http://www.tracopower.com Page 3 of 7
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Output Specifications
Output voltage adjustment range ± 10 %
Regulation – Input variation 0.1 % max. (0.2% max. for 5 VDC model)
– Load variation (0 – 100%) 0.4 % max. (0.8% max. for 5 VDC model)
Ripple and noise (20Mhz Bandwidth) 75 mV pk-pk max.
Output current limitation > 105 % Inom.
Overload protection mode ESP 18 – 150 Constant current
Over voltage protection (only output 1) 115 – 150 % Vout nom.
Capacitive load < 10’000 µF
General Specifications
Temperature ranges – Operating 0 °C…+60 °C
– Derating above 50°C all models 2.0% /K
– Storage (non operating) – 20 °C…+85 °C
Temperature coefficient 0.02 % /K
Efficiency 73 – 87 % (depending on model)
Humidity (non condensing) 85 % rel max.
Switching frequency Vin = 115 VAC Vin = 230 VAC
ESP 18 (FM modulation) ~100 kHz ~150 kHz
ESP 36 (FM modulation) ~ 80 kHz ~130 kHz
ESP 60 (FM modulation) ~ 50 kHz ~100 kHz
ESP 75 (PWM modulation) ~120 kHz ~120 kHz
ESP 100 (PWM modulation) ~140 kHz ~140 kHz
ESP 150 (PWM modulation) ~135 kHz ~135 kHz
Hold-up time Vin = 115 VAC Vin = 230 VAC
ESP 18 20 ms typ. 120 ms typ.
ESP 36 20 ms typ. 120 ms typ.
ESP 60 20 ms typ. 120 ms typ.
ESP 75 50 ms typ. 40 ms typ.
ESP 100 50 ms typ. 50 ms typ.
ESP 150 50 ms typ. 40 ms typ.
Switching Power Supplies
ESP Series 18-150 Watt