Non-Return Valves T50 Series In Line Push-In Non-Return Valves 4, 6, 8, 10, 12mm OD Metric tube 5 32", 1 4", 5 16", 3 8", 1 2" Inch tube Allow free flow in one direction only Simple reliable design Low weight Low cracking pressure High operating pressure Technical Data Medium: Compressed air, filtered, lubricated and non-lubricated, vacuum Operation Non-Return Valve Operating Pressure: -0.9 to 16 bar (Dependent upon operating specification of tubing) Ordering Information To order, quote appropriate product number from the tables on the following pages. e.g. T50P0010 for Metric tube 10mm OD Alternative Models M,C/520 range of heavy duty brass non-return valves. See page 5.10.001.01 Operating Temperature: -20C* to +80C * Consult our Technical Service for use below +2C Mounting: Line mounted, push-in connection 1 2 Port Size: OD Metric tube OD Inch tube 4mm T50P0004 5/32" T50Y0002 6mm T50P0006 1/4" T50Y0004 8mm T50P0008 5/16" T50Y0005 10mm T50P0010 3/8" T50Y0006 12mm T50P0012 1/2" T50Y0007 Materials Anodized aluminium body, nickel plated brass collet, aluminium valve and insert, stainless steel spring, nitrile rubber seals Tubing Types Nylon 11 or 12. Polyurethane, and other plasticated or unplasticated tubing which conforms to the tolerances specified in BS 5409, part 1, 1976, light and normal duty, DIN 73378, DIN 74234, NFE 49-100. 07/97 Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. N/AL 5.10.002.01 Non-Return Valves General Information Model Metric T50P0004 T50P0006 T50P0008 T50P0010 T50P0012 Tube Size Metric 4 6 8 10 12 Inch T50Y0002 T50Y0004 T50Y0005 T50Y0006 T50Y0007 Flow Factor Cv*/C** 0.09/0.38 0.38/1.57 0.78/3.2 1.103/4.5 1.64/6.7 Inch 5 32 1 4 5 16 3 8 1 2 Cracking pressure bar 0,03 0,03 0,03 0,03 0,03 Weight (gs) 10 16 22 48 64 Spares Kit Not Available Not Available Not Available Not Available Not Available *CV measured in US gall/min **C measured in dm3/(s.bar) Non-return Valve Model T50P or T50Y B C C A Model A B C T50P0004 T50Y0002T50P0006 T50Y0004 T50P0008 T50Y0005 T50P0010 T50Y0006T50P0012 T50Y0007 11,0 11,0 13,0 13,0 15,0 16,0 20,0 20,0 22,0 22,0 49,0 49,0 55,7 55,7 60,9 60,9 77,4 77,4 88,4 88,4 5 32 1 4 5 16 3 8 1 2 4,0 6,0 8,0 10,0 12,0 Flow versus Pressure supply 3 3 Flow measured in dm /(s. bar) Flow measured in dm /(s. bar) 22.5 45 20 40 KEY 17.5 KEY 35 T50P0008 T50P0012 30 15 T50P0006 12.5 T50P0004 T50P0010 25 10 20 7.5 15 5 10 2.5 5 0 0 1 2 3 4 Pressure supply (bar) 5 6 0 0 1 2 3 4 5 6 Pressure supply (bar) Tests conducted at standard reference conditions (ISO6538) Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under `Technical Data'. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/AL 5.10.002.02 Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 07/97