Digital Attenuator, 4-Bit, Single Control
30 dB, 0.5 - 2.0 GHz
Rev. V3
MAATSS0016
• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.43537383 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Electrical Specifications4: TA = 25°C, Z0 = 50 Ω, VS = 5 V
Parameter Test Conditions Units Min. Typ. Max.
Reference Insertion Loss 0.5 - 1.0 GHz
0.5 - 2.0 GHz dB
dB —
— 2.0
2.2 2.4
2.7
Attenuation Accuracy 0.5 - 1.0 GHz
0.5 - 2.0 GHz ± (0.15 dB + 5% of attenuation setting in dB) dB
± (0.3 dB + 5% of attenuation setting in dB) dB
VSWR 1.0 - 1.5 GHz
0.5 - 2.0 GHz Ratio
Ratio —
— 1.5:1
1.9:1 —
—
Trise, Tfall 10% to 90% RF, 90% to 10% RF ns — 200 —
Ton, Toff 50% Control to 90% RF,50% Control to 10% RF ns — 200 —
Transients In Band mV — 75 —
1 dB Compression Input Power, 0.5 GHz
Input Power, 0.9 GHz dBm
dBm —
— 25
25 —
—
IP2
0.5 GHz
0.5 - 2.0 GHz
Measured Relative to Input
(for two-tone Input Power up to +5 dBm)
dBm
dBm —
— 65
71 —
—
IP3
0.5 GHz
0.5 - 2.0 GHz
Measured Relative to Input
(for two-tone Input Power up to +5 dBm)
dBm
dBm —
— 43
47 —
—
IC ⏐Vc⏐ = 5 V µA — — 10
IVS — µA — — 20
4. External DC blocking capacitors are required on all RF ports. Loss varies at 0.003 dB/°C.
Absolute Maximum Ratings 5,6
Parameter Absolute Maximum
Input Power
50 MHz
500 - 2000 MHz
+27 dBm
+34 dBm
Control Voltage -0.5 V < VC < 8.5 V
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. M/A-COM does not recommend sustained operation near
these survivability limits.
Truth Table7
VC1 VC2 VC3 VC4 Attenuation (dB)
1 1 1 1 Reference Insertion Loss
1 1 1 0 2
1 1 0 1 4
1 0 1 1 8
0 1 1 1 16
0 0 0 0 30
7. 0 = 0 ± 0.2 V, 1 = +5 V