Model Tube Size Flow Factor Cracking Weight Spares Kit
Metric Inch Metric Inch Cv*/C** pressure bar (gs)
T50P0004 T50Y0002
45⁄32 0.09/0.38 0,03 10 Not Available
T50P0006 T50Y0004
61⁄40.38/1.57 0,03 16 Not Available
T50P0008 T50Y0005
85⁄16 0.78/3.2 0,03 22 Not Available
T50P0010 T50Y0006
10 3⁄81.103/4.5 0,03 48 Not Available
T50P0012 T50Y0007
12 1⁄21.64/6.7 0,03 64 Not Available
N/AL 5.10.002.02 07/97
Non-Return Valves
Our policy is one of continuous research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where
pressures
and
temperatures
can
exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not
within published specifications, consult Norgren.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to
consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products
where applicable.
General Information
Model T50P0004T50Y0002T50P0006T50Y0004T50P0008T50Y0005T50P0010T50Y0006T50P0012 T50Y0007
A 11,0 11,0 13,0 13,0 15,0 16,0 20,0 20,0 22,0 22,0
B 49,0 49,0 55,7 55,7 60,9 60,9 77,4 77,4 88,4 88,4
C 4,0 5⁄32 6,0 1⁄48,0 5⁄16 10,0 3⁄812,0 1⁄2