+70 Nm 0.6 mm 10 P A PEAN N T E O O T EUR EUR Max. wire size for 90.02 and 90.03 sockets solid wire stranded wire mm2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 6-way jumper link for 90.02 and 90.03 sockets 090.06 (blue) Rated values 10 A - 250 V 090.06.0 (black) Approvals (according to type): PEAN 090.06 86 series timer modules 86.00 Multi-voltage: (12...240)V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s...100 h) 86.00.0.240.0000 (12...24)V AC/DC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.0.024.0000 (110...125)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.8.120.0000 (230...240)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.8.240.0000 Approvals (according to type): 99.02 coil indication and EMC suppression modules for 90.02 and 90.03 sockets 99.02 Approvals (according to type): Diode (+A1, standard polarity) LED LED (28...60)V DC/AC 99.02.0.060.59 LED (110...240)V DC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99 LED + Varistor (6...24)V DC/AC 99.02.0.024.98 LED + Varistor (28...60)V DC/AC 99.02.0.060.98 LED + Varistor (110...240)V DC/AC 99.02.0.230.98 RC circuit RC circuit DC Modules with nonstandard polarity (+A2) on RC circuit request. Residual current by-pass 10 (6...220)V DC 99.02.3.000.00 (6...24)V DC/AC 99.02.0.024.59 (6...24)V DC/AC 99.02.0.024.09 (28...60)V DC/AC 99.02.0.060.09 (110...240)V DC/AC 99.02.0.230.09 (110...240)V AC 99.02.8.230.07 I-2018www.findernet.com 86.30 90 SERIES Sockets and accessories for 60 series relays 60 SERIES Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount 90.20 Blue For relay type 60.12 90.20.0 Black 90.21 Blue 90.21.0 Black 60.13 A Accessories 90.21 Approvals (according to type): Metal retaining clip (supplied with socket - packaging code SMA) 090.33 Modules (see table below) 99.01 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category Ambient temperature Screw torque Wire strip length Max. wire size for 90.20 and 90.21 sockets 90.20 IP 20 C -40...+70 Nm 0.5 mm 10 solid wire stranded wire mm2 1 x 6 / 2 x 2.5 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 10 / 2 x 14 90.21 99.01 coil indication and EMC suppression modules for 90.20 and 90.21 sockets Blue* Diode (+A1, standard polarity) Diode (+A2, non-standard polarity) 99.01 Approvals (according to type): LED (6...220)V DC 99.01.3.000.00 (6...220)V DC 99.01.2.000.00 (6...24)V DC/AC 99.01.0.024.59 LED (28...60)V DC/AC 99.01.0.060.59 LED (110...240)V DC/AC 99.01.0.230.59 LED + Diode (+A1, standard polarity) (6...24)V DC 99.01.9.024.99 LED + Diode (+A1, standard polarity) (28...60)V DC 99.01.9.060.99 LED + Diode (+A1, standard polarity) * Modules in Black LED + Diode (+A2, non-standard polarity) housing are available on LED + Diode (+A2, non-standard polarity) request. LED + Diode (+A2, non-standard polarity) Green LED is standard. LED + Varistor Red LED available on LED + Varistor request. LED + Varistor (110...220)V DC 99.01.9.220.99 (6...24)V DC 99.01.9.024.79 (28...60)V DC 99.01.9.060.79 (110...220)V DC 99.01.9.220.79 (6...24)V DC/AC 99.01.0.024.98 (28...60)V DC/AC 99.01.0.060.98 (110...240)V DC/AC 99.01.0.230.98 RC circuit (6...24)V DC/AC 99.01.0.024.09 RC circuit (28...60)V DC/AC 99.01.0.060.09 RC circuit (110...240)V DC/AC 99.01.0.230.09 (110...240)V AC 99.01.8.230.07 I-2018www.findernet.com Residual current by-pass 11 60 SERIES 90 SERIES Sockets and accessories for 60 series relays A Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount 90.82.3 Blue For relay type 60.12 90.82.30 Black 90.83.3 Blue 90.83.30 Black 60.13 Accessories Metal retaining clip 90.83.3 Approvals (according to type): 090.33 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category Ambient temperature Screw torque Max. wire size for 90.82.3 and 90.83.3 sockets IP 20 C -40...+70 Nm 0.8 solid wire stranded wire mm2 1 x 6 / 2 x 4 1x6/2x4 AWG 1 x 10 / 2 x 14 1 x 10 / 2 x 14 90.82.3 90.83.3 Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount 90.22 Blue 90.23 Blue For relay type 60.12 60.13 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 90.23 Approvals (according to type): 090.33 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category Ambient temperature Screw torque Wire strip length Max. wire size for 90.22 and 90.23 sockets Nm 0.5 mm 7 solid wire stranded wire mm2 1 x 6 / 2 x 2.5 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 10 / 2 x 14 90.23 I-2018www.findernet.com 90.22 IP 20 C -40...+70 12 90 SERIES Sockets and accessories for 60 series relays 60 SERIES Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount 90.26 Blue For relay type 60.12 90.26.0 Black 90.27 Blue 90.27.0 Black 60.13 A Accessories 90.26 Approvals (according to type): Metal retaining clip (supplied with socket - packaging code SMA) 090.33 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Protection category IP 20 Ambient temperature C -40...+70 Screw torque Nm 0.8 Wire strip length mm 10 Max. wire size for 90.26 and 90.27 sockets mm 2 solid wire stranded wire 1 x 4 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 12 / 2 x 14 90.26 90.12 Approvals (according to type): 1 x 12 / 2 x 14 90.27 Flange mount solder socket mount with M3 screw 90.12 (black) 90.13 (black) For relay type 60.12 60.13 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Ambient temperature 90.13 I-2018www.findernet.com 90.12 C -40...+70 13 60 SERIES 90.15 Approvals (according to type): PCB socket Blue 90.14 (O 20.5 mm) Blue 90.14.1 (O 17.5 mm) 90.15 (O 22 mm) 90.15.1 (O 19 mm) For relay type 60.13 60.12 Technical data Rated values 10 A - 250 V Dielectric strength 2 kV AC Ambient temperature 90.14 C -40...+70 90.14.1 90.15 90.14 90.15.1 90.14 90.15 90.15 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 9 0 . 2 1 S M A A Standard packaging SM Metal retaining clip 9 0 . 2 1 Without retaining clip I-2018www.findernet.com A 90 SERIES Sockets and accessories for 60 series relays 14 Please see general technical information