UTO SERIES Robust Metal & Shielded Connector Overview UTO Series | Contents 06 07 08 10 12 126 127 128 128 129 131 132 133 Tooling .............................................................. Crimping Instructions ....................................... Handle & Interchangeable Heads .................... Extraction Tools ................................................ Dimensions Overmoulded Harnesses .............. Assembly Instructions ....................................... Mated Connector Length ................................. Rated Current & Working Voltage .................... Shielding Effectiveness/Corrosion .................... UL94 + UL1977 ................................................. IEC 61984 with IP Code Explanation ................ IEC 61140 Explained ........................................ What is NEMA Rating ? .................................... Ethernet for the Layman ................................... 139 140 142 143 143 144 153 155 156 157 160 162 163 164 Technical Information 16 20 28 32 40 48 52 60 64 72 80 84 88 92 96 100 104 108 112 116 120 Contacts Technical Information Connector Cable Assembly ................................................ 2 contacts + ground ......................................... 3 contacts + ground ......................................... 4 contacts ......................................................... 6 contacts ......................................................... 6 contacts + ground ......................................... 8 contacts ......................................................... 10 contacts ....................................................... 12 contacts ....................................................... 19 contacts ....................................................... 23 contacts ....................................................... 26 contacts ....................................................... 28 contacts ....................................................... 30 contacts ....................................................... 32 contacts ....................................................... 35 contacts ....................................................... 38 contacts ....................................................... 41 contacts ....................................................... 48 contacts ....................................................... 55 contacts ....................................................... 61 contacts ....................................................... Description ....................................................... Contact Plating Selector Guide ........................ Contact Selector Guide .................................... Packaging ......................................................... Crimp Contacts ................................................ #16 Coaxial Contacts ....................................... PCB Contacts ................................................... Fiber Optic Contacts ........................................ Appendices #16 Coaxial Contacts/Cabling Notices ............ Glossary of Terms ............................................. Drilling Pattern ................................................. Discrimination/Keying Methods ....................... Part Number Index ........................................... 168 175 176 180 181 Appendices Typical Applications .......................................... Features & Benefits .......................................... Range Overview ............................................... Layouts ............................................................. General Technical Characteristics ..................... Contacts Connector Overview 3 UTO SERIES (c) 2013 SOURIAU - SOURIAU is a registered trademark UTO Series Overview Typical Applications ................................................................................................ 06 Features & Benefits ................................................................................................ 07 Range Overview ..................................................................................................... 08 Layouts ................................................................................................................... 10 General Technical Characteristics ........................................................................... 12 5 UTO Series | Overview (c) Olivier Tuffe / Fotolia Instrumentation measurement Telecom - Data infrastructure 6 Building Automation & Control (c) Sergey Milovidov / Fotolia Robotics - Machine tools (c) SOURIAU Energy - Power Off road - Mining - Railway (c) Volodymyr Kyrylyuk / Fotolia (c) Vibe Images / Fotolia (c) Rainer Plendl / Fotolia Typical Applications UTO Series | Overview Features & Benefits IP68/69K Dynamic Mated Ideal for outdoor and indoor dynamic applications requiring continuous underwater immersion, routine pressure washing and dust protection. Overview WATER PROOF EMI Shielded SIGNAL INTEGRITY 65 dB at 100 Mhz: Qualified and compatible to be used in electromagnetic radiation areas and ensures proper signal integrity and transmission. Salt Spray 48 & 96 Hours CORROSION RESISTANT Designed to withstand climate ingress and exposure to salt spray or corrosive atmospheres while still maintaining mechanical and electrical functionality. 1/3 Bayonet Coupling QUICK MATING With only 1/3 twist of the bayonet coupling system, connectors are mated with audible "click" and tactile feel to confirm proper mating. This mating features eliminates connection uncertainty and reduces time and labor during installation. Mixed Power & Signal Layouts COST SAVINGS Power supply and signal transmission can be combined in a unique interconnect solution to reduce system complexity and minimize component/installation costs. 7 UTO Series | Overview Range Single Wire Sealing Straight Strain Relief Right Angle Strain Relief Choice of Crimp Contacts * machined * stamped and formed * coaxial * fiber optics Short Cable Gland Long Cable Gland UTO Series Heat Shrink Boot Adapter Sealed: IP68/69K Shielded Corrosion resistant UL compliant Overmoulded 8 Plug UTO Series | Overview Overview Overview Single Wire Sealing Receptacle Choice of Crimp Contacts * machined * stamped and formed * coaxial * fiber optics Straight Strain Relief PCB Contact Heat Shrink Boot Adapter 9 UTO Series | Overview Layouts Shell size 10 (Electrical parameter according to IEC 61984 & IEC 61140) Contact #16 (O 1.6) Contact #20 (O 1.0) Contact #8 (O 3.6) Mixed Power 103 104* 106* 102W2 103W3 16A 150V 2 contacts +ground 13A 150V 4 contacts 7A 80V 6 contacts 25A 200V 4 contacts 5A 40V 6 contacts 4xO1.6 (#16) 6xO1.0 (#20) 2xO2.4 (#12) 2xO1.0 (#20) 3xO1.6 (#16) 3xO1.0 (#20) Page 36 Page 44 Page 32 124 128 1210* 16A 150V 3 contacts +ground 10A 125V 8 contacts 6A 40V 10 contacts 8xO1.6 (#16) 10xO1.0 (#20) Page 52 Page 60 147 1412 1419 142G1 148 16A 150V 6 contacts +ground 10A 150V 12 contacts 5A 40V 19 contacts 17A 230V 8 contacts 12xO1.6 (#16) 19xO1.0 (#20) 40A 250V 2 contacts +ground 3xO1.6 (#16) Page 20 Page 40 4xO1.6 (#16) 12 Page 28 7xO1.6 (#16) 14 Page 48 Page 64 Page 72 1492 10A 150V 12 contacts 12xO1.6 (#16) Page 68 1619* 1626 9A 150V 19 contacts 4A 40V 26 contacts 19xO1.6 (#16) 26xO1.0 (#20) Page 76 Page 84 16 * Ethernet compatible see page 168 & 169 10 3xO3.6 (#8) 4xO2.4 (#12) 4xO1.6 (#16) Page 24 Page 56 UTO Series | Overview Contacts #16: from AWG 30 to 14, 0.05 to 2.5 mm Contacts #20: from AWG 26 to 18, 0.13 to 0.93 mm Shell size Contacts #8: from AWG 16 to 8, 1.5 to 10 mm Contacts #12: fromAWG 22 to 12, 0.13 to 4 mm Contact #16 (O 1.6) Contact #20 (O 1.0) 1823 1832 8A 150V 23 contacts 4A 50V 32 contacts 23xO1.6 (#16) 32xO1.0 (#20) Page 80 Page 96 Overview 18 2028 2030 2041 7A 150V 28 contacts 7A 150V 30 contacts 8A 80V 41 contacts 28xO1.6 (#16) 30xO1.6 (#16) 41xO1.0 (#20) Page 88 Page 92 Page 108 20 2235 2238 2255 6A 150V 35 contacts 6A 150V 38 contacts 3A 80V 55 contacts 35xO1.6 (#16) 38xO1.6 (#16) 55xO1.0 (#20) Page 100 Page 104 Page 116 22 2448 2461 6A 160V 48 contacts 3A 80V 61 contacts 48xO1.6 (#16) 61xO1.0 (#20) Page 112 Page 120 24 11 UTO Series | Overview General technical characteristics Materials Environmental Electrical * Shell: Zinc alloy * Operating temperature: from -40C to +105C 40/100/21 per NFF 61-030 * In accordance with: - UL 1977: Certificate ECBT2 File number: E169916 - CSA C22.2: Certificate ECBT8 File number E169916 * Backshells and cable glands: Brass * Coupling ring: Aluminum alloy * Coupling spring: Spring stainless steel * Insert: Glass-filled thermoplast * Contacts: See page 129 * Halogen free * RoHS compliant & conforms to the Chinese standard SJ/T1166-2006 (Chinese RoHS equivalent) * Flammability rating: UL94 V-0 I2F3 according to NFF 16101 and NFF 16102 * Salt spray: per MIL-STD-202 method 101 - 48 h (standard version) - 96 h (black anodized coupling ring) Higher salt spray resistance (200/500 h) upon request * Sealing: Per IEC 60529/DIN 40050: Dynamic IP67 / IP68 (under 10 m of water during 1 week) / IP69K in mated condition and in combination with sealed backshell. * Fluid resistance: - Gas and oil - Mineral oil - Acid bath - Basic bath * Shielding effectiveness: 65 dB at 100 MHz 12 * Also see pages 10 & 11 Mechanical * Durability: 500 matings & unmatings per MIL-C-26482 * Vibration resistance: 55-2000 Hz, acceleration 15 g per MIL-C-26482 (Series 1) 10-100 Hz, acceleration 2 g per NFF61030 * Thermal shock: 5 cycles 30 min. from -40C to 105C per MIL-STD-202 method 207 * Mechanical shock: 50 g, 11 ms period per MIL-C-26482 (Series 1) 30 g, 18 ms period per NFF61030 Overview UTO Series | Overview 13 UTO SERIES (c) 2013 SOURIAU - SOURIAU is a registered trademark UTO Series Connector Upgrade of the UTO Series .................................................................................... Cable Assembly ...................................................................................................... 2 contacts + ground 103: 10A 500V ................................................................... 142G1: 44A 600V ................................................................... 3 contacts + ground 124: 16A 500V ................................................................... 4 contacts 102W2: 20A 500V ................................................................... 104*: 10A 500V ................................................................... 6 contacts 103W3: 5A 250V ................................................................... 106*: 5A 250V ................................................................... 6 contacts + ground 147: 10A 500V ................................................................... 8 contacts 128: 10A 500V ................................................................... 148: 25A 250V ................................................................... 10 contacts 1210*: 5A 250V ................................................................... 12 contacts 1412: 10A 500V ................................................................... 1492: 10A 500V ................................................................... 19 contacts 1419: 5A 250V ................................................................... 1619*: 9A 500V ................................................................... 23 contacts 1823: 8A 500V ................................................................... 26 contacts 1626: 4A 250V ................................................................... 28 contacts 2028: 5A 500V ................................................................... 30 contacts 2030: 5A 500V ................................................................... 32 contacts 1832: 4A 250V ................................................................... 35 contacts 2235: 5A 500V ................................................................... 38 contacts 2238: 5A 500V ................................................................... 41 contacts 2041: 3A 250V ................................................................... 48 contacts 2448: 5A 500V ................................................................... 55 contacts 2255: 3A 250V ................................................................... 61 contacts 2461: 3A 250V ................................................................... Electrical parameters according to UL1977 16 17 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 100 104 108 112 116 120 * Ethernet compatible see pages 164 & 165 15 UTO Series | Connector Upgrade of the UTO Series Old UTO New UTO Description of change: To better meet the demanding requirements and diversity of industrial markets/applications, SOURIAU changed the position of the wavy washer inside the plug. This slight modification makes the new version of the UTO sealed to IP68/69K in dynamic conditions. Product part number: Below is an overview of the old part numbers with the corresponding new part numbers. Note that some of the old part numbers where backshells were included will now be sold individually, i.e. plug connector + backshell. 16 Old part number New part number connector New part number backshell Comments UTO0/6-S/PT UTO0-S/PHT UT00/6-S/PH(6) - - UT00-S/PH(6) - - UTO0/6AC-S/PT UT00/6-S/PH(6) - - UTO0/6PG-S/PHT UT00/6-S/PH(6) UT0-AC - UTO-21/22- Keep old part number UT0-JC Silksreen version UTO-44/45- Keep old part number - Screw coupling version UTO-ACT - UT0-AC 851 backshell Nickel plated UTO-PGT - UT0-JC Longer threading on connector side + metric cable gland UTOS-PGT - UT0S-JC Longer threading on connector side + shielded metric cable gland U-AD01T UT0-AD01 UT0-AD01 Longer threading to achieve sealing U-AD01N Keep old part number - Used on old UT06-45N screw coupling version UTO Series | Connector Cable Assembly Connector SOURIAU has provided connectors for various applications for more than 90 years and has been used in the most extreme environments. Conscious about the difficulty in finding a quick and reliable harness manufacturer, we began our own in-house cable assembly production. It allows customers to reduce the number of suppliers and to take advantage of the "best in class" quality of the SOURIAU group. Overmoulding is a process that further enhances the sealing properties and helps to minimize stress on the cable termination to the connector. In addition, the wires are encapsulated inside the molding which creates a barrier preventing liquid/moisture from entering the equipment through the connector or cable jacket if breached. How to choose the outer jacket material TPE Chemical aggression Wet Immersed Static installation OUTDOOR SILICON Static installation FEP Static installation (black outer jacket) PUR Static or dynamic installation PTFE Static installation INDOOR UV resistance Cleaner, chlorine Please consult us PVC Static installation 0C 70C Ambient temperature 17 UTO Series | Connector Overmoulding Description O-ring Compound Thermoplastic insert Overmoulding adapter Braid Cable outer sheath PVC or PUR overmoulding Discrete connector If cable jacket is breached... GOOD ...water ingress unhampered, leading to damage. Overmoulded connector If cable jacket is breached... BEST ...prevents water ingress via capillary action. 18 UTO Series | Connector UTO Robust Metal & Shielded Cable Assembly Description Connector * * * * Shielded metal connector Extreme sealing: IP68/69K dynamic mated 26 layouts Rapid 1/3 turn connection Cable * TPE outer sheath (black) * 300V * Shielded * Flammability rating UL 1581 Sec.1080 (VW-1) Connector Applications * Machining Centers (Oil Resistant) * Assembly Automation Equipment * Geophysical Equipment * Solar (UV Stable) * Outdoor Displays Specifications PLATING SALT SPRAY Black anodized* 96 H Nickel 48 H DEGREE WATERPROOF COUPLING -40 C up to 105 C IP68/69K dynamic mated 500 matings/unmatings * Custom black anodized version available on demand Custom Capabilities Harness with custom cable Harness with double ends Y or T shape connection 19 UTO Series | Connector 103 (Shell size 10, 2 + ground, 3x#16) OR OR OR Layout OR WITH Connector Part Numbers Drilling pattern see page 176 Part number Contact type Connector type Sealing Male insert Female insert IP67 96h UT00103PH UT00103SH IP68 & IP69K 96h UT00103PH6 UT00103SH6 IP67, IP68 & IP69K 48h UT06103PH UT06103SH IP67, IP68 & IP69K 96h UT06103PH02(Black) UT06103SH02(Black) IP67 48h UT07103PH UT07103SH IP68 & IP69K 48h UT07103PH6 UT07103SH6 IP67 96h UT07103PH01 UT07103SH01 IP68 & IP69K 96h UT07103PH601 UT07103SH601 Square flange receptacle Contacts supplied separately see page 23 Salt spray Plug Jam nut receptacle Backshells 20 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 3/6 UT010JCS UT010JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 5/8 UT010JCSL UT010JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL Metal cable clamp with strain relief (Fig.5) - 5 Metal shrink boot adaptor (Fig.6) - - UT010AD Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN UT010AC 16A/150V per IEC 61984 UTO Series | Connector 103 (Shell size 10, 2 + ground, 3x#16) 2+ Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 23.8 33 maxi 21.8 Male O 20.0 Male Female 1.6 Female 18.2 25.2 maxi 25.5 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 27 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 14.2 Rear mounting O 17.3 Female 17.9 33 maxi 22.2 18.2 16.5 18.2 O 14.9 Male .4 17 Backshells (for Mated Connector Length: See Page 153) Long version - 61.1 Long version - 61.1 31.0 Fig. 1 Fig. 2 21.6 24.7 O 21.0 Short version - 49.1 O 16.3 Short version - 49.1 Fig. 6 Fig. 5 48.0 Short version - 60.1 Long version - 71.1 Long version - 71.1 60.6 30.0 Short version - 59.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 21 UTO Series | Connector 103 (Shell size 10, 2 + ground, 3x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT010DCG* UTG610DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD12B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT010DC 22 = Head Complete set 16A/150V per IEC 61984 UTO Series | Connector 103 (Shell size 10, 2 + ground, 3x#16) 2+ Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 103 Derating Curves Current (A) UL 10A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 16A 150V 2.5kV 3 30 28 25 Test conditions 23 Contact used: Machined contacts Wires used: 1.31mm 15 20 18 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 23 UTO Series | Connector 142G1 (Shell size 14, 2 + ground, 3x#8) OR OR OR OR Layout WITH Connector Part Numbers Drilling pattern see page 176 Part number Contact type Connector type Sealing Male insert Female insert IP67 96h UT00142G1PH UT00142G1SH IP68 & IP69K 96h UT00142G1PH6 UT00142G1SH6 IP67, IP68 & IP69K 48h UT06142G1PH UT06142G1SH IP67, IP68 & IP69K 96h UT06142G1PH02(Black) UT06142G1SH02(Black) IP67 48h UT07142G1PH UT07142G1SH IP68 & IP69K 48h UT07142G1PH6 UT07142G1SH6 IP67 96h UT07142G1PH01 UT07142G1SH01 IP68 & IP69K 96h UT07142G1PH601 UT07142G1SH601 Square flange receptacle Contacts supplied separately see page 27 Salt spray Plug Jam nut receptacle Backshells 24 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT014JCS UT014JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT014JCSL UT014JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL Metal cable clamp with strain relief (Fig.5) - 10 Metal shrink boot adaptor (Fig.6) - - UT014AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN UT014AC 40A/250V per IEC 61984 UTO Series | Connector 142G1 (Shell size 14, 2 + ground, 3x#8) 2+ Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 34 maxi 28.6 29.3 Male O 26.8 Male Female 1.6 Female 34 23.0 33 maxi Jam Nut - UTO7 33.9 maxi Panel Cut Out 35 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 21.5 Rear mounting O 25 Female 17.9 33 maxi 30.2 23.0 24.1 23.0 O 22.1 Male .5 25 Backshells (for Mated Connector Length: See Page 153) Long version - 68.1 Long version - 69.1 34.0 Fig. 1 Fig. 2 27.4 24.7 O 27.0 Short version - 53.1 O 22.5 Short version - 52.1 Fig. 6 Fig. 5 52.0 Short version - 65.1 Long version - 81.1 Long version - 81.1 67.7 36.5 Short version - 65.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 25 UTO Series | Connector 142G1 (Shell size 14, 2 + ground, 3x#8) Accessories and Tooling Dustcap (Receptacle) Hand Tool Dustcap (Plug) Part number Part number UT014DCG* UTG614DCG* Part number M317 Gasket Positioner + locator setting Part number / Neoprene UTFD14B Part number VGE10078A Extraction Tool #8 Part number 51060210936 * For dustcap without chain, skip "G", e.g. UT014DC 26 40A/250V per IEC 61984 UTO Series | Connector 142G1 (Shell size 14, 2 + ground, 3x#8) 2+ Contacts PCB Crimp #8 Contact type Machined Machined (2) Part number Male Female Max wire O 16 82913601A 82913600A 1.72 14 82913603A 82913602A 2.22 12 82913605A 82913604A 2.82 10 82913607A 82913606A 3.50 8 82913609A 82913608A 4.35 - 82911685NPC(1) 82911684NPC(1) - AWG (1): Example of plating, for other plating options see page 129 (2): For dimensions see page 132 Max insulator O 6.5 Note: all dimensions are in mm Electrical Characteristics UTO 142G1 Derating Curves Current (A) 50 UL 44A 600V UL94 V-0 CSA 30A 600V UL94 V-0 IEC 40A 250V 3kV 3 45 40 Test conditions 35 30 25 Contact used: Machined contacts Wires used: 6mm 20 15 10 5 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 27 UTO Series | Connector 124 (Shell size 12, 3 + ground, 4x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 31 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number Male insert Female insert 96h UT00124PH UT00124SH IP68 & IP69K 96h UT00124PH6 UT00124SH6 IP67, IP68 & IP69K 48h UT06124PH UT06124SH IP67, IP68 & IP69K 96h UT06124PH02(Black) UT06124SH02(Black) IP67 48h UT07124PH UT07124SH IP68 & IP69K 48h UT07124PH6 UT07124SH6 IP67 96h UT07124PH01 UT07124SH01 IP68 & IP69K 96h UT07124PH601 UT07124SH601 Plug Jam nut receptacle Backshells 28 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT012JCS UT012JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT012JCSL UT012JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S12JCS UT0S12JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S12JCSL UT0S12JCL Metal cable clamp with strain relief (Fig.5) - 8.2 UT012AC Metal shrink boot adaptor (Fig.6) - - UT012AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/12 UT012LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 04/11.9 UT0S12JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 04/11.9 UT012JCPGN 16A/150V per IEC 61984 UTO Series | Connector 124 (Shell size 12, 3 + ground, 4x#16) Dimensions 3+ Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 26.2 26.1 Male O 23.6 Male Female 1.6 Female 25.5 maxi 20.6 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 32 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 18.4 Rear mounting O 21.8 Female 17.9 33 maxi 27 20.6 21.0 20.6 O 18.9 Male .2 22 Backshells (for Mated Connector Length: See Page 153) Long version - 62.1 Long version - 63.1 31.5 Fig. 1 Fig. 2 25.0 24.7 O 27.0 Short version - 50.1 O 19.4 Short version - 49.1 Fig. 6 Fig. 5 50.0 Short version - 62.1 Long version - 75.1 Long version - 75.1 62.7 33.5 Short version - 62.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 29 UTO Series | Connector 124 (Shell size 12, 3 + ground, 4x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT012DCG* UTG612DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD13B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT012DC 30 = Head Complete set 16A/150V per IEC 61984 UTO Series | Connector 124 (Shell size 12, 3 + ground, 4x#16) Contacts #16 3+ Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 124 Derating Curves Current (A) 30 UL 16A 500V UL94 V-0 CSA 13A 500V UL94 V-0 IEC 16A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 31 UTO Series | Connector 102W2 (Shell size 10, 2x#12 + 2x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 35 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number Male insert Female insert 96h UT00102W2PH UT00102W2SH IP68 & IP69K 96h UT00102W2PH6 UT00102W2SH6 IP67, IP68 & IP69K 48h UT06102W2PH UT06102W2SH IP67, IP68 & IP69K 96h UT06102W2PH02(Black) UT06102W2SH02(Black) IP67 48h UT07102W2PH UT07102W2SH IP68 & IP69K 48h UT07102W2PH6 UT07102W2SH6 IP67 96h UT07102W2PH01 UT07102W2SH01 IP68 & IP69K 96h UT07102W2PH601 UT07102W2SH601 Plug Jam nut receptacle Backshells 32 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 3/6 UT010JCS UT010JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 5/8 UT010JCSL UT010JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL Metal cable clamp with strain relief (Fig.5) - 5 Metal shrink boot adaptor (Fig.6) - - UT010AD Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN UT010AC 25A/200V per IEC 61984 UTO Series | Connector 102W2 (Shell size 10, 2x#12 + 2x#20) Dimensions Square Flange - UTO0 33.3 maxi Plug - UTO6 23.8 11.3 33 maxi 4 21.8 Male O 20 Male Female Female 1.6 18.2 32 maxi 25.5 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 27 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 14.2 Rear mounting O 17.3 Female 17.9 33 maxi 22.2 18.2 16.5 18.2 O 14.9 Male .4 17 Backshells (for Mated Connector Length: See Page 153) Long version - 61.1 Long version - 61.1 31.0 Fig. 1 Fig. 2 21.6 24.7 O 21.0 Short version - 49.1 O 16.3 Short version - 49.1 Fig. 6 Fig. 5 48.0 Short version - 60.1 Long version - 71.1 Long version - 71.1 60.6 30.0 Short version - 59.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 33 UTO Series | Connector 102W2 (Shell size 10, 2x#12 + 2x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Crimp Tooling #20 Part number Part number Part number Part number UT010DCG* UTG610DCG* SHANDLES TOOLKIT Gasket Contacts Part number of head Contact size Part number / Neoprene RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) UTFD12B S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES Crimp Tooling #12 + Handle = Head Complete set Extraction Tool #20 Part number Hand Tool M317 Part number positioner + locator setting VGE10077A Part number RX20D44 Extraction Tooling #12 Part number Extraction Tool 51060210924 * For dustcap without chain, skip "G", e.g. UT010DC 34 25A/200V per IEC 61984 UTO Series | Connector 102W2 (Shell size 10, 2x#12 + 2x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - AWG SM20W3S26 SC20W3S25 - RMW5016K RCW5016K - 22 82911457NA 82911456A 0.87 4 Crimp #12 Machined 20 82911459NA 82911458A 1.12 18 82911461NA 82911460A 1.42 16 82911463NA 82911462A 1.72 14 82911465NA 82911464A 2.22 12 82911467NA 82911466A 2.82 (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 or SM24WL3S26 (3): For dimensions see page 132 4.90 Note: all dimensions are in mm Electrical Characteristics UTO 102W2 Derating Curves Current (A) 50 UL 20A 500V UL94 V-0 CSA 18A 500V UL94 V-0 IEC 25A 200V 3kV 3 45 40 Test conditions Contact used: Machined contacts Wires used: 0.518mm 3.300mm 35 30 25 20 15 10 5 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 35 UTO Series | Connector 104 (Shell size 10, 4x#16) WITH OR SINGLE WIRE SEALING (1) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 39 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 IP68 & IP69K Part number* Male insert Female insert 96h UT00104PH UT00104SH 96h UT00104PH6 UT00104SH6 (1) UT06104SH(1) IP67, IP68 & IP69K 48h UT06104PH IP67, IP68 & IP69K 96h UT06104PH02(1) IP67 48h UT07104PH(1) UT07104SH(1) IP68 & IP69K 48h UT07104PH6(1) UT07104SH6(1) IP67 96h UT07104PH01(1) UT07104SH01(1) IP68 & IP69K 96h UT07104PH601(1) Plug Jam nut receptacle * Other discrimination keying option, see page 182 (Black) UT06104SH02(1) (Black) UT07104SH601 (1) (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN104PH Backshells 36 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 3/6 UT010JCS UT010JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 5/8 UT010JCSL UT010JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL Metal cable clamp with strain relief (Fig.5) - 5 Metal shrink boot adaptor (Fig.6) - - UT010AD Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN UT010AC 13A/150V per IEC 61984 UTO Series | Connector 104 (Shell size 10, 4x#16) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 23.8 33 maxi 4 21.8 Male O 20 Male Female 1.6 Female 18.2 25.2 maxi 25.5 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 27 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 14.2 Rear mounting O 17.3 Female 17.9 33 maxi 22.2 18.2 16.5 18.2 O 14.9 Male .4 17 Backshells (for Mated Connector Length: See Page 157) Short version - 49.1 O 22.0 Short version - 49.1 49.9 O 22.0 13.0 GN plastic GJC plastic 31.0 Short version - 59.1 O 21.0 Fig. 2 21.6 Fig. 1 24.7 Long version - 61.1 O 16.3 Long version - 61.1 Short version - 60.1 Fig. 5 48.0 Fig. 6 30.0 60.6 Long version - 71.1 Fig. 3 Long version - 71.1 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 37 UTO Series | Connector 104 (Shell size 10, 4x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT010DCG* UTG610DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD12B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT010DC 38 = Head Complete set 13A/150V per IEC 61984 UTO Series | Connector 104 (Shell size 10, 4x#16) Contacts #16 Contact type Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece Female Max wire O Max insulator O 30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00 26-24 RM24M9K(1) RC24M9K(1) 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - PCB - Coaxial Cable Multipiece Twisted pair Multipiece RC14M30K SM24M1TK6(1)(2) 14 Cable Monocrimp RM14M30K 26-24 18-16 Machined (3) Part number Male AWG see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 4 Note: all dimensions are in mm Electrical Characteristics UTO 104 Derating Curves Current (A) UL 10A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 13A 150V 2.5kV 3 30 28 25 Test conditions 23 Contact used: Machined contacts Wires used: 1.31mm 15 20 18 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 39 UTO Series | Connector 103W3 (Shell size 10, 3x#16 + 3x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 43 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number Male insert Female insert 96h UT00103W3PH UT00103W3SH IP68 & IP69K 96h UT00103W3PH6 UT00103W3SH6 IP67, IP68 & IP69K 48h UT06103W3PH UT06103W3SH IP67, IP68 & IP69K 96h UT06103W3PH02(Black) UT06103W3SH02(Black) IP67 48h UT07103W3PH UT07103W3SH IP68 & IP69K 48h UT07103W3PH6 UT07103W3SH6 IP67 96h UT07103W3PH01 UT07103W3SH01 IP68 & IP69K 96h UT07103W3PH601 UT07103W3SH601 Plug Jam nut receptacle Backshells 40 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 3/6 UT010JCS UT010JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 5/8 UT010JCSL UT010JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL Metal cable clamp with strain relief (Fig.5) - 5 Metal shrink boot adaptor (Fig.6) - - UT010AD Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN UT010AC 5A/40V per IEC 61984 UTO Series | Connector 103W3 (Shell size 10, 3x#16 + 3x#20) Dimensions Square Flange - UTO0 36 maxi Plug - UTO6 23.8 11.3 35 maxi 21.8 Male 6 O 20 Male Female 1.6 Female 18.2 25.2 maxi 27 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 27 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 14.2 Rear mounting O 17.3 Female 17.9 33 maxi 22.2 18.2 16.5 18.2 O 14.9 Male .4 17 Backshells (for Mated Connector Length: See Page 153) Long version - 61.1 Long version - 61.1 31.0 Fig. 1 Fig. 2 21.6 24.7 O 21.0 Short version - 49.1 O 16.3 Short version - 49.1 Fig. 6 Fig. 5 48.0 Short version - 60.1 Long version - 71.1 Long version - 71.1 60.6 30.0 Short version - 59.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 41 UTO Series | Connector 103W3 (Shell size 10, 3x#16 + 3x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT010DCG* UTG610DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Crimp Tooling (without Shandles) Contacts Part number / Neoprene Part number / Polyamide 6.6 UTFD12B SMSPKE0 See page 182 for more information Extraction Tool #16 Extraction Tool #20 Part number Part number RX2025GE1 RX20D44 Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts RM/RC 24W3K(1) S20RCM S20RCM S20RCM S20SCM20 S20SCM20 Standard contacts RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + * For dustcap without chain, skip "G", e.g. UT010DC 42 Handle = Head Complete set 5A/40V per IEC 61984 UTO Series | Connector 103W3 (Shell size 10, 3x#16 + 3x#20) Contacts Female Max wire O Max insulator O Machined 30-28 26-24 22-20 22-20 20-16 16-14 RM28M1K(1) RM24M9K(1) RM20M13K(1) RM20M12K(1) RM16M23K(1) RM14M30K(1) RC28M1K(1) RC24M9K(1) RC20M13K(1) RC20M12K(1) RC16M23K(1) RC14M30K(1) 0.55 0.80 1.15 1.15 1.80 2.30 1.00 1.60 1.80 2.20 3.20 3.20 Stamped & formed reeled contacts 26-24 22-20 18-16 18-16 14 SM24M1TK6(1)(2) SM20M1TK6(1)(2) SM16M1TK6(1)(2) SM16M11TK6(1)(2) SM14M1TK6(1)(2) SC24M1TK6(1)(2) SC20M1TK6(1)(2) SC16M1TK6(1)(2) SC16M11TK6(1)(2) SC14M1TK6(1)(2) - 0.90-1.60 1.20-2.10 3.20 3.00 3.20 - RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - AWG PCB See note (2) for loose piece Machined (3) Cable Multipiece Coaxial Part number Male Contact type Crimp #16 Cable Monocrimp Twisted pair Multipiece see pages 131, 168 to 174 Twisted pair Monocrimp RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - 6 #20 26-24 22-20 20-18 RM24W3K RM20W3K RM18W3K RC24W3K RC20W3K RC18W3K 0.80 1.15 1.30 1.60 1.60 2.10 Stamped & formed reeled contacts 26-24 26-24 22-20 22-20 SM24W3TK6(1)(2) SM24W3S26(1)(2) SM20W3TK6(1)(2) SM20W3S26(1)(2) SC24W3TK6(1)(2) SC24W3S25(1)(2) SC20W3TK6(1)(2) SC20W3S25(1)(2) - 0.90-1.60 0.90-1.60 1.20-2.10 1.20-2.10 - RMW5016K RCW5016K - - Crimp Machined PCB See note (2) for loose piece Machined (3) Note: all dimensions are in mm (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 or SM24WL3S26 (3): For dimensions see page 132 Electrical Characteristics UTO 103W3 Derating Curves Current (A) UL 5A 250V UL94 V-0 CSA 5A 200V UL94 V-0 IEC 5A 40V 1.5kV 3 30 28 Test conditions 25 23 20 18 Contact used: Machined contacts Wires used: 1.310mm 0.518mm 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 43 UTO Series | Connector 106 (Shell size 10, 6x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 47 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W0106PH UT0W0106SH IP68 & IP69K 96h UT0W0106PH6 UT0W0106SH6 IP67, IP68 & IP69K 48h UT0W6106PH UT0W6106SH IP67, IP68 & IP69K 96h UT0W6106PH02(Black) UT0W6106SH02(Black) IP67 48h UT0W7106PH UT0W7106SH IP68 & IP69K 48h UT0W7106PH6 UT0W7106SH6 IP67 96h UT0W7106PH01 UT0W7106SH01 IP68 & IP69K 96h UT0W7106PH601 UT0W7106SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 44 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 3/6 UT010JCS UT010JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 5/8 UT010JCSL UT010JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 4/6.5 UT0S10JCS UT0S10JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 5/8.5 UT0S10JCSL UT0S10JCL Metal cable clamp with strain relief (Fig.5) - 5 Metal shrink boot adaptor (Fig.6) - - UT010AD Metal right angle cable clamp with strain relief nut (Fig.7) - 4/10 UT010LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 4/8.8 UT0S10JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 4/10 UT010JCPGN UT010AC 7A/80V per IEC 61984 UTO Series | Connector 106 (Shell size 10, 6x#20) Dimensions Square Flange - UTO0 33.3 maxi Plug - UTO6 23.8 11.3 33 maxi 21.8 Male 6 O 20 Male Female 1.6 Female 18.2 25.2 maxi 25.5 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 27 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 14.2 Rear mounting O 17.3 Female 17.9 33 maxi 22.2 18.2 16.5 18.2 O 14.9 Male .4 17 Backshells (for Mated Connector Length: See Page 153) Long version - 61.1 Long version - 61.1 31.0 Fig. 1 Fig. 2 21.6 24.7 O 21.0 Short version - 49.1 O 16.3 Short version - 49.1 Fig. 6 Fig. 5 48.0 Short version - 60.1 Long version - 71.1 Long version - 71.1 60.6 30.0 Short version - 59.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 45 UTO Series | Connector 106 (Shell size 10, 6x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT010DCG* UTG610DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD12B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT024DC 46 7A/80V per IEC 61984 UTO Series | Connector 106 (Shell size 10, 6x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 6 Note: all dimensions are in mm Electrical Characteristics UTO 106 Derating Curves Current (A) UL 5A 250V UL94 V-0 CSA 4A 250V UL94 V-0 IEC 7A 80V 1.5kV 3 14 12 Test conditions 10 8 Contact used: Machined contacts Wires used: 0.518mm 6 4 2 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 47 UTO Series | Connector 147 (Shell size 14, 6 + ground, 7x#16) WITH OR SINGLE WIRE SEALING (1) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 51 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 IP68 & IP69K Part number Male insert Female insert 96h UT00147PH UT00147SH 96h UT00147PH6 UT00147SH6 (1) UT06147SH(1) IP67, IP68 & IP69K 48h UT06147PH IP67, IP68 & IP69K 96h UT06147PH02(1) IP67 48h UT07147PH(1) UT07147SH(1) IP68 & IP69K 48h UT07147PH6(1) UT07147SH6(1) IP67 96h UT07147PH01(1) UT07147SH01(1) IP68 & IP69K 96h UT07147PH601(1) UT07147SH601(1) Plug Jam nut receptacle (Black) UT06147SH02(1) (Black) (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN147PH Backshells 48 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT014JCS UT014JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT014JCSL UT014JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL Metal cable clamp with strain relief (Fig.5) - 10 Metal shrink boot adaptor (Fig.6) - - UT014AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN UT014AC 16A/150V per IEC 61984 UTO Series | Connector 147 (Shell size 14, 6 + ground, 7x#16) Dimensions Square Flange - UTO0 33.3 maxi Plug - UTO6 33 maxi 28.6 11.3 29.3 Male Male O 26.8 6 Female 1.6 Female 25.5 maxi 23.0 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 35 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 21.5 Rear mounting O 25 Female 17.9 33 maxi 30.2 23.0 24.1 23.0 O 22.1 Male .5 25 Backshells (for Mated Connector Length: See Page 153) 9.5 O 29.8 Short version - 53.1 O 29.8 Short version - 52.1 52.0 GN plastic GJC plastic 34.0 Short version - 65.1 Short version - 65.1 O 27.0 Fig. 2 27.4 Fig. 1 24.7 Long version - 69.1 O 22.5 Long version - 68.1 Fig. 6 Fig. 5 52.0 36.5 67.7 Long version - 81.1 Fig. 3 Long version - 81.1 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 49 UTO Series | Connector 147 (Shell size 14, 6 + ground, 7x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT014DCG* UTG614DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD14B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT014DC 50 = Head Complete set 16A/150V per IEC 61984 UTO Series | Connector 147 (Shell size 14, 6 + ground, 7x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 6 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 147 Derating Curves Current (A) 30 UL 10A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 16A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 51 UTO Series | Connector 128 (Shell size 12, 8x#16) WITH OR SINGLE WIRE SEALING (1) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 55 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 IP68 & IP69K Part number* Male insert Female insert 96h UT00128PH UT00128SH 96h UT00128PH6 UT00128SH6 (1) UT06128SH(1) IP67, IP68 & IP69K 48h UT06128PH IP67, IP68 & IP69K 96h UT06128PH02(1) IP67 48h UT07128PH(1) UT07128SH(1) IP68 & IP69K 48h UT07128PH6(1) UT07128SH6(1) IP67 96h UT07128PH01(1) UT07128SH01(1) IP68 & IP69K 96h UT07128PH601(1) UT07128SH601(1) Plug Jam nut receptacle * Other discrimination keying option, see page 182 (Black) UT06128SH02(1) (Black) (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN128PH Backshells 52 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT012JCS UT012JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT012JCSL UT012JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S12JCS UT0S12JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S12JCSL UT0S12JCL Metal cable clamp with strain relief (Fig.5) - 8.2 UT012AC Metal shrink boot adaptor (Fig.6) - - UT012AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/12 UT012LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 04/11.9 UT0S12JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 04/11.9 UT012JCPGN 10A/125V per IEC 61984 UTO Series | Connector 128 (Shell size 12, 8x#16) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 26.2 26.1 Male O 23.6 Male Female 1.6 25.5 maxi 20.6 25.2 maxi Jam Nut - UTO7 34 maxi 8 Female Panel Cut Out 32 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 18.4 Rear mounting O 21.8 Female 17.9 33 maxi 27 20.6 21.0 20.6 O 18.9 Male .2 22 Backshells (for Mated Connector Length: See Page 153) 10.7 O 25.4 Short version - 50.1 O 25.4 Short version - 49.1 49.9 GN plastic GJC plastic 31.5 Short version - 62.1 O 27.0 Fig. 2 25.0 Fig. 1 24.7 Long version - 63.1 O 19.4 Long version - 62.1 Short version - 62.1 Fig. 5 Fig. 6 50.0 33.5 62.7 Long version - 75.1 Fig. 3 Long version - 75.1 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 53 UTO Series | Connector 128 (Shell size 12, 8x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT012DCG* UTG612DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD13B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT012DC 54 = Head Complete set 10A/125V per IEC 61984 UTO Series | Connector 128 (Shell size 12, 8x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 (1)(2) RM14M30K RC14M30K (1)(2) 8 26-24 SM24M1TK6 SC24M1TK6 - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 128 Derating Curves Current (A) 30 UL 10A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 10A 125V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 55 UTO Series | Connector 148 (Shell size 14, 4x#12 + 4x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 59 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number Male insert Female insert 96h UT00148PH UT00148SH IP68 & IP69K 96h UT00148PH6 UT00148SH6 IP67, IP68 & IP69K 48h UT06148PH UT06148SH IP67, IP68 & IP69K 96h UT06148PH02(Black) UT06148SH02(Black) IP67 48h UT07148PH UT07148SH IP68 & IP69K 48h UT07148PH6 UT071482SH6 IP67 96h UT071482PH01 UT07148SH01 IP68 & IP69K 96h UT07148PH601 UT07148SH601 Plug Jam nut receptacle Backshells 56 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT014JCS UT014JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT014JCSL UT014JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL Metal cable clamp with strain relief (Fig.5) - 10 Metal shrink boot adaptor (Fig.6) - - UT014AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN UT014AC 17A/230V per IEC 61984 UTO Series | Connector 148 (Shell size 14, 4x#12 + 4x#16) Dimensions Square Flange - UTO0 33.3 maxi Plug - UTO6 35 maxi 28.6 11.3 29.3 Male O 26.8 Male Female 33 maxi 23.0 32 maxi Jam Nut - UTO7 34 maxi 8 Female 1.6 Panel Cut Out 35 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 21.5 Rear mounting O 25 Female 17.9 33 maxi 30.2 23.0 24.1 23.0 O 22.1 Male .5 25 Backshells (for Mated Connector Length: See Page 153) Long version - 68.1 Long version - 69.1 34.0 Fig. 1 Fig. 2 27.4 24.7 O 27.0 Short version - 53.1 O 22.5 Short version - 52.1 Fig. 6 Fig. 5 52.0 Short version - 65.1 Long version - 81.1 Long version - 81.1 67.7 36.5 Short version - 65.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 57 UTO Series | Connector 148 (Shell size 14, 4x#12 + 4x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT014DCG* UTG614DCG* SHANDLES SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD14B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX20D44 Crimp Tooling #12 Part number Hand Tool M317 Part number positioner + locator setting VGE10078A Ci Crimp T li (without Shandles) Tooling Contacts RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts + 51060210924 Handle 58 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES Part number Extraction Tool * For dustcap without chain, skip "G", e.g. UT014DC Part number of head Contact size = Head Complete set 17A/230V per IEC 61984 UTO Series | Connector 148 (Shell size 14, 4x#12 + 4x#16) Contacts #16 Contact type Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece AWG Male Female Max wire O Max insulator O 30-28 RM28M1K(1) RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 (1)(2) RM14M30K RC14M30K (1)(2) 26-24 SM24M1TK6 SC24M1TK6 - 0.90-1.60 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 - 3.20 14 SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1)(2) SM14M1TK6 SC14M1TK6 Cable Multipiece RMDXK10D28 RCDXK1D28 - - Cable Monocrimp RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Twisted pair Multipiece 8 22-20 18-16 Coaxial Part number see pages 131, 168 to 174 Twisted pair Monocrimp Crimp #12 Machined 22 82911457NA 82911456A 0.87 20 82911459NA 82911458A 1.12 18 82911461NA 82911460A 1.42 16 82911463NA 82911462A 1.72 14 82911465NA 82911464A 2.22 12 82911467NA 82911466A 2.82 (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 4.90 Note: all dimensions are in mm Electrical Characteristics UTO 148 Derating Curves Current (A) 45 UL 25A 250V UL94 V-0 CSA 17A 250V UL94 V-0 IEC 17A 230V 1.5kV 3 40 35 Test conditions Contact used: Machined contacts Wires used: 1.31mm 3.30mm 30 25 20 15 10 5 0 0 25 45 65 85 105 125 Ambient Operating Temperature (C) Current use Limited use Not recommended use 59 UTO Series | Connector 1210 (Shell size 12, 10x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 63 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W01210PH UT0W01210SH IP68 & IP69K 96h UT0W01210PH6 UT0W01210SH6 IP67, IP68 & IP69K 48h UT0W61210PH UT0W61210SH IP67, IP68 & IP69K 96h UT0W61210PH02(Black) UT0W61210SH02(Black) IP67 48h UT0W71210PH UT0W71210SH IP68 & IP69K 48h UT0W71210PH6 UT0W71210SH6 IP67 96h UT0W71210PH01 UT0W71210SH01 IP68 & IP69K 96h UT0W71210PH601 UT0W71210SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 60 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT012JCS UT012JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT012JCSL UT012JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S12JCS UT0S12JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S12JCSL UT0S12JCL Metal cable clamp with strain relief (Fig.5) - 8.2 UT012AC Metal shrink boot adaptor (Fig.6) - - UT012AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/12 UT012LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 04/11.9 UT0S12JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 04/11.9 UT012JCPGN 6A/40V per IEC 61984 UTO Series | Connector 1210 (Shell size 12, 10x#20) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 26.2 26.1 Male O 23.6 Male Female 1.6 Female 25.5 maxi 20.6 25.2 maxi 10 Jam Nut - UTO7 34 maxi Panel Cut Out 32 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 18.4 Rear mounting O 21.8 Female 17.9 33 maxi 27 20.6 21.0 20.6 O 18.9 Male .2 22 Backshells (for Mated Connector Length: See Page 153) Long version - 62.1 Long version - 63.1 31.5 Fig. 1 Fig. 2 25.0 24.7 O 27.0 Short version - 50.1 O 19.4 Short version - 49.1 Fig. 6 Fig. 5 50.0 Short version - 62.1 Long version - 75.1 Long version - 75.1 62.7 33.5 Short version - 62.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 61 UTO Series | Connector 1210 (Shell size 12, 10x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT012DCG* UTG612DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD13B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT012DC 62 6A/40V per IEC 61984 UTO Series | Connector 1210 (Shell size 12, 10x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG SM20W3S26 SC20W3S25 10 Machined (3) - RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UT0 1210 Derating Curves Current (A) UL 5A 250V UL94 V-0 CSA 4A 250V UL94 V-0 IEC 6A 40V 1.5kV 3 12 10 Test conditions Contact used: Machined contacts Wires used: 0.518mm 8 6 4 2 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 63 UTO Series | Connector 1412 (Shell size 14, 12x#16) WITH OR SINGLE WIRE SEALING (1) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 67 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 IP68 & IP69K Part number* Male insert Female insert 96h UT001412PH UT001412SH 96h UT001412PH6 UT001412SH6 (1) UT061412SH(1) IP67, IP68 & IP69K 48h UT061412PH IP67, IP68 & IP69K 96h UT061412PH02(1) IP67 48h UT071412PH(1) UT071412SH(1) IP68 & IP69K 48h UT071412PH6(1) UT071412SH6(1) IP67 96h UT071412PH01(1) UT071412SH01(1) IP68 & IP69K 96h UT071412PH601(1) UT071412SH601(1) Plug Jam nut receptacle * Other discrimination keying option, see page 182 (Black) UT061412SH02(1) (Black) (1): For single wire sealing solution please add GN or GJC after UT06 or UT07. Eg UT07GN1412PH Backshells 64 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT014JCS UT014JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT014JCSL UT014JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL Metal cable clamp with strain relief (Fig.5) - 10 Metal shrink boot adaptor (Fig.6) - - UT014AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN UT014AC 10A/150V per IEC 61984 UTO Series | Connector 1412 (Shell size 14, 12x#16) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 28.6 29.3 Male O 26.8 Male Female 1.6 Female 25.5 maxi 23.0 25.2 maxi Jam Nut - UTO7 34 maxi 12 Panel Cut Out 35 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 21.5 Rear mounting O 25 Female 17.9 33 maxi 30.2 23.0 24.1 23.0 O 22.1 Male .5 25 Backshells (for Mated Connector Length: See Page 153) 9.5 O 29.8 Short version - 53.1 O 29.8 Short version - 52.1 52.0 GN plastic GJC plastic 34.0 Short version - 65.1 Short version - 65.1 O 27.0 Fig. 2 27.4 Fig. 1 24.7 Long version - 69.1 O 22.5 Long version - 68.1 Fig. 6 Fig. 5 52.0 36.5 67.7 Long version - 81.1 Fig. 3 Long version - 81.1 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 65 UTO Series | Connector 1412 (Shell size 14, 12x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT014DCG* UTG614DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD14B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT014DC 66 = Head Complete set 10A/150V per IEC 61984 UTO Series | Connector 1412 (Shell size 14, 12x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 12 Note: all dimensions are in mm Electrical Characteristics UTO 1412 Derating Curves Current (A) 30 UL 10A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 10A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 67 UTO Series | Connector 1492 (Shell size 14, 12x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 71 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT001492PH UT001492SH IP68 & IP69K 96h UT001492PH6 UT001492SH6 IP67, IP68 & IP69K 48h UT0614912PH UT061492SH IP67, IP68 & IP69K 96h UT0614192PH02(Black) UT061492SH02(Black) IP67 48h UT071492PH UT071492SH IP68 & IP69K 48h UT071492PH6 UT071492SH6 IP67 96h UT071492PH01 UT071492SH01 IP68 & IP69K 96h UT071492PH601 UT071492SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 68 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT014JCS UT014JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT014JCSL UT014JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL Metal cable clamp with strain relief (Fig.5) - 10 Metal shrink boot adaptor (Fig.6) - - UT014AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN UT014AC 10A/150V per IEC 61984 UTO Series | Connector 1492 (Shell size 14, 12x#16) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 28.6 29.3 Male O 26.8 Male Female 1.6 Female 25.5 maxi 23.0 25.2 maxi Jam Nut - UTO7 34 maxi 12 Panel Cut Out 35 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 21.5 Rear mounting O 25 Female 17.9 33 maxi 30.2 23.0 24.1 23.0 O 22.1 Male .5 25 Backshells (for Mated Connector Length: See Page 153) Long version - 68.1 Long version - 69.1 34.0 Fig. 1 Fig. 2 27.4 24.7 O 27.0 Short version - 53.1 O 22.5 Short version - 52.1 Fig. 6 Fig. 5 52.0 Short version - 65.1 Long version - 81.1 Long version - 81.1 67.7 36.5 Short version - 65.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 69 UTO Series | Connector 1492 (Shell size 14, 12x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT014DCG* UTG614DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD14B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT014DC 70 = Head Complete set 10A/150V per IEC 61984 UTO Series | Connector 1492 (Shell size 14, 12x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 12 Note: all dimensions are in mm Electrical Characteristics UTO 1492 Derating Curves Current (A) 30 UL 10A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 10A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 71 UTO Series | Connector 1419 (Shell size 14, 19x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 75 Drilling pattern see page 176 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W01419PH UT0W01419SH IP68 & IP69K 96h UT0W01419PH6 UT0W01419SH6 IP67, IP68 & IP69K 48h UT0W61419PH UT0W61419SH IP67, IP68 & IP69K 96h UT0W61419PH02(Black) UT0W61419SH02(Black) IP67 48h UT0W71419PH UT0W71419SH IP68 & IP69K 48h UT0W71419PH6 UT0W71419SH6 IP67 96h UT0W71419PH01 UT0W71419SH01 IP68 & IP69K 96h UT0W71419PH601 UT0W71419SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 72 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 06/10 UT014JCS UT014JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 08/12 UT014JCSL UT014JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 07/10.5 UT0S14JCS UT0S14JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 08/12.5 UT0S14JCSL UT0S14JCL Metal cable clamp with strain relief (Fig.5) - 10 Metal shrink boot adaptor (Fig.6) - - UT014AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/14 UT014LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/13.5 UT0S14JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/13.5 UT014JCPGN UT014AC 5A/40V per IEC 61984 UTO Series | Connector 1419 (Shell size 14, 19x#20) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 28.6 29.3 Male O 26.8 Male Female 1.6 Female 25.5 maxi 23.0 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 35 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 19 Front mounting O 21.5 Rear mounting O 25 Female 17.9 33 maxi 30.2 23.0 24.1 23.0 O 22.1 Male .5 25 Backshells (for Mated Connector Length: See Page 153) Long version - 68.1 Long version - 69.1 34.0 Fig. 1 Fig. 2 27.4 24.7 O 27.0 Short version - 53.1 O 22.5 Short version - 52.1 Fig. 6 Fig. 5 52.0 Short version - 65.1 Long version - 81.1 Long version - 81.1 67.7 36.5 Short version - 65.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 73 UTO Series | Connector 1419 (Shell size 14, 19x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT014DCG* UTG614DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD14B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT014DC 74 5A/40V per IEC 61984 UTO Series | Connector 1419 (Shell size 14, 19x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 Note: all dimensions are in mm 19 Electrical Characteristics UTO 1419 Derating Curves Current (A) UL 5A 250V UL94 V-0 CSA 4A 250V UL94 V-0 IEC 5A 40V 1.5kV 3 12 10 Test conditions Contact used: Machined contacts Wires used: 0.518mm 8 6 4 2 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 75 UTO Series | Connector 1619 (Shell size 16, 19x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 79 Drilling pattern see page 177 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT001619PH UT001619SH IP68 & IP69K 96h UT001619PH6 UT001619SH6 IP67, IP68 & IP69K 48h UT061619PH UT061619SH IP67, IP68 & IP69K 96h UT061619PH02(Black) UT061619SH02(Black) IP67 48h UT071619PH UT071619SH IP68 & IP69K 48h UT071619PH6 UT071619SH6 IP67 96h UT071619PH01 UT071619SH01 IP68 & IP69K 96h UT071619PH601 UT071619SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 76 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 9.5/14 UT016JCS UT016JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 11.5/18 UT016JCSL UT016JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S16JCS UT0S16JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S16JCSL UT0S16JCL Metal cable clamp with strain relief (Fig.5) - 13 UT016AC Metal shrink boot adaptor (Fig.6) - - UT016AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/16 UT016LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S16JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT016JCPGN 9A/150V per IEC 61984 UTO Series | Connector 1619 (Shell size 16, 19x#16) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 31.0 32.45 Male O 30.0 Male Female 1.6 Female 25.5 maxi 24.6 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 38.1 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 19 Front mounting O 24.6 Rear mounting O 28.1 Female 17.9 33 maxi 33.3 24.6 27.2 24.6 O 25.3 Male .3 28 Backshells (for Mated Connector Length: See Page 153) Long version - 74.1 Long version - 80.1 34.0 Fig. 1 Fig. 2 29.4 27 O 30.0 Short version - 69.1 O 25.8 Short version - 63.1 Fig. 6 Fig. 5 55.0 Short version - 83.1 Long version - 84.1 Long version - 94.1 73.1 39.5 Short version - 73.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 77 UTO Series | Connector 1619 (Shell size 16, 19x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT016DCG* UTG616DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD15B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT016DC 78 = Head Complete set 9A/150V per IEC 61984 UTO Series | Connector 1619 (Shell size 16, 19x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 19 Note: all dimensions are in mm Electrical Characteristics UTO 1619 Derating Curves Current (A) UL 9A 500V UL94 V-0 CSA 6A 500V UL94 V-0 IEC 9A 150V 2.5kV 3 28 Test conditions Contact used: Machined contacts Wires used: 1.31mm 25 20 15 10 5 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 79 UTO Series | Connector 1823 (Shell size 18, 23x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 83 Drilling pattern see page 177 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT001823PH UT001823SH IP68 & IP69K 96h UT001823PH6 UT001823SH6 IP67, IP68 & IP69K 48h UT061823PH UT061823SH IP67, IP68 & IP69K 96h UT061823PH02(Black) UT061823SH02(Black) IP67 48h UT071823PH UT071823SH IP68 & IP69K 48h UT071823PH6 UT071823SH6 IP67 96h UT071823PH01 UT071823SH01 IP68 & IP69K 96h UT071823PH601 UT071823SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 80 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 9.5/14 UT018JCS UT018JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 11.5/18 UT018JCSL UT018JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S18JCS UT0S18JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S18JCSL UT0S18JCL Metal cable clamp with strain relief (Fig.5) - 16.0 UT018AC Metal shrink boot adaptor (Fig.6) - - UT018AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT018LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S18JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT018JCPGN 8A/150V per IEC 61984 UTO Series | Connector 1823 (Shell size 18, 23x#16) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 33.3 35.2 Male O 33.3 Male Female 1.6 Female 25.5 maxi 26.9 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 41.3 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Male Front mounting O 27.8 Rear mounting O 31.3 Female 17.9 33 maxi 36.5 26.9 30.3 26.9 O 28.4 23 .8 31 Backshells (for Mated Connector Length: See Page 153) Long version - 76.6 Long version - 82.6 31.4 Fig. 1 Fig. 2 35.2 27 O 33.3 Short version - 72.1 O 33.3 Short version - 66.1 Fig. 6 Fig. 5 60.0 Short version - 86.1 Long version - 86.6 Long version - 96.6 77.2 46.0 Short version - 76.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 81 UTO Series | Connector 1823 (Shell size 18, 23x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT018DCG* UTG618DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD16B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT018DC 82 = Head Complete set 8A/150V per IEC 61984 UTO Series | Connector 1823 (Shell size 18, 23x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 23 Note: all dimensions are in mm Electrical Characteristics UTO 1823 Derating Curves Current (A) 30 UL 8A 500V UL94 V-0 CSA 7A 500V UL94 V-0 IEC 8A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 83 UTO Series | Connector 1626 (Shell size 16, 26x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 87 Drilling pattern see page 177 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W01626PH UT0W01626SH IP68 & IP69K 96h UT0W01626PH6 UT0W01626SH6 IP67, IP68 & IP69K 48h UT0W61626PH UT0W61626SH IP67, IP68 & IP69K 96h UT0W61626PH02(Black) UT0W61626SH02(Black) IP67 48h UT0W71626PH UT0W71626SH IP68 & IP69K 48h UT0W71626PH6 UT0W71626SH6 IP67 96h UT0W71626PH01 UT0W71626SH01 IP68 & IP69K 96h UT0W71626PH601 UT0W71626SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 84 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 9.5/14 UT016JCS UT016JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 11.5/18 UT016JCSL UT016JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S16JCS UT0S16JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S16JCSL UT0S16JCL Metal cable clamp with strain relief (Fig.5) - 13 UT016AC Metal shrink boot adaptor (Fig.6) - - UT016AD Metal right angle cable clamp with strain relief nut (Fig.7) - 6.5/16 UT016LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S16JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT016JCPGN 4A/40V per IEC 61984 UTO Series | Connector 1626 (Shell size 16, 26x#20) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 31.0 32.4 Male O 30.0 Male Female 1.6 Female 25.5 maxi 24.6 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 38.1 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 24.6 Rear mounting O 28.1 Female 17.9 33 maxi 33.3 24.6 27.2 24.6 O 25.3 Male .3 28 26 Backshells (for Mated Connector Length: See Page 153) Long version - 74.1 Long version - 80.1 34.0 Fig. 1 Fig. 2 29.4 27 O 30.0 Short version - 69.1 O 25.8 Short version - 63.1 Fig. 6 Fig. 5 55.0 Short version - 83.1 Long version - 84.1 Long version - 94.1 73.1 39.5 Short version - 73.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 85 UTO Series | Connector 1626 (Shell size 16, 26x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT016DCG* UTG616DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD15B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT016DC 86 4A/40V per IEC 61984 UTO Series | Connector 1626 (Shell size 16, 26x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 Note: all dimensions are in mm 26 Electrical Characteristics UTO 1626 Derating Curves Current (A) 10 UL 4A 250V UL94 V-0 CSA 3A 250V UL94 V-0 IEC 4A 40V 1.5kV 3 9 8 Test conditions Contact used: Machined contacts Wires used: 0.518mm 7 6 5 4 3 2 1 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 87 UTO Series | Connector 2028 (Shell size 20, 28x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 91 Drilling pattern see page 178 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT002028PH UT002028SH IP68 & IP69K 96h UT002028PH6 UT002028SH6 IP67, IP68 & IP69K 48h UT062028PH UT062028SH IP67, IP68 & IP69K 96h UT062028PH02(Black) UT062028SH02(Black) IP67 48h UT072028PH UT072028SH IP68 & IP69K 48h UT072028PH6 UT072028SH6 IP67 96h UT072028PH01 UT072028SH01 IP68 & IP69K 96h UT072028PH601 UT072028SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 88 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT020JCS UT020JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT020JCSL UT020JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S20JCS UT0S20JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S20JCSL UT0S20JCL Metal cable clamp with strain relief (Fig.5) - 16.0 UT020AC Metal shrink boot adaptor (Fig.6) - - UT020AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT020LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S20JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT020JCPGN 7A/150V per IEC 61984 UTO Series | Connector 2028 (Shell size 20, 28x#16) Dimensions Square Flange - UTO0 34.75 maxi 14.5 Plug - UTO6 33 maxi 36.5 38.8 Male O 36.5 Male Female 2.4 Female 27.5 maxi 29.3 29 maxi Jam Nut - UTO7 39 maxi Panel Cut Out 46.0 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 30.9 Rear mounting O 34.5 Female 22.7 39 maxi 39.7 29.3 33.5 29.3 O 31.6 Male .8 34 28 Backshells (for Mated Connector Length: See Page 153) Long version - 84.6 Long version - 91.6 32.0 Fig. 1 Fig. 2 35.2 27 O 36.5 Short version - 81.8 O 32.5 Short version - 74.8 Fig. 6 Fig. 5 58.0 Short version - 97.3 Long version - 98.1 Long version - 107.1 84.6 47.0 Short version - 88.3 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 89 UTO Series | Connector 2028 (Shell size 20, 28x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT020DCG* UTG620DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD17B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT028DC 90 = Head Complete set 7A/150V per IEC 61984 UTO Series | Connector 2028 (Shell size 20, 28x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 2028 Derating Curves Current (A) 30 UL 5A 500V UL94 V-0 CSA 3A 500V UL94 V-0 IEC 7A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 91 28 UTO Series | Connector 2030 (Shell size 20, 30x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Drilling pattern see page 178 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT002030PH UT002030SH IP68 & IP69K 96h UT002030PH6 UT002030SH6 IP67, IP68 & IP69K 48h UT062030PH UT062030SH IP67, IP68 & IP69K 96h UT062030PH02(Black) UT062030SH02(Black) IP67 48h UT072030PH UT072030SH IP68 & IP69K 48h UT072030PH6 UT072030SH6 IP67 96h UT072030PH01 UT072030SH01 IP68 & IP69K 96h UT072030PH601 UT072030SH601 Plug Contacts supplied separately see page 95 Jam nut receptacle * Other possible discrimination, see page 180 Backshells 92 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT020JCS UT020JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT020JCSL UT020JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S20JCS UT0S20JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S20JCSL UT0S20JCL Metal cable clamp with strain relief (Fig.5) - 16.0 Metal shrink boot adaptor (Fig.6) - - UT020AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT020LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S20JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT020JCPGN UT020AC 7A/150V per IEC 61984 UTO Series | Connector 2030 (Shell size 20, 30x#16) Dimensions Square Flange - UTO0 34.75 maxi 14.5 Plug - UTO6 33 maxi 36.5 38.8 Male O 36.5 Male Female 2.4 Female 27.5 maxi 29.3 29 maxi Jam Nut - UTO7 39 maxi Panel Cut Out 46.0 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 30.9 Rear mounting O 34.5 Female 22.7 39 maxi 39.7 29.3 33.5 29.3 O 31.6 Male .8 34 30 Backshells (for Mated Connector Length: See Page 153) Long version - 84.6 Long version - 91.6 32.0 Fig. 1 Fig. 2 35.2 27 O 36.5 Short version - 81.8 O 32.5 Short version - 74.8 Fig. 6 Fig. 5 58.0 Short version - 97.3 Long version - 98.1 Long version - 107.1 84.6 47.0 Short version - 88.3 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 93 UTO Series | Connector 2030 (Shell size 20, 30x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT020DCG* UTG620DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD17B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT028DC 94 = Head Complete set 7A/150V per IEC 61984 UTO Series | Connector 2030 (Shell size 20, 30x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm 30 Electrical Characteristics UTO 2030 Derating Curves Current (A) 30 UL 5A 500V UL94 V-0 CSA 3A 500V UL94 V-0 IEC 7A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 95 UTO Series | Connector 1832 (Shell size 18, 32x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 99 Drilling pattern see page 177 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W01832PH UT0W01832SH IP68 & IP69K 96h UT0W01832PH6 UT0W01832SH6 IP67, IP68 & IP69K 48h UT0W61832PH UT0W61832SH IP67, IP68 & IP69K 96h UT0W61832PH02(Black) UT0W61832SH02(Black) IP67 48h UT0W71832PH UT0W71832SH IP68 & IP69K 48h UT0W71832PH6 UT0W71832SH6 IP67 96h UT0W71832PH01 UT0W71832SH01 IP68 & IP69K 96h UT0W71832PH601 UT0W71832SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 96 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 9.5/14 UT018JCS UT018JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 11.5/18 UT018JCSL UT018JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 10/14.5 UT0S18JCS UT0S18JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 13.5/18 UT0S18JCSL UT0S18JCL Metal cable clamp with strain relief (Fig.5) - 16.0 UT018AC Metal shrink boot adaptor (Fig.6) - - UT018AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT018LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 6.5/16 UT0S18JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 6.5/16 UT018JCPGN 4A/50V per IEC 61984 UTO Series | Connector 1832 (Shell size 18, 32x#20) Dimensions Square Flange - UTO0 33.3 maxi 11.3 Plug - UTO6 33 maxi 33.3 35.2 Male O 33.3 Male Female 1.6 Female 25.5 maxi 26.9 25.2 maxi Jam Nut - UTO7 34 maxi Panel Cut Out 41.3 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 27.8 Rear mounting O 31.3 Female 17.9 33 maxi 36.5 26.9 30.3 26.9 O 28.4 Male .8 31 Backshells (for Mated Connector Length: See Page 153) Long version - 76.6 Long version - 82.6 31.4 Fig. 1 Fig. 2 35.2 27 O 33.3 Short version - 72.1 O 33.3 Short version - 66.1 32 Fig. 6 Fig. 5 60.0 Short version - 86.1 Long version - 86.6 Long version - 96.6 77.2 46.0 Short version - 76.1 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 97 UTO Series | Connector 1832 (Shell size 18, 32x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT018DCG* UTG618DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD16B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT018DC 98 4A/50V per IEC 61984 UTO Series | Connector 1832 (Shell size 18, 32x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 Note: all dimensions are in mm 32 Electrical Characteristics UTO 1832 Derating Curves Current (A) 10 UL 4A 250V UL94 V-0 CSA 3A 250V UL94 V-0 IEC 4A 50V 1.5kV 3 8 Test conditions Contact used: Machined contacts Wires used: 0.518mm 6 4 2 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 99 UTO Series | Connector 2235 (Shell size 22, 35x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 103 Drilling pattern see page 178 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT002235PH UT002235SH IP68 & IP69K 96h UT002235PH6 UT002235SH6 IP67, IP68 & IP69K 48h UT062235PH UT062235SH IP67, IP68 & IP69K 96h UT062235PH02(Black) UT062235SH02(Black) IP67 48h UT072235PH UT072235SH IP68 & IP69K 48h UT072235PH6 UT072235SH6 IP67 96h UT072235PH01 UT072235SH01 IP68 & IP69K 96h UT072235PH601 UT072235SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 100 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT022JCS UT022JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT022JCSL UT022JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S22JCS UT0S22JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S22JCSL UT0S22JCL Metal cable clamp with strain relief (Fig.5) - 19.3 UT022AC Metal shrink boot adaptor (Fig.6) - - UT022AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT022LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S22JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT022JCPGN 6A/150V per IEC 61984 UTO Series | Connector 2235 (Shell size 22, 35x#16) Dimensions Square Flange - UTO0 34.75 maxi 14.5 Plug - UTO6 33 maxi 39.7 42 Male 39.5 Male Female 2.4 Female 27.5 maxi 31.7 29 maxi Jam Nut - UTO7 39 maxi Panel Cut Out 49.2 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 34.1 Rear mounting O 37.7 Female 22.7 39 maxi 42.9 31.7 36.7 31.7 O 34.8 Male .9 37 Backshells (for Mated Connector Length: See Page 153) Long version - 88.4 Long version - 95.4 31.0 Fig. 1 Fig. 2 35 41.1 27 O 39.7 Short version - 84.1 O 35.7 Short version - 77.1 Fig. 6 Fig. 5 58.0 Short version - 99.6 Long version - 101.9 Long version - 110.9 91.7 48.0 Short version - 90.6 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 101 UTO Series | Connector 2235 (Shell size 22, 35x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT022DCG* UTG622DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD18B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT022DC 102 = Head Complete set 6A/150V per IEC 61984 UTO Series | Connector 2235 (Shell size 22, 35x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm 35 Electrical Characteristics UTO 2235 Derating Curves Current (A) 30 UL 5A 500V UL94 V-0 CSA 3A 500V UL94 V-0 IEC 6A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 103 UTO Series | Connector 2238 (Shell size 22, 38x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Drilling pattern see page 178 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT002238PH UT002238SH IP68 & IP69K 96h UT002238PH6 UT002238SH6 IP67, IP68 & IP69K 48h UT062238PH UT062238SH IP67, IP68 & IP69K 96h UT062238PH02(Black) UT062238SH02(Black) IP67 48h UT072238PH UT072238SH IP68 & IP69K 48h UT072238PH6 UT072238SH6 IP67 96h UT072238PH01 UT072238SH01 IP68 & IP69K 96h UT072238PH601 UT072238SH601 Plug Contacts supplied separately see page 107 Jam nut receptacle * Other possible discrimination, see page 180 Backshells 104 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT022JCS UT022JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT022JCSL UT022JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S22JCS UT0S22JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S22JCSL UT0S22JCL Metal cable clamp with strain relief (Fig.5) - 19.3 UT022AC Metal shrink boot adaptor (Fig.6) - - UT022AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT022LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S22JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT022JCPGN 6A/150V per IEC 61984 UTO Series | Connector 2238 (Shell size 22, 38x#16) Dimensions Square Flange - UTO0 34.75 maxi 14.5 Plug - UTO6 33 maxi 39.7 42 Male 39.5 Male Female 2.4 Female 27.5 maxi 31.7 29 maxi Jam Nut - UTO7 39 maxi Panel Cut Out 49.2 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 34.1 Rear mounting O 37.7 Female 22.7 39 maxi 42.9 31.7 36.7 31.7 O 34.8 Male .9 37 Backshells (for Mated Connector Length: See Page 153) 31.0 Long version - 88.4 Fig. 1 41.1 27 38 O 39.7 Short version - 84.1 O 35.7 Short version - 77.1 Long version - 95.4 Fig. 2 Fig. 6 Fig. 5 58.0 Short version - 99.6 Long version - 101.9 Long version - 110.9 91.7 48.0 Short version - 90.6 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 105 UTO Series | Connector 2238 (Shell size 22, 38x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT022DCG* UTG622DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD18B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT022DC 106 = Head Complete set 6A/150V per IEC 61984 UTO Series | Connector 2238 (Shell size 22, 38x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm 38 Electrical Characteristics UTO 2238 Derating Curves Current (A) 30 UL 5A 500V UL94 V-0 CSA 3A 500V UL94 V-0 IEC 6A 150V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 107 UTO Series | Connector 2041 (Shell size 20, 41x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 111 Drilling pattern see page 178 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W02041PH UT0W02041SH IP68 & IP69K 96h UT0W02041PH6 UT0W02041SH6 IP67, IP68 & IP69K 48h UT0W62041PH UT0W62041SH IP67, IP68 & IP69K 96h UT0W62041PH02(Black) UT0W62041SH02(Black) IP67 48h UT0W72041PH UT0W72041SH IP68 & IP69K 48h UT0W72041PH6 UT0W72041SH6 IP67 96h UT0W72041PH01 UT0W72041SH01 IP68 & IP69K 96h UT0W72041PH601 UT0W72041SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 108 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT020JCS UT020JC Cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT020JCSL UT020JCL Shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S20JCS UT0S20JC Shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S20JCSL UT0S20JCL Metal cable clamp with strain relief (Fig.5) - 16.0 UT020AC UT020AD Metal shrink boot adaptor (Fig.6) - - Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT020LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S20JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT020JCPGN 8A/80V per IEC 61984 UTO Series | Connector 2041 (Shell size 20, 41x#20) Dimensions Square Flange - UTO0 34.75 maxi 14.5 Plug - UTO6 33 maxi 36.5 38.8 Male O 36.5 Male Female 2.4 Female 27.5 maxi 29.3 29 maxi Jam Nut - UTO7 39 maxi Panel Cut Out 46.0 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 30.9 Rear mounting O 34.5 Female 22.7 39 maxi 39.7 29.3 33.5 29.3 O 31.6 Male .8 34 Backshells (for Mated Connector Length: See Page 153) Long version - 84.6 Long version - 91.6 32.0 Fig. 1 Fig. 2 35.2 27 O 36.5 Short version - 81.8 O 32.5 Short version - 74.8 41 Fig. 6 Fig. 5 58.0 Short version - 97.3 Long version - 98.1 Long version - 107.1 84.6 47.0 Short version - 88.3 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 109 UTO Series | Connector 2041 (Shell size 20, 41x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT020DCG* UTG620DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD17B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT020DC 110 8A/80V per IEC 61984 UTO Series | Connector 2041 (Shell size 20, 41x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics 41 UTO 2041 Derating Curves Current (A) 10 UL 3A 250V UL94 V-0 CSA 2A 250V UL94 V-0 IEC 8A 80V 1.5kV 3 9 8 Test conditions Contact used: Machined contacts Wires used: 0.518mm 7 6 5 4 3 2 1 0 0 20 40 60 80 100 Ambient Operating Temperature (C) Current use Limited use 120 Not recommended use 111 UTO Series | Connector 2448 (Shell size 24, 48x#16) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 115 Drilling pattern see page 183 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT002448PH UT002448SH IP68 & IP69K 96h UT002448PH6 UT002448SH6 IP67, IP68 & IP69K 48h UT062448PH UT062448SH IP67, IP68 & IP69K 96h UT062448PH02(Black) UT062448SH02(Black) IP67 48h UT072448PH UT072448SH IP68 & IP69K 48h UT072448PH6 UT072448SH6 IP67 96h UT072448PH01 UT072448SH01 IP68 & IP69K 96h UT072448PH601 UT072448SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 112 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT024JCS UT024JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT024JCSL UT024JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S24JCS UT0S24JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S24JCSL UT0S24JCL Metal cable clamp with strain relief (Fig.5) - 19.3 UT024AC Metal shrink boot adaptor (Fig.6) - - UT024AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT024LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S24JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT024JCPGN 6A/160V per IEC 61984 UTO Series | Connector 2448 (Shell size 24, 48x#16) Dimensions Square Flange - UTO0 34.75 maxi 15.3 Plug - UTO6 33 maxi 42.8 45.05 Male O 42.6 Male Female 2.4 Female 27.5 maxi 34.9 29 maxi Jam Nut - UTO7 41 maxi Panel Cut Out 53.4 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.9 Front mounting O 37.3 Rear mounting O 40.9 Female 23.6 41 maxi 46.0 34.9 39.9 34.9 O 38.0 Male .2 41 Backshells (for Mated Connector Length: See Page 153) Long version - 92.4 Long version - 99.4 31.0 Fig. 1 Fig. 2 42.4 27 O 42.9 Short version - 89.4 O 38.8 Short version - 82.4 Fig. 6 Fig. 5 48 67.0 Short version - 104.9 Long version - 105.9 Long version - 114.9 91.7 54.5 Short version - 95.9 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 113 UTO Series | Connector 2448 (Shell size 24, 48x#16) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT024DCG* UTG624DCG* SHANDLES TOOLKIT Gasket Dummy Contact #16 Part number / Neoprene Part number / Polyamide 6.6 UTFD19B SMSPKE0 See page 182 for more information Extraction Tool #16 Part number RX2025GE1 Ci Crimp T li (without Shandles) Tooling Contacts Part number of head Contact size RM/RC 28M1K(1) RM/RC 24M9K(1) RM/RC 20M13K(1) RM/RC 20M12K(1) RM/RC 16M23K(1) RM/RC 14M30K(1) SM/SC 24ML1TK6(1) SM/SC 20ML1TK6(1) SM/SC 16ML1TK6(1) SM/SC 14ML1TK6(1) SM/SC 16ML11TK6(1) RMDXK10D28K RCDXK1D28K RM/RC DX60xxD28K RM/RC DXK10D28 + york090 RM/RC DX60xxD28 S16RCM20* S16RCM20* S16RCM20* S16RCM20* S16RCM16* S16RCM14* S16SCM20* S16SCM20* S16SCML1* S16SCML1* S16SCML11* Standard contacts #16 O 1.6mm M10S1J with die set & stop bushing see page 173 to 174 Coaxial contacts (1): Example of plating, for other plating options see page 129 * Heads to be used with handle PN: SHANDLES + Handle * For dustcap without chain, skip "G", e.g. UT024DC 114 = Head Complete set 6A/160V per IEC 61984 UTO Series | Connector 2448 (Shell size 24, 48x#16) Contacts #16 Contact type AWG Crimp Machined Stamped & formed reeled contacts See note (2) for loose piece PCB Coaxial Max wire O Max insulator O RC28M1K(1) 0.55 1.00 26-24 (1) (1) RM24M9K RC24M9K 0.80 1.60 22-20 RM20M13K(1) RC20M13K(1) 1.15 1.80 22-20 (1) RM20M12K (1) RC20M12K 1.15 2.20 20-16 RM16M23K(1) RC16M23K(1) 1.80 3.20 16-14 (1) (1) 2.30 3.20 RM14M30K RC14M30K 26-24 SM24M1TK6(1)(2) SC24M1TK6(1)(2) - 0.90-1.60 22-20 SM20M1TK6(1)(2) SC20M1TK6(1)(2) - 1.20-2.10 18-16 (1)(2) (1)(2) - 3.20 - 3.00 SM14M1TK6 (1)(2) SC14M1TK6 - 3.20 RM20M12E8K(1) RC20M12E84K(1) - - RMDXK10D28 RCDXK1D28 - - RMDX60xxD28 RCDX60xxD28 - - RMDXK10D28 + york090 RCDXK1D28 + york090 - - RMDX60xxD28 RCDX60xxD28 - - Cable Multipiece Twisted pair Multipiece Female RM28M1K(1) 14 Cable Monocrimp Male 30-28 18-16 Machined (3) Part number see pages 131, 168 to 174 Twisted pair Monocrimp SM16M1TK6 SC16M1TK6 SM16M11TK6(1)(2) SC16M11TK6(1)(2) (1)(2) (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20ML1TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 2448 Derating Curves 48 Current (A) 30 UL 5A 500V UL94 V-0 CSA 3A 500V UL94 V-0 IEC 6A 160V 2.5kV 3 28 25 Test conditions Contact used: Machined contacts Wires used: 1.31mm 23 20 18 15 13 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 115 UTO Series | Connector 2255 (Shell size 22, 55x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 119 Drilling pattern see page 183 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W02255PH UT0W02255SH IP68 & IP69K 96h UT0W02255PH6 UT0W02255SH6 IP67, IP68 & IP69K 48h UT0W62255PH UT0W62255SH IP67, IP68 & IP69K 96h UT0W62255PH02(Black) UT0W62255SH02(Black) IP67 48h UT0W72255PH UT0W72255SH IP68 & IP69K 48h UT0W72255PH6 UT0W72255SH6 IP67 96h UT0W72255PH01 UT0W72255SH01 IP68 & IP69K 96h UT0W72255PH601 UT0W72255SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 116 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT022JCS UT022JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT022JCSL UT022JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S22JCS UT0S22JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S22JCSL UT0S22JCL Metal cable clamp with strain relief (Fig.5) - 19.3 UT022AC Metal shrink boot adaptor (Fig.6) - - UT022AD Metal right angle cable clamp with strain relief nut (Fig.7) - 9/21 UT022LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 9/21 UT0S22JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 9/21 UT022JCPGN 3A/80V per IEC 61984 UTO Series | Connector 2255 (Shell size 22, 55x#20) Dimensions Square Flange - UTO0 34.75 maxi 14.5 Plug - UTO6 33 maxi 39.7 42 Male 39.5 Male Female 2.4 Female 27.5 maxi 31.7 29 maxi Jam Nut - UTO7 39 maxi Panel Cut Out 49.2 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.2 Front mounting O 34.1 Rear mounting O 37.7 Female 22.7 39 maxi 42.9 31.7 36.7 31.7 O 34.8 Male .9 37 Backshells (for Mated Connector Length: See Page 153) Long version - 88.4 Long version - 95.4 31.0 Fig. 1 Fig. 2 41.1 27 O 39.7 Short version - 84.1 O 35.7 Short version - 77.1 Fig. 6 Fig. 5 58.0 Short version - 99.6 Long version - 101.9 Long version - 110.9 55 91.7 48.0 Short version - 90.6 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 117 UTO Series | Connector 2255 (Shell size 22, 55x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT022DCG* UTG622DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD18B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT024DC 118 3A/80V per IEC 61984 UTO Series | Connector 2255 (Shell size 22, 55x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see page 132 Note: all dimensions are in mm Electrical Characteristics UTO 2255 Derating Curves Current (A) 10 UL 3A 250V UL94 V-0 CSA 2A 250V UL94 V-0 IEC 3A 80V 1.5kV 3 9 55 8 Test conditions Contact used: Machined contacts Wires used: 0.518mm 7 6 5 4 3 2 1 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Current use Limited use Not recommended use 119 UTO Series | Connector 2461 (Shell size 24, 61x#20) Layout OR OR OR OR WITH Connector Part Numbers Contact type Contacts supplied separately see page 123 Drilling pattern see page 183 Connector type Sealing Salt spray Square flange receptacle IP67 Part number* Male insert Female insert 96h UT0W02461PH UT0W02461SH IP68 & IP69K 96h UT0W02461PH6 UT0W02461SH6 IP67, IP68 & IP69K 48h UT0W62461PH UT0W62461SH IP67, IP68 & IP69K 96h UT0W62461PH02(Black) UT0W62461SH02(Black) IP67 48h UT0W72461PH UT0W72461SH IP68 & IP69K 48h UT0W72461PH6 UT0W72461SH6 IP67 96h UT0W72461PH01 UT0W72461SH01 IP68 & IP69K 96h UT0W72461PH601 UT0W72461SH601 Plug Jam nut receptacle * Other discrimination keying option, see page 182 Backshells 120 Part number Backshell type Shielding Cable range (O mm) min/max Short version Long version Short cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.1) - 11.5/18 UT024JCS UT024JC Short cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.2) - 15/24 UT024JCSL UT024JCL Short shielded cable gland with strain relief nut for water protected applications (IP68 & IP69K) (Fig.3) 3 13.5/18 UT0S24JCS UT0S24JC Short shielded cable gland with large strain relief nut for water protected applications (IP68 & IP69K) (Fig.4) 3 17/24 UT0S24JCSL UT0S24JCL Metal cable clamp with strain relief (Fig.5) - 20.6 UT024AC Metal shrink boot adaptor (Fig.6) - - UT024AD Metal right angle cable clamp with strain relief nut (Fig.7) - 17/30 UT024LPGN Shielded cable clamp with plastic strain relief nut (Fig.8) 3 17/29.5 UT0S24JCPGN Cable clamp with plastic strain relief nut (Fig.8) - 17/29.5 UT024JCPGN 3A/80V per IEC 61984 UTO Series | Connector 2461 (Shell size 24, 61x#20) Dimensions Square Flange - UTO0 34.75 maxi 15.3 Plug - UTO6 33 maxi 42.8 45.05 Male O 42.6 Male Female 2.4 Female 27.5 maxi 34.9 29 maxi Jam Nut - UTO7 41 maxi Panel Cut Out 53.4 Jam nut receptacle - UTO7 Jam nut receptacle - UTO0 O 3.9 Front mounting O 37.3 Rear mounting O 40.9 Female 23.6 41 maxi 46.0 34.9 39.9 34.9 O 38.0 Male .2 41 Backshells (for Mated Connector Length: See Page 153) Long version - 92.4 Long version - 99.4 31.0 Fig. 1 Fig. 2 42.4 27 O 42.9 Short version - 89.4 O 38.8 Short version - 82.4 Fig. 6 Fig. 5 67.0 Short version - 104.9 91.7 61 54.5 Short version - 95.9 Long version - 105.9 Fig. 3 Long version - 114.9 Fig. 4 Fig. 7 Fig. 8 Note: all dimensions are in mm 121 UTO Series | Connector 2461 (Shell size 24, 61x#20) Accessories and Tooling Dustcap (Receptacle) Dustcap (Plug) Handle (without Head) Tool Kit Part number Part number Part number Part number UT024DCG* UTG624DCG* SHANDLES TOOLKIT Gasket Crimp Tooling (without Shandles) Part number / Neoprene UTFD19B Contacts Part number of head Contact size RM/RC 24W3K(1) RM/RC 20W3K(1) RM/RC 18W3K(1) SM/SC 24WL3(1)(2) SM/SC 20WL3(1)(2) S20RCM* S20RCM* S20RCM* S20SCM20* S20SCM20* Standard contacts #20 O 1mm (1): Example of plating, for other plating options see page 129 (2): loose contact * Heads to be used with handle PN: SHANDLES + Handle = Head Complete set Extraction Tool #20 Part number RX20D44 * For dustcap without chain, skip "G", e.g. UT024DC 122 3A/80V per IEC 61984 UTO Series | Connector 2461 (Shell size 24, 61x#20) Contacts #20 Contact type Crimp Machined Stamped & formed reeled contacts PCB See note (2) for loose piece Machined (3) Part number Male Female Max wire O Max insulator O 26-24 RM24W3K RC24W3K 0.80 1.60 22-20 RM20W3K RC20W3K 1.15 1.60 20-18 RM18W3K RC18W3K 1.30 2.10 26-24 SM24W3TK6(1)(2) SC24W3TK6(1)(2) - 0.90-1.60 26-24 (1)(2) SM24W3S26 (1)(2) SC24W3S25 - 0.90-1.60 22-20 SM20W3TK6(1)(2) SC20W3TK6(1)(2) - 1.20-2.10 22-20 (1)(2) (1)(2) - 1.20-2.10 - - AWG - SM20W3S26 SC20W3S25 RMW5016K RCW5016K (1): Example of plating, for other plating options see page 129 (2): For loose piece contact packaging, place "L" in part number. Example: SM20WL3TK6 (3): For dimensions see v 132 Note: all dimensions are in mm Electrical Characteristics UTO 2461 Derating Curves Current (A) 10 UL 3A 250V UL94 V-0 CSA 2A 250V UL94 V-0 IEC 3A 80V 1.5kV 3 9 8 Test conditions Contact used: Machined contacts Wires used: 0.518mm 7 6 61 5 4 3 2 1 0 0 20 40 60 80 100 Ambient Operating Temperature (C) Current use Limited use 120 Not recommended use 123 UTO SERIES (c) 2013 SOURIAU - SOURIAU is a registered trademark UTO Series Contacts Description ............................................................................................................... 126 Contact Plating Selector Guide ................................................................................ 127 Contact Selector Guide ............................................................................................ 128 Packaging ................................................................................................................. 128 Crimp Contacts ........................................................................................................ 129 #16 Coaxial Contacts ............................................................................................... 131 PCB Contacts ........................................................................................................... 132 Fiber Optic Contacts ................................................................................................ 133 125 UTO Series | Contacts Contacts Description The UTO series is delivered without contacts and offers the unique feature to use the same style contact in any layout with the same active part size (i.e. #20, #16, #12, etc.). This provides our customers with an easy solution to buy only one type of contact to equip all their connectors even if housings/shell sizes are different. This provides the benefit of standardization and subsequent reduced inventory costs. In addition, it eliminates the need for added tooling and simplifies the assembly process. SOURIAU contacts are designed for simple snap-in installation and further eliminate the need for insertion tooling. In addition to the below "crimp" style contact options, the UTO series can also be equipped with PCB contacts. Crimp contacts are available in different versions: * machined 126 * stamped & formed * coaxial * fiber optic UTO Series | Contacts Contact Plating Selector Guide Once the contact size has been selected, the next step is to decide on which type to use. SOURIAU offers two main types of electrical contacts: * Machined * Stamped & Formed Machined contacts are generally chosen as a better solution for power applications or when lower quantities are needed. Stamped & formed contacts offer the ability to be crimped automatically which makes them more suitable for high volume production applications. The next decision to make is: What plating should I choose? The graph below can help guide you to plating recommendations based on application, mating cycles and current/voltage needs. Note: do not mix different plating (i.e. tin plated pin contacts with gold plated socket contacts). Number of cycles Vibration 250 100 0.4m of gold min Contacts Gold flash Silver Tin Current / Voltage 5mA 5mV Contact size #20 #12 #16 #8 127 UTO Series | Contacts Contact Selector Guide Contacts supplied separately Electrical characteristics: contact resistance #20 O1mm #16 O1.6mm Machined Available plating options < 6m Stamped & formed < 6m Machined < 3m Stamped & formed < 6m Machined < 5m Machined < 5m #12 O2.4mm #8 O3.6mm A 2 Ni + 2 Ag J Gold flash over 2 Ni K S31 S18 S25 S26 Min 0.4 gold over 2 Ni Active part: Gold flash over Ni Crimp area: Nickel Active part: 0.75 gold min over 2 Ni Crimp area: 1.3 tin over Ni Other: Nickel Active part: 0.75 Au over Ni Crimp area: flash Au over Ni TK6 2-5 Sn pre-plated D70 Superseded by S31 S6 Superseded by S18 Other platings on request (contact supplied separately) T T: 2m Ni mini all over + 3 to 5 m Sn all over D28 0.75 gold over Ni Packaging Due to the wide variety of applications, contact packaging is offered for small series (bulk package) and high volume production (reeled contacts): Size contacts #20 & #16 * 25 pieces loose package (stamped & formed contacts) * 50 pieces bulk package (machined contacts) * 1000 pieces bulk package (machined contacts) * 3000 pieces reeled (stamped & formed contacts) Size contacts #12 & #8 * 100 pieces bulk package (machined contacts) 128 * 5000 pieces reeled (machined contacts) UTO Series | Contacts Crimp contacts Standard Version Wire size Type Machined #20 O1 mm #16 O1.6 mm #8 O3.6 mm AWG mm Male 26-24 0.13-0.20 RM24W3K Female (1) Stamped & Formed 26-24 Machined 22-20 0.13-0.25 0.32-0.52 Max wire O RC24W3K Max insulator O Available plating see page 128 1.58 max K 0.89-1.58 TK6 S25 (female) S26 (male) 1.58 max K 1.17-2.08 TK6 S25 (female) S26 (male) 2.10 max K (1) SM24W3- SC24W3- SM24WL3-(2) SC24WL3-(2) RM20W3K RC20W3K (1) (1) SM20W3- SC20W3- SM20WL3-(2) SC20WL3-(2) 0.50-0.93 RM18W3K RC18W3K 30-28 0.05-0.08 RM28M1- RC28M1- 0.55 1.1 K, J 26-24 0.13-0.2 RM24M9- RC24M9- 0.8 1.6 K, J Stamped & Formed 26-24 0.13-0.25 SM24M1-(1) SM24ML1-(2) SC24M1-(1) SC24ML1-(2) 0.89-1.28 Insulation grip S31, S18, TK6 Machined 22-20 0.32-0.52 RM20M13- RC20M13- RM20M12- RC20M12- Stamped & Formed 22-20 0.35-0.5 SM20M1-(1) SM20ML1-(2) SC20M1-(1) SC20ML1-(2) 1.17-2.08 Machined 20-16 0.52-1.5 RM16M23- RC16M23SC16M1-(1) SC16ML1-(2) Stamped & Formed 22-20 Machined 20-18 Machined Machined 0.35-0.5 1.18 1.8 2.2 K, J Insulation grip S31, S18, TK6 1.8 3.2 K, J 3.0 No insulation grip S31, S18, TK6 Stamped & Formed 18-16 0.8-1.5 SM16M1-(1) SM16ML1-(2) Stamped & Formed 18-16 0.8-1.5 SM16M11-(1) SM16ML11-(2) SC16M11-(1) SC16ML11-(2) 2.0-3.0 Insulation grip S31, S18, TK6 Machined 16-14 1.5-2.5 RM14M30- RC14M30- 2.28 3.2 K, J 3.2 No insulation grip S31, S18, TK6 - 4.9 A, K - 6.5 A Stamped & Formed #12 O2.4 mm Part number Machined Machined (1) (1) 14 2.0-2.5 SM14M1SM14ML1-(2) SC14M1SC14ML1-(2) 22 0.13-0.4 82911457N- 82911456- 20 0.5 82911459N- 82911458- 18 0.75-1.0 82911461N- 82911460- 16 1.5 82911463N- 82911462- 14 2.5 82911465N- 82911464- 12 4 82911467N- 82911466- 16 1.5 82913601A 82913600A 14 2.5 82913603A 82913602A 12 4 82913605A 82913604A 10 6.0 82913607A 82913606A 8 10.0 82913609A 82913608A (1) contact reeled (2) loose contact Exemple: RM24W3K - Size #20, Machined, AWG24 wire. Contacts Contact size Note: all dimensions are in mm 129 UTO Series | Contacts Crimp contacts (continued) First Mate Last Break Contacts Contact size Type #16 O1.6 mm Machined Longer male contact (+1mm) #16 O1.6 mm Shorter female contact (-0.7mm) Machined Wire size Part number AWG mm Male 30-28 0.05-0.08 26-24 0.13-0.2 RM28M1GE1RM24M9GE1RM20M13GE1RM20M12GE1RM16M23GE1RM14M30GE1- - - RC28M1GE7RC24M9GE7RC20M13GE7RC20M12GE7RC16M23GE7RC14M30GE7- 22-20 0.32-0.52 20-16 0.52-1.5 16-14 1.5-2.5 30-28 0.05-0.08 26-24 0.13-0.2 22-20 0.32-0.52 20-16 0.52-1.5 16-14 1.5-2.5 Female Color band Max wire O (mm) Max insulator O (mm) ont Front Re Rear 0.55 1.1 - Red 0.8 1.6 Red Red 1.8 Black Red 2.2 Blue Red 3.2 - Red 2.28 - - Red 0.55 1.1 - Blue 0.8 1.6 Red Blue 1.8 Black Blue 2.2 Blue Blue 1.8 3.2 - Blue 2.28 - - Blue 1.18 1.8 1.18 Available plating see p. 128 K or J K or J How to make FMLB / LMFB onnection Contact 1 Contact 2 Standard male contact Standard female contact Longer male contact Standard male contact Standard female contact Shorter female contact Note: all dimensions are in mm 130 First Mate Last Break contacts should be chosen only if the cavity is not marked with the ground symbol. For cavities marked with the ground symbol, standard contacts will fulfill the same role as a first mate, last break contact used in a standard cavity. FMLB LMFB Ground symbol UTO Series | Contacts #16 coaxial contacts Coaxial Contact Range SOURIAU provides 2 types of coaxial contacts suitable for 50 or 75, coaxial cable or twisted pair cable. Monocrimp coaxial contact * The monocrimp one-piece coaxial contacts offer high reliability plus the economic advantage of a 95% reduction in installation time over conventional assembly methods. * This economy is achieved by simultaneously crimping both the inner conductor and outer braid or drain wire. Multipiece crimp coaxial contact * The inner conductor and outer braid is crimped individually. * The thermoplastic insulating bushing in the outer body is designed to accept and permanently retain the inner contact. * An outer ferrule is used to connect the braid to the outer contact and provide cable support to ensure against bending and vibration. Suitable for Coaxial cable or Twisted cable Contacts * For jacket diameter from 0.64 to 1.45mm Inner conductor from AWG30 to AWG24 * For jacket diameter from 1.78 to 3.05mm Inner conductor up to 2.44mm diameter Contacts for coaxial cable summary Contact range Contact type Male contact Female contact Multipiece RMDXK10D28 RCDXK1D28 Monocrimp RMDX60xxD28 RCDX60xxD28 Contact part number with cable combination See page 168 Cabling notice See pages 172 & 173 See page 174 Contacts for twisted pairs cable summary Contact range Male contact Female contact Contact part number with cable combination Multipiece RMDXK10D28 + YORK090 RCDXK1D28 + YORK090 See page 169 Monocrimp RMDX60xxD28 RCDX60xxD28 Contact type Cabling notice See page 170 See page 171 131 UTO Series | Contacts PCB contacts PCB Contacts PCB soldering The UTO series can be used in a wave soldering process, but not reflow soldering process. All high temperature processes are prohibited. Contact size Type #20 O1mm #16 O1.6mm Part number Male Female Short version RMW50A7K RCW50A7K Long version RMW5016K RCW5016K Short version RM20M12E8- RC20M12E8- Long version RM20M12E83- #8 O3.6mm - RC20M12E83- Plating see page 128 K K or J RC20M12E84- 82911685NPC 82911684NPC 2 m Ni 82911685NAPC 82911684NAPC 2 m Ni + 0.6 m Ag G Nominal length G (mm) Dimension of dipsolder contacts out of connector (contacts to be ordered separately). UTO0 and UTOW0 Connector size 10 12 14 16 18 20 22 24 RM20M 12E8K* 4.1 4.4 4.1 4.1 - Pin contact RM20M RMW 12E83K* 50A7K 9.2 9.51 9.2 9.51 9.2 9.51 9.2 9.51 9.2 5 4.85 5 4.85 5 3.35 3.6 RMW 5016K 10.41 10.41 10.41 10.41 6 6 6 4.6 RC20M 12E8K* 4.65 3.3 3.3 3.3 - RC20M 12E83K* 8.5 8.5 8.5 8.5 - Socket contact RC20M RCW 12E84K* 50A7K 4.65 2.4 4.65 2.4 5.35 2.4 4.65 2.4 4.65 - RCW 5016K 3.04 3.04 3.04 3.04 - UTO7 and UTOW7 Connector size 10 12 14 16 18 20 22 24 * Plating indication see page 128 Note: all dimensions are in mm 132 RM20M 12E8K* 4.1 4.4 4.1 4.1 - Pin contact RM20M RMW 12E83K* 50A7K 9.2 9.51 9.2 9.51 9.2 9.51 9.2 9.51 9.2 5 4.85 5 4.85 5 3.35 3.6 RMW 5016K 10.41 10.41 10.41 10.41 6 6 6 4.6 RC20M 12E8K* 4.65 3.3 3.3 3.3 - RC20M 12E83K* 8.5 8.5 8.5 8.5 - Socket contact RC20M RCW 12E84K* 50A7K 4.65 2.4 4.65 2.4 5.35 2.4 4.65 2.4 4.65 - RCW 5016K 3.04 3.04 3.04 3.04 - UTO Series | Contacts Fiber optic contacts Description Size 16 fiber optic contacts for UTO and other TRIM TRIO(R) connectors Size 16 fiber optic contacts are designed for the integration of optical links in UTO and other TRIM TRIO(R) cable connectors. The Fiber optic contacts are designed to accommodate: * Plastic Optical Fiber (POF) 1 mm core and 2.2 mm jacket Typical features and benefits are: * Socket contact is spring loaded to avoid any air gap between the two optical faces. * Low insertion loss is provided by high precision pieces. * Single jumpers, multiway harness and active device housings can be supplied regarding customer requirement. Technical Characteristics Performance Contacts * Fiber type: ........................................................................................................POF * Wave length:.................................................................................................. 650 nm * Optical insertion loss (typ.): ......................................................................... 2 dB max. * Jacketed external diameter: ...........................................................................2.2mm * Temperature range: .................................................................................-25C to +70C * Cable retention: ................................................................................................49N * Mating cycles without cleaning: ........................................................................ 50 * Max. mating cycles: .......................................................................................... 500 Construction * Contact body: Copper alloy Connector accommodation Any TRIM TRIO(R) size 16 contact can be used in any contact position in any connector in the TRIM TRIO(R) size 16 interconnection system: UTP, UTS, UTG, UTO. 133 UTO Series | Contacts Fiber optic contacts (continued) Ordering Information POF Contacts (Plastic Optical Fiber) Male contact ........................................ RMPOF1000 Female contact .................................. RCPOF1000B POF Contact (Plastic Optical Fiber) STANDARD TOOLING KIT - P/N 80MS0004 The standard tooling kit is made of the part numbers below that can be ordered separately as well. Part numbers 134 Descriptions SPECIFIC TOOLING LIST - Can only be ordered separately Part numbers Descriptions 80WD0005 Stripping tool 80WG0010 Needle 80WD0025 Automatic stripping tool for O 0.5 mm, 0.6 mm, 0.7 mm & 3.8 mm 80WG0015 Capsule 80WG0016 Syringe 80WM0006 Ruler Dry air spray 80WP0005 80WN0005 Polishing plate 80WN0006 Optical paper 80WP0013 Non slip base (to hold the polishing plate) 80WN0012 Dropper bottle 80WP0014 Polishing disk (grain size 9m) Wiping solvent 80WP0018 80WN0008 Polishing tool 80WP0019 Polishing disk (grain size 30m) 80WS0002 Crimping plier Contacts UTO Series | Contacts 135 UTO SERIES (c) 2013 SOURIAU - SOURIAU is a registratred trademark UTO Series Technical Information Tooling .................................................................................................................... 139 Crimping Instructions ............................................................................................. 140 Handle & Interchangeable Heads .......................................................................... 142 Extraction Tools ...................................................................................................... 143 Dimensions Overmoulded Harnesses .................................................................... 143 Assembly Instructions ............................................................................................. 144 Mated Connector Length ....................................................................................... 153 Rated Current & Working Voltage .......................................................................... 155 Shielding Effectiveness/Corrosion .......................................................................... 156 UL94 + UL1977 ....................................................................................................... 157 IEC 61984 & IP Codes Explained ........................................................................... 160 IEC 61140 Explained .............................................................................................. 162 What is NEMA Rating ? .......................................................................................... 163 Ethernet for the Layman ......................................................................................... 164 137 UTO Series | Technical Information Automatic Crimping Tools Mecal is a leader in manufacturing tooling for crimping terminals over a stripped wire. Established in 1976, Mecal has become one of the world's leading companies dedicated to the design and manufacture of semi automatic production tools for strip fed, open barrel crimp terminals, serving the Automotive, Telecom and Datacom industries. The extreme environment interconnect specialist "from deep sea to deep space". SOURIAU designs, manufactures and markets high performance interconnect solutions for severe environments dedicated to the aerospace, defense, light and heavy industry markets. SOURIAU has been working in partnership with Mecal for many years. With sales offices located in all major industrial regions of the world, the combined strengths of both organisations has resulted in a truly global solution to all your production tooling needs. Mini Applicator Stripper Mecal sales network: www.mecal.net/eng/retevendita.php 138 Presses UTO Series | Technical Information Tooling Crimp Tool Table Standard contacts Contact size #20 O 1mm #16 O 1.6mm Part number RM/RC 24W3K RM/RC 20W3K RM/RC 18W3K SM 24WL3S*(1) SC 24WL3S*(1) SM/SC 20WL3S*(1) RM/RC 28M1* RM/RC 24M9* RM/RC 20M13* RM/RC 20M12* RM/RC 16M23* RM/RC 14M30* SM/SC 24ML1* SM/SC 20ML1* SM/SC 16ML1* SM/SC 14ML1* SM/SC 16ML11* Head Handles Extraction tools S20RCM RX20D44 S20SCM20 SHANDLES S16RCM20 (endurance of SHANDLES tool = 5,000 cycles) S16RCM16 S16RCM14 RX2025GE1 S16SCM20 S16SCML1 S16SCML11 (1) loose contact Part number Hand tool 82911457N* / 82911456* 82911459N* / 82911458* #12 O 2.4mm 82911461N* / 82911460* 82911463N* / 82911462* M317 82911465N* / 82911464* 82911467N* / 82911466* 82913601A / 82913600A #8 O 3.6mm 82913603A / 82913602A 82913605A / 82913604A M317 82913607A / 82913606A 82913609A / 82913608A Tool with separate locator Positioner + locator setting 1-2 2 2 VGE10077A 3 3 4 3 3 4 VGE10078A 5 6/7 Extraction tools 51060210924 51060210936 Technical Information Contact size * see page 129 for plating options and other contact details Specific contacts (First mate Last break contacts) Contact size #16 O 1.6mm Longer RM contact Part number* RM28M1GE1K RM24M9GE1K RM20M13GE1K RM16M23GE1K RM20M12GE1K RM14M30GE1K Hand tools (SHANDLES) head Tool with separate locator Hand tool Positioner + locator setting S16RCM20 S16RCM16 S16RCM14 MH860 MH86186 RC28M1GE7K #16 O 1.6mm Shorter RC contact RC24M9GE7K RC20M13GE7K RC20M12GE7K RC16M23GE7K RC14M30GE7K Extraction tools S16RCM20 MH860 MH86164G M317 UH25 S16RCM16 S16RCM14 6/8 4/6 5/6 RX2025GE1 5/7 6/8 3 * see page 130 for plating options and other contact details Coaxial contacts See coax contacts details on page 131 and cabling notice pages 170 to 174. 139 UTO Series | Technical Information Crimping Instructions Wire Stripping Crimp Version Part number Male Machined contact Female Stripping length L (mm) #20 - O 1mm RM24W3- / RM20W3RM18W3- RC24W3- / RC20W3RC18W3- 4.8 #16 - O 1.6mm RM28M1- / RM24M9RM20M13- / RM20M12RM16M23- /RM14M30- RC28M1- / RC24M9RC20M13- / RC20M12- 4.8 RC16M23- /RC14M30- 7.1 #12 - O 2.4mm L 8291 1457- / 8291 14598291 1461- / 8291 14638291 1465- / 8291 1467- 8291 1456- / 8291 14588291 1460- / 8291 14628291 1464- / 8291 1466- 7 to 8 #8 - O 3.6mm 8291 3601- / 8291 36038291 3605- / 8291 36078291 3609Stamped & formed 6.5 to 7.5 #16 - O 1.6mm With insulation support SM24M1- / SM24ML1SM20M1- / SM20ML1- SC24M1- / SC24ML1SC20M1- / SC20ML1- 4 SM16M11- / SM16ML11- SC16M11- / SC16ML11- 4.65 L #20 - O 1mm SM24W3- / SM24WL3SM20W3- / SM20WL3Without insulation support SC24W3- / SC24WL3SC20W3- / SC20WL3- 4 #16 - O 1.6mm L Note: See page 129 for plating options and other contact details 140 8291 3600- / 8291 36028291 3604- / 8291 36068291 3608- SM16M1- / SM16ML1- SC16M1- / SC16ML1- 6.35 SM14M1- / SM14ML1- SC14M1- / SC14ML1- 6.35 UTO Series | Technical Information Crimping One of the key factors which affects the performance of a connector is the way contacts are terminated. Crimped connections are nowadays seen as the best solution to ensure quality throughout the lifetime of the product. Here are some reasons why we recommend this method of termination for UTO connectors: To ensure that the crimp tooling is performing according to original specifications, it is important to carry out regular checks. A common way to check the performance of tooling is with a simple pull test, ideally using a dedicated electric pull tester. Minimum recommended pull forces are indicated in the tables below: Active contact part Machined contacts size #20 O 1 mm S&F contacts size #20 O 1 mm Machined contacts size #16 O 1.6 mm Contact type Die location on heads RM24W3K RC24W3K 26/24 RM20W3K RC20W3K 22/20 RM18W3K RC18W3K 20/18 SM24WL3TK6* SC24WL3TK6* 26/24 SM20WL3TK6* SC20WL3TK6* 22/20 RM28M1K* RC28M1K* 30/28 RM24M9K* RC24M9K* 26/24 RM20M13K* RC20M13K* RM20M12K* RC20M12K* RM16M23K* RC16M23K* RM14M30K* RC14M30K* S&F contacts size #16 O 1.6 mm W 18 16 18 16 14 AWG 14 20 18 16 16 14 SM24ML1TK6* SC24ML1TK6* 26/24 SM20ML1TK6* SC20ML1TK6* 22/20 SM16ML11TK6* SC16ML11TK6* SM16ML1TK6* SC16ML1TK6* SM14ML1TK6* SC14ML1TK6* W Wire section range AWG 26 AWG 24 AWG 22 AWG 20 AWG 20 AWG 18 AWG 26 AWG 24 AWG 22 AWG 20 AWG 30 AWG 28 AWG 26 AWG 24 AWG 22 AWG 20 AWG 22 AWG 20 AWG 20 AWG 18 AWG 16 AWG 16 AWG 14 AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 18 AWG 16 22/20 Stamped & Formed contact Height (mm) H (0.075) Width (mm) W (0.075) 0.12 min 0.25 max 0.32 min 0.50 max 0.50 max 0.82 max 0.12 min 0.25 max 0.32 min 0.50 max 0.05 min 0.08 max 0.12 min 0.25 max 0.32 min 0.50 max 0.32 min 0.50 max 0.50 max 0.82 max 1.50 max 1.50 min 2.50 min 0.12 min 0.25 max 0.32 min 0.50 max 0.82 min 1.50 max 0.82 min 1.50 max Tensile straight test (mini) 15 N 32 N 40 N 60 N 60 N 90 N 15 N 32 N 40 N 60 N 11 N 11 N 15 N 32 N 40 N 60 N 40 N 60 N 60 N 90 N 150 N 150 N 230 N 15 N 32 N 40 N 60 N 90 N 150 N 90 N 150 N 0.95 1.27 1.26 1.78 1.35 1.86 0.80 1.49 1.01 1.53 1.14 1.41 1.15 1.41 2.50 max 230 N Section (mm) Tooling head p/n S20RCM S20SCM20 S16RCM20 1.26 1.76 1.66 1.80 1.96 2.10 2.30 2.18 2.28 2.43 2.68 2.78 0.84 1.50 1.02 1.54 1.32 1.36 1.49 1.7 2.09 2.10 2.02 2.05 1.79 2.58 Technical Information Machined contact H H Advantages (Extract from the IEC 60352-2): - Efficient processing of connections at each production level - Processing by fully-automatic or semi- automatic crimping machines, or with hand operated tools - No cold-soldered joints - No degradation of the spring characteristic of female contacts by the soldering temperature - No health risk from heavy metal and flux steam - Preservation of conductor flexibility behind the crimped connection - No burnt, discolored and overheated wire insulation - Good connections with reproducible electrical and mechanical performances - Easy production control. S16RCM16 S16RCM14 S16SCM20 S16SCML11 S16SCML1 *: example of plating options, for other plating see page 129 141 UTO Series | Technical Information Handle & Interchangeable Heads User Guide 1) Fully close then release the tool, keep it open. Open the 2 pins. 5) Place conductors, with no deteriorations, in the bucket contact. All strands to be located in the crimp bucket. 2) Choose the adapter head (sold separately), keep vertical and slide it into the handle until the mechanical end. 6) Position the contact in the bottom of the tool by checking its orientation. 3) Close the two pins simultaneously to maintain the head. 7) To crimp contact assembly-cable, tighten sharply the clip to the end of the mechanism. 4) Strip the cable properly checking the size recommended in the catalog on page 140. 142 8) To control crimp quality, slighty pull cable with two fingers to control retention. UTO Series | Technical Information Extraction Tools Contact size Extractor #20 RX20D44 #16 RX2025GE1 #12 51060210924 #8 51060210936 RX2025GE1 51060210936 RX20D44 51060210924 Contact Extraction Instructions Place the tool into the cavity from front face of the connector, push on the handle, then remove the contact. L L1 Shell size UTO0 Technical Information Dimensions Overmoulded Harnesses UTO7 L max L1 max L2 max L3 max L max L1 max L2 max L3 max 8 42.8 36.8 80.7 57.2 46.8 36.8 85.8 57.2 10 55.8 50.3 98.6 92 60.5 50.3 102.7 92 12 57.1 51.4 99.3 93.7 61.4 51.4 106.4 93.7 14 62.5 56.3 100.3 94.6 67.6 56.3 104.8 94.6 L2 L3 Note: all dimensions are in mm 143 UTO Series | Technical Information Assembly Instructions UTO0 Assembly (Mounting Suggestion) * * * * Strip wires and crimp contacts (see pages 140 & 141) Insert contacts into connector cavities (insert manually or use tool RTM205 crimp contacts) Place receptacle in the panel cut-out Secure receptacle with screws (not supplied) Tighten screws: M2.5 for size connectors 10 to 22, M3 for size connectors 24 (recommended torque: see table below) * For complete sealing of the system use optional gasket and sealed screw solution (not sold by SOURIAU). Front mounting : Crimp version Rear mounting : Crimp version Gasket (optional) Gasket (optional) 3mm max Receptacle flange 3mm max Receptacle flange Panel thickness: 2.5mm max 2. Panel Pa Shell size Screws tightening torque (Nm) 144 10 12 14 16 18 20 22 24 0.30/0.40 0.30/0.40 0.30/0.40 0.30/0.40 0.35/0.45 0.50/0.60 0.55/0.65 0.55/0.65 UTO Series | Technical Information UTO7 Assembly (Mounting Suggestion) Shell size Jam nut torque (Nm) Exterior jam nut dim. (mm) O Wire max (mm) Panel thickness max (mm) 10 6 22.2 3.2 3.2 12 9 27.0 3.2 3.2 14 10 32.0 3.2 3.2 16 13 33.3 3.2 3.2 18 20 36.5 3.2 3.2 20 23 39.7 3.2 6.4 22 25 42.9 3.2 6.4 24 26 46.0 3.2 6.4 Panel thickness Jam nut O-ring Technical Information * Strip wires and crimp contacts (see pages 140 & 141) * Insert contacts into connector cavities (insert manually or use tool RTM205 crimp contacts ) * Seat o-ring, place receptacle in the panel cut-out * Tighten jam nut 145 UTO Series | Technical Information Assembly Instructions (Continued) * UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Unshielded Cable UTO0 Adapter Cable gland body Backshell nut H Ferrule UTO6 UTO7 * * * * Slide accessories onto the cable Strip external cable jacket (see dimension H in the table below) Strip wires and crimp contacts (see pages 140 & 141) Insert contacts into connector cavities (insert manually or use tool RTM205) * Screw adapter to the rear of the connector body and screw cable gland body to adapter and tighten (recommended torque: see table below) * Mate the plug with the receptacle to make the following step easier * Slide ferrule inside the cable gland body as shown in fig. A * Tighten backshell nut with cable gland body as shown in fig. B (recommended torque: see below). fig. A Shell size fig. B Adapter tightening torque (Nm) Cable gland body tightening torque (Nm) Backshell nut tightening torque* (Nm) 6 10 10 14 14 24 24 24 6 10 10 14 14 24 24 24 5 8 8 12 12 20 20 20 10 12 14 16 18 20 22 24 H min. (mm) JCS/JCSL Male 21 21 25 32 37 39 41 47 JC/JCL Female 29 29 33 40 45 47 50 55 Male 32 31 39 43 47 49 53 57 Female 39 39 47 51 55 57 61 65 * Indicative torque, needs to be adjusted depending on the cable used Spanner size Shell size 10 12 & 14 16 & 18 20, 22 & 24 146 JCS/JC Cable gland body 17 mm 22 mm 26 mm 33 mm JSCL/JCL Backshell nut 14 mm 20 mm 24 mm 30 mm Cable gland body 17 mm 22 mm 30 mm 40 mm Backshell nut 17 mm 22 mm 30 mm 40 mm UTO Series | Technical Information * UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Shielded Cable Adapter Cable gland body Backshell nut UTO0 L H Shielding ferrule UTO6 UTO7 * * * * Slide accessories onto the cable Strip external cable jacket (see dimension H and L in the table below) Strip wires and crimp contacts (see pages 140 & 141) Insert contacts into connector cavities (insert manually or use tool RTM205) * Screw adapter to the rear of the connector body and screw cable gland body to adapter and tighten (recommended torque: see table below) * Mate the plug with the receptacle to make the following step easier * Slide ferrule inside the cable gland body as shown in fig. A * Tighten backshell nut with cable gland body as shown in fig. B (recommended torque: see below). fig. A fig. B Adapter tightening torque (Nm) Cable gland body tightening torque (Nm) Backshell nut tightening torque (Nm) 10 12 14 16 18 20 22 24 6 10 10 14 14 24 24 24 6 10 10 14 14 24 24 24 5 8 8 12 12 20 20 20 H min. (mm) JCS/JCSL JC/JCL Male Female Male Female 50 58 61 68 54 61 65 73 59 66 73 80 68 75 79 86 72 80 83 91 80 89 90 98 83 91 94 102 88 96 98 106 L min. (inch) Technical Information Shell size 8 12 12 12 12 14 14 14 * Indicative torque, needs to be adjusted depending on the cable used Spanner size Shell size 10 12 & 14 16 & 18 20, 22 & 24 JCS/JC Cable gland body 17 mm 22 mm 26 mm 33 mm JSCL/JCL Backshell nut 14 mm 20 mm 24 mm 30 mm Cable gland body 17 mm 22 mm 30 mm 40 mm Backshell nut 17 mm 22 mm 30 mm 40 mm 147 UTO Series | Technical Information Assembly Instructions (Continued) UTO0 or UTO7 with UTO6 + AC Backshell Assembly UTO0 Modular gasket Cable clamp UTO6 UTO7 * * * * 148 Slide accessories onto the cable Strip external cable jacket Strip wires and crimp contacts (see pages 140 & 141) Insert contacts into connector cavities (insert manually or use tool RTM205) * Tighten backshell with plug and mate plug with a receptacle (recommended torque values to be applied according to the table below) * Tighten backshell screws. Shell size Cable clamp tightening torque (Nm) 10 Clamp (mm) Min Max 4 1.5 5.0 12 5 3.0 8.2 14 5 4.0 10.0 16 9 6.0 13.0 18 9 8.5 16.0 20 11 10.0 16.0 22 13 9.0 19.3 24 15 11.0 20.6 UTO Series | Technical Information UTO0 or UTO7 with UTO6 + LPGN Backshell Assembly UTO0 Right angle cable clamp UTO6 UTO7 * Tighten backshell with plug and mate plug with a receptacle (recommended torque values to be applied according to the table below) * Tighten backshell screws. O Cable range (mm) B C Shell size Right angle cable clamp tightening torque (Nm) 10 6 5 7.5 10 - 12 10 7.5 10 13 - 14 10 7.5 10 13 - A D 16 14 7.5 11 13.5 16 18 14 10 13.5 17 20 20 24 10 13.5 17 20 22 24 10 13.5 17 20 24 24 18 22 25.5 29 Technical Information * Remove inner part of the modular gasket to adjust the internal diameter to fit the cable (see table) * Slide accessories onto the cable * Strip external cable jacket * Strip wires and crimp contacts (see pages 140 & 141) O Cable range A B C D 149 UTO Series | Technical Information Assembly Instructions (Continued) * UTO0 or UTO7 with UTO6 + JCPGN Backshell Assembly Outer shielding ferrule UTO0 Washers sher PG- nut L H UTO6 Inner shielding ferrule PG-tube adapter Modular gasket UTO7 * Place cable braid shield over inner shielding ferrule (See fig. A) and slide the outer ferrule over the braid shield for UTOS-JCPGN * Screw PG-tube adapter with plug (recommended torque: see below table) * Tighten PG-nut with PG-tube adapter (See fig. B) * Tighten PG-nut screws. * Mate UTO6 (plug) with UTO0 or UTO7 already mounted on a panel * Slide accessories onto the cable * Strip external cable jacket (see dimension H and L) * Strip wires and crimp contacts (see pages 140 & 141) * Insert contacts into connector cavities (insert manually or use RTM205 tool) UTOS-JCPGN fig. A O Cable range (mm) H min. (mm) PG-tube tightening torque (Nm) UTO UTOS Pin contacts Socket contacts 10 4 4 to 10 4 to 8.8 26.5 34.2 17.6 12 6 4 to 11.9 4 to 11.9 26.5 34.2 17.6 14 10 6.5 to 13.5 6.5 to 13.5 29.6 37.2 20.6 16 10 6.5 to 16 6.5 to 16 31.6 39.2 22.6 Shell size L min. (mm) 18 10 6.5 to 16 6.5 to 16 36.9 42.3 26.7 20 15 9 to 21 9 to 21 36.4 41.8 26.1 22 15 9 to 21 9 to 21 43.4 48.8 33.2 24 15 17 to 29.5 17 to 29.5 43.8 49.2 33.6 O individual braid shield conductor betweenn 0.3 and 0.5mm Torques to be applied with the plug mated with the receptacle. 150 fig. B UTO Series | Technical Information UTO6 or UTO7 with GN Backshell Assembly UTO6 Nut Grommet + compression ring UTO7 * Insert the other contacts * Tighten the nut to rear of either UTO7 or UTO6 (recommended torque values to be applied according to the table below). Shell size layout Nut tightening torque (Nm) 10 4 1 12 8 1.5 14 7 1.5 14 12 1.5 O Wire From 1.7 mm to 3.0 mm Technical Information * Strip wires and crimp contacts (see pages 140 & 141) * Insert first contact into the grommet (first contact in cavity A, no tool is required). Then insert the contact in the connector cavity A (insert manually or use tool RTM205) 151 UTO Series | Technical Information Assembly Instructions (Continued) UTO6 or UTO7 with GJC Backshell Assembly Nut UTO6 Adapter + mounted gasket Cable range Grommet + compression ring Reducing UTO7 * Strip wires and crimp contacts (see pages 140 & 141) * Insert first contact into the grommet (first contact in cavity A, no tool is required). Then insert the contact in the connector cavity A (insert manually or use tool RTM205) * Insert the other contacts Shell size 152 Layout Recommended jacket strip length (mm) Male Female Adapter tightening torque (Nm) Standard Cable ranges * Tighten adapter with plug, choose right seal (waste the other seal) * Tighten the nut to rear of either UTO7 or UTO6 (recommended torque values to be applied according to the table below). Nut tightening torque (Nm) O Cable range Standard seal (mm) O Cable range Reducing seal (mm) 10 4 21 29 1.5 1 2.5/8.0 1.5/5.0 12 8 25 33 2 2.5 5.0/12.0 3.0/9.0 14 7 29 36 3 2.5 7.0/14.0 5.0/12.0 14 12 29 36 3 2.5 7.0/14.0 5.0/12.0 O Wire From 1.7 mm to 3.0 mm UTO Series | Technical Information Mated Connector Length with Backshell UTO0 + UTO6 + AC UTO0 + UTO6GN A C B D UTO7 + UTO6 + AC UTO7 + UTO6GN UTO0 + UTO6 + AC backshell + GN backshell + AC backshell + GN backshell A max (mm) C max (mm) B max (mm) D max (mm) 10 53.5 39.1 58.3 43.9 12 53.5 38.9 58.3 43.7 14 52.0 39.4 56.8 44.2 16 55.5 - 60.3 - 18 56.5 - 61.3 - 20 58.5 - 64.0 - 22 57.0 - 62.5 - 24 59.0 - 64.5 - Backshell without shielding Backshell with shielding UTO0 + UTO6 + UTO with JCS or JC or JCSL or JCL UTO0 + UTO6 + UTOS with JCS or JC or JCSL or JCL E H F L UTO7 + UTO6 + UTOS with JCS or JC or JCSL or JCL UTO7 + UTO6 + UTO with JCS or JC or JCSL or JCL UTO0 + UTO6 + UTO with Shell size UTO7+ UTO6 + UTO with UTO0 + UTO6 + UTOS with UTO7+ UTO6 + UTOS with JCS JC JCSL JCL JCS JC JCSL JCL JCS JC JCSL JCL JCS JC JCSL JCL E max E max E max E max F max F max F max F max H max H max H max H max L max L max L max L max 10 68.1 80.1 68.1 80.1 72.8 84.8 72.8 84.8 78.1 90.1 79.1 91.1 82.8 94.8 83.8 95.8 12 68.1 81.1 69.1 82.1 72.8 85.8 73.8 86.8 81.1 94.1 81.1 94.1 85.8 98.8 85.8 98.8 14 73.1 87.1 74.1 88.1 77.8 91.8 78.8 92.8 86.1 100.1 86.1 100.1 90.8 104.8 90.8 104.5 16 82.1 93.1 88.1 99.1 86.8 97.8 92.8 103.8 92.1 103.1 102.1 113.1 96.8 107.8 106.8 117.8 18 85.1 95.6 91.1 101.6 89.8 100.3 95.8 106.3 95.1 105.6 105.1 115.6 99.8 110.3 109.8 120.3 20 98.4 108.2 105.4 115.2 103.9 113.7 110.9 120.7 111.9 121.7 120.9 130.7 117.4 127.2 126.4 136.2 22 100.7 112.0 107.7 119.0 106.2 117.5 113.2 124.5 114.2 125.5 123.2 134.5 119.7 131.0 128.7 140.0 24 106.9 116.9 113.9 123.9 112.4 122.4 119.4 129.4 120.4 130.4 129.4 139.4 125.9 135.9 134.9 144.9 Note: all dimensions are in mm 153 Technical Information Shell size UTO7+ UTO6 UTO Series | Technical Information Mated Connector Length with Backshell (Continued) UTO0 + UTO6 + JCPGN M N UTO7 + UTO6 + JCPGN UTO0 + UTO6 + JCPGN UTO7+ UTO6 + JCPGN M max (mm) N max (mm) 10 82.4 87.1 12 84.6 89.3 14 89.6 94.3 16 95.0 99.7 Shell size 18 99.1 103.8 20 111.1 116.6 22 118.2 123.7 24 132.9 138.5 Note: all dimensions are in mm 154 UTO Series | Technical Information Rated Current & Working Voltage Current Carrying Capacity The current carrying capacity of a connector is limited by the thermal properties of materials used in its construction. The amount of current that can be handled depends on the size of cable used, the ambient temperature and the heat that is generated inside the connector. Part 3 of the IEC 60512 standard determines through a derating curve, the maximum current permissible, which varies from one layout to another (Fig.1 & Fig.2). Wire size plays an important role in dissipating heat and avoid overheating (Fig.1 & Fig.3). Please note that the curve should be adjusted when dealing with potential hot spots, which can occur as a result of unequal loading of current across a number of contacts. As a general rule, it is best to avoid placing power handling contacts in the middle of the connector; try to locate them towards the edge where heat can be dissipated more effectively. Eventually you should find a level which represents the permissible operating range: Fig.1: UTO 12-4 - 1.5mm wires 28 28 25 25 23 23 20 18 15 13 10 20 18 15 13 10 8 8 5 5 3 3 0 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) 0 20 40 60 80 100 120 Ambient Operating Temperature (C) Fig.3: UTO 12-4 - 2.5mm wires 35 33 30 28 25 23 Current use 20 18 Technical Information Current (A) Fig.2: UTO 12-8 - 1.5mm wires 30 Current (A) Current (A) 30 Limited use 15 13 Not recommended use 10 8 5 3 0 0 20 40 60 80 100 120 Ambient Operating Temperature (C) The rated current is defined as uninterrupted continuous current that a connector can take when all contacts are energized simultaneously without exceeding the maximum limit of temperature. The earth contact is never loaded. 155 UTO Series | Technical Information Shielding Effectiveness/Corrosion Shielding Effectiveness EMC (Electro-Magnetic Compatibility) means a device (e.g. a connector) can tolerate interferences and continue to work properly. It's generally measured via the shielding effectiveness. This value is a ratio between the power radiated inside to the maximum power interferences outside. (dB)=10Log Pin Pout Pin: Power in Pout: Power out 156 0 48 Hrs 96 Hrs Outdoor application with corrosive atmospheres (Salt Spray and 4 Corrosive Gases) Over the years, many different test methods have been developed but never really captured the exact equivalence between testing scenarios and real electronic device exposure to corrosive environments. SOURIAU has been developing, manufacturing and testing connector solutions for more than 90 years and has developed a unique corrosion test based on Salt Spray exposure combined with four additional corrosive gases. Typical industrial applications may involve exposure to corrosive atmospheres equivalent to 48 or 96 hours. SOURIAU's UTO product series has been validated to withstand corrosive agent exposure at these timeframes. In addition, we can offer different solutions and plating options to withstand longer corrosion exposure times and test up to 500 hours. Indoor application Tempory outdoor exposure Control of corrosion impact on electronic devices is an important expertise. Metal connectors suitable for outdoor and indoor use should be able to withstand climate ingress, exposure to salt spray and corrosive gases while still maintaining mechanical and electrical functionality. Outdoor application Corrosion Resistance 500 Hrs UTO Series | Technical Information UL94 + UL1977 Underwriter Laboratories There are two main standards for industrial connectors: UL94 & UL1977 UL94 This standard is dedicated to plastics flammability. It characterises how the material burns in various orientation and thicknesses. The UTO series has been rated at V-0 & HB. Procedure: A specimen is supported in a vertical or horizontal position and a flame is applied to the bottom of the specimen. The flame is applied for ten seconds and then removed until flaming stops, at which time the flame is reapplied for another ten seconds and then removed. Two sets of five specimens are tested. V-0 Vertical burning: * Specimens must not burn with flaming combustion for more than 10 seconds after each test flame application * Total flaming combustion time must not exceed 50 seconds for each set of 5 specimens * Specimens must not burn with flaming or glowing combustion up to the specimen holding clamp * Specimens must not drip flaming particles that ignite the cotton * No specimen can have glowing combustion remain for longer than 30 seconds after removal of the test flame. Material 130.5mm 1251mm 45 3001mm ~ ~ Technical Information Cotton 1001mm HB Horizontal burning: * A material classified HB shall not have a burning rate exceeding 40 mm per minute over a 75 mm span for specimens having a thickness of 3.0 to 13 mm * A material classified HB shall not have a burning rate exceeding 75 mm per minute over a 75 mm span for specimens having a thickness less than 3.0 mm * A material classified HB shall cease to burn before the 100 mm reference mark. 251mm Material 130.5mm 45 Wire gauze 45 101mm Wire gauze 157 UTO Series | Technical Information UL94 + UL1977 (Continued) Underwriter Laboratories UL1977 There are several standards which deal with plug and receptacle. Each of them is only for a small area of applications. It could be telecommunication, etc. The UL 1977 covers single and multipole connectors intended for factory assembly. Requirements apply to devices taking into account intensity and voltage. The categories are as follows: 30 V (42 V peak) 0 600 V 0 Type 0 Type 1A Type 2 31 A Tybe 1B Type 3 Type 4 1000 A According to above table, the level of performance that has to be reached could be different. Most of them are explained in the following page. Insulating materials: Material uses for electrical insulation, as a minimum, have to comply with the characteristics shown below: * Minimum ratings for polymeric materials Type Flame rating Relative thermal index (RTI) Electrical/mechanical w/o impact */** 0 - 50/50 1A HB 50/50 1B HB 50/50 2 HB 50/50 3 HB 50/50 4 HB 50/50 * The RTI of the material shall not be lower than the temperature measured during the Temperature Test. ** For a thickness less than that for which a value has been established, the RTI of the minimum thickness with an established value shall be used. Assembly: Connector has to be keyed to prevent any mismating that can damage the machine or hurt the user. In the same way, plugs and sockets have to be equipped to protect persons against contact with live parts. Finally the identified grounding contact shall be located so that the corresponding electrical continuity has to be completed before any other contact. 158 UTO Series | Technical Information Underwriter Laboratories UL1977 Spacing: For a 250V max connector, distance through air or over material shall be 1.2mm whereas from 250V to 600V connector the spacing is 3.2mm minimum. These distances have to be taken between uninsulated live parts as shown in the matrix below: * Applicability of spacing requirements Type Uninsulated live part - uninsulated live part of opposite polarity Uninsulated live part - uninsulated grounded metal part Uninsulated live part - exposed dead metal part 0 No No No 1A Yes Yes Yes 1B Yes Yes No 2 Yes Yes Yes 3 Yes Yes Yes 4 Yes Yes Yes An alternative way to determine voltage rating is with the Dielectric-Withstand test. If during one minute there is no arc-over or breakdown the rated voltage is given as shown below: a) 500 volts for a type 1B device b) 1000 volts plus twice rated voltage for types 1A, 2, 3 and 4 devices. Marking: A device shall be legibly marked with the manufacturer's trade name, trade mark, or other descriptive marking by which the organisation responsible for the product may be identified. (Exception: If the device is too small, or where the legibility would be difficult to attain, the manufacturer's name, trademark, or other descriptive marking may appear on the smallest unit container or carton) The following shall be marked on the device or on the smallest unit container or carton or on a stuffer sheet in the smallest unit container or carton: Example - Marking for the arrangement 10-3: Technical Information a) The catalog number or an equivalent designation b) The electrical rating in both volts and amperes, if assigned c) Whether ac or dc, if restricted d) Flammability class, if identified 10A 500V UL94 V-0 159 UTO Series | Technical Information IEC 61984 & IP Codes Explained IEC 61984 The norm is dedicated to connectors with rated voltage above 50V and up to 1000V and rated currents up to 125A per contact. Depending on your application connectors should be compliant with another standard. This has to be double checked with the customer. There are a lot of constructional requirements and performances specified in that standard. Most of them are illustrated in greater details hereafter. Provisions for earthing: The UTO connector is intended to be used on Class I or Class III (see IEC 61140) systems. Even if the purpose of our connector is not to interrupt current, there is a need to add a protective earth contact. This one shall be a "First mate, last break" style. Critically, among all of the normal assumptions we make in designing a connector, this contact has to be considered as a live part and must be protected attached to the ground wire. First digit (foreign bodies protection) IP Code: IP is a coding system defined by the IEC 60529 to indicate the degrees of protection provided by an enclosure. The aim of this is to give information regarding the accessibility of live parts against ingress of water and other foreign bodies. 1st digit Degree of protection 0 No protection against accidental contact. No protection against solid foreign bodies. 1 Protection against contact with any large area by hand and against large solid foreign bodies with a diameter bigger than 50 mm. 2 Protection against contact with the fingers. Protection against solid foreign bodies with a diameter bigger than 12 mm. 3 Protection against tools, wires or similar objects with a diameter bigger than 2.5 mm. Protection against small solid bodies with a diameter bigger than 2.5 mm. 4 Same as 3 however diameter is bigger than 1 mm. 5 6 Full protection against contact. Protection against interior injurious dust deposits. Total protection against contact. Protection against penetration of dust. UTO offers high sealing performance IP68 / 69K... Even in dynamic situations. Code letters (international Protection) IP 6 8 Second digit (water protection) 2nd digit Degree of protection 0 No protection against water. 1 2 Drip-proof. Protection against vertical water drips. Drip-proof. Protection against water drips up to a 15 angle. 3 Spray-proof. Protection against diagonal water drips up to a 60 angle. 4 Splash-proof. Protection against splashed water from all directions. Hose-proof. Protection against water (out of a nozzle) from all directions. Protection against temporary flooding. 5 6 7 8 Protection against temporary immersions. Protection against water pressure. Pressure to be specified by supplier. In addition to the IEC 60529 we conjointly use the DIN 40050 part 9 which are dedicated to road vehicles. The main differences are: * First digit: 5 replaced by 5K, 6 by 6K. In the DIN the tested equipment is not depressurized as it is in the IEC. * Second digit: 5K and 6K has been added and are equivalent respectively to 5 and 6 but with higher pressure. 9K which represents the High pressure cleaning. 9K IEC 61984 ed.2.0 "Copyright (c) 2008 IEC Geneva, Switzerland.www.iec.ch" IEC 60664-1 ed.2.0 "Copyright (c) 2007 IEC Geneva, Switzerland.www.iec.ch" 160 High pressure hose-proof. Protection against high pressure water (out of a nozzle) from all directions. UTO Series | Technical Information IEC 61984 Overvoltage UTO connectors are qualified to be used on systems rated at Overvoltage category III Per the IEC 60664-1 (formely VDE 0110) each category is linked to the end application and where the device will be implemented: * Category IV (primary overcurrent protection equipment): Origin of the installation * Category III (any fixed installation with a permanent connection) Fixed installation and equipment and for cases where the reliability and the availability is subject to special requirements * Category II (domestic appliances): Energy consuming equipment to be supplied from the fixed installation * Category I (protected electronic circuit): For connection to circuit in which measures are taken to limit transient overvoltage. Pollution degree Per the IEC 60664-1 (formerly VDE 0110) the environment affects the performance of the insulation. Particles can build a bridge between two metal parts. As a rule dust mixed with water can be conductive and more generally speaking metal dust is conductive. Finally, the standard defines 4 levels of pollution: * Degree 1 (Air conditioned dry room): No pollution or only dry, non conductive pollution occurs. The pollution has no influence. * Degree 2 (Personal computer in a residential area): Only non conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be expected. * Degree 3 (Machine tools): Conductive pollution occurs or dry non-conductive pollution occurs which becomes conductive due to condensation which is to be expected. Technical Information * Degree 4 (Equipments on roof, locomotives): Continuous conductivity occurs due to conductive dust, rain or other wet conditions. Finally, the harsher the environment is, the longer clearance and creepage distances should be. Nonetheless, according the IEC 61984, enclosure rated at IP54 or higher can be dimensioned for a lower pollution degree. This applies to mated connectors disengaged for test and maintenance. Marking The marking should give enough details to the user to know what the main characteristics are and without going deep in technical documentation. Below examples identify the suitability of the connector: * Example 1: Marking of a connector with rated current 16A, rated voltage 400V, rated impulse voltage 6kV and pollution degree 3, 2 and 1 for use in any system, preferably unearthed or delta-earthed systems: 16A 400V 6kV 16A 400V 6kV 33 * Example 2: Marking of a connector with rated current 16A, rated insulation voltages line-to-earth 250V, line-to-line 400V, rated impulse voltage 4kV and pollution degree 3, 2 and 1 for use in earthed systems: 16A250V 250V400V 400V4kV 4kV3 3 16A 161 UTO Series | Technical Information IEC 61140 Explained IEC 61140 On a daily basis, we are using many electrical appliances, some are grounded, and some are not. The levels of grounding protection are clearly defined by the International Electrotechnical Commission standard IEC 61140, a standard that has an influence on our connectors and how they should be used; our customers therefore need to pay particular attention to the three categories defined within this standard to ensure compatibility with their system. Everything explained hereafter is valid for connectors not intended to interrupt current. Class I: Devices which belong to this category have their chassis grounded via the ground wire (green/yellow in Europe, green in the US, Canada and Japan). A fault in the appliance might cause a live conductor to energize the casing. In this case, the current flows to the ground conductor and the circuit interrupter will cut off the power supply. In case of the UTO series, it means the envelope (coupling ring, backshell and housing) may become live, therefore, care needs to be taken to attach the connector to the ground. This is usually done via the ground conductor using a splice between the ground contact and the housing. Class II: Products in this category have reinforced insulation, meaning that the casing does not need to be connected to ground. In this case, the possibility of electric shock has been removed. Most of the time, reinforced insulation means double insulation, i.e. the second layer will take over the first one in case the first one fails. The UTO series is not designed to comply with this standard, so we cannot recommend it for this product category. Note: UL 1310 also defines a class II device, but in that case this is just to set the upper limit of use, like a wall charger for our cell phone. Class III: In this category, electrical appliances are fed by a low voltage source (<48VAC or < 120VDC). In normal conditions live conductors can be accessible without any risk for the end user. No particular attention needs to be taken in regards to UTO series when it comes to a class III device. Conclusion : UTO series can be used in class I and class III environments, but each category affects the product performance. Throughout the catalog, current and voltage ratings have been given for class I devices keeping in mind the ground conductor needs to be attached according to recommended wiring instructions. Note: Special applications like recreational vehicles are not under the scope of the IEC 61140. 162 UTO Series | Technical Information What is NEMA Rating ? * NEMA ratings vs IP ratings Whereas IP ratings only consider protection against ingress of foreign bodies (first digit) and ingress of water (second digit), NEMA ratings consider these but also verify protection from external ice, corrosive materials, oil immersion, etc. The correlation between NEMA & IP being limited only to dust and water, we can state that a NEMA type is equivalent to an IP rating but it is not possible to say the contrary. Below a list of some NEMA standards: Enclosure rating IP20 Type 1 * IP22 IP55 Type 3 Type 3R IP64 IP65 IP66 IP67 * * Type 3S * Type 4 * Type 4X * Type 6 * Type 12 * Type 13 * * indicates compliance 6 IP67 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during occasional temporary submersion at a limited depth and damage from external ice formation. 6P IP67 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment, falling dirt, hose-directed water, the entry of water during prolonged submersion at a limited depth and damage from external ice formation. Technical Information Type 6 rating can be either Type 6 or Type 6P - please see below: 163 UTO Series | Technical Information Ethernet for the layman In order to explain basic Ethernet theory, we can use a functional comparison to a busy city with highways, buildings and cars. To illustrate this, the table below provides correlation between the different components/pieces/links that encompass Ethernet network connectivity, and the larger scale infrastructure of a metropolitan city. * City: * Buildings: * Roads: * Cars: * Tolls: * Bridges: * Traffic laws: The network itself End equipment, PC, server, etc. Ethernet cabling Data packets, datagrams, bits, bytes, etc. Firewalls Connectors Protocol/communication specifications Ethernet Basics Ethernet is a widely used communications protocol that is used to transmit data packets (datagrams) between network devices. Imagine a highway in a large metropolitan area six lanes wide at rush hour. The vehicles on the highway need rules to follow so that they get to their destination without crashing into each other. In an Ethernet network link, there could be 100 million bits of information transmitted in one second. In the Ethernet standard, there exist rules to govern packet structure, transmission requirements, error correction, communication with end equipment, etc. Examining the differences between 100Mhz, 100 Base TX, Cat5e/Cat6. What does it all mean? When discussing connectors and Ethernet, there are a few key details to be aware of: * 100Mhz is a measurement of Frequency for the signal - Comparable to the Speed Limit of a highway * 100BaseTX (or Fast Ethernet) is an Ethernet link standard and identifies available link bandwidth. The bandwidth is measured in units of MBits/S (megabits per second) - Comparable to the number of cars that pass a point in one second * Cat5e/Cat6 are an EIA/TIA standard for performance and physical characteristics for cables and connectors - Comparable to performance specifications of the car and highway. In connectors and cables, Fast Ethernet uses 2 pairs. One for transmit and one for receive. This way data traffic can flow in both directions simultaneously. 164 UTO Series | Technical Information Souriau offering: Standard solutions. UTO size 10, 6 contacts - Cat5e Twisted pairs UTO size 12, 10 contacts - Cat5e Twisted pairs 1 (Pair 1) C 2 (Pair 1) B 3 (Pair 2) G 4 (Pair 2) H 1 (Pair 1) A 2 (Pair 1) B 3 (Pair 2) E 4 (Pair 2) D 106 6 O 1 (#20) Shielding continuity done in cavity C&F. Note: Shielding can be replaced by DC power. 1210 10 O 1 (#20) Cat6 if shielding continuity done by other contact UTO size 16, 19 contacts -Cat5e Twisted pairs (1Gb/s) 1 (Pair 1) A 2 (Pair 1) B 3 (Pair 2) D 4 (Pair 2) E 5 (Pair 3) G 6 (Pair 3) H 7 (Pair 4) K 8 (Pair 4) L 1619 19 O 1.6 (#16) UTO size 10, 4 contacts - Cat6 Quad cable 1 (Pair 1) A 2 (Pair 1) B 104 4 O 1.6 (#16) What about using coax contacts ? Ethernet twisted pairs carry a symmetrical (balanced) signal. Once terminated into a coax contact, the inner core will be protected by a shield - but not the outer contact. Because of EMI issues, the signal will no longer be balanced. Conclusion - it does not work and is not recommended. The Quadrax contact is used in railway applications because of the use of quad cable. In this specific market, the standard Ethernet twisted pairs wires cannot be offered, they are too thin and often solid (not stranded). In the rest of industry, UTP (Unshielded Twisted Pairs) cables are widely used. The Quadrax contact is not designed to terminate them. And thus, are not advised for industrial applications. Conclusion To carry 100Mb/s data signal, 100BaseTX or Fast Ethernet recommends the use of Cat5e connectors as well as Cat5e cable with the support of a 100MHz signal. Nevertheless, a 100Mb/s signal can be transmitted in certain conditions (short distance, only one connector, lower frequency but a different code) thru many other connection materials - not necessarily Cat5e rated. 165 Technical Information What about using Quadrax contacts ? UTO SERIES (c) 2013 SOURIAU - SOURIAU is a registered trademark UTO Series Appendices #16 Coaxial Contacts/Cabling Notices .................................................................. 168 Glossary of Terms ................................................................................................... 175 Drilling Pattern ....................................................................................................... 176 Discrimination/Keying Methods ............................................................................. 178 Part Number Index ................................................................................................. 181 167 UTO Series | Appendices #16 Coaxial Contacts Coaxial Cable - Contact Monocrimp and Multipiece Cable type 168 O over jacket Impe- Contact dance type O over dielectric inch mm inch mm Inner cond size O outer braid Ext. O mm inch mm - - Male contact kit for coaxial cable RG161/U 75 0.09" 2.29 0.057" 1.45 - RG179A/U 75 0.105" 2.67 0.063" 1.6 0.3 0.084" 2.13 max RG179B/U 75 0.105" 2.67 0.063" 1.6 0.3 0.084" 2.13 max RG187/U 75 0.11" 2.79 max 0.06" 1.52 0.3 RG188/U 50 0.11" 2.79 max 0.06" 1.52 0.51 0.078" 1.98 max RG174/U 50 0.11" 2.92 0.06" 1.52 0.48 0.088" 2.24 max AMPHENOL 21-598 50 0.105" 2.67 0.06" RG196/U 50 0.08" 2.03 max RG178A/U 50 0.075" Multi piece 1.52 0.48 - - 0.034" 0.086 0.3 - -- 1.91 0.034" 0.86 0.3 0.054" 1.37 max Female contact kit for coaxial cable RMDXK10D28 RCDXK1D28 RMDX6036D28 RCDX6036D28 RG/188A/U 50 0.110" 2.79 0.06" 1.52 0.51 0.078" 1.98 max KX21TVT (europe) RG178 B/U 50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max RMDX6034D28 RCDX6034D28 RG178 / BU 50 0.075" 1.91 0.034" 0.86 0.3 0.054" 1.37 max RMDX6050D28 RCDX6016D28 0.115" 2.92 0.06" 1.52 0.48 0.088" 2.24 max RMDX6032D28 RCDX6032D28 0.11" 2.79 0.06" 1.52 0.51 0.078" 1.98 max RMDX6036D28 RCDX6036D28 RMDX6036D28 RCDX6036D28 RG174/U 50 RG188A/U 50 Mono crimp RG316/U 50 0.107" 2.72 0.06" 1.52 0.51 0.078" 2.05 max raychem 5024A3111 50 0.12" 3.05 0.083" 2.11 0.64 0.097" 2.46 raychem 5026e1614 50 0.083" 2.11 0.05" 1.27 0.48 0.067" 1.7 RMDX6036D28 RCDX6036D28 0.1" 2.54 0.058" 1.47 0.3 - - RMDXK10D28 RCDXK1D28 0.103" 2.62 0.06" 1.52 0.51 0.078" 1.98 surprenant pn 8134 - PRD PN 247ASC1123-001 - Multi piece RMDX6052D28 RMDX6018D28 RMDX6018D28 RCDX6052D28 RCDX6018D28 RCDX6018D28 PRD PN 247AS-C1251 - 0.092" 2.34 0.05" 1.27 0.64 0.067" 1.7 JUDD C15013010902 - 0.087" 2.13 0.05" 1.27 0.48 0.066" 1.67 RMDX6036D28 RCDX6036D28 CDC PIN22939200 - 0.09" 2.29 0.048" 1.22 0.3 0.064" 1.63 RMDX6046D28 RCDX6016D28 CDC PIN22939200 - 0.09" 2.29 0.048" 1.22 0.3 0.064" 1.63 RMDX6050D28 RCDX6016D28 CDC PIN245670000 - 0.104" 2.64 0.067" 1.7 0.3 0.083" 2.11 RMDX6050D28 RCDX6016D28 ampex - 0.114" 2.9 0.075" 1.91 0.38 0.09" 1.29 RMDX6032D28 RCDX6032D28 TI PN 920580 - 0.7" 1.78 0.038" 0.96 0.48 0.054v 1.37 RMDX6024D28 RCDX6024D28 0.096" 2.44 RMDX6026D28 RCDX6026D28 - 2.11 RMDX6050D28 Mono crimp Honeywell PN 58000062 - 0.12" 3.05 0.077" 1.96 0.41 solid - - 0.104" 2.64 0.067" 1.7 0.3 - - - 0.09" 2.29 0.048" 1.22 0.3 - 1.63 RMDX6050D28 - - 0.114" 2.9 0.075" 1.91 0.38 - 1.29 RMDX6032D28 - - - 0.07" 1.78 0.038" 0.96 0.48 - 1.37 RMDX6024D28 RCDX6024D28 - - 0.12" 3.05 0.077" 1.96 0.41 - 2.44 RMDX6026D28 RCDX6026D28 RCDX6032D28 UTO Series | Appendices Cable type Contact type Inner AWG cond O over jacket (single wire) O outer braid Inner cond size inch mm Stranded definition Ext. O mm inch mm Male contact kit for coaxial cable Female contact kit for coaxial cable 2#24 stranded MIL-W-16878 type B 24 0.049" 1.24 max 7/.008 - - RMDXK10D28 RCDXK1D28 2 #24 solid MIL-W-76 type LW 24 0.047" 1.12 max 1/.0201 - - RMDXK10D28 RCDXK1D28 26 0.043" 1.09 max 7/.0063 - - RMDXK10D28 RCDXK1D28 28 0.028" 0.71 max - - RMDXK10D28 RCDXK1D28 Twisted pair 1/.201 solid MIL-W-76 type LW or MIL-W-16878 26 0.044" 1.12 max 1/.0201 0.511 - - RMDXK10D28 RCDXK1D28 Twisted pair solid MIL-W-81822/3 28 0.028" 0.71 max 1/.0126 0.32 - - RMDXK10D28 RCDXK1D28 #28 7/.0036 per Hitachi spec ec-711 (13-2820) - 0.046" 1.17 7/.0036 - - - RMDX6031D28 + RCDX6031D28 + YORX090 YORX090 20218201 - 0.028" 0.71 - - - - RMDX6031D28 + RCDX6031D28 + YORX090 YORX090 #30 solid - 0.025" 0.64 - - - - RMDX6015D28 + RCDX6015D28 + YORX090 YORX090 #26 7/.0063 26 0.028" 0.71 7/.063 0.16 - - RMDX6031D28 + RCDX6031D28 + YORX090 YORX090 #26 19/.004 26 0.049" 1.24 19/.004 - - - RMDX6019D28 + RCDX6019D28 + YORX090 YORX090 24 0.049" 1.24 7/.008 - - - RMDX6019D28 + RCDX6019D28 + YORX090 YORX090 #24 19/.005 24 0.057" 1.45 19/.005 - - - RMDX6019D28 + RCDX6019D28 + YORX090 YORX090 - 26 - 1.25 - - - 19x0.1 RMDX6019D28 + RCDX6019D28 + YORX090 YORX090 - 24 - 1.25 - - - 7x0.2 RMDX6019D28 + RCDX6019D28 + YORX090 YORX090 - 24 - 1.45 - - - 19x0.13 RMDX6019D28 + RCDX6019D28 + YORX090 YORX090 - 26 - 0.7 - - - 7x0.16 RMDX6031D28 + RCDX6031D28 + YORX090 YORX090 2 #26 stranded MIL-W-76 type LW or MIL-W-16878 type B&E 2 #28 solid MIL-W-81822/3 #24 7/.008 Multi piece Mono crimp 0.16 Appendices Twisted Cable - Contact Monocrimp and Multipiece 169 UTO Series | Appendices #16 Coaxial Contacts (Continued) Twisted Pair Cable Multipiece Contact Cabling Cable reference Contact type Male contact Female contact Crimp tool Die set Stop bushing - - Cable strip length A B C Inner conductor crimp g dim t dim Braid crimp g dim t dim 2#24 stranded mil w 16878 type B 2 #24 solid mil-w-76 type LW 2 #26 stranded mil w 76 type LW or mil w16878 type B & E Multi piece 2 #28 solid mil-w-81822/3 RMDXK10D28 RCDXK1D28 M10S1J See assembly notice twisted pair 1/.201 solid mil w 76 type LW or mil w 16878 twisted pair solid mil w 81822/3 Female contact 6.350.41 Strip lengths of cable Outer hyring YOC074 Twisted pair adapter Inner supporting sleeve YORK-090 RCDXB-055-1 Outer female contact Inner pin RCDX60-2 RMD26L-1 Conductor "W" 7.950.41 13.490.41 Conductor "X" Step 1: Step 2: Step 3: Twisted pair adapter Supporting sleeve Outer hyring Male contact Outer male contact Inner socket RMDX60-2 RFD26L-1 Inner supporting sleeve RMDXB-055-3 Outer hyring Twisted pair adapter YORK-090 7.950.41 YOC074 Conductor "Y" Strip lengths of cable Conductor "Z" 7.950.41 15.540.41 Step 1: Step 2: Twisted pair adapter Step 3: Locking louver typical 7.54 0.41 5.94 Inner supporting sleeve Outer hyring Grounding louver typical 0.250.05 7.540.41 When using solid wire flatten conductor "X" and "Z" using N24FL-1 die as shown 7.950.41 15.540.41 Note : all dimensions are in mm 170 UTO Series | Appendices Twisted Pair Cable Monocrimp Contact Cabling Contact type Cable reference Male contact Female contact Crimp tool #28 7/.0036 per Hitachi spec ec-711 (13-2820) Die set S80 Stop bushing Cable strip length A B C 4.7 SL105 6.1 Inner conductor crimp g dim t dim Braid crimp g dim t dim 3.07 to 2.9 4.32 1.30 to 1.12 1.4 to 1.22 2.97 to 2.84 1.4 to 1.22 2.97 to 2.84 3.07 to 2.79 20218204 S80 SL105 3.94 6.1 3.16 1.30 to 1.17 #30 solid S83 SL105 4.7 6.1 4.06 1.22 to 1.12 1.35 to 1.22 2.97 to 2.84 3.12 to 2.95 #26 7/.0063 S80 SL105 4.7 6.1 4.06 1.30 to 1.17 1.4 to 1.22 2.97 to 2.84 3.07 to 2.9 1.35 to 1.22 2.84 to 2.79 3.12 to 2.97 Mono crimp #26 19/.004 RMDX6031D28 + YORX090 #24 7/.008 RCDX6031D28 + YORX090 M10S1J M10SG8 ASSY'Y TOOL DIE SET STOP BUSHING M10S1J TOOL #24 19/.005 4.7 6.1 4.06 1.22 to 1.17 4.7 6.1 4.06 1.22 to 1.17 1.35 to 1.22 2.84 to 2.79 3.12 to 2.97 4.7 6.1 4.06 1.22 to 1.17 1.35 to 1.22 2.84 to 2.79 3.12 to 2.97 4.7 6 4 AWG26 (19x0.1) M10SG8 crimping kit AWG24 (7x0.2) AWG24 (19x0.13) AWG26 (7x0.16) S80 SL105 * Select appropriate monocrimp coax twisted pair contact and cable combination. * Select appropriate crimp tooling (hand tool, S-die set, stop bushing). * Strip the twisted pair cable to the designated wire strip lengths. * Insert the stripped cable into the contact. One cable is to be inserted into the inside diameter of hyring, and pushed forward into the inner contact. The second cable is to be inserted between the outside diameter of hyring and the inside diameter of the outer contact body. * Crimp the contact. See cable strip lengths RMDX60 Male coax contact Cable strip length B C RCDX60 Female coax contact A 16 min. G G Inner conductor crimp (G) to be measured with die set fully closed Appendices Braid crimp (G) to be measured with die set fully closed Note : all dimensions are in mm 171 UTO Series | Appendices #16 Coaxial Contacts (Continued) Multipiece Male Contact with Coax Cable Cable reference RG161U RG179 RG187U RG188/U RG174/U RG178A/U RG196U Hyring complementary compoments Contact Outer contact crimp tool Inner contact crimp tool Crimp tool M10S1J Crimp tool M10S1J Die set Stop bushing Die set A B C 4.37 7.95 15.88 4.37 7.95 15.88 4.37 7.95 15.88 4.37 7.95 15.88 4.37 7.95 15.88 7.54 9.12 17.53 7.54 9.12 17.53 - 4.37 7.95 15.88 - 4.37 7.95 15.88 S23D2 S26D2 Male: RMDXK10D28 S221 YOC074 + RMDXB0553 21-598 SL471 SL46D2 S23D2 YOC074 surprenant pn 8134 Multipiece kit details includes Stop bushing YOC074 AMPHENOL RMDXK10D28 Cable strip length Cable strip length RMDX602D28 Outer contact RFD26L1D28 Inner contact YOC074 Outer hyring RMDXB0553 Inner supporting sleeve A Dielectric diameter B C Contact assembly with dielectric diameter over 1.4mm - without inner supporting sleeve 15.880.41 Outer male contact Inner socket RMDX60-2 RFD26L-1 Step 1: - Assemble outer hyring onto cable - Assemble inner socket to inner conductor and crimp Outer hyring YOC074 Step 2: - Insert the assembly into the outer male contact until the inner socket snaps into place - The cable braid (shield) should now cover the barrel of the outer male contact as shown 0.41 7.95 Strip lengths of cable 4.370.41 Step 3: - Slide outer hyring forward against spring and crimp in place as shown Locking louver typical Grounding louver typical Contact assembly with dielectric diameter under 1.4mm - with inner supporting sleeve Outer male contact Inner socket RMDX60-2 RFD26L-1 Step 1: - Assemble outer hyring onto cable - Assemble supporting sleeve over dielectric and under braid - Assemble inner socket to inner conductor, push back against sleeve and crimp Supporting sleeve Note : all dimensions are in mm 172 Outer hyring Inner supporting sleeve RMDXB-055-3 Step 2: - Insert the assembly into the outer male contact until the inner socket snaps into place - The cable braid (shield) should now cover the barrel of the outer male contact as shown Outer hyring 17.530.41 0.41 9.12 YOC074 7.540.41 Strip lengths of cable Step 3: - Slide outer hyring forward against spring and crimp in place as shown Locking louver typical Grounding louver typical UTO Series | Appendices Multipiece Female Contact with Coax Cable Cable reference RG161U RG179 RG187U RG188/U RG174/U RG178A/U RG196U Hyring complementary compoments Contact Outer contact crimp tool Inner contact crimp tool Crimp tool M10S1J Crimp tool M10S1J Die set Stop bushing Die set Stop bushing S23D2 S26D2 Female: RCDXK1D28 21-598 S221 YOC074 + RMDXB0553 SL471 B 11.13 4.37 11.13 4.37 11.13 4.37 11.13 4.37 SL46D2 S23D2 C 4.37 6.35 11.13 - 11.13 6.35 11.13 - 4.37 11.13 - 4.37 11.13 YOC074 surprenant pn 8134 Cable strip length Multipiece kit details includes A YOC074 AMPHENOL RCDXK1D28 Cable strip length RCDX602D28 Outer contact RMD26L1D28 Inner contact YOC074 Outer hyring RCDXB0553 Inner supporting sleeve A Dielectric diameter B C Contact assembly with dielectric diameter over 1.4mm - without inner supporting sleeve Outer hyring 11.130.41 YOC074 Strip lengths of cable 0.41 4.37 Step 1: - Assemble outer hyring onto cable - Assemble inner pin to inner conductor and crimp Inner pin Outer female contact RMD26L-1 RCDX60-2 Step 2: - Insert the assembly into the outer female contact until the inner pin snaps into place - The cable braid (shield) should now cover the barrel of the outer female contact as shown Step 3: - Slide outer hyring forward against spring and crimp in place as shown Contact assembly with dielectric diameter under 1.4mm - with inner supporting sleeve YOC074 0.41 6.35 Step 1: - Assemble outer hyring onto cable - Assemble supporting sleeve over dielectric and under braid - Assemble inner pin to inner conductor, push back against sleeve and crimp Outer hyring Supporting sleeve Inner pin Outer female contact RCDXB-055-1 RMD26L-1 RCDX60-2028 Step 2: - Insert the assembly into the outer female contact until the inner pin snaps into place - The cable braid (shield) should now cover the barrel of the outer female contact as shown Step 3: - Slide outer hyring forward against spring and crimp in place as shown Appendices Outer hyring 11.130.41 Strip lengths of cable Supporting sleeve Note : all dimensions are in mm 173 UTO Series | Appendices #16 Coaxial Contacts (Continued) Coax Cable with Monocrimp Contact Cabling Cable reference Male contact Female contact CDC PIN22939200 RMDX6046D28 CDC PIN22939200 CDC PIN245670000 KX21TVT (europe) RG178 B/U Cable strip length Inner conductor crimp g dim t dim Braid crimp Die set Stop bushing A B C g dim t dim RCDX6016D28 S80 SL105 4.19 5.97 8.51 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84 RMDX6046D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84 RMDX6050D28 RCDX6016D28 S80 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95 S82 SL105 5.08 6.35 8.89 1.30/1.17 1.32/1.17 2.84/2.74 3.07/2.9 RMDX6034D28 Crimp tool RCDX6034D28 RG178 / BU RMDX6050D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84 ampex RMDX6032D28 RCDX6032D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95 TI PN 920580 RMDX6024D28 RCDX6024D28 S82 SL105 5.08 6.35 8.89 1.35/1.19 1.42/1.27 2.87/2.74 3.07/2.9 RG174/U RMDX6032D28 RCDX6032D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95 Honeywell PN 58000062 RMDX6026D28 RCDX6026D28 S82 SL105 5.08 6.35 8.89 1.35/1.19 1.42/1.27 2.87/2.74 3.07/2.9 RG188A/U RMDX6036D28 RCDX6036D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95 RG316/U RMDX6036D28 RCDX6036D28 S80 SL105 5.08 6.35 11.68 1.30/1.17 1.40/1.22 2.97/2.84 3.12/2.95 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97 5.08 6.35 11.68 1.37/1.27 1.45/1.32 2.92/2.79 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97 5.08 6.35 8.89 1.22/1.17 1.35/1.22 2.92/2.79 3.12/2.97 PRD PN 247AS-C1123-001 RMDX6018D28 RCDX6018D28 PRD PN 247AS-C1251 RMDX6018D28 RCDX6018D28 raychem 5024A3111 RMDX6052D28 RCDX6052D28 M10S1J M10SG8 ASSY'Y TOOL DIE SET STOP BUSHING M10S1J TOOL S88 SL105 raychem 5026e1614 RMDX6036D28 RCDX6036D28 JUDD C15013010902 RMDX6036D28 RCDX6036D28 inner cond. #30, braid diam 2.64 RMDX6050D28 - S80 SL105 5.1 6.35 8.9 - - - - inner cond. #30, braid diam 2.29 RMDX6050D28 - S87 SL105 4.2 6.35 8.5 - - - - inner cond. #28, braid diam 2.9 RMDX6032D28 RCDX6032D28 S80 SL105 5.1 6.35 11.7 - - - - inner cond. #26, braid diam 1.78 RMDX6024D28 RCDX6024D28 S82 SL105 5.1 6.35 8.9 - - - - inner cond. #26, braid diam 3.05 RMDX6026D28 RCDX6026D28 S82 SL105 5.1 6.35 8.9 - - - - M10SG8 ASSY'Y TOOL DIE SET STOP BUSHING M10S1J TOOL * Select appropriate cable and contact combination. * Select appropriate crimp tooling (hand tool, S-die set, stop bushing). * Strip coax cable to the designated wire strip lengths. * Insert the stripped coax into the rear of the contact. * Crimp the contact. See cable strip lengths Cable strip length RMDX60 Male coax contact A RCDX60 Female coax contact B C Note : all dimensions are in mm 174 UTO Series | Appendices Glossary of Terms * Clearance Per the IEC 60664-1 it is the shortest distance between two conductive parts even over the air. * Creepage distance Per the IEC 60664-1 it represents the shortest distance along the surface of the insulating material between two conductive parts. * CTI (Comparative Tracking Index) The CTI value is commonly used to characterise the electrical breakdown properties of an insulating material. It allows users to know the tendency to create creepage paths. This value represents the maximum voltage after 50 drops of ammonium chloride solution without any breakdown. Air gap Creepage distance * Working voltage Per the IEC 60664-1 it is the highest r.m.s. value of A.C. or D.C. voltage across any particular insulation which can occur when the equipment is supplied at rated voltage. * Rated impulse voltage Impulse withstands voltage value assigned by the manufacturer to the equipment or to a part of it characterizing the specified withstand capability of its insulation against transient overvoltage. * RTI (Relative temperature Index): Extract from ULs website: Maximum service temperature for a material, where a class of critical property will not be unacceptably compromised through chemical thermal degradation, over the reasonable life of an electrical product, relative to a reference material having a confirmed, acceptable corresponding performance defined RTI. - RTI Elec: Electrical RTI, associated with critical electrical insulating properties. - RTI Mech Imp: Mechanical Impact RTI, associated with critical impact resistance, resilience and flexibility properties. - RTI Mech Str: Mechanical Strength (Mechanical without Impact) RTI, associated with critical mechanical strength where impact resistance, resilience and flexibility are not essential. * Working current It is the maximum continuous and not interrupted current able to be carried by all contacts without exceeding the maximum temperature of the insulating material. Appendices * Transient voltage Extract from the IEC 60664-1: Short duration overvoltage of a few millisecond or less, oscillatory or non-oscillatory, usually highly damped. 175 UTO Series | Appendices Drilling Pattern Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm Dimensions (mm) 106 103W3 0.8 1.6 3 102W2 3 104 3 103 3.1 Shell Size 2.6 3 2.6 2.8 3 3 124 3 3 2.5 1210 2 1.6 4 0.9 3 3.1 128 2.5 3 3.3 3 1.5 0.7 10 4.4 3.1 142G1 3.4 4.9 3.6 6.4 5.3 2.4 0.4 4.2 5.2 148 5.2 147 2.1 3.6 3.3 2.5 3.1 3 3.1 2.8 4.5 12 3.2 2 4.5 5 14 1492 1419 5.3 5.1 1.4 0.8 2.6 4.9 5.7 6.6 4.6 1.9 2.3 4.5 1 2.2 5.9 176 5.8 3.6 2.4 0.7 5.9 2.2 3.8 5.7 2.9 1.4 1 2 0.3 5.5 5.1 2.8 1412 1.6 3.3 UTO Series | Appendices Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm Dimensions (mm) 1626 7.7 2.3 1.6 2. 1 3.3 1.7 7.4 7.5 3.8 8.1 6 4.4 6.5 5.4 1619 4.5 Shell Size 7.5 1.7 3 4.8 4.5 8 7 1823 1832 8.7 5.3 3.1 2.4 8.3 6.7 7.2 4.8 1.6 3.7 1.6 4.4 5.7 7.7 8.9 6.7 8.5 9.1 5.5 4 4.9 2.4 5.6 2.4 3.3 6.1 8.1 9 Appendices 3.5 4.8 3.4 8.6 18 0.8 5.8 3.8 7.7 1.9 5.4 5 7.9 4 0.8 0.9 1 5.1 2.7 6.6 3.8 2.8 16 177 UTO Series | Appendices Drilling Pattern (Continued) Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm Shell Size Dimensions (mm) 2028 2030 5.2 7.1 10.1 9.3 7 9.2 10 6.2 5.8 6 1.9 3.4 4.7 3.7 7.1 6.7 10.1 8.5 6.2 1.6 3.2 1.7 3.8 3.2 5.3 2.9 2.3 6.2 0.8 4.0 3.4 10.6 3.3 0.8 6.3 6.9 9.2 5.9 2.5 10 1.9 2041 4.2 6 10.1 20 4.2 3.8 5.7 7 0.6 0.5 5.8 3.8 0.5 0.6 3.4 9.3 7.1 3.8 1.5 7.2 1.5 1.6 8.5 2.5 1.6 2.2 4.9 10.6 5.4 4.9 2.5 10.1 3.8 5.4 2235 2238 6.7 5.5 3.9 0.3 2.2 5.7 9.6 178 1.6 4.9 8.2 11.5 3.7 7.8 9.7 11.2 7.1 8.5 10.6 11.5 6.7 7.9 7.8 9.1 10.2 11 4.6 11.4 11.6 6.3 8.4 10.1 3.9 6.2 8.1 0.9 4.2 6 1.9 2.2 3.9 3.3 2.8 0.1 22 1.9 2.5 1.4 11.6 6.5 5.5 1.9 UTO Series | Appendices Hole sizes: #20=0.9mm, #16=1.3mm, #8=3.8mm Shell Size Dimensions (mm) 5.7 11.4 6.6 4.9 1.6 9.9 11.5 22 3.3 8.2 2255 2.8 8.5 11.4 3.8 7.6 9.5 1.9 5.7 13.3 2448 2461 12.3 10.4 6.6 13.2 10.1 9.1 7.9 4.9 3.3 9.9 13.3 7.2 6.0 4.3 3.7 2.6 1.7 3.3 3.4 9.2 11.5 6.5 6.7 9.3 9.9 11.5 11.5 12.9 Appendices 5.7 6.3 8.6 13.1 13.6 2.5 3.1 5 5.6 7.1 8.5 1.1 0.2 0.7 4.1 7.2 9.6 9.9 11.9 4.4 2.3 1 5.8 3.5 3.3 12.7 11 8.7 6.7 5.9 5.4 10.2 7.9 24 13.6 179 UTO Series | Appendices Discrimination/Keying Methods In applications where similar connectors are used next to each other, mismatching can cause disturbances, system failure or even danger to operating personnel. To eliminate mismatching, all Trim Trio(R) connectors are offered with discrimination keys to avoid interconnection system errors. In addition, the connector insert can also be rotated inside the shell to create custom keying options. Shell size 10 12 14 16 18 Connectors with rotated inserts can be ordered by adding the suffix W, X, Y or Z to the standard part number. 20 e.g. UT0W0106PH (standard key) UT0W0106PWH (W key) Consult us for Overmoulded harnesses. 22 24 Layout Discrimination key degrees W X Y Z 103 - - - - 102W2 - - - - 104 45 - - - 103W3 - - - - 106 90 - - - 124 - - - - 128 26 - - - 1210 60 155 270 295 142G1 - - - - 147 - - - - 148 - - - - 1412 60 - - - 1492 49 71 145 - 1419 30 165 315 - 1619 30 165 - 315 1626 60 - 275 338 1823 - 158 - 270 1832 85 138 222 265 2028 79 - 259 - 2030 34 90 123 259 2041 45 126 225 - 2235 13 162 198 265 2238 15 47 150 331 2255 30 142 226 314 2448 60 120 189 351 2461 90 180 270 324 SMSPKE0 (only for UTO layouts using #16 contacts) When one of these dummy contacts is used, the UTO connector will only mate with a connector which has a vacant cavity at the corresponding position. The material used is polyamide 6.6. 180 SMSPKE0 UTO Series | Appendices Connectors UT00102W2PH................... UT00102W2PH6.................. UT00102W2SH................... UT00102W2SH6.................. UT00103PH..................... UT00103PH6.................... UT00103SH..................... UT00103SH6.................... UT00103W3PH................... UT00103W3PH6.................. UT00103W3SH................... UT00103W3SH6.................. UT00104PH..................... UT00104PH6.................... UT00104SH..................... UT00104SH6.................... UT00124PH..................... UT00124PH6.................... UT00124SH..................... UT00124SH6.................... UT00128PH..................... UT00128PH6.................... UT00128SH..................... UT00128SH6.................... UT001412PH.................... UT001412PH6................... UT001412SH.................... UT001412SH6................... UT00142G1PH................... UT00142G1PH6.................. UT00142G1SH................... UT00142G1SH6.................. UT00147PH..................... UT00147PH6.................... UT00147SH..................... UT00147SH6.................... UT00148PH..................... UT00148PH6.................... UT00148SH..................... UT00148SH6.................... UT001492PH.................... UT001492PH6................... UT001492SH.................... UT001492SH6................... UT001619PH.................... UT001619PH6................... UT001619SH.................... UT001619SH6................... UT001823PH.................... UT001823PH6................... UT001823SH.................... UT001823SH6................... UT002028PH.................... UT002028PH6................... UT002028SH.................... UT002028SH6................... UT002030PH.................... UT002030PH6................... UT002030SH.................... UT002030SH6................... UT002235PH.................... UT002235PH6................... UT002235SH.................... P.32 P.32 P.32 P.32 P.20 P.20 P.20 P.20 P.40 P.40 P.40 P.40 P.36 P.36 P.36 P.36 P.28 P.28 P.28 P.28 P.52 P.52 P.52 P.52 P.64 P.64 P.64 P.64 P.24 P.24 P.24 P.24 P.48 P.48 P.48 P.48 P.56 P.56 P.56 P.56 P.68 P.68 P.68 P.68 P.76 P.76 P.76 P.76 P.80 P.80 P.80 P.80 P.88 P.88 P.88 P.88 P.92 P.92 P.92 P.92 P.100 P.100 P.100 UT002235SH6................... UT002238PH.................... UT002238PH6................... UT002238SH.................... UT002238SH6................... UT002448PH.................... UT002448PH6................... UT002448SH.................... UT002448SH6................... UT06102W2PH................... UT06102W2PH02................. UT06102W2SH................... UT06102W2SH02................. UT06103PH..................... UT06103PH02................... UT06103SH..................... UT06103SH02................... UT06103W3PH................... UT06103W3PH02................. UT06103W3SH................... UT06103W3SH02................. UT06104PH..................... UT06104PH02................... UT06104SH..................... UT06104SH02................... UT06124PH..................... UT06124PH02................... UT06124SH..................... UT06124SH02................... UT06128PH..................... UT06128PH02................... UT06128SH..................... UT06128SH02................... UT061412PH.................... UT061412PH02.................. UT061412SH.................... UT061412SH02.................. UT06142G1PH................... UT06142G1PH02................. UT06142G1SH................... UT06142G1SH02................. UT06147PH..................... UT06147PH02................... UT06147SH..................... UT06147SH02................... UT06148PH..................... UT06148PH02................... UT06148SH..................... UT06148SH02................... UT061492PH.................... UT061492PH02.................. UT061492SH.................... UT061492SH02.................. UT061619PH.................... UT061619PH02.................. UT061619SH.................... UT061619SH02.................. UT061823PH.................... UT061823PH02.................. UT061823SH.................... UT061823SH02.................. UT062028PH.................... UT062028PH02.................. UT062028SH.................... P.100 P.104 P.104 P.104 P.104 P.112 P.112 P.112 P.112 P.32 P.32 P.32 P.32 P.20 P.20 P.20 P.20 P.40 P.40 P.40 P.40 P.36 P.36 P.36 P.36 P.28 P.28 P.28 P.28 P.52 P.52 P.52 P.52 P.64 P.64 P.64 P.64 P.24 P.24 P.24 P.24 P.48 P.48 P.48 P.48 P.56 P.56 P.56 P.56 P.68 P.68 P.68 P.68 P.76 P.76 P.76 P.76 P.80 P.80 P.80 P.80 P.88 P.88 P.88 UT062028SH02.................. UT062030PH.................... UT062030PH02.................. UT062030SH.................... UT062030SH02.................. UT062235PH.................... UT062235PH02.................. UT062235SH.................... UT062235SH02.................. UT062238PH.................... UT062238PH02.................. UT062238SH.................... UT062238SH02.................. UT062448PH.................... UT062448PH02.................. UT062448SH.................... UT062448SH02.................. UT07102W2PH................... UT07102W2PH01................. UT07102W2PH6.................. UT07102W2PH601................ UT07102W2SH................... UT07102W2SH01................. UT07102W2SH6.................. UT07102W2SH601................ UT07103PH..................... UT07103PH01................... UT07103PH6.................... UT07103PH601.................. UT07103SH..................... UT07103SH01................... UT07103SH6.................... UT07103SH601.................. UT07103W3PH................... UT07103W3PH01................. UT07103W3PH6.................. UT07103W3PH601................ UT07103W3SH................... UT07103W3SH01................. UT07103W3SH6.................. UT07103W3SH601................ UT07104PH..................... UT07104PH01................... UT07104PH6.................... UT07104PH601.................. UT07104SH..................... UT07104SH01................... UT07104SH6.................... UT07104SH601.................. UT07124PH..................... UT07124PH01................... UT07124PH6.................... UT07124PH601.................. UT07124SH..................... UT07124SH01................... UT07124SH6.................... UT07124SH601.................. UT07128PH..................... UT07128PH01................... UT07128PH6.................... UT07128PH601.................. UT07128SH..................... UT07128SH01................... UT07128SH6.................... P.88 P.92 P.92 P.92 P.92 P.100 P.100 P.100 P.100 P.104 P.104 P.104 P.104 P.112 P.112 P.112 P.112 P.32 P.32 P.32 P.32 P.32 P.32 P.32 P.32 P.20 P.20 P.20 P.20 P.20 P.20 P.20 P.20 P.40 P.40 P.40 P.40 P.40 P.40 P.40 P.40 P.36 P.36 P.36 P.36 P.36 P.36 P.36 P.36 P.28 P.28 P.28 P.28 P.28 P.28 P.28 P.28 P.52 P.52 P.52 P.52 P.52 P.52 P.52 181 Appendices Part Number Index UTO Series | Appendices Part Number Index (Continued) UT07128SH601.................. UT071412PH.................... UT071412PH01.................. UT071412PH6................... UT071412PH601................. UT071412SH.................... UT071412SH01.................. UT071412SH6................... UT071412SH601................. UT07142G1PH................... UT07142G1PH01................. UT07142G1PH6.................. UT07142G1PH601................ UT07142G1SH................... UT07142G1SH01................. UT07142G1SH6.................. UT07142G1SH601................ UT07147PH..................... UT07147PH01................... UT07147PH6.................... UT07147PH601.................. UT07147SH..................... UT07147SH01................... UT07147SH6.................... UT07147SH601.................. UT07148PH..................... UT07148PH01................... UT07148PH6.................... UT07148PH601.................. UT07148SH..................... UT07148SH01................... UT07148SH6.................... UT07148SH601.................. UT071492PH.................... UT071492PH01.................. UT071492PH6................... UT071492PH601................. UT071492SH.................... UT071492SH01.................. UT071492SH6................... UT071492SH601................. UT071619PH.................... UT071619PH01.................. UT071619PH6................... UT071619PH601................. UT071619SH.................... UT071619SH01.................. UT071619SH6................... UT071619SH601................. UT071823PH.................... UT071823PH01.................. UT071823PH6................... UT071823PH601................. UT071823SH.................... UT071823SH01.................. UT071823SH6................... UT071823SH601................. UT072028PH.................... UT072028PH01.................. UT072028PH6................... UT072028PH601................. UT072028SH.................... UT072028SH01.................. UT072028SH6................... 182 P.52 P.64 P.64 P.64 P.64 P.64 P.64 P.64 P.64 P.24 P.24 P.24 P.24 P.24 P.24 P.24 P.24 P.48 P.48 P.48 P.48 P.48 P.48 P.48 P.48 P.56 P.56 P.56 P.56 P.56 P.56 P.56 P.56 P.68 P.68 P.68 P.68 P.68 P.68 P.68 P.68 P.76 P.76 P.76 P.76 P.76 P.76 P.76 P.76 P.80 P.80 P.80 P.80 P.80 P.80 P.80 P.80 P.88 P.88 P.88 P.88 P.88 P.88 P.88 UT072028SH601................. UT072030PH.................... UT072030PH01.................. UT072030PH6................... UT072030PH601................. UT072030SH.................... UT072030SH01.................. UT072030SH6................... UT072030SH601................. UT072235PH.................... UT072235PH01.................. UT072235PH6................... UT072235PH601................. UT072235SH.................... UT072235SH01.................. UT072235SH6................... UT072235SH601................. UT072238PH.................... UT072238PH01.................. UT072238PH6................... UT072238PH601................. UT072238SH.................... UT072238SH01.................. UT072238SH6................... UT072238SH601................. UT072448PH.................... UT072448PH01.................. UT072448PH6................... UT072448PH601................. UT072448SH.................... UT072448SH01.................. UT072448SH6................... UT072448SH601................. UT0W0106PH.................... UT0W0106PH6................... UT0W0106SH.................... UT0W0106SH6................... UT0W01210PH................... UT0W01210PH6.................. UT0W01210SH................... UT0W01210SH6.................. UT0W01419PH................... UT0W01419PH6.................. UT0W01419SH................... UT0W01419SH6.................. UT0W01626PH................... UT0W01626PH6.................. UT0W01626SH................... UT0W01626SH6.................. UT0W01832PH................... UT0W01832PH6.................. UT0W01832SH................... UT0W01832SH6.................. UT0W02041PH................... UT0W02041PH6.................. UT0W02041SH................... UT0W02041SH6.................. UT0W02255PH................... UT0W02255PH6.................. UT0W02255SH................... UT0W02255SH6.................. UT0W02461PH................... UT0W02461PH6.................. UT0W02461SH................... P.88 P.92 P.92 P.92 P.92 P.92 P.92 P.92 P.92 P.100 P.100 P.100 P.100 P.100 P.100 P.100 P.100 P.104 P.104 P.104 P.104 P.104 P.104 P.104 P.104 P.112 P.112 P.112 P.112 P.112 P.112 P.112 P.112 P.44 P.44 P.44 P.44 P.60 P.60 P.60 P.60 P.72 P.72 P.72 P.72 P.84 P.84 P.84 P.84 P.96 P.96 P.96 P.96 P.108 P.108 P.108 P.108 P.116 P.116 P.116 P.116 P.120 P.120 P.120 UT0W02461SH6.................. UT0W6106PH.................... UT0W6106PH02.................. UT0W6106SH.................... UT0W6106SH02.................. UT0W61210PH................... UT0W61210PH02................. UT0W61210SH................... UT0W61210SH02................. UT0W61419PH................... UT0W61419PH02................. UT0W61419SH................... UT0W61419SH02................. UT0W61626PH................... UT0W61626PH02................. UT0W61626SH................... UT0W61626SH02................. UT0W61832PH................... UT0W61832PH02................. UT0W61832SH................... UT0W61832SH02................. UT0W62041PH................... UT0W62041PH02................. UT0W62041SH................... UT0W62041SH02................. UT0W62255PH................... UT0W62255PH02................. UT0W62255SH................... UT0W62255SH02................. UT0W62461PH................... UT0W62461PH02................. UT0W62461SH................... UT0W62461SH02................. UT0W7106PH.................... UT0W7106PH01.................. UT0W7106PH6................... UT0W7106PH601................. UT0W7106SH.................... UT0W7106SH01.................. UT0W7106SH6................... UT0W7106SH601................. UT0W71210PH................... UT0W71210PH01................. UT0W71210PH6.................. UT0W71210PH601................ UT0W71210SH................... UT0W71210SH01................. UT0W71210SH6.................. UT0W71210SH601................ UT0W71419PH................... UT0W71419PH01................. UT0W71419PH6.................. UT0W71419PH601................ UT0W71419SH................... UT0W71419SH01................. UT0W71419SH6.................. UT0W71419SH601................ UT0W71626PH................... UT0W71626PH01................. UT0W71626PH6.................. UT0W71626PH601................ UT0W71626SH................... UT0W71626SH01................. UT0W71626SH6.................. P.120 P.44 P.44 P.44 P.44 P.60 P.60 P.60 P.60 P.72 P.72 P.72 P.72 P.84 P.84 P.84 P.84 P.96 P.96 P.96 P.96 P.108 P.108 P.108 P.108 P.116 P.116 P.116 P.116 P.120 P.120 P.120 P.120 P.44 P.44 P.44 P.44 P.44 P.44 P.44 P.44 P.60 P.60 P.60 P.60 P.60 P.60 P.60 P.60 P.72 P.72 P.72 P.72 P.72 P.72 P.72 P.72 P.84 P.84 P.84 P.84 P.84 P.84 P.84 UTO Series | Appendices P.84 P.96 P.96 P.96 P.96 P.96 P.96 P.96 P.96 P.108 P.108 P.108 P.108 P.108 P.108 P.108 P.108 P.116 P.116 P.116 P.116 P.116 P.116 P.116 P.116 P.120 P.120 P.120 P.120 P.120 P.120 P.120 P.120 Backshells UT010AC....................... UT010AD....................... UT010JC....................... UT010JCL...................... UT010JCPGN.................... UT010JCS...................... UT010JCSL..................... UT010LPGN..................... UT012AC....................... UT012AD....................... UT012JC....................... UT012JCL...................... UT012JCPGN.................... UT012JCS...................... UT012JCSL..................... UT012LPGN..................... UT014AC....................... UT014AD....................... UT014JC....................... UT014JCL...................... UT014LPGN..................... UT014JCPGN.................... UT014JCSL..................... UT014LPGN..................... UT016AC....................... UT016AD....................... UT016JC....................... UT016JCL...................... UT016JCPGN.................... P.20 P.20 P.20 P.20 P.20 P.20 P.20 P.20 P.28 P.28 P.28 P.28 P.28 P.28 P.28 P.28 P.24 P.24 P.24 P.24 P.24 P.24 P.24 P.24 P.76 P.76 P.76 P.76 P.76 UT016JCS...................... UT016JCSL..................... UT016LPGN..................... UT018AC....................... UT018AD....................... UT018JC....................... UT018JCL...................... UT018JCS...................... UT018JCPGN.................... UT018JCSL..................... UT018LPGN..................... UT020AC....................... UT020AD....................... UT020JC....................... UT020JCL...................... UT020JCS...................... UT020JCPGN.................... UT020JCSL..................... UT020LPGN..................... UT022AC....................... UT022AD....................... UT022JC....................... UT022JCL...................... UT022JCS...................... UT022JCPGN.................... UT022JCSL..................... UT022LPGN..................... UT024AC....................... UT024AD....................... UT024JC....................... UT024JCL...................... UT024JCS...................... UT024JCPGN.................... UT024JCSL..................... UT024LPGN..................... UT0S10JC...................... UT0S10JCL..................... UT0S10JCPGN................... UT0S10JCS..................... UT0S10JCSL.................... UT0S12JC...................... UT0S12JCL..................... UT0S12JCS..................... UT0S12JCPGN................... UT0S12JCSL.................... UT0S14JC...................... UT0S14JCL..................... UT0S14JCPGN................... UT0S14JCS..................... UT0S14JCSL.................... UT0S16JC...................... UT0S16JCL..................... UT0S16JCPGN................... UT0S16JCS..................... UT0S16JCSL.................... UT0S18JC...................... UT0S18JCL..................... UT0S18JCPGN................... UT0S18JCS..................... UT0S18JCSL.................... UT0S20JC...................... UT0S20JCL..................... UT0S20JCPGN................... UT0S20JCS..................... P.76 P.76 P.76 P.80 P.80 P.80 P.80 P.80 P.80 P.80 P.80 P.88 P.88 P.88 P.88 P.88 P.88 P.88 P.88 P.100 P.100 P.100 P.100 P.100 P.100 P.100 P.100 P.112 P.112 P.112 P.112 P.112 P.112 P.112 P.112 P.20 P.20 P.20 P.20 P.20 P.28 P.28 P.28 P.28 P.28 P.24 P.24 P.24 P.24 P.24 P.76 P.76 P.76 P.76 P.76 P.80 P.80 P.80 P.80 P.80 P.88 P.88 P.88 P.88 UT0S20JCSL.................... UT0S22JC...................... UT0S22JCL..................... UT0S22JCPGN................... UT0S22JCS..................... UT0S22JCSL.................... UT0S24JC...................... UT0S24JCL..................... UT0S24JCPGN................... UT0S24JCS..................... UT0S24JCSL.................... P.88 P.100 P.100 P.100 P.100 P.100 P.112 P.112 P.112 P.112 P.112 Accessories SMSPKE0....................... UT010DCG...................... UT012DCG...................... UT014DCG...................... UT016DCG...................... UT018DCG...................... UT020DCG...................... UT022DCG...................... UT024DCG...................... UTFD12B....................... UTFD13B....................... UTFD14B....................... UTFD15B....................... UTFD16B....................... UTFD17B....................... UTFD18B....................... UTFD19B....................... UTG610DCG..................... UTG612DCG..................... UTG614DCG..................... UTG616DCG..................... UTG618DCG..................... UTG620DCG..................... UTG622DCG..................... UTG624DCG..................... P.180 P.22 P.30 P.26 P.78 P.82 P.90 P.102 P.114 P.22 P.30 P.26 P.78 P.82 P.90 P.102 P.114 P.22 P.30 P.26 P.78 P.82 P.90 P.102 P.114 Contacts 82911456A..................... 82911456K..................... 82911457NA.................... 82911457NK.................... 82911458A..................... 82911458K..................... 82911459NA.................... 82911459NK.................... 82911460A..................... 82911460K..................... 82911461NA.................... 82911461NK.................... 82911462A..................... 82911462K..................... 82911463NA.................... 82911463NK.................... 82911464A..................... 82911464K..................... 82911465NA.................... 82911465NK.................... 82911466A..................... 82911466K..................... 82911467NA.................... 82911467NK.................... P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 183 Appendices UT0W71626SH601................ UT0W71832PH................... UT0W71832PH01................. UT0W71832PH6.................. UT0W71832PH601................ UT0W71832SH................... UT0W71832SH01................. UT0W71832SH6.................. UT0W71832SH601................ UT0W72041PH................... UT0W72041PH01................. UT0W72041PH6.................. UT0W72041PH601................ UT0W72041SH................... UT0W72041SH01................. UT0W72041SH6.................. UT0W72041SH601................ UT0W72255PH................... UT0W72255PH01................. UT0W72255PH6.................. UT0W72255PH601................ UT0W72255SH................... UT0W72255SH01................. UT0W72255SH6.................. UT0W72255SH601................ UT0W72461PH................... UT0W72461PH01................. UT0W72461PH6.................. UT0W72461PH601................ UT0W72461SH................... UT0W72461SH01................. UT0W72461SH6.................. UT0W72461SH601................ UTO Series | Appendices Part Number Index (Continued) 82913600A..................... 82913601A..................... 82913602A..................... 82913603A..................... 82913604A..................... 82913605A..................... 82913606A..................... 82913607A..................... 82913608A..................... 82913609A..................... 82911684NPC................... 82911684NAPC.................. 82911685NPC................... 82911685NAPC.................. RC14M30J...................... RC14M30K...................... RC14M30GE7J................... RC14M30GE7K................... RC16M23J...................... RC16M23K...................... RC16M23GE7J................... RC16M23GE7K................... RC18W3K....................... RC20M12J...................... RC20M12K...................... RC20M12E8J.................... RC20M12E8K.................... RC20M12E83J................... RC20M12E83K................... RC20M12E84J................... RC20M12E84K................... RC20M12GE7J................... RC20M12GE7K................... RC20M13J...................... RC20M13K...................... RC20M13GE7J................... RC20M13GE7K................... RC20W3K....................... RC24M9J....................... RC24M9K....................... RC24M9GE7J.................... RC24M9GE7K.................... RC24W3K....................... RC28M1J....................... RC28M1K....................... RC28M1GE7J.................... RC28M1GE7K.................... RCDX60xxD28................... RCDXK1D28..................... RCPOF1000B.................... RCW5016K...................... RCW50A7K...................... RM14M30J...................... RM14M30K...................... RM14M30GE1J................... RM14M30GE1K................... RM16M23J...................... RM16M23K...................... RM16M23GE1J................... RM16M23GE1K................... RM18W3K....................... RM20M12J...................... RM20M12K...................... RM20M12E8J.................... 184 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.132 P.132 P.132 P.132 P.129 P.129 P.130 P.130 P.129 P.129 P.130 P.130 P.129 P.129 P.129 P.132 P.132 P.132 P.132 P.132 P.132 P.130 P.130 P.129 P.129 P.130 P.130 P.129 P.129 P.129 P.130 P.130 P.129 P.129 P.129 P.130 P.130 P.131 P.131 P.130 P.132 P.132 P.129 P.129 P.130 P.130 P.129 P.129 P.130 P.130 P.129 P.129 P.129 P.132 RM20M12E8K.................... RM20M12E83J................... RM20M12E83K................... RM20M12GE1J................... RM20M12GE1K................... RM20M13J...................... RM20M13K...................... RM20M13GE1J................... RM20M13GE1K................... RM20W3K....................... RM24M9J....................... RM24M9K....................... RM24M9GE1J.................... RM24M9GE1K.................... RM24W3K....................... RM28M1J....................... RM28M1K....................... RM28M1GE1J.................... RM28M1GE1K.................... RMDX60xxD28................... RMDXK10D28.................... RMPOF1000..................... RMW5016K...................... RMW50A7K...................... SC14M1S18..................... SC14M1S31..................... SC14M1TK6..................... SC14ML1S18.................... SC14ML1S31.................... SC14ML1TK6.................... SC16M1S18..................... SC16M1S31..................... SC16M1TK6..................... SC16M11S18.................... SC16M11S31.................... SC16M11TK6.................... SC16ML1S18.................... SC16ML1S31.................... SC16ML1TK6.................... SC16ML11S18................... SC16ML11S31................... SC16ML11TK6................... SC20M1S18..................... SC20M1S31..................... SC20M1TK6..................... SC20ML1S18.................... SC20ML1S31.................... SC20ML1TK6.................... SC20W3S25..................... SC20W3TK6..................... SC20WL3S25.................... SC20WL3TK6.................... SC24M1S18..................... SC24M1S31..................... SC24M1TK6..................... SC24ML1S18.................... SC24ML1S31.................... SC24ML1TK6.................... SC24W3S25..................... SC24W3TK6..................... SC24WL3S25.................... SC24WL3TK6.................... SM14M1S18..................... SM14M1S31..................... P.132 P.132 P.132 P.130 P.130 P.129 P.129 P.130 P.130 P.129 P.129 P.129 P.130 P.130 P.129 P.129 P.129 P.130 P.130 P.131 P.131 P.130 P.132 P.132 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 SM14M1TK6..................... SM14ML1S18.................... SM14ML1S31.................... SM14ML1TK6.................... SM16M1S18..................... SM16M1S31..................... SM16M1TK6..................... SM16M11S18.................... SM16M11S31.................... SM16M11TK6.................... SM16ML1S18.................... SM16ML1S31.................... SM16ML1TK6.................... SM16ML11S18................... SM16ML11S31................... SM16ML11TK6................... SM20M1S18..................... SM20M1S31..................... SM20M1TK6..................... SM20ML1S18.................... SM20ML1S31.................... SM20ML1TK6.................... SM20W3S26..................... SM20W3TK6..................... SM20WL3S26.................... SM20WL3TK6.................... SM24M1S18..................... SM24M1S31..................... SM24M1TK6..................... SM24ML1S18.................... SM24ML1S31.................... SM24ML1TK6.................... SM24W3S26..................... SM24W3TK6..................... SM24WL3S26.................... SM24WL3TK6.................... P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 P.129 Tooling 51060210924................... 51060210936................... M10S1J........................ M10SG8........................ M317.......................... MH860......................... MH86164G...................... MH86186....................... RX2025GE1..................... RX20D44....................... S16RCM14...................... S16RCM16...................... S16RCM20...................... S16SCM20...................... S16SCML1...................... S16SCML11..................... S20RCM........................ S20SCM20...................... S221.......................... S23D2......................... S80........................... S82........................... S83........................... S87........................... S88........................... SHANDLES...................... P.139 P.139 P.174 P.174 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.139 P.172 P.172 P.174 P.174 P.171 P.174 P.174 P.139 UTO Series | Appendices P.174 P.172 P.172 P.139 P.139 P.139 Appendices SL105......................... SL46D2........................ SL471......................... UH25.......................... VGE10077A..................... VGE10078A..................... 185 UTO Series | Appendices Notes 186 Our contribution to environmental protection: This catalog is printed on PEFC certified paper Advancement of sustainable wood cultivation. www.pefc.org www.souriau-industrial.com contactindustry@souriau.com CAUTOEUSEN01 (c) Copyright SOURIAU Oct 2013 - SOURIAU is a registered trademark All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing. Photos: Fotolia.com Your local contact