CL Series
Ratings from 5A and 10A @ 24-280 VAC
Triac Output
LED Status Indicator
UL Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
AC or DC control
EMC Compliant to Level 3
Epoxy Free Design
PRODUCT SELECTION
Control Voltage 5A
3-32 VDC CL240D05
90-250 VAC CL240A05
10A
CL240D10
CL240A10
AVAILABLE OPTIONS
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*
Required for valid part number
For options only and not required for valid part number
Series
Load Voltage
240: 24-280 VAC
Control Voltage
A: 90-250 VAC
D: 3-32 VDC
Switching Type
Blank: Zero Voltage
Turn-On
R: Instantaneous Turn-On
Rated Load Current
05: 5 Amps
10: 10 Amps
Cover
Blank: Not Included (IP00)
C: Included (IP20)
Thermal Pad
Blank: Not Included
H: Included
CL A 10 R C240 H
Termination
Blank: Screws & clamps
K: Installed standoffs with
screws for PC Board
mounting (IP00 only) (1)
K
OUTPUT SPECIFICATIONS (2)
Description 5A
Operating Voltage (47-63Hz) [Vrms] 24-280
Transient Overvoltage [Vpk] (3) 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 7
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500
Maximum Load Current [Arms] (4) 5
Minimum Load Current [mArms] 150
Maximum 1 Cycle Surge Current (50/60Hz)[Apk] 84/100
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6
Thermal Resistance Junction to Case (Rjc) [°C/W] 2.3
Maximum 1/2 Cycle I² t for Fusing (50/60Hz)[A²sec] 35/42
Minimum Power Factor (with Maximum Load) 0.5
10A
24-280
600
7
500
10
150
120/126
1.5
2.3
72/66
0.5
Minimum Heat Sink for Rated Current @ 40°C [°C/W] 3 1.5
INPUT SPECIFICATIONS (2)
Description AC Control
Control Voltage Range 90-250 VAC
Maximum Reverse Voltage -
Minimum Turn-On Voltage 90 VAC
Must Turn-Off Voltage 10 VAC
Minimum Input Current (for on-state) 6 mA
Maximum Input Current 10 mA
Nominal Input Impedance Current Limited
Maximum Turn-On Time [msec] 20
Maximum Turn-Off Time [msec] 30
DC Control
3-32 VDC (5)
-32 VDC
3 VDC
1 VDC
10 mA
14 mA
Current Limited
1/2 Cycle (6)
1/2 Cycle
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
GENERAL SPECIFICATIONS (2)
ParametersDescription
Dielectric Strength, Input to Output (50/60Hz)
Dielectric Strength, Input/Output to Ground (50/60Hz)
4000 Vrms
2500 Vrms
Minimum Insulation Resistance (@ 500 VDC) 109 Ohms
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range (7) -40 to 80 °C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 2.88 oz (81.53 g)
Housing Material UL94 V-0
Baseplate Material Aluminum
Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7
Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
Input/Load Terminal Screw Torque Range (in-lb/Nm) (1) w/”K” option 8-10 / 0.9-1.13
SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
Humidity per IEC60068-2-78 93% non-condensing
LED Input Status Indicator Green
MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 11,641,553 hours (1,328 years)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) 7,210,376 hours (823 years)
WIRING DIAGRAM
Recommended Wire Sizes
Terminals Wire Size
(Solid / Stranded)
Wire Pull-Out
Strength (lbs)[N]
Input
Output
24 AWG (0.2 mm2) / 0.2 [minimum]
2 x 12 AWG (3.3 mm2) / 3.3 [maximum]
20 AWG (0.5 mm2) / 0.518 [minimum]
2 x 10 AWG (5.3 mm2) / 5.3
2 x 8 AWG (8.4 mm2) / 8.4 [maximum]
10 [44.5]
90 [400]
30 [133]
110 [490]
90 [400]
1
4
2
3
SOLID STATE RELAY
OUTPUT
INPUT
Load (9)
V
4 ( / )3 (+ / )
1 ( ) 2 ( )
AC
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
+DC
-
DC
AC
Trigger
Circuit
Current
Limiter
AC
3
4
2
1
INPUT
OUTPUT
CL Series DC Control
AC
AC
AC
Trigger
Circuit
Current
Limiter
AC
3
4
2
1
INPUT
OUTPUT
AC/DC
Converter
CL Series AC Control
0
2
4
6
8
10
12
14
0 5 10 15 20 25 30 35
Input Current vs Input Voltage
Standard Regulated “DC” Inputs
Input Current (mA)
DC Input Voltage
Input Current vs Input Voltage
Standar Regulated “AC” Inputs
Input Current (mA)
AC Input Voltage
0
1
2
3
4
5
6
7
0 50 100 150 200 250
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC
MECHANICAL SPECIFICATIONS (2)
GENERAL NOTES
(1)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Screw Termination
1OUTPUT 2
SOLID STATE RELAY
4INPUT 3
1.1
[27.9]
0.49
[12.4]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
0.89
[22.6]
1.88
[47.6]
1.7
[43.2]
2.25
[57.3]
1.0
[25.4]
1.75
[44.5]
1.0
[25.4]
1.75
[44.5]
Hex Standoff Termination (“K” Option)
1OUTPUT 2
SOLID STATE RELAY
4INPUT 3
1.1
[27.9]
0.49
[12.4]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.88
[47.6]
1.7
[43.2]
2.25
[57.3]
1.0
[25.4]
1.75
[44.5]
1.04
[26.4]
(4 places)
0.93
[23.6]
1.0
[25.4]
(2 places)
(2 places)
Mounting
Hole/Slot
0.19 [4.9]
DIA.
2.25
[57.3]
1.1
[27.9]
0.49
[12.4]
1.88
[47.6]
1.7
[43.2]
2.32
[58.8]
1.0
[25.4]
1.75
[44.5]
1.0
[25.4]
1.75
[44.5]
1.22
[30.9]
Screw Termination, IP20
(1) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm).
(2) All parameters at 25°C unless otherwise specified.
(3) Output will self trigger between 450-600Vpk, not suituable for capacitive loads.
(4) Heat sinking required, see derating curves.
(5) Increase minimum voltage by 1V for operations from -20 to -40°C.
(6) Turn-on time for instantaneous turn-on versions is 0.1 msec.
(7) AC models operating range is -20 to 80 °C.
(8)
All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(9) Load can be wired to either SSR output terminal 1 or 2.
(10)
For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC Rms value of surge current equals the peak value divided by
2 (1.414).
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
SURGE CURRENT INFORMATION
THERMAL DERATE INFORMATION
(i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air.
0
20
40
60
80
100
120
0.01 0.1 1 10
Surge Current (Amp) AC Peak
Surge Duration (sec)
CL240x10
0
10
20
30
40
50
60
70
80
90
0.01 0.1 1 10
Surge Current (Amp)
AC Peak
Surge Duration (sec)
CL240x05
Single Pulse (10)
0
1
2
3
4
5
20 30 40 50 60 70 80
CL240x05
Load Current (Amps)
Ambient Temperature (ºC)
2°C/W 3°C/W No Heat Sink (i)
0
2
4
6
8
10
20 30 40 50 60 70 80
CL240x10
Load Current (Amps)
Ambient Temperature (ºC)
1.5°C/W 2°C/W No Heat Sink (i)
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
AGENCY APPROVALS
EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
IEC 61000-4-2 Electrostatic Discharge Level 3
IEC 61000-4-4 Electrically Fast Transients Level 3
IEC 61000-4-5 Electrical Surges Level 3
E46203
Part number: KS101
Clear plastic cover compatible with all new
S1 designs. Safety covers provide added
protection from electric shock when
installing or checking equipment.
Protective Cover
Hardware Kit
Part number: HK4
Bag with 2 square brass accessories and 2
screw 8-32 x 5/8 for output. Used to mount
TMR1 lug terminals.
New Accessories!
Protective Cover & Hardware Kits
Recommended Accessories
Cover Hardware
Kit
Heat Sink
Part No.
Thermal Resistance
[ºC/W]
Lug Terminal Thermal Pad
KS101 HK1
HK4
HS501DR
HS301 / HS301DR
HS251
HS201 / HS201DR
HS202 / HS202DR
HS172
HS151 / HS151DR
HS122 / HS122DR
HS103 / HS103DR
HS101
HS073
HS072
HS053
HS033
HS023
5.0
3.0
2.5
2.0
2.0
1.7
1.5
1.2
1.0
1.0
0.7
0.7
0.5
0.36
0.25
TRM1
TRM6
HSP-1
HSP-2
ACCESORIES
Rev. 031516
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
Disconnect all
power before
installing or
working with
this equipment.
Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
存在电击、
爆炸或电弧
闪烁危险
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
The product's side panels may be hot, allow
the product to cool before touching.
Follow proper mounting instructions including
torque values.
Do not allow liquids or foreign objects to enter
this product.
Failure to follow these instructions can result in
serious injury, or equipment damage.
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
Respecter les consignes de montage, et
notamment les couples de serrage.
Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
Le non-respect de cette directive peut entraîner,
des lésions corporelles graves ou des
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
Beachten Sie die Montageanweisungen,
Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
Respetar las instrucciones de montaje, y en
particular los pares de apretado.
No dejar que penetren líquidos o cuerpos
extraños en el producto.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
Seguire le istruzioni di montaggio corrette.
Non far entrare liquidi o oggetti estranei in questo
apparecchio.
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
材料损坏和高温外壳的危险性
产品的一侧面板可能很热,在其冷却前请
不要触碰。
遵照正确的安装说明,包括扭矩值。
请勿让液体及其他异物进入本产品。
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated
(Pb) (Hg) (Cd) Chromium
(Cr (VI))
biphenyls
(PBB)
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
有毒有害物质或元素
名称 六价铬 多溴联苯 多溴二苯醚
(Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE)
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Datasheet
Panel Mount
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Crydom:
CL240A05 CL240A05C CL240A05R CL240A05RC CL240A10 CL240A10C CL240A10R CL240A10RC
CL240D05 CL240D05C CL240D05R CL240D05RC CL240D10 CL240D10C CL240D10R CL240D10RC
CL240D10H CL240A05CH