PWS
-1K41F-
1R
1400W 1U Redundant AC
-DC Power Supply
Specification
INPUT CHARACTERISTICS
RATED VOLTAGE /
CURRENT
100
-140Vac/180-240Vac
14.7
-10.5A (1200W)
9.5
-7.2A (1400W)
RATED FREQUENCY
50
-60Hz
INRUSH
CURRENT
Less
than 35Apk
POWER FACTOR
> 95%
at max load
DC OUTPUT CHARACTERISTICS
MAXIMUM
POWER
1200W @
100 to 140Vac &
1400W @
180 to 240Vac
EFFICIENCY
80Plus
Gold
Typical 92%+ @ 230Vac 50% load
VOLTAGE
+12V
+5Vsb
MAXIMUM
CURRENT
100
A@ 100Vav-
140Vac
117
A@ 180Vac-
240Vac
6.0
A
REGULATION
+/
-5%
+/
-5%
RIPPLE & NOISE
120 mV
50
mV
OUTPUT CONNECTOR
FCI P/N 51720
-0601603AB
HOLD UP TIME
Main 12V output 20mS measuring
at 75% of max load
GENERAL SPECIFICATIONS
REMOTE MANAGEMENT
PMBus
1.1 Compatible
FRU Data
MTBF
>250,000 hours at 25
°C
REDUNDANCY
Hot swappable, N+1
LEAKAGE CURRENT
3.5
mA Max
PROTECTION
Output Over Current/Voltage, Short
Circuit, Under Voltage, Over
Temperature
Dimension (W x L x H): 298*104.5*40.4mm
Maximum Output Power: 1200/1400W
REGULATORY
SAFETY COMPLIANCE
UL60950
-1/CSE 60950-1
EN60950
-1
IEC60950
-1
CB Report
CE
BSMI
CQC
EMC
EMI Class A
ENVIRONMENTAL SPECIFICATIONS
AMBIENT
TEMPERATURE
Operating: 0 to 50
°C
Non
-Operating: -40 to 70 °C
OPERATING
ALTITUDE
Operating: up to
2,000m
Non
-Operating: to 5,000m
RELATIVE
HUMIDITY
Operating: 20% to 95% RH,
(non
-condensing)
Non
-Operating: 5% to 95% RH
(non
-condensing)
Features and Benefits:
Gold 92%+ Efficiency
PMBus and FRU Function Support
Front loading
Disclaimer: Specification is subject to change without prior notice