07/97 N/AL 5.10.002.01
Our policy is one of continuous research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
Ordering Information
To order, quote appropriate product number
from the tables on the following pages.
e.g. T50P0010 for Metric tube 10mm ØD
Alternative Models
M,C/520 range of heavy duty brass non-return
valves.
See page 5.10.001.01
Allow free flow in one direction only
Simple reliable design
Low weight
Low cracking pressure
High operating pressure
Technical Data
Medium:
Compressed air, filtered,
lubricated and non-lubricated, vacuum
Operation
Non-Return Valve
Operating Pressure:
-0.9 to 16 bar
(Dependent upon operating specification of tubing)
Operating Temperature:
–20°C* to +80°C
* Consult our Technical Service for use below +2°C
Mounting:
Line mounted, push-in connection
Port Size:
OD Metric tube OD Inch tube
4mm T50P0004 5/32” T50Y0002
6mm T50P0006 1/4” T50Y0004
8mm T50P0008 5/16” T50Y0005
10mm T50P0010 3/8” T50Y0006
12mm T50P0012 1/2” T50Y0007
Materials
Anodized aluminium body, nickel plated brass collet, aluminium
valve and insert, stainless steel spring, nitrile rubber seals
Tubing Types
Nylon 11 or 12. Polyurethane, and other plasticated or
unplasticated tubing which conforms to the tolerances specified
in BS 5409, part 1, 1976, light and normal duty, DIN 73378, DIN
74234, NFE 49-100.
12
Non-Return Valves
T50 Series
In Line Push-In Non-Return Valves
4, 6, 8, 10, 12mm ØD Metric tube
532",14",516",38",12"Inch tube
Model Tube Size Flow Factor Cracking Weight Spares Kit
Metric Inch Metric Inch Cv*/C** pressure bar (gs)
T50P0004 T50Y0002
4532 0.09/0.38 0,03 10 Not Available
T50P0006 T50Y0004
6140.38/1.57 0,03 16 Not Available
T50P0008 T50Y0005
8516 0.78/3.2 0,03 22 Not Available
T50P0010 T50Y0006
10 381.103/4.5 0,03 48 Not Available
T50P0012 T50Y0007
12 121.64/6.7 0,03 64 Not Available
N/AL 5.10.002.02 07/97
Non-Return Valves
Our policy is one of continuous research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where
pressures
and
temperatures
can
exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not
within published specifications, consult Norgren.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to
consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products
where applicable.
General Information
Model T50P0004T50Y0002T50P0006T50Y0004T50P0008T50Y0005T50P0010T50Y0006T50P0012 T50Y0007
A 11,0 11,0 13,0 13,0 15,0 16,0 20,0 20,0 22,0 22,0
B 49,0 49,0 55,7 55,7 60,9 60,9 77,4 77,4 88,4 88,4
C 4,0 532 6,0 148,0 516 10,0 3812,0 12
C
C
B
A
Model T50P or T50Y
Non-return Valve
Tests conducted at standard reference conditions (ISO6538)
Flow versus Pressure supply
12.5
10
7.5
5
2.5
12346
5
15
17.5
20
KEY
T50P0008
T50P0006
T50P0004
Pressure supply (bar)
00
Flow measured in dm /(s. bar)
3
22.5
25
20
15
10
5
12346
5
30
35
40
45
KEY
T50P0012
T50P0010
Pressure supply (bar)
0
0
Flow measured in dm /(s. bar)
3
*CV measured in US gall/min
**C measured in dm3/(s.bar)